首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In the framework of new European directives in the field of ambient air quality assessment specific requirements for measurement methods for benzene will be defined and have to be met in the future. In a residential area in the vicinity of a cokery a comprehensive monitoring programme for BTX compounds (benzene, toluene, xylenes) was carried out with diffusive samplers. Measurement results from 20 sites show a distinct spatial distribution of benzene concentrations which is caused by the emissions of the plant. Comparisons with two pumped measurement methods reveal excellent agreement in the case of benzene. An assessment of measurement uncertainty for the diffusive method is presented in terms of standard deviations from parallel measurements (precision) and by comparison with a reference method according to national and international standards. Data quality objectives required by an upcoming European directive for benzene can be met by diffusive sampling.  相似文献   

2.
宁波市环境空气中VOCs污染状况及变化趋势分析   总被引:7,自引:4,他引:3  
基于近7年来的连续监测数据,对宁波市环境空气中挥发性有机物(VOCs)的污染状况及变化趋势进行了初步分析。研究表明:在宁波市环境空气中检测出94种VOCs,其主要成分是饱和烷烃、芳烃、烯烃、卤代烃、卤代芳烃、含氧有机物等,有37种属有毒有害物质,其中苯系物含量最高;宁波市环境空气中苯系物的污染程度与国内外城市基本处于同一水平,近年来的污染状况变化不大,没有明显恶化;空间分布特征显示一类保护区VOCs的排放以天然源为主,二类各功能区VOCs的排放由天然源和局部人为污染源共同形成,三类区以工业污染源排放为主;时间变化趋势显示VOCs在冬季和春季的平均浓度比其他季节高,VOCs的日变化基本呈现2个主浓度峰值特征,跟城市交通流量变化具有很好相关性。  相似文献   

3.
扬州地区酸雨现状及成因分析   总被引:4,自引:0,他引:4  
根据2006年1月—2010年12月的酸雨监测数据,对扬州地区酸雨的变化规律和趋势进行了统计分析。结果表明:扬州地区酸雨主要集中在扬州市区与仪征城区,"十一五"期间,扬州市区酸雨呈逐年减少趋势,仪征城区大气污染严重,降水pH年均值均小于5.6,经评价扬州市区属于非酸雨区-较重酸雨区,仪征城区属于轻酸雨区-重酸雨区。高邮、江都、宝应城区从2007年起无酸雨出现。仪征城区酸雨主要是由燃煤型和燃油型混合空气污染造成的,近年来随着机动车拥有量的迅速增加,各种机动车排放的尾气已成为形成酸雨的重要原因,应引起重视。  相似文献   

4.
The main objective of the present investigation is to study the temporal and spatial variations of the quality of ambient air in the Kingdom of Bahrain. The non-parametric Kruskal-Wallis (KW) test showed significant spatial variations and interactions of spatial-temporal among five mobile monitoring stations for 11 air pollutants. The Mann Whitney (MW) test demonstrated the seasonality of spring over winter for the PM(10), PM(2.5), NO(2), CO and p-xylene, the seasonality of winter over spring for O(3), and no significant seasonal variation for NH(3), benzene, SO(2), toluene and H(2)S. It is concluded that emissions from automobile exhaust, industrial and developmental projects are responsible for the spatial air pollution, and that air temperature is the controlling factor for the seasonal variations.  相似文献   

5.
Results from a five month monitoring campaign of BTX (benzene, toluene and the sum of ethyl benzene, o-xylene, m-xylene and p-xylene), performed at Monterotondo, a little town 23 km NE of Rome, and correlation of the measured concentrations with meteorological and natural radioactivity data are presented and discussed. This campaign allowed us to extrapolate a pattern of the annual distribution of benzene in the town. A map, showing the average distribution of pollutants, is presented, as a useful tool to manage an appropriate policy of air pollution. A contemporary indoor-outdoor investigation has been performed at five homes and two classrooms of Monterotondo and at thirteen homes and thirteen classrooms in the outskirts of Rome. Non-smoking people and low polluted sites were chosen for this campaign, in order to highlight if commonly used domestic materials could act as internal sources. Data, obtained by employing long-term diffusive samplers, are compared with a parallel experiment showing the day-night indoor-outdoor trend. The obtained results, confirmed through statistical analysis of data, let us conclude that there is evidence of internal sources at homes whilst, in the schools, depletion phenomena prevail, probably due to the walls adsorption.  相似文献   

6.
Diffusive sampling of Volatile Organic Compounds (VOCs) onto thermal desorption tubes, followed by gas chromatography, is an established technique for area or personal monitoring of typical workplace concentrations and there has been increasing interest in extending the application to environmental levels, particularly for benzene, toluene and xylene (BTX). Diffusive sampling rates for BTX on Chromosorb 106 and Carbograph-1 (a graphitised carbon) were measured over periods of 1-4 weeks in field validation experiments using ambient air and parallel pumped sampling (the reference method) at the HSL site in central Sheffield. The reference method was also used to investigate the possible bias of an open-path spectrophotometer (OPSIS) used by Sheffield City Council. A bias for BTX was suspected from results of a two-week initial exercise in which several diffusive samplers were placed close to the light path. In the full field validation of the diffusive samplers carried out subsequently, the significant bias of BTX concentrations reported by OPSIS were confirmed when compared with concurrent results from the reference method. OPSIS gave benzene and toluene values up to eight times higher than expected from the GC measurements. Xylene discrepancies were smaller, but in one 3-day peak episode, OPSIS demonstrated a negative correlation with GC.  相似文献   

7.
基于3S技术的桂林市南溪河污染现状调查   总被引:1,自引:1,他引:0  
城区小流域常是水污染较重的区域,又是污染源密集的地方,其非点源污染的监测与评估,需要实用方法。本调查基于3S技术,开展流域的监测与评价,包括空间定位的精度控制、非点源的遥感分类解译、采用排污系数对非点源污染评估、对污染源及污水管网做GIS空间分析。结合水质监测进行污径比和水环境容量的评价。重点讨论了城区人口解译方法和污染源评估方法,探讨典型城区非点源污染监测的思路。  相似文献   

8.
Passive air sampling for nitrogen dioxide (NO(2)) and select volatile organic compounds (VOCs) was conducted at 24 fire stations and a compliance monitoring site in Dallas, Texas, USA during summer 2006 and winter 2008. This ambient air monitoring network was established to assess intra-urban gradients of air pollutants to evaluate the impact of traffic and urban emissions on air quality. Ambient air monitoring and GIS data from spatially representative fire station sites were collected to assess spatial variability. Pairwise comparisons were conducted on the ambient data from the selected sites based on city section. These weeklong samples yielded NO(2) and benzene levels that were generally higher during the winter than the summer. With respect to the location within the city, the central section of Dallas was generally higher for NO(2) and benzene than north and south. Land use regression (LUR) results revealed spatial gradients in NO(2) and selected VOCs in the central and some northern areas. The process used to select spatially representative sites for air sampling and the results of analyses of coarse- and fine-scale spatial variability of air pollutants on a seasonal basis provide insights to guide future ambient air exposure studies in assessing intra-urban gradients and traffic impacts.  相似文献   

9.
The European legislation on ambient air quality introduces the concepts of spatial representativeness of a monitoring station and spatial extent of an exceedance zone. Spatial representativeness is an essential macro-scale siting criterion which should be evaluated before the setting-up and during the life of a monitoring point. As for the exceedance area, it has to be defined each time an environmental objective is exceeded in an assessment zone. No specific approach is prescribed to delimit such areas. A probabilistic methodology is presented, based on a preliminary kriging estimation of atmospheric concentrations at each point of the domain. It is applied to NO2 pollution on the urban scale. In the proposed approach, a point belongs to the area of representativeness of a station if its concentration differs from the station measurement by less than a given threshold. To take the estimation uncertainty into account, the standard deviation of the kriging error is used in a probabilistic framework. The choice of the criteria used to deal with overlapping areas is first tested on NO2 annual mean concentration maps of France, built by combining surface monitoring observations and outputs from the CHIMERE chemistry transport model. At the local scale, data from passive sampling surveys and high -resolution auxiliary variables are used to provide a more precise estimation of the background pollution in different French cities. The traffic-related pollution can also be accounted for in the map by additional predictors such as distance to the road, and traffic-related NOx emissions. Similarly, the proposed approach is implemented to identify the points, at a given statistical risk, where the NO2 concentration is above the annual limit value.  相似文献   

10.
以乌鲁木齐市2008-2012年7个空气自动监测点位小时浓度数据为基础数据,利用ArcGIS 技术,分析了其NO2年变化、月变化、日变化、空间分布等污染特征。结果表明,NO2年均值为0.065~0.068 mg/m3,基本保持稳定;NO2呈明显的季节变化,冬季污染较重,春节、秋季次之,夏季空气质量相对较好;NO2呈现“单峰型”的日变化特征,夜间NO2明显高于白天;不同季节 NO2的空间分布特征不同,与交通、供暖、人口密度、地理位置密切相关;NO2分布与风速相关关系明显,而与气温、湿度的关系为非线性。  相似文献   

11.
The need to collect data representative of overall urban pollution is all-important in order to monitor the population exposure. High spatial resolution monitoring using diffusive samplers allows studying of the urban pollutant distribution, thus enabling deeper investigation of their generation and diffusion mechanisms. Nevertheless, such a monitoring campaign has a certain cost. In this study we point out how to find the best compromise between the number of necessary measurements and the affordable costs for monitoring campaigns. We also describe an innovative method for the proper design of a fixed urban monitoring network by means of preliminary high spatial resolution campaigns using diffusive samplers. Four European capital cities (Dublin, Madrid, Paris and Rome) were monitored six times, each time for seven days. Benzene, toluene, ethylbenzene, xylenes (BTEX) and NO(2) concentrations were measured at 146 sites in Dublin, 293 in Madrid, 339 in Paris and 290 in Rome. Multiscale grids have been drawn which ranged in mesh size from 500 m to 2 km. The statistical processing of data produced a twofold result: the creation of isoconcentration maps with geostatistical procedures, and an algorithm aimed at locating the minimum number of sampling sites where the fixed monitoring stations should be placed. Average urban levels estimated on the basis of these selected sites differ by less than 8% from those calculated on the whole populations of the sampled points. The aim of this work is to investigate how far the resolution of a monitoring campaign of urban pollution by diffusive sampling can be reduced, thus making the monitoring less expensive in terms of human and financial resources, while preserving the same quality of the results that could be achieved with a higher resolution. We found that there is no significant loss of information when the resolution of the monitoring grid for BTEX is lowered to a mesh size of 1.85 km, that is a sampling site each 3.4 km(2), and that the minimum number of sampling sites to be used is N = 0.29 A, where A is the urban surface to be monitored (in km(2)). As the spatial distribution of NO(2) is less sensitive to the distance from the emission source than that of BTEX, this relationship could be retained as a valid lower limit for the mesh grid size also for NO(2) monitoring.  相似文献   

12.
PM(2.5) and VOCs (benzene, toluene, m-p-o-xylenes) concentrations were measured in an urban and a suburban site in Athens, Greece, during the period between April and November 2004. This period, which is considered to be the warmer period in Greece, is characterized by the development of sea-breeze over the Attica Basin. Additionally strong Northern, North-eastern winds called "The Etesians", predominate during the summer months (July-August), acting positively to the dispersion of pollutants. In this campaign, 24 days with sea-breeze development were observed, 15 days with northern winds, 6 days with southern winds while the rest of the days presented no specific wind profile. Maximum concentrations of PM(2.5), VOCs and nitrogen oxides, were detected during the days with sea-breeze, while minimum concentrations during the days with northern winds. Ozone was the only pollutant that appeared to have higher concentrations in the background site and not in the city centre, where benzene presented strong negative correlation with ozone, indicating the photochemical reaction of hydrocarbons that lead to the ozone formation. The BTX ratios were similar for both sites and wind profiles, indicating common sources for those pollutants. T/B ratio ranged in low levels, between 3-5 for site A and 2-5 for site B, suggesting vehicles emissions as the main sources of volatile compounds. Finally, the strong correlations of PM(2.5) and benzene concentrations, between the two sampling sites, indicate that both the city centre and the background site, are affected by the same sources, under common meteorological conditions (sea-breeze, northern winds).  相似文献   

13.
利用VOCs在线监测技术,对2010年宁波市北仑区空气内的VOCs的浓度、组成、变化规律及来源进行分析研究。结果表明,在北仑区域内的16种VOCs中,苯、甲苯、二甲苯、乙苯和己烷的比例占到了总数的82.9%,且该5种有机物浓度存在较为典型的季节性变化规律和日变化规律;采用CMD模型法对VOCs的来源进行解析后发现,北仑区域内的VOCs主要来源于汽车尾气、汽油蒸气和石油液化气,而且汽车尾气的贡献值要比一些大城市低得多,且夏季和冬季的成分源贡献率存在明显差异。  相似文献   

14.
This study investigated the biomarker responses of the earthworm, Eudrilus eugeniae, exposed to sublethal concentrations of benzene, toluene and xylene (BTX) for a time span of 28 days. Lipid peroxidation (LPO) and histopathological alterations were examined. Toxicological evaluations of BTX were carried out against E. eugeniae. On the basis of the 96-h LC50 value, xylene (1.212 mg/kg) was found to be the most toxic followed by toluene (1.335 mg/kg) and benzene (1.896 mg/kg) was the least toxic. The exposure of earthworms to sublethal concentrations (1/10th and 1/100th of 96 h LC50) of BTX premixed with the substrate (loamy and humus soil) induced pathological changes in the clitella such as severe lesion, necrosis and dark brown pigments. The result of the lipid peroxidation assay showed a significant increase in oxidative damage with LPO values ranging from 2.58–7.8 nM/g in exposed animals when compared to 0.07 nM/g in the control group. The findings from this study suggest the use of LPO and histopathology as useful biomarkers of exposure for early detection of petroleum related stress in terrestrial ecosystems  相似文献   

15.
The Helsinki Metropolitan Area Council (YTV) is responsible for air quality monitoring in the Helsinki area. Air quality has been monitored periodically since the late 1950s. An automatic SO2 monitoring network was constructed in 1975 and TSP measurements were added in 1978. Since then the network has been expanded and currently five automatic multicomponent stations form the basis of the network monitoring SO2, NO, NO2, CO, PM10 and O3 concentrations. Manual TSP and PM10 measurements are also conducted. Mobile monitoring units are also being used as well as special measurement campaigns. The effects of air pollution on nature are studied in bioindicator monitoring. An air quality index is used in order to inform the public of the current air quality situation. Changes in air quality are reflected in monitoring strategy. SO2 concentrations have decreased in the past two decades. Annual averages in 1995 were at or below 5 µg/m3. Traffic is the major source for pollutants even though catalytic converters have lowered traffic emissions somewhat. The highest annual average NO2 concentration at an urban site was 49 µg/m3 in 1995, and there has been no clear change in NO2 levels. There has been a decreasing trend in CO concentrations. Maximum annual TSP and PM10 averages in 1995 were 92 and 32 µg/m3, respectively. The highest average lead concentration was 0.01 µg/m3. Elevated concentrations are experienced from time to time. During the spring daily TSP and PM10 concentrations can go up to around 300 and 150 µg/m3, respectively. This is caused by resuspension mainly due to street sanding. Also a major winter NO2 episode occurred in December 1995. The highest hourly NO2 concentrations reached 400 µg/m3.  相似文献   

16.
Measurements of fortnightly average concentrations of NO, NO2, SO2, H2S, NH3, and volatile organic compounds (VOCs) (aromatics = benzene, toluene, o-xylene, m + p-xylene, ethyl benzene; non-aromatics = nonane and octane) were carried out in the period from 26/10/05 to 24/11/05 at 20 points in the southern part of Kuwait as part of a baseline environmental impact assessment study requested by Kuwait National Petroleum Company. Two waves of triplicate diffusive passive samplers were used. A high volume air sampler was used to measure PM10 too. During the sampling period, the wind was observed to be mainly from the west and northwest with an average of 4.28 m/s. The consistency of the results allowed the production of spatial distribution maps of the pollutants measured and consequently the comparison between levels of air pollution at different locations. A comparison between the measured concentrations and the applicable air quality standards promulgated by Kuwait Environment Public Authority (KEPA) showed that those compounds had low concentrations compared to both industrial and residential KEPA standards. For other compounds which are not covered by KEPA standards, the results were compared with relevant limits of US Environment Protect Agency (USEPA) and US Department of Labor, Occupational Safety and Health Administration. The comparison showed that the measured compounds had low concentrations compared to the existing standards and, accordingly, no violation of air quality standards is reported.  相似文献   

17.
惠州市城区NO2污染水平的分析与模拟   总被引:1,自引:1,他引:1  
分析了2004年惠州市城区各监测站点的NO2数据,结果表明,NO2对城区空气质量影响不大。采用了城市空气质量管理软件模拟了NO2空间分布及日变化情况,且与实测值的比较分析表明,模拟结果在城区内有可比性。但地处城市边缘地带的污染模拟受光化学和区域性污染的影响,有待于进一步研究。所得结论可为惠州市城区优化布点的研究提供一定的参考。  相似文献   

18.
This article investigates the relationship of local air pollution pattern with urban land use and with urban thermal landscape using a GIS approach. Ambient air quality measurements for sulfur dioxide, nitrogen oxide, carbon monoxide, total suspended particles, and dust level were obtained for Guangzhou City in South China between 1981 and 2000. Landsat TM images and aerial photo derived maps were used to examine city's land use and land cover at different times and changes. Landsat thermal infrared data were employed to compute land surface temperatures and to assess urban thermal patterns. Relationships among the spatial patterns of air pollution, land use, and thermal landscape were sought through GIS and correlation analyses. Results show that the spatial patterns of air pollutants probed were positively correlated with urban built-up density, and with satellite derived land surface temperature values, particularly with measurements taken during the summer. It is suggested that further studies investigate the mechanisms of this linkage, and that remote sensing of air pollution delves into how the energy interacts with the atmosphere and the environment and how sensors see pollutants. Thermal infrared imagery could play a unique role in monitoring and modeling atmospheric pollution.  相似文献   

19.
各类无线技术的发展和应用导致公众曝露于环境中的电磁场辐射的程度越来越高,由此引发的对人体健康风险的担忧促使诸多国家和组织开展了相关研究,并制定了电磁环境控制限值,电磁环境的空间分布也成为至关重要的基础数据。于2019年10—12月对北京市中心3个典型商区的电磁环境进行了测试,测试频段为10 MHz~8 GHz,属于射频范围。通过空间插值方法对测试数据进行处理,从而得到测试区域的射频电磁环境空间分布地图。对测试数据的进一步分析表明,测试区域的射频电磁环境水平主要分布在0.5~2.5 V/m,随空间距离变化较为剧烈,总体上符合《电磁环境控制限值》(GB 8702—2014)的要求。建议在城市发展过程中,对射频电磁环境进行持续、精细的监测。  相似文献   

20.
Long-term phenol, cresols and BTEX monitoring in urban air   总被引:1,自引:0,他引:1  
This paper reports the results of a long-term monitoring of benzene, toluene, ethylbenzene, xylenes (BTEX), phenol and cresols in the air of Padua during a wide period of the year 2007 using two radial passive samplers (Radiello system) equipped with BTEX- and phenol-specific cartridges. Two sites were monitored, one in the industrial area and one close to the town centre. Relevant pollution episodes have been observed during both the winter and summer periods. Benzene, together with toluene, ethylbenzene and xylenes showed their maximum concentrations during the winter season, but the secondary pollutant phenol was higher than benzene for a large period of the year when the meteorological conditions blocked the pollutants in the lower layers of the atmosphere and solar radiation increased the benzene photo-oxidation process.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号