首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 171 毫秒
1.
利用LnfoWorks软件模拟了上海市污水治理二期工程的水力学特征。根据实际运行数据校正了阻力系数,并对模型进行了客观验证。结果表明,采用的水力模型可以很好地体现上海市污水治理二期工程污水输送系统的运行状况。采用自动水泵运行顺序可以获得比手动控制更稳定的水位。非满流存在于M2泵站前的某些管段中,为了提高大流量下整个系统的输送能力,SA和M2泵站之间的管线调储能力可充分利用。  相似文献   

2.
污水处理厂除臭工艺选择及工程设计   总被引:2,自引:0,他引:2  
随着无锡市城北污水处理厂二期工程的扩建,污水处理厂除臭问题日益突出.针对目前常用的化学、活性炭吸附、氧离子基团、燃烧、纯天然植物提取液喷洒和生物等6种除臭方法,重点说明了除臭工艺的选择及除臭系统的工程设计,最后结合运行情况总结了除臭系统的设计特点.  相似文献   

3.
以模拟城市污水为处理对象,采用循环式活性污泥法(CAST)反应器,对3种运行模式(M1:常规模式,M2:缺氧好氧模式、M3:缺氧好氧交替模式)下系统的脱氮性能进行了研究,比较了各模式下CAST反应器的氨氮和总氮的去除效率,并对各模式下典型周期内氮基质浓度变化进行了考察,以确定系统的脱氮模式。结果表明,在氨氮去除不成为限制条件(去除率90%)的条件下,3种运行模式下系统总氮的平均去除率分别为67.3%、70.6%和82.4%,以缺氧好氧交替模式下的最高;M1、M2和M3均可实现亚硝酸型硝化,但随着温度的升高,亚硝酸型硝化逐渐消失。静态实验分析表明,3种模式下系统的氨氧化速率大小次序为:vN:M1vN:M2vN:M3,反硝化速率大小次序为:vDN,M2vDN,M3vDN,M1。  相似文献   

4.
以模拟城市污水为处理对象,采用循环式活性污泥法(CAST)反应器,对3种运行模式(M1:常规模式,M2:缺氧好氧模式、M3:缺氧好氧交替模式)下系统的脱氮性能进行了研究,比较了各模式下CAST反应器的氨氮和总氮的去除效率,并对各模式下典型周期内氮基质浓度变化进行了考察,以确定系统的脱氮模式。结果表明,在氨氮去除不成为限制条件(去除率〉90%)的条件下,3种运行模式下系统总氮的平均去除率分别为67.3%、70.6%和82.4%,以缺氧好氧交替模式下的最高;M1、M2和M3均可实现亚硝酸型硝化,但随着温度的升高,亚硝酸型硝化逐渐消失。静态实验分析表明,3种模式下系统的氨氧化速率大小次序为:vN:M1〉vN:M2〉vN:M3,反硝化速率大小次序为:vDN,M2〉vDN,M3〉vDN,M1。  相似文献   

5.
农村污水管道系统是农村污水收集处理设施的重要组成部分,在采用纳入城镇污水管网处理和村落集中处理模式的农村地区发挥了重要作用。由于农村污水管道在设计、建设、运行、维护等环节存在一些问题,农村污水管道堵塞的现象时有发生。为有效降低农村污水管道堵塞发生率,保证农村污水收集系统的稳定运行,分析了农村污水管道堵塞的成因,提出了农村污水管道防堵和长效运行的建议和对策,包括优化农村污水管道管径设计、补齐管道系统配套设施、提升施工质量、强化正确的排水习惯宣传、加强科学维护管理工作和采用"三位一体"的县域统筹模式等。这些建议和对策可以有效降低农村污水管道堵塞的发生率,为提升农村卫生水平和生态环境质量提供参考。  相似文献   

6.
采用连锁控制的A2/O-MBR工艺处理石化社区低浓度的生活污水并回用,处理规模520 m3/h。工程运行监测结果表明,该工艺对低浓度生活污水处理效果良好,出水水质达到了《城镇污水处理厂污染物排放标准》(GB18918-2002)的一级B标准和《污水再生利用工程设计规范》(GB50335-2002)标准要求。通过连锁控制,系统运行稳定,具有较强的耐冲击负荷能力,实现了污水处理厂正常运行。  相似文献   

7.
根据上海市水环境污染物排放的现状及有关统计数据,采用Sigmoid模型,对未来的变化趋势进行了预测。并通过上海市污水治理设施状况及其水环境质量状况的调查数据,研究了水环境质量与社会经济发展的关系,进一步分析了水环境质量对上海中长期发展的制约。在此基础上,对改善水环境质量以减少对未来发展的制约,提出了相应的对策与建议。  相似文献   

8.
实际污水与模拟污水活性污泥系统的特性差异   总被引:2,自引:0,他引:2  
实验中经常采用人工配置的模拟生活污水,为了研究其与实际生活污水活性污泥系统的特性差异,采用2个序批式间歇反应器(SBR)进行平行实验(厌氧、好氧方式运行),系统地考察了在进水主要组分和运行参数相同的情况下,不同原水对活性污泥系统脱氮、除磷、比好氧速率、污泥絮体形态和出水水质等方面的影响。结果表明,模拟污水系统的硝化活性强于实际污水系统,两者的平均硝化速率分别为7.43 mg NH4+-N/(L.h)和5.55 mg NH4+-N/(L.h)。在前置厌氧段,模拟污水系统的释磷量比实际污水系统高出36.45%。两者在后续好氧阶段都能够充分吸磷。模拟污水系统的平均比好氧速率(SOUR)高达64.54 mg O2/(g MLSS.h),而实际污水系统的则只有32.81 mg O2/(g MLSS.h)。模拟污水系统的污泥絮体疏松,粒径小,形状不规则,沉降性差,沉后出水平均悬浮物浓度(SS)为20 mg/L;而实际污水系统的污泥絮体则密实、粒径大,沉降性好,沉后水十分清澈,SS几乎检测不出。  相似文献   

9.
污水处理的高能耗和新能源利用已引起人们的关注,本文根据太阳光照强度的周期变化和农村污水昼夜排放量悬殊的特征,提出了一种新型的利用无蓄电池太阳能光伏系统驱动的污水生物处理系统,可有效降低太阳能光伏系统的成本。生物反应器是一个双沟式一体化氧化沟。按照启动的用电设备的数量,一体化氧化沟具有5种运行方式。在不同的运行方式下,一体化氧化沟的内沟和外沟具有不同的功能,其中运行方式3到运行方式5对污染物去除效率最高。采用阶梯型电量输出模式,可以充分利用太阳能,并保障一体化氧化沟的高效运行时间。在160 d的连续运行实验中,COD、氨氮、总氮和总磷的平均去除率分别为87.8%、98.4%、68.7%和80.3%。证明无蓄电池太阳能光伏系统驱动污水生物反应器处理农村分散污水是可行的。  相似文献   

10.
基于西安市污水处理厂出水一级A达标排放的要求,对西安市某污水处理厂A2/O工艺运行效果进行监测分析,结果表明,该污水处理厂出水总磷一级A达标率仅为31.61%,出水总磷浓度偏高成为该污水处理厂一级A达标的限制因素。通过对污水处理厂现场调研与水质沿程监测分析发现,该污水处理厂污泥水中含有大量SS和TP,此部分污泥水回流至系统前端导致生物池进水总磷浓度急剧升高,生物池超负荷运行导致出水总磷偏高。同时由于生物池碳源不足,厌氧池释磷作用微弱,影响了系统的除磷效果。针对以上问题,进行了初沉池运行方式调整、强化污泥处理、出水增设滤池等一系列改造措施。改造后系统除磷效果明显提高,出水TP降低至(0.39±0.08)mg·L~(-1),基本可以达到一级A排放标准。  相似文献   

11.
Polychlorinated biphenyls (PCBs) were determined in a aquatic community from Los Padres Lake, Argentina. Twenty four PCB congeners from tri- to octa-chlorinated isomers were detected and quantified using conventional gas chromatography with electron capture detector (GC-ECD). The aim of this study was to investigate the concentrations of PCBs in freshwater organisms from a shallow lake of Argentina. Stems of bulrush (Schoenoplectus californicus), whole tissues of false loosestrife (Ludwigia sp.) and grass shrimp (Palaemonetes argentinus), and liver, gonads, muscle and mesenteric fat (if present) of fish species (Rhamdia sapo) and (Oligosarcus jenynsi) were analyzed. Two areas were selected to macrophytes sampling: the input area, main PCB source of the lake (Station 1), and the output area, a potential anoxic zone (Station 2). Macrophytes from Station 1 bioconcentrated higher total PCB levels than Station 2, showing that the former have received PCBs washed down from upstream areas. Penta- and hexa-congeners were enriched relative to other congeners in animal biota and macrophytes from Station 1, consistent with commercial mixture of Aroclor 1254 used in this region. In bulrush from Station 2 a predominance of tri- and tetra-chlorinated congeners was observed. Grass shrimp showed the lowest PCB values among animal biota. PCB concentrations in fish tissues varied with the species and the gonadal development. Mesenteric fat, only present in post-spawning organisms of R. sapo, had the highest values of PCBs relative to other tissues. A clearance of total PCBs in ovaries of post-spawning females of R. sapo was observed, but not in testes. O. jenynsi/P. argentinus biomagnification factor (BMF) had a mean value of 18.7. Congeners 44, 52 and 151, showed the highest BMF values, being 64, 66 and 62, respectively. These values would be a consequence of the low depuration rate of 44 and 52 congeners with orthochlorine substitution conducted by O. jenynsi and the high depuration rate of congener 151, which lacks 4 4- chlorine substitution, carried out by grass shrimp. Although the most of congeners have been biomagnified, they did not clearly displayed a concomitantly increasing with log Kow.  相似文献   

12.
为了研究输煤皮带转载点密闭罩内流场对吸尘效果的影响,采用Fluent软件对某转载点密闭罩内气固两相流动情况进行了数值模拟。通过气流分布和煤尘浓度分布的分析,发现溜槽转折处较大的气流偏转会增加煤尘起尘量和导致局部煤尘积聚,吸尘罩的开口角度对吸尘效果也有较大影响。为了疏导气流并加强吸尘效果,提出了溜槽转折处和吸尘罩的结构优化设计方案。研究表明,改进后气流分布更加均匀,吸尘效果有所提高,从而为转载点密闭罩的优化设计提供了参考。  相似文献   

13.
Electrochemical oxidation of benzene on boron-doped diamond electrodes   总被引:1,自引:0,他引:1  
This work presents an electrochemical investigation of the benzene oxidation process in aqueous solution on boron-doped diamond (BDD) electrodes. Additionally, in order to determine the main products generated during the oxidation process, electrolysis and high performance liquid chromatography experiments were carried out. The complete degradation of this compound was performed aiming to a further application in waste water treatment. The cyclic voltammetry studies indicate that benzene is irreversibly oxidized in acid medium (H2SO4 0.5 M) on the BDD electrode surface at 2.0 V versus Ag/AgCl in a diffusion controlled process. During the cycling, other products are generated, and a pair of peaks was observed that can be associated with the oxi-reduction of anyone of the following species: hydroquinone, benzoquinone, resorcinol or catechol. The electrolysis experiments were carried out at 2.4 and 2.5 V on the BDD electrode surface in a solution containing 1 × 10−2 M of benzene (below the saturation concentration in aqueous solution), for 3 and 5 h, respectively. The main products measured were: hydroquinone, resorcinol, p-benzoquinone, catechol and phenol. The complete electrochemical benzene degradation was performed in the electrolysis experiments using a rotating BDD disc electrode (2.5 V for 5 h) and the main products detected were all measured at concentrations lower than 10−5 M in this condition. The boron-doped diamond electrode had proved to be a valuable tool for the electrochemical degradation of the benzene, a very stable chemical compound.  相似文献   

14.
Bayer-Raich M  Jarsjö J  Teutsch G 《Journal of contaminant hydrology》2007,90(3-4):240-51; discussion 252-7
We consider the results of a recent paper in this journal [Zeru, A. and Sch?fer, G., 2005. Analysis of groundwater contamination using concentration-time series recorded during an integral pumping test: Bias introduced by strong concentration gradients within the plume. Journal of Contaminant Hydrology 81 (2005) 106-124], which addresses the field-scale characterisation of contaminant plumes in groundwater. There, it is concluded that contaminant concentration gradients can bias Integral Pumping Test (IPT) interpretations considerably, in particular if IPTs are conducted in advective fronts of contaminant plumes. We discuss implications of this setting and also argue that the longitudinal and transverse dispersivities used in the examples of Zeru and Sch?fer (2005) of up to 30 m and 3 m, respectively, are generally very high for the here relevant capture zone scale (<20 m). However, regardless of both longitudinal and transverse concentration gradients, we further show through a counter-example that IPT results are unbiased as long as the concentration attenuation along the flow direction is linear over the capture zone extent.  相似文献   

15.
Verification of forecasts of COH levels at the Downtown Sampling Station using our objective forecast method developed in conjunction with the Allegheny County Bureau of Air Pollution Control gave excellent results. The next step was to expand the area of forecast coverage.

COH data taken from July 1968 through June 1969 from six sampling stations located roughly in a large concentric arc around the Downtown Station were studied. Three of the stations are located in river valleys near large industrial plants and the other three are located on higher terrain in suburban areas.

COH levels of Low, Moderate, High, and Very High (where Low = 0–0.9, Moderate = 1.0–1.9, High = 2.0–3.0, and Very High = >3.0) were used.

The total number of occurrences of High and Very High COHS at the Downtown Station was 10.7% of the total data sample. This was more than twice the frequency of any of the outlying stations.

An evaluation of the statistical frequencies indicate the Downtown Station can safely be used as a “control station” in forecasting Low or Moderate COH levels for the six surrounding stations. However, the occurrence of High or Very High COH levels at the six outlying stations do not occur with a high enough statistical consistency to be predicted by using the forecast value of the Downtown Station.

The valley stations exhibit the characteristics of separate sub air basins particularly during a period in which morning inversions occur for two or more consecutive days and the average daily wind speed does not exceed 4 m/sec.

The results show it is possible to forecast only Low or Moderate COH levels for each of the six outlying stations by using statistical correlations derived from the Downtown Station. Separate objective forecasts which relate the pollution buildup in each valley sub air basin must be used when High or Very High COHS are forecast at the Downtown Station.  相似文献   

16.
Global climate change may have large impacts on water supplies, drought or flood frequencies and magnitudes in local and regional hydrologic systems. Water authorities therefore rely on computer models for quantitative impact prediction. In this study we present kernel-based learning machine river flow models for the Upper Gallego catchment of the Ebro basin. Different learning machines were calibrated using daily gauge data. The models posed two major challenges: (1) estimation of the rainfall-runoff transfer function from the available time series is complicated by anthropogenic regulation and mountainous terrain and (2) the river flow model is weak when only climate data are used, but additional antecedent flow data seemed to lead to delayed peak flow estimation. These types of models, together with the presented downscaled climate scenarios, can be used for climate change impact assessment in the Gallego, which is important for the future management of the system.  相似文献   

17.
We consider the results of a recent paper in this journal [Zeru, A. and Schäfer, G., 2005. Analysis of groundwater contamination using concentration–time series recorded during an integral pumping test: Bias introduced by strong concentration gradients within the plume. Journal of Contaminant Hydrology 81 (2005) 106–124], which addresses the field-scale characterisation of contaminant plumes in groundwater. There, it is concluded that contaminant concentration gradients can bias Integral Pumping Test (IPT) interpretations considerably, in particular if IPTs are conducted in advective fronts of contaminant plumes. We discuss implications of this setting and also argue that the longitudinal and transverse dispersivities used in the examples of Zeru and Schäfer (2005) of up to 30 m and 3 m, respectively, are generally very high for the here relevant capture zone scale (< 20 m). However, regardless of both longitudinal and transverse concentration gradients, we further show through a counter-example that IPT results are unbiased as long as the concentration attenuation along the flow direction is linear over the capture zone extent.  相似文献   

18.
流速和水深是影响浅水型海湾扩散器初始稀释能力的主要环境因素,其长时间序列的实测资料在现实中通常很难得到,而平面二维水动力模型的引入可为初始稀释度的计算提供必要和准确的水动力要素。通过建立二维水动力模型模拟受纳海域的流场,利用实测水文资料进行模型的率定和验证,模拟设计水文条件下附近水域的流场,然后提取排污口处的水深、流速和流向的时间序列,再利用近区模型计算任一时刻的初始稀释度,最后进行累积频率分析得到设计保证率下的初始稀释度。将该方法应用于杭州湾某排污扩散器初始稀释能力的评估,研究表明,利用远区模型为扩散器近区模拟提供环境水文要素,弥补了实际工程计算中缺乏实测水文资料的不足,并大大提高了近区模拟的计算精度。  相似文献   

19.
Changes in contaminant fluxes resulting from aggressive remediation of dense nonaqueous phase liquid (DNAPL) source zone were investigated at two sites, one at Hill Air Force Base (AFB), Utah, and the other at Ft. Lewis Military Reservation, Washington. Passive Flux Meters (PFM) and a variation of the Integral Pumping Test (IPT) were used to measure fluxes in ten wells installed along a transect down-gradient of the trichloroethylene (TCE) source zone, and perpendicular to the mean groundwater flow direction. At both sites, groundwater and contaminant fluxes were measured before and after the source-zone treatment. The measured contaminant fluxes (J; ML(-2)T(-1)) were integrated across the well transect to estimate contaminant mass discharge (M(D); MT(-1)) from the source zone. Estimated M(D) before source treatment, based on both PFM and IPT methods, were approximately 76 g/day for TCE at the Hill AFB site; and approximately 640 g/day for TCE, and approximately 206 g/day for cis-dichloroethylene (DCE) at the Ft. Lewis site. TCE flux measurements made 1 year after source treatment at the Hill AFB site decreased to approximately 5 g/day. On the other hand, increased fluxes of DCE, a degradation byproduct of TCE, in tests subsequent to remediation at the Hill AFB site suggest enhanced microbial degradation after surfactant flooding. At the Ft. Lewis site, TCE mass discharge rates subsequent to remediation decreased to approximately 3 g/day for TCE and approximately 3 g/day for DCE approximately 1.8 years after remediation. At both field sites, PFM and IPT approaches provided comparable results for contaminant mass discharge rates, and show significant reductions (>90%) in TCE mass discharge as a result of DNAPL mass depletion from the source zone.  相似文献   

20.
Most soils contain preferential flow paths that can impact on solute mobility. Solutes can move rapidly down the preferential flow paths with high pore-water velocities, but can be held in the less permeable region of the soil matrix with low pore-water velocities, thereby reducing the efficiency of leaching. In this study, we conducted leaching experiments with interruption of the flow and drainage of the main flow paths to assess the efficiency of this type of leaching. We compared our experimental results to a simple analytical model, which predicts the influence of the variations in concentration gradients within a single spherical aggregate (SSA) surrounded by preferential flow paths on leaching. We used large (length: 300 mm, diameter: 216 mm) undisturbed field soil cores from two contrasting soil types. To carry out intermittent leaching experiments, the field soil cores were first saturated with tracer solution (CaBr2), and background solution (CaCl2) was applied to mimic a leaching event. The cores were then drained at 25- to 30-cm suction to empty the main flow paths to mimic a dry period during which solutes could redistribute within the undrained region. We also conducted continuous leaching experiments to assess the impact of the dry periods on the efficiency of leaching. The flow interruptions with drainage enhanced leaching by 10–20% for our soils, which was consistent with the model's prediction, given an optimised “equivalent aggregate radius” for each soil. This parameter quantifies the time scales that characterise diffusion within the undrained region of the soil, and allows us to calculate the duration of the leaching events and interruption periods that would lead to more efficient leaching. Application of these methodologies will aid development of strategies for improving management of chemicals in soils, needed in managing salts in soils, in improving fertiliser efficiency, and in reclaiming contaminated soils.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号