禽类屠宰加工废水处理技术   总被引:8,自引:0,他引:8  
介绍了厌氧水解酸化 循环活性污泥系统在禽类屠宰加工废水中的工程应用。结果表明 ,禽类加工废水在进水SS、CODCr、BOD5分别为 75 2mg/L、16 4 7mg/L、76 4mg/L的条件下 ,经该工艺处理后 ,外排废水的SS、CODCr、BOD5分别为 5 0mg/L、6 5mg/L、10 .1mg/L。该工艺具有占地面积小 ,处理效率好 ,运行费用低等特点 ,能广泛应用于禽类屠宰加工废水的处理。  相似文献   

2.
Batch respirometric tests have many advantages over the conventional biochemical oxygen demand (BOD) method for analysis of wastewaters, including the use of nondiluted samples, a more rapid exertion of oxygen demand, and reduced sample preparation time. The headspace biochemical oxygen demand (HBOD) test can be used to obtain oxygen demands in 2 or 3 days that can predict 5-day biochemical oxygen demand (BOD5) results. The main disadvantage of the HBOD and other respirometric tests has been the lack of a simple and direct method to measure oxygen concentrations in the gas phase. The recent commercial production of a new type of fiber optic oxygen probe, however, provides a method to eliminate this disadvantage. This fiber optic probe, referred to here as the HBOD probe, was tested to see if it could be used in HBOD tests. Gas-phase oxygen measurements made with the HBOD probe took only a few seconds and were not significantly different from those made using a gas chromatograph (t test: n = 15, R2 = 0.9995, p < 0.001). In field tests using the HBOD probe procedure, the probe greatly reduced sample analysis time compared with previous HBOD and BOD protocols and produced more precise results than the BOD test for wastewater samples from two treatment plants (University Area Joint Authority [UAJA] Wastewater Treatment Plant in University Park, Pennsylvania, and The Pennsylvania State University [PSU] Wastewater Treatment Plant in University Park). Headspace biochemical oxygen demand measurements on UAJA primary clarifier effluent were 59.9 +/- 2.4% after 2 days (HBOD2) and 73.0 +/- 3.1% after 3 days (HBOD) of BOD, values, indicating that BOD5 values could be predicted by multiplying HBOD2 values by 1.67 +/- 0.07 or HBOD3 by 1.37 +/- 0.06. Similarly, tests using PSU wastewater samples could be used to provide BOD5 estimates by multiplying the HBOD2 by 1.24 +/- 0.04 or by multiplying the HBOD3 by 0.97 +/- 0.03. These results indicate that the HBOD fiber optic probe can be used to obtain reliable oxygen demands in batch respirometric tests such as the HBOD test.  相似文献   

3.
The capacity to reach lower bounds for extraction of pollutants from wastewater by four floating aquatic macrophytes--water hyacinth (Eichhornia crassipes), water lettuce (Pistia stratiotes), salvinia (Salvinia rotundifolia), and water primroses (Ludvigia palustris)--is investigated. It is shown that the following lower bounds can be established for wastewater purification with water hyacinth: biochemical oxygen demand (BOD), 1.3 mg/L; chemical oxygen demand (COD), 11.3 mg/L; total suspended solids (TSS), 0.5 mg/L; turbidity, 0.7 NTU; ammonia, 0.2 mg/L; and phosphorus, 1.4 mg/L. Also, the following lower bounds can be established for wastewater purification with water lettuce: BOD, 1.8 mg/L; COD, 12.5 mg/L; TSS, 0.5 mg/L; turbidity, 0.9 NTU; ammonia, 0.2 mg/L; and phosphorus, 1.6 mg/L. These lower bounds were reached in 11- to 17-day experiments that were performed on diluted wastewater with reduced initial contents of the tested water quality indicators. As expected, water hyacinth exhibited the highest rates and levels of pollutant removal, thereby producing the best lower bounds of the water quality indicators. Given the initially low levels, BOD was further reduced by 86.3%, COD by 66.6%, ammonia by 97.8%, and phosphorus by 65.0% after 11 days of a batch experiment. The capacity of water plants to purify dilute wastewater streams opens new options for their application in the water treatment industry.  相似文献   

4.
The performance of an innovative membrane bioreactor (MBR) process using anoxic phosphorus uptake with nitrification and denitrification for the treatment of municipal wastewater with respect to operational performance and effluent quality is addressed in this paper. The system was operated at steady-state conditions with a synthetic acetate-based wastewater at a hydraulic retention time (HRT) of 12 hours and on degritted municipal wastewater at a total system HRT of 6 hours. The MBR system was able to achieve 99% biochemical oxygen demand (BOD), chemical oxygen demand (COD), and ammonia-nitrogen (NH4(+)-N); 98% total Kjeldahl nitrogen (TKN); and 97% phosphorus removal, producing effluent BOD, COD, NH4+-N, TKN, nitrate-nitrogen, nitrite-nitrogen, and phosphate-phosphorus of <3, 14, 0.2, 0.26, 5.8, 0.21, and <0.01 mg/L, respectively, at the 6-hour HRT. The comparison of the synthetic and municipal wastewater run is presented in this paper. Steady-state mass balance on municipal wastewater was performed to reveal some key features of the modified MBR system.  相似文献   

5.
The photo-Fenton reaction effect on the biodegradability improvement of 100 mg/L solution of 2,4-dichlorophenol (DCP) has been investigated. Biochemical oxygen demand (BOD) at 5 and 21 days, BODn/ chemical oxygen demand (COD) and BODn/total organic carbon (TOC) ratios, average oxidation state, and inhibition on activated sludge were monitored. For 50 mg/L hydrogen peroxide and 10 mg/L iron(II) initial concentrations and 40 minutes of reaction time in the photo-Fenton process, the biodegradability of the pretreated solution, measured as BOD5/COD ratio, was improved from 0 for the original DCP solution up to 0.18 (BOD21/COD = 0.24). At that point, all DCP was eliminated from the solution. To study the effect of the pretreatment step, the biological oxidation of pretreated solutions was tested in two semicontinuous stirred tank reactors, one operated with activated sludge and one with biomass acclimated to phenol. Results showed that more than 80% TOC removal could be obtained by codigestion of the pretreated solution with municipal wastewater. Total organic carbon removals of approximately 60% were also obtained when the sole carbon source for the aerobic reactors was the pretreated solution. The hydraulic retention times used in the bioreactors were of the same order of magnitude as those used at domestic wastewater treatment plants (i.e., between 12 and 24 hours). Kinetic studies based on pseudo-first-order kinetics have also been carried out. Constants were found to be in range 0.67 to 1.7 L x g total volatiles suspended solids(-1) x h(-1).  相似文献   

6.
A two-stage membrane bioreactor was used to treat dissolved-air-flotation pretreated, high-strength pet food wastewater characterized by oil and grease concentrations of 50 000 to 82 000 mg/L and total chemical oxygen demand (COD) and five-day biochemical oxygen demand (BOD5) concentrations of 100 000 and 80 000 mg/L, respectively, to meet stringent surface discharge criteria (i.e., BOD5, total suspended solids [TSS], and ammonium-nitrogen [NH4(+)-N] of < 10 mg/L at an overall hydraulic retention time of 6.3 days). Organic contaminants were removed primarily in the first stage, followed by almost complete removal of ammonia in the second stage. Despite a rise in poorly biodegradable COD in the second stage, overall removal of TSS, BOD5, COD, and ammonia was 100, 99.9, 95.2, and 99.7%, respectively, thus readily achieving the required criteria. Consistent nitrite accumulation over a period of more than 100 days, even at dissolved oxygen concentrations of more than 2.5 mg/L, was remarkable. A residual alkalinity requirement for nitrification was quantified. Membrane performance was extensively studied in this work.  相似文献   

7.
UASB-接触氧化-气浮处理柠檬酸废水   总被引:3,自引:0,他引:3  
介绍了UASB-接触氧化-气浮工艺处理柠檬酸废水的工程应用.工程运行表明,柠檬酸废水在进水SS、COD和BOD5分别为3427 mg/L、18 853 mg/L和11778 mg/L的条件下,经该工艺处理后,外排废水SS、COD和BOD5浓度分别为147.5 mg/L、223 mg/L和51.9 mg/L.该工艺具有占地面积小、工程投资和运行费用低及处理效果稳定等特点,能广泛应用于柠檬酸废水的处理.  相似文献   

8.
Food-service establishments that use on-site wastewater treatment systems are experiencing pretreatment system and/or drain field hydraulic and/or organic overloading. This study included characterization of four wastewater parameters (five-day biochemical oxygen demand [BOD5]; total suspended solids [TSS]; food, oil, and grease [FOG]; and flow) from 28 restaurants located in Texas during June, July, and August 2002. The field sampling methodology included taking a grab sample from each restaurant for 6 consecutive days at approximately the same time each day, followed by a 2-week break, and then sampling again for another 6 consecutive days, for a total of 12 samples per restaurant and 336 total observations. The analysis indicates higher organic (BOD5) and hydraulic values for restaurants than those typically found in the literature. The design values for this study for BOD5, TSS, FOG, and flow were 1523, 664, and 197 mg/L, and 96 L/day-seat respectively, which captured over 80% of the data collected.  相似文献   

9.

This work demonstrated a simple, low-cost, rapid, and effective biochemical oxygen demand (BOD) estimation system based on a packed-bed bioreactor that can be easily self-built on-site at a particular wastewater treatment plant for continuous monitoring of the influent and effluent. The use of natural microbial consortium that were collected from the target wastewater and immobilized on a cheap porous carrier simply by adhesion resulted in an acceptable accuracy of over 95%. The newly developed semi-continuous operating mode with peak-type signals was shown to be able to continuously estimate BOD at a high flow rate to overcome the flow dependence of the oxygen electrode, limit clogging issues, enhance the response time, and lower the limit of detection. The resulting packed-bed bioreactors could work continuously for 22 h with a coefficient of variance (CoV) of only 1.8% or for 13 h a day for several days with a maximum CoV of 1.4% and their response was observed to be stable over 80 consecutive measurements. They exhibited stable responses at a wide pH range of 6.5–8.5, which is also the recommended range for aerobic wastewater treatment, emphasizing the greater ease of use of natural microorganisms for BOD estimation.

  相似文献   

10.
对厌氧滤池反应器处理难降解印染废水进行中试研究。结果表明,厌氧滤池反应器水力停留时间(HRT)在8.1~14.6 h之间,进水COD浓度波动较大(500~1 000 mg/L)时,对COD平均去除率为20%。印染废水的BOD5/COD由0.23提高到0.35,废水可生化性明显改善。印染废水中硫酸根浓度略有下降,去除浓度为70 mg/L左右。厌氧滤池进出水颜色明显变化,由紫红色变为蓝黑色,紫外可见光谱分析表明废水中的有机物结构发生变化。  相似文献   

11.
矿化垃圾生物反应床处理畜禽废水的试验研究   总被引:2,自引:0,他引:2  
矿化垃圾具有较大的吸附比表面积 ,较强的阳离子交换容量 (6 7.9meq/ 10 0 g) ,无二次污染 ,是很好的污水处理生物介质。借助于矿化垃圾柱物理模型试验装置 ,在实验室进行了历时 6个月的矿化垃圾反应床处理畜禽污水试验。结果表明 ,系统出水有较大改善 ,出水溶解氧有较大提高 ,pH值呈中性。该处理系统对畜禽污水中色度、SS、CODCr、BOD5、NH3 N和总磷的平均去除率分别为 6 4.7%、5 4.2 9%、75 .33 %、88.71%、94.5 5 %和 99.83 % ;处理出水中CODCr、BOD5、NH4 N和总磷的平均浓度分别为 185 .6 1mg/L、14.94mg/L、2 6 .79mg/L和 0 .0 79mg/L ;总氮的平均去除率仅为 2 1.2 9%。反应器运行 6个月以来 ,运转良好 ,未发生阻塞现象  相似文献   

12.
Chen TY  Kao CM  Yeh TY  Chien HY  Chao AC 《Chemosphere》2006,64(3):497-502
The main objective of this study was to examine the efficacy and capacity of using constructed wetlands on industrial pollutant removal. Four parallel pilot-scale modified free water surface (FWS) constructed wetland systems [dimension for each system: 4-m (L)x1-m (W)x1-m (D)] were installed inside an industrial park for conducting the proposed treatability study. The averaged influent contains approximately 170 mg l(-1) chemical oxygen demand (COD), 80 mg l(-1) biochemical oxygen demand (BOD), 90 mg l(-1) suspend solid (SS), and 32 mg l(-1) NH(3)-N. In the plant-selection study, four different wetland plant species including floating plants [Pistia stratiotes L. (P. stratiotes) and Ipomoea aquatica (I. aquatica)] and emergent plants [Phragmites communis L. (P. communis) and Typha orientalis Presl. (T. orientalis)] were evaluated. Results show that only the emergent plant (P. communis) could survive and reproduce with a continuous feed of 0.4m(3)d(-1) of the raw wastewater. Thus, P. communis was used in the subsequent treatment study. Two different control parameters including hydraulic retention time (HRT) (3, 5, and 7d) and media [vesicles ceramic bioballs and small gravels, 1cm in diameter] were examined in the treatment study. Results indicate that the system with a 5-d HRT (feed rate of 0.4m(3)d(-1)) and vesicles ceramic bioballs as the media had the acceptable and optimal pollutant removal efficiency. If operated under conditions of the above parameters, the pilot-plant wetland system can achieve removal of 61% COD, 89% BOD, 81% SS, 35% TP, and 56% NH(3)-N. The treated wastewater meets the current industrial wastewater discharge standards in Taiwan.  相似文献   

13.
An upflow anaerobic sludge blanket (UASB)-anoxicaerobic system was used for treatment of tomato and bean processing wastewater. At various hydraulic retention times, ranging from 0.7 to 5 days, excellent removal of chemical oxygen demand (COD), biochemical oxygen demand (BOD), total suspended solids (TSS), ammonia-nitrogen (NH4-N), and total Kjeldahl nitrogen was achieved with final effluent BOD/TSS/NH4N concentrations of less than 15/15/1 mg/L. Biogas yield in the UASB reactor varied from 0.33 to 0.44 m3/kgCODremoved. The kinetics of anaerobic treatment were investigated. The yield coefficient was 0.03 gVSS/gCOD; maximum specific growth rate was 0.24 day(-1); Monod half velocity constant was 135 mgCOD/L; and specific substrate utilization rate was 3.25 gCOD/gVSS x d. Nitrification and denitrification kinetics were studied in batch experiments, and the rates were comparable with those in the continuous flow system.  相似文献   

14.
从接种液种类、空白 BOD5大小、接种液最佳添加范围等方面对 BOD5测定进行探讨 ,提出以接纳工业废水的河水作为最佳接种液 ,雨季时以土壤浸取液更适合。探讨了接种液空白值对 BOD5标液和工业废水的影响。结果表明 ,河水空白应控制在 0 .1~0 .8mg/ L,土壤浸取液空白控制在 0 .0 1~ 0 .1 0 mg/ L为宜。  相似文献   

15.
Fenton氧化-生化组合工艺处理染料中间体废水   总被引:9,自引:4,他引:9  
针对染料中间体废水具有COD高、BOD5/COD低和具有生物毒性的特性,采用Fenton氧化-水解酸化-好氧组合工艺进行染料中间体生产废水的处理试验,试验结果表明:废水经Fenton氧化及水解酸化工序后,废水的BOD5/COD值由0.03升高至0.48,经好氧生化工序处理后的出水COD和BOD5浓度分别达122.6 mg/L和54.6 mg/L,符合《污水综合排放标准》(GB8978-1996)二级标准,该组合工艺COD总去除率达94%.  相似文献   

16.
采用Fenton氧化与生化组合技术处理生物难降解的采油废水的研究结果表明 ,Fenton氧化技术不但对采油废水中有机质有较好的去除率 ,而且大大地改善了废水的可生化性 ,在H2 O2 的投加浓度和Fe2 + 与H2 O2 的摩尔比分别为10mmol/L和 0 .1的条件下 ,经过 30min氧化后可使废水BOD值由原来的 5mg/L上升至 4 0mg/L ;同时随着氧化时间的延长 ,废水中残余的有机物分子量逐渐降低。 30min氧化后的废水经过生物处理 ,其出水COD值为 10 2mg/L ,可以满足国家综合污水外排标准 ,经济分析结果表明 ,该技术处理采油废水的运行成本为 1 4 7元 /t。这一技术在解决石油行业采油废水的外排达标方面具有很好的应用前景。  相似文献   

17.
This paper describes results from a pilot study of a novel wastewater treatment technology, which incorporates nutrient removal and solids separation to a single step. The pseudoliquified activated sludge process pilot system was tested on grit removal effluent at flowrates of 29.4 to 54.7 m3/d, three different solid residence times (SRT) (15, 37, and 57 days), and over a temperature range of 12 to 28 degrees C. Despite wide fluctuations in the influent characteristics, the system performed reliably and consistently with respect to organics and total suspended solids (TSS) removals, achieving biochemical oxygen demand (BOD) and TSS reductions of > 96% and approximately 90%, respectively, with BOD5 and TSS concentrations as low as 3 mg/L. Although the system achieved average effluent ammonia concentrations of 2.7 to 3.2 mg/L, nitrification efficiency appeared to be hampered at low temperatures (< 15 degrees C). The system achieved tertiary effluent quality with denitrification efficiencies of 90 and 91% total nitrogen removal efficiency at a total hydraulic retention time of 4.8 hours and an SRT of 12 to 17 days. With ferric chloride addition, effluent phosphorous concentrations of 0.5 to 0.8 mg/L were achieved. Furthermore, because of operation at high biomass concentrations and relatively long biological SRTs, sludge yields were over 50% below typical values for activated sludge plants. The process was modeled using activated sludge model No. 2, as a two-stage system comprised an aerobic activated sludge system followed by an anoxic system. Model predictions for soluble BOD, ammonia, nitrates, and orthophosphates agreed well with experimental data.  相似文献   

18.
农药废水是一种典型的高浓度有机工业废水 ,有机污染物浓度高 (CODCr>10 0 0 0mg L) ,可生化性差 (氯苯农药废水BOD5 CODCr=0 .0 3 ,对邻硝基氯苯农药废水BOD5 CODCr=0 .0 5 )。采用微电解和Fenton试剂氧化两种物化手段对菊酯、氯苯和对邻硝氯苯 3种废水按比例配制而成的综合农药废水进行预处理 ,结果表明 :在废水pH为 2— 2 .5时 ,经微电解处理后 ,BOD5 CODCr比值在 0 .45以上 ,可生化性提高 ;Fenton试剂对综合农药废水CODCr去除率为 60 %左右 ,色度去除率接近 10 0 %  相似文献   

19.
Three wastewater samples from a pharmaceutical plant formulating medical ointments were subjected to lab-scale treatment by a Fenton-like system in combination with lime coagulation. All samples were plant pre-treated by adsorption/flocculation/filtration processes with utilization of bentonite, but the quality of effluents did not comply with the regulations for wastewater discharged to local sewerage. The optimization of Fenton-like oxidation demonstrated the highest process efficacy at H(2)O(2)/COD weight ratio of 2:1, H(2)O(2)/Fe(2+) molar ratio of 10:1 and 2h of treatment time. The fast pH decrease to acidic values approximately 3 during first min of oxidation for all effluents suggested that pH adjustment was unnecessary. Combination of Fe(III) precipitation and lime coagulation proved feasible to improve considerably COD and residual iron concentration reduction in pharmaceutical effluents. Additionally, considerable BOD(7) reduction and BOD(7)/COD ratio improvement of pharmaceutical wastewater samples was achieved by combined treatment. The application of Fenton-like oxidation with subsequent iron (III)/lime coagulation did not only enhance the quality of pharmaceutical effluents with different chemical characteristics and help to meet the requirements for wastewater discharged to sewage, but also improve the biodegradability of pharmaceutical effluents.  相似文献   

20.
三维电极/电-Fenton法降解苯酚   总被引:1,自引:0,他引:1  
采用电-Fenton耦合三维电极法处理苯酚模拟废水,研究了活性炭作为第三电极的三维电极体系中苯酚的去除效果,重点考察了常温下初始pH值、电流强度、Fe2+浓度等因素对苯酚降解的影响。结果表明:在常温下,曝气速率20 L/min,初始pH=3,电流强度为0.3 A/m2,Fe2+浓度为0.1 mmol/L,反应时间60 min时,废水的苯酚的氧化降解率为91%,COD去除率为64%。在此条件下,三维电极/电-Fenton表现出较强的氧化能力,具有较好的去除效果,可应用于含苯酚废水的处理。  相似文献   