首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 296 毫秒
1.
Parshetti GK  Doong RA 《Chemosphere》2012,86(4):392-399
In this study, the dechlorination of chlorinated hydrocarbons including trichloroethylene (TCE), tetrachloroethylene (PCE) and carbon tetrachloride (CT) by bimetallic Ni/Fe nanoparticles immobilized on four different membranes was investigated under anoxic conditions. Effects of several parameters including the nature of membrane, initial concentration, pH value, and reaction temperature on the dechlorination efficiency were examined. The scanning electron microscopic images showed that the Ni/Fe nanoparticles were successfully immobilized inside the four membranes using polyethylene glycol as the cross-linker. The agglomeration of Ni/Fe were observed in poly(vinylidene fluoride), Millex GS and mixed cellulose ester membranes, while a relatively uniform distribution of Ni/Fe was found in nylon-66 membrane because of its hydrophilic nature. The immobilized Ni/Fe nanoparticles exhibited good reactivity towards the dechlorination of chlorinated hydrocarbons, and the pseudo-first-order rate constant for TCE dechlorination by Ni/Fe in nylon-66 were 3.7-11.7 times higher than those in other membranes. In addition, the dechlorination efficiency of chlorinated hydrocarbons followed the order TCE > PCE > CT. Ethane was the only end product for TCE and PCE dechlorination, while dichloromethane and methane were found to be the major products for CT dechlorination, clearly indicating the involvement of reactive hydrogen species in dechlorination. In addition, the initial rate constant for TCE dechlorination increased upon increasing initial TCE concentrations and the activation energy for TCE dechlorination by immobilized Ni/Fe was 34.9 kJ mol−1, showing that the dechlorination of TCE by membrane-supported Ni/Fe nanoparticles is a surface-mediated reaction.  相似文献   

2.
Lee W  Batchelor B 《Chemosphere》2004,56(10):999-1009
Abiotic reductive dechlorination of chlorinated ethylenes (tetrachloroethylene (PCE), trichloroethylene (TCE), cis-dichloroethylene (c-DCE), and vinylchloride (VC)) by iron-bearing phyllosilicates (biotite, vermiculite, and montmorillonite) was characterized to obtain better understanding of the behavior of these contaminants in systems undergoing remediation by natural attenuation and redox manipulation. Batch experiments were conducted to evaluate dechlorination kinetics and some experiments were conducted with addition of Fe(II) to simulate impact of microbial iron reduction. A modified Langmuir-Hinshelwood kinetic model adequately described reductive dechlorination kinetics of target organics by the iron-bearing phyllosilicates. The rate constants stayed between 0.08 (+/-10.4%) and 0.401 (+/-8.1%) day(-1) and the specific initial reductive capacity of iron-bearing phyllosilicates for chlorinated ethylenes stayed between 0.177 (+/-6.1%) and 1.06 (+/-7.1%) microM g(-1). The rate constants for the reductive dechlorination of TCE at reactive biotite surface increased as pH (5.5-8.5) and concentration of sorbed Fe(II) (0-0.15 mM g(-1)) increased. The appropriateness of the model is supported by the fact that the rate constants were independent of solid concentration (0.0085-0.17 g g(-1)) and initial TCE concentration (0.15-0.60 mM). Biotite had the greatest rate constant among the phyllosilicates both with and without Fe(II) addition. The rate constants were increased by a factor of 1.4-2.5 by Fe(II) addition. Between 1.8% and 36% of chlorinated ethylenes removed were partitioned to the phyllosilicates. Chloride was produced as a product of degradation and no chlorinated intermediates were observed throughout the experiment.  相似文献   

3.
Biogeochemical reductive dechlorination (BiRD) is a new remediation approach for chlorinated aliphatic hydrocarbons (CAHs). The approach stimulates common sulfate-reducing soil bacteria, facilitating the geochemical conversion of native iron minerals into iron sulfides. Iron sulfides have the ability to chemically reduce many common CAH compounds including PCE, TCE, DCE, similar to zero valent iron (Fe(0)). Results of a field test at Dover Air Force Base, Dover, Delaware, are given in this paper. BiRD was stimulated by direct injection of Epson salt (MgSO(4).7H(2)O) and sodium (L) lactate (NaC(3)H(5)O(3)) in five injection wells. Sediment was sampled before and 8 months after injection. Significant iron sulfide minerals developed in the sandy aquifer matrix. From ground water analyses, treatment began a few weeks after injection with up to 95% reduction in PCE, TCE, and cDCE in less than 1 year. More complete CAH treatment is likely at a larger scale than this demonstration.  相似文献   

4.
5.
Bioremediation by reductive dehalogenation of groundwater contaminated with tetrachloroethene (PCE) or trichloroethene (TCE) is generally carried out through the addition of a fermentable electron donor such as lactate, benzoate, carbohydrates or vegetable oil. These fermentable donors are converted by fermenting organisms into acetate and hydrogen, either of which might be used by dehalogenating microorganisms. Comparisons were made between H2 and acetate on the rate and extent of reductive dehalogenation of PCE. PCE dehalogenation with H2 alone was complete to ethene, but with acetate alone it generally proceeded only about half as fast and only to cis-1,2-dichloroethene (cDCE). Additionally, acetate was not used as an electron donor in the presence of H2. These findings suggest the fermentable electron donor requirement for PCE dehalogenation to ethene can be reduced up to 50% by separating PCE dehalogenation into two stages, the first of which uses acetate for the conversion of PCE to cDCE, and the second uses H2 for the conversion of cDCE to ethene. This can be implemented with a recycle system in which the fermentable substrate is added down-gradient, where the hydrogen being produced by fermentation effects cDCE conversion into ethene. The acetate produced is recycled up-gradient to achieve PCE conversion into cDCE. With the lower electron donor usage required, potential problems of aquifer clogging, excess methane production, and high groundwater chemical oxygen demand (COD) can be greatly reduced.  相似文献   

6.
The distribution of methyl chloroform was determined (MCF), trichloroethylene (TRI) and tetrachloroethylene (PCE) in milk, tissues and expired air by intraruminally administering 0.625 ml kg(-0.75) of an equal-volume mixture of the three compounds to lactating goats. The milk secreted during 24 h after the intraruminal administration contained 1.42 mg of MCF, 1.87 mg of TRI, 6.43 mg of PCE and 0.33 mg of trichloroethanol (TCE). MCF, TRI and PCE appeared in the blood less than 30 min after administration. Oral administration of these chemicals to milk-fed kids showed that at 3.5 h post-administration, the liver contained these chemicals in greatest abundance. The adaptation of milk-fed kids to 3 weeks administration of small amounts of propylene glycol stimulated the metabolic conversion of TRI to TCE. There were linear relationships between the blood concentrations of these chemicals and the expiration rates after oral administration of 0.4 ml kg(-1) of each chemical to milk-fed kids. The expiration rates of MCF, TRI and PCE were 605, 122 and 46 microg min(-1) kg(-1) at 2 microg ml(-1) blood concentrations of MCF, TRI and PCE, respectively. These results suggested that MCF is little metabolized, being most readily exhaled in expired air, while PCE demonstrates the greatest tissue-partitioning, being largely secreted into the milk or retained in the liver. TRI can be extensively metabolized to other compounds such as TCE in milk-fed kids.  相似文献   

7.
A novel method to remediate dense nonaqueous phase liquid (DNAPL) source zones that incorporates in situ density conversion of DNAPL via alcohol partitioning followed by displacement with a low interfacial tension (IFT) surfactant flood has been developed. Previous studies demonstrated the ability of the density-modified displacement (DMD) method to recover chlorobenzene (CB) and trichloroethene (TCE) from heterogeneous porous media without downward migration of the dissolved plume or free product. However, the extent of alcohol (n-butanol) partitioning required for in situ density conversion of high-density NAPLs, such as tetrachloroethene (PCE), could limit the utility of the DMD method. Hence, the objective of this study was to compare the efficacy of two n-butanol delivery approaches: an aqueous solution of 6% (wt) n-butanol and a surfactant-stabilized macroemulsion containing 15% (vol) n-butanol in water, to achieve density reduction of PCE-NAPL in two-dimensional (2-D) aquifer cells. Results of liquid-liquid equilibrium studies indicated that density conversion of PCE relative to water occurred at an n-butanol mole fraction of 0.56, equivalent to approximately 5 ml n-butanol per 1 ml of PCE when in equilibrium with an aqueous solution. In 2-D aquifer cell studies, density conversion of PCE was realized using both n-butanol preflood solutions, with effluent NAPL samples exhibiting density reductions ranging from 0.51 to 0.70 g/ml. Although the overall PCE mass recoveries were similar (91% and 93%) regardless of the n-butanol delivery method, the surfactant-stabilized macroemulsion preflood removed approximately 50% of the PCE mass. In addition, only 1.2 pore volumes of the macroemulsion solution were required to achieve in situ density conversion of PCE, compared to 6.4 pore volumes of the 6% (wt) n-butanol solution. These findings demonstrate that use of the DMD method with a surfactant-stabilized macroemulsion containing n-butanol holds promise as an effective source zone remediation technology, allowing for efficient recovery of PCE-DNAPL while mitigating downward migration of the dissolved plume and free product.  相似文献   

8.
通过批实验和柱实验研究了三氯乙烯(TCE)初始浓度、四氯乙烯(PCE)等对零价铁去除三氯乙烯的影响,并建立了三氯乙烯降解的反应动力学方程。结果表明:(1)零价铁对TCE具有较好的降解效果,反应符合准一级反应动力学方程,表观反应速率常数随TCE浓度的增加而减小;(2)在铁粉充足的条件下,TCE初始浓度对降解效果影响不显著,且TCE去除率皆可达到90%以上;(3)PCE的存在抑制了TCE的脱氯反应。PCE和TCE共存时,TCE的最大去除率仅为64.2%;TCE脱氯反应的表观反应速率明显降低,反应半衰期由TCE单独存在时的6.8~9.7 h增大到66 h~346.5 h。  相似文献   

9.
Liang C  Bruell CJ  Marley MC  Sperry KL 《Chemosphere》2004,55(9):1213-1223
The objective of the laboratory study is to examine the conditions under which transition metal ions (e.g., ferrous ion, Fe2+) could activate the persulfate anion (S2O8(2)-) to produce a powerful oxidant known as the sulfate free radical (SO4-*) with a standard redox potential of 2.6 V. The SO4-* is capable of destroying groundwater contaminants in situ such as trichloroethylene (TCE). Experiments using Fe2+ as an activator under various molar ratios of S2O8(2)-/Fe2+/TCE in an aqueous system indicated that partial TCE degradation occurred almost instantaneously and then the reaction stalled. Either destruction of SO4-* in the presence of excess Fe2+ or the rapid conversion of all Fe2+ to Fe3+ limited the ultimate oxidizing capability of the system. Sequential addition of Fe2+ in small increments resulted in an increased TCE removal efficiency. Therefore, it appeared that Fe2+ played an important role in generating SO4-*. An observation of oxidation-reduction potential (ORP) variations revealed that the addition of sodium thiosulfate (Na2S2O3) to the ferrous ion activated persulfate system could significantly decrease the strong oxidizing conditions. It was hypothesized that the thiosulfate induced reducing conditions might convert Fe3+ to a lower valence state of Fe2+, making the Fe2+ available to activate persulfate decomposition. The sequential addition of thiosulfate (S2O3(2)-), after the initial stalling of ferrous ion activated persulfate oxidation of TCE, resulted in an improvement in TCE removal. The ferrous ion activated persulfate-thiosulfate redox couple resulted in fairly complete TCE degradation in aqueous systems in a short time frame. In soil slurry systems, TCE degradation was slower in comparison to aqueous systems.  相似文献   

10.
Costanza J  Pennell KD 《Chemosphere》2008,71(11):2060-2067
The rates of hydrolysis reported for tetrachloroethylene (PCE) and trichloroethylene (TCE) at elevated temperatures range over two orders-of-magnitude, where some of the variability may be due to the presence of a gas phase. Recent studies suggest that volatile organic analysis (VOA) vials provide a low-cost and readily available zero headspace system for measuring aqueous-phase hydrolysis rates. This work involved measuring rates of PCE and TCE disappearance and the corresponding appearance of dechlorination products in water-filled VOA vials and flame-sealed ampules incubated at 21 and 55 °C for up to 95.5 days. While PCE and TCE concentrations readily decreased in the VOA vials to yield first-order half lives of 11.2 days for PCE and 21.1 days for TCE at 55 °C, concentrations of anticipated dechlorination products, including chloride, remained constant or were not detected. The rate of PCE disappearance was 34 times faster in VOA vials at 55 °C compared to values obtained with flame-sealed ampules containing PCE-contaminated water. In addition, the concentration of TCE increased slightly in flame-sealed ampules incubated at 55 °C, while a decrease in TCE levels was observed in the VOA vials. The observed losses of PCE and TCE in the VOA vials were attributed to diffusion and sorption in the septa, rather than to dechlorination. These findings demonstrate that VOA vials are not suitable for measuring rates of volatile organic compound hydrolysis at elevated temperatures.  相似文献   

11.
A fully automated twin ECD gas chromatograph system with sample enriching adsorption–desorption primary stage was deployed on two field campaigns – Ny-Ålesund, Svalbard, Arctic Norway (July–September 1997), and the RRS Discovery CHAOS cruise of the northeast Atlantic (April–May 1998). Concentrations of an extensive set of halocarbons were detected at hourly intervals at pptv levels. We present here the results obtained for the chlorinated solvents, tetrachloroethene (PCE) and trichloroethene (TCE). Average baseline PCE and TCE concentrations of 1.77 and 0.12 pptv, respectively, were recorded in Ny-Ålesund. During pollution incidences, concentrations rose to 5.61 (PCE) and 3.18 pptv (TCE). The cruise data showed average concentrations ranging from 4.26 (PCE) and 1.66 pptv (TCE) for air masses originating over the North Atlantic and Arctic open oceans, to maxima of 15.59 (PCE) and 17.51 pptv (TCE) for polluted air masses from Northern Europe. The data sets emphasise the difficulties in defining remote sites for background tropospheric halocarbon measurements, as Ny-Ålesund research station proved to be a source of tetrachloroethene. The data also suggest possible oceanic emissions of trichloroethene in the sub-tropical ocean.  相似文献   

12.
The widespread use of tetrachloroethene (PCE) and trichloroethene (TCE) as dry cleaning solvents and degreasing agents for military and industrial applications has resulted in significant environmental contamination worldwide. Anaerobic biotransformation of PCE and TCE through reductive dechlorination frequently lead to the accumulation of dichloroethenes (DCEs), thus limiting the use of reductive dechlorination for the biotransformation of the compounds. In this study, seven bacteria indigenous to contaminated sites in Africa were characterized for DCE degradation under aerobic conditions. The specific growth rate constants of the bacterial isolates ranged between 0.346-0.552d(-1) and 0.461-0.667d(-1) in cis-DCE and trans-DCE, respectively. Gas chromatographic analysis revealed that up to 75% of the compounds were degraded within seven days with the degradation rate constants ranging between 0.167 and 0.198d(-1). The two compounds were also observed to be significantly degraded, simultaneously, rather than sequentially, when present as a mixture. Phylogenetic analysis of the 16S rRNA gene sequences of the bacterial isolates revealed their identity as well as their relation to other environmentally-important bacteria. The observed biodegradation of DCEs may contribute to PCE and TCE removal at the aerobic fringe of groundwater plumes undergoing reductive dechlorination in contaminated sites.  相似文献   

13.
The variability of stable carbon isotope fractionation upon reductive dechlorination of tetra- and trichloroethene by several microbial strains was investigated to examine the uncertainties related to the in situ application of compound specific isotope analysis (CSIA) of chlorinated ethenes. Carbon isotope fractionation was investigated with a set of microorganisms representative for the currently known diversity of dehalorespirers: Dehalococcoides ethenogenes strain 195, Desulfitobacterium sp. strain Viet1, Desulfuromonas michiganensis and Geobacter lovleyi sp. strain SZ and compared to the previous reports using Sulfurospirillum spp. and Desulfitobacterium sp. strain PCE-S. Carbon isotope fractionation of tetrachloroethene (PCE) and trichlorethene (TCE) was highly variable ranging from the absence of significant fractionation to carbon isotope fractionation (epsilonC) of 16.7 and 3.5-18.9 for PCE and TCE, respectively. Fractionation of both compounds by D. ethenogenes strain 195 (PCE: epsilonC=6.0; TCE: epsilonC=13.7) was similar to the literature data for mixed cultures containing Dehalococcoides spp. D. michiganensis (PCE: no significant fractionation; TCE: epsilonC=3.5) and G. lovleyi sp. strain SZ (PCE no significant fractionation; TCE: epsilonC=8.5) generated the lowest fractionation of all studied strains. Desulfitobacterium sp. strain Viet1 (PCE: epsilonC=16.7) gave the highest enrichment factor for PCE.  相似文献   

14.
In situ chemical oxidation (ISCO) is considered a reliable technology to treat groundwater contaminated with high concentrations of organic contaminants. An ISCO oxidant, persulfate anion (S(2)O(8)(2-)) can be activated by ferrous ion (Fe(2+)) to generate sulfate radicals (E(o)=2.6 V), which are capable of destroying trichloroethylene (TCE). The property of polarity inhibits S(2)O(8)(2-) or sulfate radical (SO(4)(-)) from effectively oxidizing separate phase TCE, a dense non-aqueous phase liquid (DNAPL). Thus the oxidation primarily takes place in the aqueous phase where TCE is dissolved. A bench column study was conducted to demonstrate a conceptual remediation method by flushing either S(2)O(8)(2-) or Fe(2+) through a soil column, where the TCE DNAPL was present, and passing the dissolved mixture through either a Fe(2+) or S(2)O(8)(2-) fluid sparging curtain. Also, the effect of a solubility enhancing chemical, hydroxypropyl-beta-cyclodextrin (HPCD), was tested to evaluate its ability to increase the aqueous TCE concentration. Both flushing arrangements may result in similar TCE degradation efficiencies of 35% to 42% estimated by the ratio of TCE degraded/(TCE degraded+TCE remained in effluent) and degradation byproduct chloride generation rates of 4.9 to 7.6 mg Cl(-) per soil column pore volume. The addition of HPCD did greatly increase the aqueous TCE concentration. However, the TCE degradation efficiency decreased because the TCE degradation was a lower percentage of the relatively greater amount of dissolved TCE by HPCD. This conceptual treatment may serve as a reference for potential on-site application.  相似文献   

15.
Kang N  Hua I  Rao PS 《Chemosphere》2006,63(10):1685-1698
The Fenton's system is applied to the destruction of perchloroethylene (PCE) present as a dense non-aqueous phase liquid (DNAPL) in soil slurry systems; the initial concentration of PCE was 45 times higher than its aqueous solubility. Studies were conducted in two matrices: Ottawa sand and soil from Warsaw, IN. In Ottawa sand, a 60-62% decrease in PCE concentration was observed, and Cl(-) recovery was 47-58%, whereas in Warsaw soil, a 44-49% decrease in PCE concentration and a Cl(-) recovery of 40-42% were observed after the addition of 600 mM H(2)O(2) and 10 mM dissolved iron. Significantly enhanced destruction resulted during application of N-(2-hydroxyethyl) iminodiacetic acid (HEIDA) to Warsaw soil. For example, in the absence of HEIDA in Warsaw soil, 36% PCE loss and 33% Cl(-) release were observed at 600 mM H(2)O(2) and 5 mM Fe(III), while 74% PCE loss and 63% Cl(-) release were achieved at 600 mM H(2)O(2) and 5 mM Fe(III)-HEIDA. For both soils, the catalytic activities of Fe(II) and Fe(III) were nearly equivalent. These findings clearly demonstrate that system design can be optimized with regard to process variables in Fenton's treatment of DNAPL in soils.  相似文献   

16.
Cho HH  Park JW 《Chemosphere》2006,64(6):1047-1052
Effects of surfactants and natural organic matter (NOM) on the sorption and reduction of tetrachloroethylene (PCE) with zero valent iron (ZVI) were examined in this study. PCE reduction by ZVI depended on the ionic type of the surfactants. The removal of PCE and production of TCE with non-ionic Triton X-100 and cationic hexadecyltrimethyl-ammonium (HDTMA) at one-half and two times the critical micelle concentration (CMC) were 1.2-1.8 times higher than without surfactants because of the enhanced PCE partitioning and surface concentration by the sorbed surfactants. When anionic sodium dodecyl benzene sulfonate (SDDBS) at one-half and two times CMC and NOM at 20 mg l(-1) and 50 mg l(-1) concentrations were used, the removal of PCE doubled and TCE production decreased. In the presence of SDDBS, TCE production by ZVI was lower than with HDTMA and Triton X-100 while PCE removal was higher than with the other surfactants.  相似文献   

17.
Jung B  Batchelor B 《Chemosphere》2008,71(4):726-734
Transformation of 1,1,2,2-tetrachloroethane (1,1,2,2-TeCA) by Fe(II) in 10% cement slurries was characterized using a batch reactor system. 1,1,2,2-TeCA was completely converted to trichloroethylene (TCE) within 1h in all experiments, even in controls with cement that did not include Fe(II). Therefore, complete degradation of 1,1,2,2-TeCA depends on the behavior of TCE. The half-life of TCE was observed to be 15d when concentrations of Fe(II) and 1,1,2,2-TeCA were 98mM and 0.245mM, respectively. The kinetics of TCE removal was observed to be dependent on Fe(II) dose, pH and initial substrate concentration. Pseudo-first-order rate constants linearly increased with Fe(II) dose up to 198mM when initial target concentration was 0.245mM. Pseudo-first-order kinetics generally described the degradation reactions of TCE at a specific initial concentration, but a modified Langmuir-Hinshelwood model was necessary to describe the degradation kinetics of TCE over a wide range of initial concentrations. A surface reaction of TCE on active solids, which were formed from Fe(II) and products of cement hydration appears to control observed TCE degradation kinetics.  相似文献   

18.
Jung J  Yoon JH  Chung HH  Lee MJ 《Chemosphere》2003,51(9):881-885
The effects of H(2)O(2) and O(3) on the decomposition of trichloroethylene (TCE) and perchloroethylene (PCE) by gamma-rays (gamma-rays) were investigated in this work. The combined gamma-rays/O(3) process showed a synergistic effect and enhanced the removal of TCE and PCE compared with gamma-rays alone, but, the gamma-rays/H(2)O(2) process did not increase the removal. This interesting result was successfully identified by an electron paramagnetic resonance spectroscopy/spin-trapping method that can quantify hydroxyl radicals, which is directly related to the efficiency of TCE and PCE decomposition. For gamma-rays/H(2)O(2) system, there was no difference of hydroxyl radical production between gamma-rays alone and gamma-rays/H(2)O(2). This indicates gamma-rays cannot activate H(2)O(2) to produce hydroxyl radicals and this causes no increase of TCE and PCE removals. To the contrary, the production of hydroxyl radicals was obviously increased in the case of gamma-rays/O(3) process. This suggests additional hydroxyl radicals are produced from the reaction of O(3) with the irradiation products of water such as hydrated electrons, hydrogen atoms, etc. and this accelerates the removal of TCE and PCE.  相似文献   

19.
Stable hydrogen isotopes of two chlorinated solvents, trichloroethylene (TCE) and 1,1,1-trichloroethane (TCA), provided by five different manufacturers, were determined and compared to their carbon and chlorine isotopic signatures. The isotope ratio for delta2H of different TCEs ranged between +466.9 per thousand and +681.9 per thousand, for delta13C between -31.57 per thousand and -27.37 per thousand, and for delta37Cl between -3.19 per thousand and +3.90 per thousand. In the case of the TCAs, the isotope ratio for delta2H ranged between -23.1 per thousand and +15.1 per thousand, for delta13C between -27.39 per thousand and -25.84 per thousand, and for delta37Cl between -3.54 per thousand and +1.39 per thousand. As well, a column experiment was carried out to dechlorinate tetrachloroethylene (PCE) to TCE using iron. The dechlorination products have completely different hydrogen isotope ratios than the manufactured TCEs. Compared to the positive values of delta2H in manufactured TCEs (between +466.9 per thousand and +681.9 per thousand), the dechlorinated products had a very depleted delta2H (less than -300 per thousand). This finding has strong implications for distinguishing dechlorination products (PCE to TCE) from manufactured TCE. In addition, the results of this study show the potential of combining 2H/1H analyses with 13C/12C and 37Cl/35Cl for isotopic fingerprinting applications in organic contaminant hydrogeology.  相似文献   

20.
The effect of nitrate on the reduction of TCE by commercial granular iron was investigated in column experiments designed to allow for the in situ monitoring of the iron surface film with Raman spectroscopy. Three column experiments were conducted; one with an influent solution of 100 mg/l nitrate+1.5 mg/l TCE, and two control columns, one saturated directly with 100 mg/l nitrate solution, the other pre-treated with Millipore water prior to the introduction of a 100 mg/l nitrate solution. In the presence of nitrate, TCE adsorbed onto the iron, but there was little TCE reduction to end-products ethene and ethane. The iron used (Connelly, GPM, Chicago) is a product typical of those used in permeable granular iron walls. The material is covered by an air-formed high-temperature oxidation film, consisting of an inner layer of Fe(3)O(4), and an outer, passive layer of Fe(2)O(3). In the control column pre-treated with Millipore water, the passive Fe(2)O(3) layer was removed upon contact with the water in a manner consistent with an autoreduction reaction. In the TCE+nitrate column and the direct nitrate saturation column, nitrate interfered with the removal of the passive layer and maintained conditions such that high valency protective corrosion species, including Fe(2)O(3) and FeOOH, were stable at the iron surface. The lack of TCE reduction is explained by the presence of these species, as they inhibit both mechanisms proposed for TCE reduction by iron, including catalytic hydrogenation, and direct electron transfer.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号