首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The aim of this research was to study the on-site anaerobic treatment of a medium-strength residential wastewater in a pilot-scale up-flow septic tank (UST). The effects of three different hydraulic retention times (HRTs) of 24, 12 and 6 h on the UST performance were investigated. The UST removed 85, 77, and 86% of biochemical oxygen demand (BOD5), chemical oxygen demand (COD) and total suspended solids (TSS), respectively, at steady state operation and with a 24 h HRT. Decreasing the HRT to 12 and then 6 h resulted in deteriorated effluent quality and significantly reduced reactor performance. The sludge showed a high specific methanogenic activity (SMA) of 15.2 mL CH4 g?1 VSS d?1 with raw wastewater substrate. The solids accumulated in the tank by the end of the experiment had a VSS/TSS of 0.57, demonstrating significant stabilization. Overall, the UST is concluded to be a technically and economically promising alternative to conventional septic tanks for the on-site decentralized treatment of residential wastewater, particularly in the rural communities of developing countries.  相似文献   

2.
Concerning the high volume of wastewater containing dye in Iran and its adverse effects, it is necessary to develop scientific solutions for treating these wastewaters. The aim of this study was to evaluate the efficiency of the alumina-coated multi-walled carbon nanotubes in removing the Reactive Red 198 (RR 198) and Blue 19 (RB 19) dyes. Synthetic samples including dye with different concentrations were prepared. These samples were put in contact with different contents of alumina/multi-walled carbon nanotubes, in different pH values, in different contact times, different temperatures and the presence of sodium sulfate or sodium carbonate. The optimum pH, dye concentration and temperature for removal of the two dyes was 3, 50 mg l−1 and 25 °C, respectively. The optimum adsorbent dose for removal the RR 198 dye was 0.5 g l−1 and for Blue 19 was 0.4 g l−1. The optimum contact time for RR 198 was 150 min and RB 19 was 180 min. In this condition, maximum removal efficiency for RR 198 and RB 19 was 91.54% and 93.51%, respectively. The adsorption study was analyzed kinetically, and the results revealed that the adsorption fitted a pseudo-second order kinetic model. According to these results alumina/multi-walled carbon nanotubes can effectively remove RR 198 and RB 19 from aqueous solutions.  相似文献   

3.
A bio-contact oxidation reactor integrated with filter bed (COR-FB) was developed for decentralized treatment of sewage, which consisted of a biofilm reactor and a gravitational filter bed. It has been investigated to treat municipal wastewater for reuse. The evaluation of COR-FB performance demonstrates that it produced good quality effluent regarding carbonaceous compound, nitrogenous compound, suspended solid and fecal coliform. The efficiencies of COD, NH4+-N, TN, TP and turbidity removal were 90.7%, 81.4%, 64.6%, 60.1% and 96.7%, respectively. The residual geometric mean of fecal coliform counts in the final effluent of COR-FB was only 7.8 × 103 MPN/103 ml, corresponding to removal value of 3.8 log 10. However, TP removal indicates the necessity of an addition of a bagger and mud valve or an enhanced chemical phosphorus removal prior to treated water reuse. Microfauna communities were monitored in COR-FB, which was found to contain 5 genres and 19 species in the biofilm layer. Also, a simple kinetics model for COR-FB was developed based on the influent, effluent soluble COD concentration and the reaction time by regression simulation. In general, available data proved that COR-FB system can be recommended as a compact and cost-effective technology for decentralized treatment of sewage, especially for developing countries.  相似文献   

4.
This paper presents the results of a study of a sludge subjected to the (ATAD) process – Autothermal Thermophilic Aerobic Digestion occurring in a two-stage installation operated in a municipal wastewater treatment plant in Olecko, Poland. The study of the sludge and the analysis of obtained results were conducted over 2011 and 2014. The subject of the study was a thickened sludge in an intermediate tank from which it was next transferred to facility reactors. The stabilization of processed sludge was evaluated analyzing the change in the dry mass (DS) content in the sludge. Measurements were carried out in thickened sludge samples and after the ATAD process. Collected results were then subjected to a statistical analysis and it was determined to which extent as resulted from the subject process the dry mass and the dry organic mass (VS) content was changing in the sludge. Also, it was analyzed how the oxygen chemical demand (COD) was changing. The dry mass content in the thickened sludge was from 60 g/l to 160 g/l. After the process, this amount was from 35 to 76 g/l. Similarly, the organic mass content in a dry sludge mass changed from initial values within a range of 44–135 g/l to 23–60 g/l after the ATAD process. Also, the organic substance content expressed as COD decreased from 80 to 467 g O2/l in a thickened sludge to 51–261 g O2/l in the sludge after the process. The article presents conclusions from the result of the conducted study as well as personal experience.  相似文献   

5.
Oxidative disintegration of municipal waste activated sludge (WAS) using conventional Fenton (Fe2+ + H2O2, CFP) and Fenton type (Fe0 + H2O2, FTP) processes was investigated and compared in terms of the efficiency of sludge disintegration and enhancement of anaerobic biodegradability. The influences of different operational variables namely sludge pH, initial concentration of Fe2+ or Fe0, and H2O2 were studied in detail. The optimum conditions have been found as catalyst iron dosage = 4 g/kg TS, H2O2 dosage = 40 g/kg TS and pH = 3 within 1 h oxidation period for both CFP and FTP. Kinetics studies were performed under optimal conditions. It was determined that the sludge disintegration was happened in two stages by both processes: rapid and subsequent slow disintegration stages and rapid sludge disintegration stage can be described by a zero-order kinetic model. The effects of oxidative sludge disintegration under the optimum conditions on anaerobic digestion were experienced with biochemical methane potential (BMP) assay in batch anaerobic reactors. Total methane production in the CFP and FTP pre-treated reactors increased by 26.9% and 38.0%, relative to the untreated reactor (digested the raw WAS). Furthermore, the total chemical oxygen demand reductions in the pre-treated reactors were improved as well.  相似文献   

6.
The start-up and operation of a partial nitritation sequencing batch reactor for the treatment of landfill leachate were carried out on intermittent aeration mode. Partial nitrite accumulation was established in 15 days after the mode was changed from continuous aeration to intermittent aeration. Despite the varying influent composition, partial nitritation could be maintained by adjusting the hydraulic retention time (HRT) and the air flow rate. An increase in the air flow rate together with a decrease in air off duration can improve the partial nitritation capacity and eventually result in the development of granular sludge with fine diameters. A nitrogen loading rate of 0.71 ± 0.14 kg/m3/d and a COD removal rate of 2.21 ± 0.13 kg/m3/d were achieved under the conditions of an air flow rate of 19.36 ± 1.71 m3 air/m3/h and an air on/off duration of 1.5 min/0.7 min. When the ratio of total air flux (TAF) to the influent loading rate (ILR) was controlled at the range of 163–256 m3 air/kg COD, a stable effluent NO3?–N/NOx?–N (NO2?–N plus NO3?–N) ratio below 13% was achieved. Interestingly, the effluent pH was found to be a good indicator of the effluent NO2?–N/NH4+–N ratio, which is an essential parameter for a subsequent anaerobic ammonium oxidation (Anammox) reactor.  相似文献   

7.
The present study reported a method for removal of As(III) from water solution by a novel hybrid material (Ce-HAHCl). The hybrid material was synthesized by sol–gel method and was characterized by XRD, FTIR, SEM–EDS and TGA–DTA. Batch adsorption experiments were conducted as a function of different variables like adsorbent dose, pH, contact time, agitation speed, initial concentration and temperature. The experimental studies revealed that maximum removal percentage is 98.85 at optimum condition: pH = 5.0, agitation speed = 180 rpm, temperature = 60 °C and contact time = 80 min using 9 g L−1 of adsorbent dose for initial As(III) concentration of 10 mg L−1. Using adsorbent dose of 10 g L−1, the maximum removal percentage remains same with initial As(III) concentration of 25 mg L−1 (or 50 mg L−1). The maximum adsorption capacity of the material is found to be 182.6 mg g−1. Subsequently, the experimental results are used for developing a valid model based on back propagation (BP) learning algorithm with artificial neural networking (BP-ANN) for prediction of removal efficiency. The adequacy of the model (BP-ANN) is checked by value of the absolute relative percentage error (0.293) and correlation coefficient (R2 = 0.975). Comparison of experimental and predictive model results show that the model can predict the adsorption efficiency with acceptable accuracy.  相似文献   

8.
The individual and simultaneous effects of acid and ultrasonic pretreatment on the disintegration of municipal waste activated sludge (WAS) were investigated based on chemical properties of WAS. In the combination of acid and ultrasonic pretreatment methods (ultrasonic-acid pretreatment), lowering pH accelerated and enhanced the disintegration of waste biological sludge. Therefore, the same disintegration efficiency (obtained by ultrasonic pretreatment alone) was achieved by the combined pretreatment in shorter sonication times. Optimum pretreatment conditions were ultrasonic power density of 1.0 W/mL and pretreatment time of 10 min for ultrasonic pretreatment alone, and ultrasonic power density of 1.0 W/mL, pretreatment time of 10 min and initial sludge pH of 2.0 for the combined pretreatment. Sludge disintegration degrees were about 30% and 40% under these optimized conditions, respectively. Optimum sludge concentration was found to be 1.0% total solid (TS) content for the combined pretreatment. As a result, ultrasonic-acid pretreatment has been determined as a new and effective combined sludge pretreatment method to improve the sludge disintegration.  相似文献   

9.
Vinasse has great pollution to the environment. A number of technologies have been explored for reducing the pollution of vinasse. Sustainability has become an important factor when discussing wastewater treatment techniques. Emergy analysis was used to evaluate the treatment of cassava vinasse in this paper. Cr (emergy consumption ratio) as a new emergy index was proposed to measure the impact of waste treatment to the society. Centrifugal solid–liquid separation, UASB (up-flow anaerobic sludge bed), and SBR (sequencing batch reactor activated sludge process) are used in the treatment process. The emergy indices for cassava vinasse treatment system were as follows: EYR (emergy yield ratio) was 6.20, ELR (environmental loading ratio) was 5.81, ESI (emergy sustainability index) was 1.07, and Cr was 4.60E+12 sej/m3. The emergy of coal electricity accounts for 46% of all purchased inputs. It is necessary to improve the treatment technology to reduce the electricity used.  相似文献   

10.
Produced water is the largest wastestream of oil and gas exploration but its chemical composition hinders its beneficial use. Effective treatment and reuse of produced water can mitigate scarcity of fresh water, especially in arid areas. Presence of inorganic compounds such as boron in produced water renders its beneficial use difficult. In this study, boron removal from produced water was investigated. Synthetic wastewater was prepared simulating the range of boron concentrations in produced water. Four operating parameters pH (3–11), charge loading (1200–3600 Ah/m3), contact time (15–90 min) and concentration (10–30 mg/L) were selected and their optimum conditions investigated. The obtained optimum conditions were applied to treat real produced water. Residual boron concentration of 0.3 mg/L was obtained from initial boron concentration of 15 mg/L in real produced water at optimum conditions of pH 7, charge loading 2400 Ah/m3 and contact time 90 min. Boron adsorption could be represented by Langmuir and Freundlich isotherm models. Electrocoagulation can be used for the effective removal of boron from produced water.  相似文献   

11.
The potential to remove Pb(II) ion from wastewater treatment systems using raw and treated maize stover through adsorption was investigated in batch experiments. To achieve this, batch mode experiments were conducted choosing specific parameters such as pH (2–8), dosage concentration (2–30 g L−1), contact time (5–180 min), temperature (20–45 °C) and metal ion concentrations (10–50 mg L−1). Adsorption was pH-dependent showing a maximum at pH value 5. The equilibrium sorption capacities of raw and treated maize stover were 19.65 and 27.10 mg g−1, respectively. The adsorption data fitted well to the Langmuir isotherm model. Kinetic studies revealed that the adsorption process followed pseudo-second-order model. The calculated thermodynamic parameters showed that the adsorption of Pb(II) was spontaneous and exothermic in nature. Consequently, this study demonstrated that both raw and treated maize stover could be used as adsorbents for the treatment of Pb(II) from industrial wastewaters.  相似文献   

12.
介绍了UASB反应器处理玉米淀粉废水的效果,分析了主要因素对处理效果的影响。淀粉废水处理实际工程的运行数据表明,UASB反应器处理玉米淀粉废水具有稳定的处理效果,COD去除率在83%以上,BOD5去除率在90%以上,出水满足后续好氧处理工艺的要求;有机负荷、pH值、碱度、出水循环、SO42-和悬浮物等是影响处理效果和颗粒污泥形成及其性质的几个关键因素。  相似文献   

13.
Biodegradability enhancement of landfill leachate using air stripping followed by coagulation/ultrafiltration (UF) processes was introduced. The air stripping process obtained a removal efficiency of 88.6% for ammonia nitrogen (NH4–N) at air-to-liquid ratio of 3500 (pH 11) for stripping 18 h. The single coagulation process increased BOD/COD ratio by 0.089 with the FeCl3 dosage of 570 mg l?1 at pH 7.0, and the single UF process increased the BOD/COD ratio to 0.311 from 0.049. However, the combined process of coagulation/UF increased the BOD/COD ratio from 0.049 to 0.43, and the final biological oxygen demand (BOD), chemical oxygen demand (COD), NH4–N and colour of leachate were 1223.6 mg l?1, 2845.5 mg l?1, 145.1 mg l?1 and 2056.8, respectively, when 3 kDa molecular weight cut-off (MWCO) membrane was used at the operating pressure 0.7 MPa. In ultrafiltration process, the average solution flux (JV), concentration multiple (MC) and retention rate (R) for COD was 107.3 l m?2 h?1, 6.3% and 84.2%, respectively.  相似文献   

14.
The aim of this research was to upgrade the performance of a conventional septic tank (CST) for on-site treatment of sewage with negligible costs. Although CST is known as an inexpensive pre-treatment system, a complementary treatment is required to reuse its output effluent. In this work, the quality of treated wastewater reached to the standard level for irrigation by the innovational changes made in the structure of CST for converting it into an advanced septic reactor (ASR). The modification consists adding some pipe and trays without using any mechanical or electrical equipment.ASR was operated at ambient temperatures in laboratory and pilot-scale. The effects of up-flow velocities (Vup) of 0.4, 0.5, 0.7, 1 and 1.5 m/h and hydraulic retention times (HRT) of 36, 24 and 12 h on the ASR treatment performance were studied.For optimum Vup of 1 m/h and HRT of 24 h and biomass specific methanogenic activity (SMA) of 0.31 mg COD/g VSS d the maximum removal of chemical oxygen demand (COD), biochemical oxygen demand (BOD5) and total suspended solids (TSS) were 86.2%, 79.4% and 95%, respectively.The results showed that ASR is an appropriate alternative for CST for sewage on-site treatment by a low cost modification.  相似文献   

15.
The effect of different carbon anodes was examined in a new design of single chambered microbial fuel cell (SCMFC). The new cell design used a low-cost hydrophilic membrane to replace costly proton exchange membranes and carbon felt and a range of carbon and modified carbon anodes were investigated. The fuel for the SCMFC was brewery wastewater which was diluted with domestic wastewater and the presented microflora acts as a source of electro-active bacteria. The membrane acts as a separator between the anode chamber and an air cathode and allows the transfer of ions based on the wastewater's natural conductivity. The air cathode was carbon black (Ketjen Black EC 300J) which was deposited (1 mg cm−2 concentration) directly onto the surface of the separator (one side of the membrane). Steady state polarization demonstrated maximum power densities of up to 30 mW m−2 and a steady state power density of 20 mW cm−2 at a current density of 110 mA m−2 was achieved. The best performing anodes were made from carbon modified with quinone/quinoid groups. With unmodified graphite felt (the control anode material) as anode, the maximal power density obtained was 9.5 mW m−2.  相似文献   

16.
In this research, treatability of high-load compost leachate in a hybrid expanded granular sludge bed (EGSB) and fixed-bed (FB) bioreactor followed by electrocoagulation–flotation (ECF) system was examined. The operational factors in EGSB–FB were influent chemical oxygen demand (COD), hydraulic retention time (HRT) and COD/nitrogen ratio (COD/N). And, their interactive effects on the efficiency of COD removal and biogas production rate (BPR) as responses were analyzed and correlated by response surface methodology (RSM). The optimum conditions of the hybrid EGSB–FB reactor were acquired at COD = 7800 mg/L, HRT = 35 h, COD/N = 70, in which COD removal efficiency was 83% and BPR 94 mL/h. The amount of confidence interval was 95%. COD (relevant coefficient = 9.8) and HRT (relevant coefficient = −24) were resulted respectively as the most effective parameters on COD removal and BPR. Yet, COD/N parameter imposed negative effect on COD removal and BPR in values less than about 100. The outcomes indicated that operated ECF as post-treatment in constant conditions (electrolysis time = 75 min, electrodes distance = 3 cm, voltage = 20 V) successfully satisfied discharge criteria in the most part of experimental domains.  相似文献   

17.
Treatment of Methyl Orange (MO), an azo dye, synthetic wastewater by electrocoagulation with periodic reversal of the electrodes (PREC) was examined. Response Surface Methodology (RSM) was used to optimize the influence of experimental conditions for color removal (CR), energy consumption (ENC), electrode consumption (ELC) and sludge production (SP) per kg MO removed (kg(MOr)) with optimal conditions being found to be pH 7.4, solution conductivity (к) 9.4 mS cm−1, cell voltage (U) 4.4 V, current density (j) 185 mA cm−2, electrocoagulation time (T) 14 min, cycle of periodic reversal of electrodes (t) 15 s, inter-electrode distance (d) 3.5 cm and initial MO concentration of 125 mg L−1. Under these conditions, 97 ± 2% color was removed and ENC, ELC and SP were 44 ± 3 kWh kg(MOr)−1, 4.1 ± 0.2 kg(Al) kg(MOr)−1 and 17.2 ± 0.9 kg(sludge) kg(MOr)−1, respectively. With the enhanced electrochemical efficiency resulting from the periodic electrode reversal, the coefficients of increased resistance and decreased current density between the two electrodes in the PREC setup were 2.48 × 10−4 Ω cm−2 min−1 and 0.29 mA cm−2 min−1, respectively, as compared to 7.72 × 10−4 Ω cm−2 min−1 and 0.79 mA cm−2 min−1 as measured for the traditional electrocoagulation process. The rate constant of decolorization was also enhanced by 20.4% from 0.152 min−1 in the traditional electrocoagulation process to 0.183 min−1 in the PREC process. These performance characteristics indicate that the PREC approach may be more promising in terms of practical application, as a cost-effective treatment, than conventional electrocoagulation for textile dye removals.  相似文献   

18.
This paper presents the photo-catalytic degradation of real refinery wastewater from National Refinery Limited (NRL) in Karachi, Pakistan, using TiO2, ZnO, and H2O2. The pretreatment of the refinery effluent was carried out on site and pretreated samples were tested at 32–37 °C in a stirrer bath reactor by using ultra-violet photo oxidation process. The degradation of wastewater was measured as a change in initial chemical oxygen demand (COD) and with time. Optimal conditions were obtained for catalyst type, and pH. The titanium dioxide proved to be very effective catalysts in photo-catalytic degradation of real refinery wastewater. The maximum degradation achieved was 40.68% by using TiO2 at 37 °C and pH of 4, within 120 min of irradiations. When TiO2 was combined with H2O2 the degradation decreased to 25.35%. A higher reaction rate was found for titanium dioxide. The results indicate that for real refinery wastewater, TiO2 is comparatively more effective than ZnO and H2O2. The experiments indicated that first-order kinetics can successfully describe the photo-catalytic reaction. The ANOVA results for the model showed satisfactory and reasonable adjustment of the second-order regression model with the experimental data. The ANOVA results also showed that pH is significant than reaction time and catalyst dosage of TiO2; and in case of ZnO, reaction time is significant than pH and catalyst dosage. This study proves that real refinery wastewater reacts differently than synthetic refinery wastewater, oil field produced water or oil water industrial effluent.  相似文献   

19.
The feasibility of using endpoint pH control to achieve stable partial nitritation (PN) in an SBR for landfill leachate treatment was investigated. By imposing a fixed-time anoxia followed by variable-time aeration in an SBR cycle, successful partial nitritation was maintained for 182 days at a nitrogen loading rate of 0.30–0.89 kg/m3/day. The effluent NO2-N/NH4+-N ratio and the effluent NO3-N concentration were 1.30 ± 0.22 and 16 ± 9 mg/L, respectively. High free ammonia (FA) and low dissolved oxygen (DO) concentrations were inhibition factors of nitrate formation. The termination of aeration at a suitable endpoint pH was the key to achieve an effluent NO2-N/NH4+-N ratio close to the stoichiometric value. This endpoint pH control strategy represents practical potentials in the engineered application of combined PN–ANAMMOX processes.  相似文献   

20.
The biological aerated filter (BAF) system, a new alternative in drinking water treatment, was designed to remove NH4+–N and Mn2+ simultaneously. This study aimed to control the aeration time in the BAF system for simultaneous NH4+–N and Mn2+ removal to achieve the Malaysian effluent quality regulation for drinking water. The experiment was conducted under four strategies of S1, S2, S3 and S4. The results demonstrated that acceptable levels of NH4+–N and Mn2+ were achieved over a 6 h aeration period (S1), producing effluent concentrations of 0.7 mg/L (93.2% removal) and 0.08 mg/L (79.6% removal), respectively. At the initial treatment of S1 and S2, the dissolved oxygen (DO) level rapidly increased until it reached a saturated concentration (6.8 mg/L DO) after 2 h period. Automatic on–off aeration time to maintain 3 mg/L DO set point (S4) resulted with a good effluent quality of NH4+–N and Mn2+ compared with the 2 mg/L DO set point (S3) which did not meet the regulated standard limits. Through the automatic on–off aeration time, the saturated and excessive DO levels in the BAF system can be avoided consequently reduce the wastage of energy and electrical consumption for simultaneous NH4+–N and Mn2+ removal from drinking water treatment.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号