To further elucidate the influence mechanism of side vents on the dynamic characteristics of gas explosions in tubes is helpful to design more reasonable vent layouts. In this paper, 9.5% methane-air explosion experiments were conducted in a tube with two side-vented ducts, and the effects of vent layouts and vent areas on the dynamic characteristics of explosion overpressure and flame propagation speed were investigated. The results demonstrate that under the same condition with a single vent area of 100 mm × 100 mm, when only the end vent is open, the maximum explosion overpressure and the maximum flame propagation speed are the highest among the five vent layouts. When the side vents 1 and 2 and the end vent are open, the maximum explosion overpressure is the lowest, and an unusual discovery is that the flame front changes into a hemispherical shape, finger shape, quasi-plane shape, tulip shape and wrinkled structure. When only side vent 1 is open, a unique Helmholtz oscillation occurs, and a new discovery is that there is a consistent oscillation relationship among the overpressure, flame propagation speed and flame structure. Helmholtz oscillation occurs only when a single vent area is 100 mm × 100 mm–60 mm × 60 mm, and the oscillation degree decreases with decreasing vent area. During the vent failure stage, the maximum explosion overpressure is generated, the flame front begins to appear irregular shape, and the flame propagation speed shows a prominent characteristic peak. After the vent failure stage, the driving effect of the end vent on the flame is higher than that of the side vent on the flame. Furthermore, the correlation equations of the mathematical relationships among the maximum explosion overpressure Pred, the static activation pressure Pstat and the vent coefficient Kv under four vent layouts are established, respectively.  相似文献   

2.
The overpressure peaks and flame propagation characteristics of hydrocarbon fuel-air mixtures vented deflagration in a 20-L cylindrical vessel with a slight static activation overpressure (PST = 2.5 kPa) and five vent opening ratio were studied by a series of experiments. The experiments focused on the effect of vent opening ratio on the overpressure peaks and flame propagation characteristics of hydrocarbon fuel-air mixture vented deflagration. The internal overpressure-time profiles and high-speed photographs of flame propagation processes were obtained. The results showed that three overpressure peaks were distinguished in the internal overpressure-time profiles, caused by the burst vent cover (pburst), the acceleration of burnt gas (pfv), and the fierce external deflagration of vented unburned fuel (pext), respectively. The changing of the vent opening ratio had almost no effect on the value of pburst and (dpburst/dt). With increasing vent opening ratio, the values of pfv, pext, (dpfv/dt) and (dpext/dt) showed a decreasing trend while the values of pburst and (dpburst/dt) were nearly constant. The flame presented a hemispherical shape before the vent cover ruptured then developed as a mushroom shape after accelerated to external field. There were three flame speed peaks during flame propagation process, resulted from venting flow acceleration, external deflagration, and axial heat flux formed by internal combustion. With the increase of vent opening ratio, all of the maximum flame speed, external average flame speed, maximum flame distance and external flame duration showed a downward trend, excepting for the internal average flame speed almost remained constant.  相似文献   

3.
A study of vented explosions in a length over diameter (L/D) of 2 in cylindrical vessel connecting with a vent duct (L/D = 7) is reported. The influence of vent burst pressure and ignition locations on the maximum overpressure and flame speeds at constant vent coefficient, K of 16.4 were investigated to elucidate how these parameters affect the severity of a vented explosion. Propane and methane/air mixtures were studied with equivalence ratio, Φ ranges from 0.8 to 1.6. It is demonstrated that end ignition exhibited higher maximum overpressures and flame speeds in comparison to central ignition, contrary to what is reported in literature. There was a large acceleration of the flame toward the duct due to the development of cellular flames and end ignition demonstrated to have higher flame speeds prior to entry into the vent due to the larger flame distance. The higher vent flow velocities and subsequent flame speeds were responsible for the higher overpressures obtained. Rich mixtures for propane/air mixtures at Φ = 1.35 had the greatest flame acceleration and the highest overpressures. In addition, the results showed that Bartknecht's gas explosion venting correlation is grossly overestimated the overpressure for K = 16.4 and thus, misleading the impact of the vent burst pressure.  相似文献   

4.
Dust explosion venting experiments were performed using a 20-L spherical chamber at elevated static activation overpressures larger than 1 bar. Lycopodium dust samples with mean diameter of 70 μm and electric igniters with 0.5 KJ ignition energy were used in the experiments. Explosion overpressures in the chamber and flame appearances near the vent were recorded simultaneously. The results indicated that the flame appeared as the under-expanded free jet with shock diamonds, when the overpressure in the chamber was larger than the critical pressure during the venting process. The flame appeared as the normal constant-pressure combustion when the pressure venting process finished. Three types of venting processes were concluded in the experiments: no secondary flame and no secondary explosion, secondary flame, secondary explosion. The occurrence of the secondary explosions near the vent was related to the vent diameter and the static activation overpressure. Larger diameters and lower static activation overpressures were beneficial to the occurrence of the secondary explosions. In current experiments, the secondary explosions only occurred at the following combinations of the vent diameter and the static activation overpressure: 40 mm and 1.2 bar, 60 mm and 1.2 bar, 60 mm and 1.8 bar.  相似文献   

5.
A series of medium-scale experiments on vented hydrogen deflagration was carried out at the KIT test side in a chamber of 1 × 1 × 1 m3 size with different vent areas. The experimental program was divided in three series: (1) uniform hydrogen–air mixtures; (2) stratified hydrogen–air mixtures within the enclosure; (3) a layer deflagration of uniform mixture. Different uniform hydrogen–air mixtures from 7 to 18% hydrogen were tested with variable vent areas 0.01–1.0 m2. One test was done for rich mixture with 50% H2. To vary a gradient of concentration, all the experiments with a stratified hydrogen–air mixtures had about 4%H2 at the bottom and 10 to 25% H2 at the top of the enclosure. Measurement system consisted of a set of pressure sensors and thermocouples inside and outside the enclosure. Four cameras combined with a schlieren system (BOS) for visual observation of combustion process through transparent sidewalls were used. Four experiments were selected as benchmark experiments to compare them with four times larger scale FM Global tests (Bauwens et al., 2011) and to provide experimental data for further CFD modelling. The nature of external explosion leading to the multiple pressure peak structure was investigated in details. Current work addresses knowledge gaps regarding indoor hydrogen accumulations and vented deflagrations. The experiments carried out within this work attend to contribute the data for improved criteria for hydrogen–air mixture and enclosure parameters to avoid unacceptable explosion overpressure. Based on theoretical analysis and current experimental data a further vent sizing technology for hydrogen deflagrations in confined spaces should be developed, taking into account the peculiarities of hydrogen–air mixture deflagrations in presence of obstacles, concentration gradients of hydrogen–air mixtures, dimensions of a layer of flammable cloud, vent inertia, etc.  相似文献   

6.
Experiments were conducted in a 1 m3 vessel with a top vent to investigate the effect of methane concentration and ignition position on pressure buildup and flame behavior. Three pressure peaks (p1, p2, and Pext) and two types of pressure oscillations (Helmholtz and acoustic oscillations) were observed. The rupture of vent cover results in p1 that is insensitive to methane concentration and ignition position. Owing to the interaction between acoustic wave and the flame, p2 forms in the central and top ignition explosions when the methane–air mixture is near–stoichiometric. When the methane–air mixture is centrally ignited, p2 first increases and then decreases with an increase in the methane concentration. The external explosion-induced Pext is observed only in the bottom ignition explosions with an amplitude of several kilopascals. Under the current experimental conditions, flame–acoustic interaction leads to the most serious explosions in central ignition tests. Methane concentration and ignition position have little effect on the frequency of Helmholtz and acoustic oscillations; however, the Helmholtz oscillation lasts longer and first decreases and then increases as the methane concentration increases for top ignition cases. The ignition position significantly affects the Taylor instability of the flame front resulting from the Helmholtz oscillation.  相似文献   

7.
The hazardous effect of dynamic pressure and strong gas flows induced by a methane–air mixture explosion in underground coal mines is studied. The dynamic pressure effect of a methane–air explosion was analyzed by numerical simulation, in a duct and tunnel. Compared to the overpressure generated by an explosion that can act on a body, the dynamic pressure caused by the high-speed flow of the gaseous combustion products can cause serious damage as well. At the structural opening of a coal mine, the destruction caused by the dynamic pressure induced by a methane–air explosion is more serious than the overpressure. For a tube or tunnel partially filled by a methane–air mixture, the dynamic pressure is lower than the overpressure in the region occupied by the flammable mixture. Beyond the premixed region, the dynamic pressure is of the same order of magnitude as the overpressure.  相似文献   

8.
This study investigated methane-air explosion in tunnel-shape space and developed an overpressure-time history model based on numerical results. The findings revealed that for the progressively vented gas explosion with movable steel obstacles in a 20 m long tunnel, the inner peak overpressure increased as the activation pressure of the tunnel top cover got higher but remained below 6 bar. However, as the activation pressure increased to 8 bar or higher, the peak inner overpressure remained unchanged. As the segment cover panel became wider, the peak pressure was almost unchanged, but the pressure duration and impulse declined significantly. The peak pressure and impulse increased as the tunnel length vary from 10 to 30 m. With fixed tunnel length, higher blast pressure but lower impulse was observed as the inner obstacles were closer or the activation pressure of obstacles was higher. It is also found that a local enlarged space in the tunnel enhanced the peak pressure significantly. An overpressure time history model for the tunnel with fixed top cover and enlarged end zone was established. The model considered activation pressure of vent cover, area and length of vent opening, methane concentration, number and blockage ratio of fixed obstacles was developed to calculate the overpressure and corresponding time at characteristic points of the pressure-history curve. The cubic Hermite interpolation algorithm and a specially tuned formula consisting of the power and exponential function were used to interpolate pressure values between characteristic points. The proposed model can predict both the peak pressure and the overpressure time history with acceptable accuracy.  相似文献   

9.
In order to deeply understand the inhibitory effect of ultrafine water mist containing methane-oxidizing bacteria on methane explosion, a small-sized semi-closed visual experimental platform was built. Five different application mist amounts (0.7 mL, 2.1 mL, 3.5 mL, 4.9 mL, 6.3 mL) of ultrafine water mist containing methane-oxidizing bacteria on 9.5% methane explosion were studied experimentally. Ultrafine water mist was generated by the ultrasonic atomization generator, and mist size was measured by a winner319 laser particle size analyzer. During the methane explosion, a high-frequency pressure sensor collected pressure change data, and a high-speed camera recorded the flame development process. The results indicated that the maximum explosion overpressure (ΔPmax) decreased with time, and the arrival time of the maximum explosion overpressure (ΔPmax) delayed. The appearance time of the “tulip” shaped flame delayed, and the flame propagation speed decreased. The ultrafine water mist and deposition can effectively inhibit the methane explosion. The explosion suppression effect of the second step spraying water mist was better. The improvement of the explosion suppression effect of the ultrafine water mist containing methane-oxidizing bacteria was attributed to the degradation effect of the methane-oxidizing bacteria. Under long-term degradation, methane-oxidizing bacteria in water mist play a role in inhibiting methane explosion.  相似文献   

10.
The effect of the vent burst pressure on explosion venting of a rich methane-air mixture was experimentally investigated in a small cylindrical vessel. The experimental results show that Helmholtz oscillation of the internal flame bubble of the methane-air mixture can occur in a vessel with a vent area much smaller than that reported by previous researchers, and the period of Helmholtz oscillation decreases slightly when the vent burst pressure increases. The maximum overpressure in the vessel increases approximately linearly with the increase in the vent burst pressure; however, the pressure peaks induced by Helmholtz oscillation always remain approximately several kilopascals. The external flame reaches its maximum length in a few milliseconds after vent failure and then oscillates in accordance with the pressure oscillation in the vessel. The maximum length of the external flame increases, but its duration time decreases with the increase in the vent burst pressure.  相似文献   

11.
The methane–air detonation experiments are performed to characterize high pressure explosion processes that may occur in sealed areas of underground coal mines. The detonation tube used for these studies is 73 m long, 105 cm internal diameter, and closed at one end. The test gas is 97.5% methane with about 1.5% ethane, and the methane–air test mixtures varied between 4% and 19% methane by volume. Detonations were successfully initiated for mixtures containing between 5.3% and 15.5% methane. The detonations propagated with an average velocity between 1512 and 1863 m/s. Average overpressures recorded behind the first shock pressure peak varied between 1.2 and 1.7 MPa. The measured detonation velocities and pressures are close to their corresponding theoretical Chapman-Jouguet (CJ) detonation velocity (DCJ) and detonation pressure (PCJ). Outside of these detonability limits, failed detonations produced decaying detached shocks and flames propagating with velocities of approximately 1/2 DCJ. Cell patterns on smokefoils during detonations were very irregular and showed secondary cell structures inside primary cells. The measured width of primary cells varied between 20 cm near the stoichiometry and 105 cm (tube diameter) near the limits. The largest detonation cell (105 cm wide and 170 cm long) was recorded for the mixture containing 15.3% methane.  相似文献   

12.
The wood gasification process poses serious concerns about the risk of explosion. The design of prevention and mitigation measures requires the knowledge of safety parameters, such as the maximum explosion pressure, the maximum rate of pressure rise and the gas deflagration index, KG, at standard ambient temperature (25 °C) and pressure (1 bar) conditions. However, the analysis at specific process conditions is strongly recommended, as the explosion behavior of gas mixtures may be completely different.In the work presented in this paper, the explosion behavior of mixtures with composition representative of wood chip-derived syngas (CO/H2/CH4/CO2/N2 mixtures with and without H2O) was experimentally studied in a closed combustion chamber. Experiments were run at two temperatures, 300 °C and 10 °C, and at atmospheric pressure. Test conditions were requested by the safety engineering designer of an existing industrial-scale wood gasification plant. In order to identify the specific fuel–air ratios to be analyzed, thus reducing the number of experimental tests, a preliminary thermo-kinetic study was performed.Results have shown that the mixtures investigated can be classified as low-reactivity mixtures, the higher value of KG found (∼36 bar m/s) being much lower than the KG value of methane (55 bar m/s @ 25 °C).  相似文献   

13.
The explosion of the methane/air mixture and the methane/coal dust/air mixture under 40 J center spark ignition condition was experimentally studied in a large-scale system of 10 m3 vessel. Five pressure sensors were arranged in space with different distances from the ignition point. A high-speed camera system was used to record the growth of the flame. The maximum overpressure of the methane/air mixture appeared at 0.75 m away from the ignition point; the thickness of the flame was about 10 mm and the propagation speed of the flame fluctuated around 2.5 m/s with the methane concentration of 9.5%. The maximum overpressure of the methane/coal dust/air mixture appeared at 0.5 m. The flame had a structure of three concentric zones from outside were the red zone, the yellow illuminating zone and the bright white illuminating zone respectively; the thickness and the propagation speed of the flame increased gradually, the thickness of red zone and yellow illuminating zone reached 3.5 cm and 1 cm, the speed reached 9.2 m/s at 28 ms.  相似文献   

14.
This paper investigated the effects of blast wave oscillation on the overpressure of premixed methane/air explosions by numerical simulations and experiments. The AutoReaGas 3D code and a duct were used in the study. The oscillation induced by the repeat reflection of a blast wave in a closed-end duct was observed by high-speed camera. There was an oscillation zone in the blast wave which exhibited some saw-toothed characteristics. This explained why the overpressure in closed-end ducts was higher than that in open-end ducts. In addition, some of the peak overpressure was even higher than the C–J pressure of 1.76 MPa. The peak overpressures at the ducts' ends were higher than at other measurement points for 5 m, 10 m, and 15 m long ducts. This was mainly due to the reflection of the blast wave. The oscillating period increased with increasing duct length, and could be calculated by t = 0.0003 + 0.00198 L. However, the duct's diameter had no significant influence on the oscillation's period. The amplitude increased with increases in the duct length, except for the case of a 20 m long duct, and increased with decreases in the ducts' diameter. In addition, the peak overpressures in ducts of the same length/diameter ratio were similar. The peak overpressure increased with the increase of the length/diameter ratio, and the maximum value of the peak overpressure in the ducts had the same trend. However, the overpressure did not increase when the length/diameter ratio reached 250.  相似文献   

15.
The effect of internal shape of obstacles on the deflagration of premixed methane–air (concentration of 10%) was experimentally investigated in a semi-confined steel pipeline (with a square cross section size of 80 mm × 80 mm and 4 m long). The obstacles used in this study were circular, square, triangular and gear-shaped (4-teeth, 6-teeth and 8-teeth) orifice plates with a blockage ratio of 75%, and the perimeter of the orifice was regarded as a criterion for determining the sharpness of the orifice plate. The overpressure history, flame intensity histories, flame front propagation speed, maximum flame intensity and peak explosion overpressure were analyzed. The explosion in the pipeline can be divided into two stages: initial explosion and secondary explosion. The secondary explosion is caused by recoiled flame. The perimeter is positively related to the intensity of the recoiled flame and the ability of orifice plate to suppress the explosion propagation. In addition, the increase in the perimeter will cause the acceleration of the flame passing through the orifice plate, while after the perimeter of the orifice reaches a certain value, the effect of the increase in perimeter on explosion excitation becomes no obvious. The overpressure (static pressure) downstream of the orifice plate is the result of the combined effect of explosion intensity and turbulence. The increase in perimeter leads to the increase in turbulence downstream of the orifice plate which in turn causes more explosion pressure to be converted into dynamic pressure.  相似文献   

16.
A set of 34 experiments on vented hydrocarbon–air and hydrogen–air deflagrations in unobstructed enclosures of volume up to 4000 m3 was processed with use of the advanced lumped parameter approach. Reasonable compliance between calculated pressure–time curves and experimental pressure traces is demonstrated for different explosion conditions, including high, moderate, low and extremely low reduced overpressures in enclosures of different shape (Lmax:Lmin up to 6:1) with different type and position of the ignition source relative to the vent, for near-stoichiometric air mixtures of acetone, methane, natural gas and propane, as well as for lean and stoichiometric hydrogen–air mixtures. New data were obtained on flame stretch for vented deflagrations.The fundamental Le Chatelier–Brown principle analog for vented deflagrations has been considered in detail and its universality has been confirmed. The importance of this principle for explosion safety engineering has been emphasized and proved by examples.A correlation for prediction of the deflagration–outflow interaction number, χ/μ, on enclosure scale, Bradley number and vent release pressure is suggested for unobstructed enclosures and a wide range of explosion conditions. Fractal theory has been employed to verify the universality of the dependence revealed of the deflagration–outflow interaction number on enclosure scale.In spite of differences between the thermodynamic and kinetic parameters of hydrocarbon–air and hydrogen–air systems, they both obey the same general regularities for vented deflagrations, including the Le Chatelier–Brown principle analog and the correlation for deflagration–outflow interaction number.  相似文献   

17.
Methane/coal dust/air explosions under strong ignition conditions have been studied in a 199 mm inner diameter and 30.8 m long horizontal tube. A fuel gas/air manifold assembly was used to introduce methane and air into the experimental tube, and an array of 44 equally spaced dust dispersion units was used to disperse coal dust particles into the tube. The methane/coal dust/air mixture was ignited by a 7 m long epoxypropane mist cloud explosion. A deflagration-to-detonation transition (DDT) was observed, and a self-sustained detonation wave characterized by the existence of a transverse wave was propagated in the methane/coal dust/air mixtures.The suppressing effects on methane/coal dust/air mixture explosions of three solid particle suppressing agents have been studied. Coal dust and the suppressing agent were injected into the experimental tube by the dust dispersion units. The length of the suppression was 14 m. The suppression agents examined in this study comprised ABC powder, SiO2 powder, and rock dust powder (CaCO3). Methane/coal dust/air explosions can be efficiently suppressed by the suppression agents characterized by the rapid decrease in overpressure and propagating velocity of the explosion waves.  相似文献   

18.
An experimental study has been conducted to investigate the effects of hydrogen addition on the fundamental propagation characteristics of methane/air premixed flames at different equivalence ratios in a venting duct. The hydrogen fraction in the methane–hydrogen mixture was varied from 0 to 1 at equivalence ratios of 0.8, 1.0 and 1.2. The results indicate that the tendency towards flame instability increased with the fraction of hydrogen, and the premixed hydrogen/methane flame underwent a complex shape change with the increasing hydrogen fraction. The tulip flame only formed when the fraction of hydrogen ranged from 0 to 50% at an equivalence ratio of 0.8. It was also found that the flame front speed and the overpressure increased significantly with the hydrogen fraction. For all equivalence ratios, the stoichiometric flame (Φ = 1.0) has the shortest time of flame propagation and the maximum overpressure.  相似文献   

19.
A 20 L spherical explosive device with a venting diameter of 110 mm was used to study the vented pressure and flame propagation characteristics of corn dust explosion with an activation pressure of 0.78–2.1 bar and a dust concentration of 400∼900 g/m3. And the formation and prevention of secondary vented flame are analyzed and discussed. The results show that the maximum reduced explosion overpressure increases with the activation pressure, and the vented flame length and propagation speed increase first and then decrease with time. The pressure and flame venting process models are established, and the region where the secondary flame occurs is predicted. Whether there is pressure accompanying or not in the venting process, the flame venting process is divided into two stages: overpressure venting and normal pressure venting. In the overpressure venting stage, the flame shape gradually changes from under-expanded jet flame to turbulent jet flame. In the normal pressure venting stage, the flame form is a turbulent combustion flame, and a secondary flame occurs under certain conditions. The bleed flames within the test range are divided into three regions and four types according to the shape of the flame and whether there is a secondary flame. The analysis found that when the activation pressure is 0.78 bar and the dust concentration is less than 500 g/m3, there will be no secondary flame. Therefore, to prevent secondary flames, it is necessary to reduce the activation pressure and dust concentration. When the dust concentration is greater than 600 g/m3, the critical dust concentration of the secondary flame gradually increases with the increase of the activation pressure. Therefore, when the dust concentration is not controllable, a higher activation pressure can be selected based on comprehensive consideration of the activation pressure and destruction pressure of the device to prevent the occurrence of the secondary flame.  相似文献   

20.
In this study, in order to research the synergistic inhibition effect of nitrogen and ultrafine water mist on gas explosion in a vented duct, a semi-confined transparent chamber was designed with the size of 120 × 120 × 840 mm, and the experiments were carried out with stoichiometric methane/air premixed mixture (fraction of methane: 9.5%), adding different fractions of nitrogen and ultrafine water mist. The experimental results showed the following: The combination of nitrogen and ultrafine water mist had a synergistic inhibiting effect on methane/air explosion, which was preferable to the single use of any kind. With the increase of spraying time of water mist and fraction of nitrogen, the initial shape of the explosion flame became snakelike, and at the same time the peak flame propagation speed and peak overpressure decreased significantly. When the nitrogen fraction was increased to 10% and the mist spraying time was increased to 2min, synergistic inhibiting effect on overpressure was high efficient. However, with the increase of spraying time of water mist and fraction of nitrogen going on, the amount of increase of explosion inhibition efficiency was gradually reduced.  相似文献   