首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 510 毫秒
1.
对絮凝预处理后的垃圾渗滤液进行Fenton氧化处理。通过微分法对Fenton氧化的反应级数进行求解,确定其反应级数为2,并初步建立了Fenton氧化的动力学模型,即1/c=1/c0+kt,由此建立起来的降解的动力学模型与实验数据相吻合;在4个实验基准条件下———初始COD浓度为960 mg/L、pH值4、H2O2投加量0.4 mol/L、nH2O2/nFe2+3∶1,探讨了其中某一变量对反应速率的影响。实验水样为絮凝反应出水,进水COD浓度为912~960 mg/L,出水COD浓度为80~112 mg/L,COD去除率在87%~92%之间,表明Fenton试剂能够有效地处理垃圾渗滤液。  相似文献   

2.
混凝与Fenton联用处理垃圾渗滤液的效能及成本   总被引:3,自引:2,他引:1  
为对混凝/Fenton工艺与Fenton/混凝工艺处理垃圾渗滤液的效果和成本进行比较,分别对年轻渗滤液和老龄渗滤液原液按照混凝/Fenton工艺与Fenton/混凝工艺2种技术路线进行处理。实验结果表明,Fenton试剂对年轻垃圾渗滤液和老龄垃圾渗滤液COD去除率最高的反应条件为pH=3.5、H2O2和Fe2+的摩尔比为6、H2O2和渗滤液原液的COD质量比为3、反应时间4 h;在PAC与渗滤液原液的COD质量比为0.6时,PAC混凝对渗滤液原液的COD去除率最高。在对渗滤液COD去除率最高的Fenton反应和PAC混凝反应条件下,混凝/Fenton工艺对年轻渗滤液和老龄渗滤液的COD去除率分别为90.56%和86.56%;Fenton/混凝工艺对年轻渗滤液和老龄渗滤液的COD去除率分别为89.99%和85.99%,2种技术路线对渗滤液COD的去除率相差不大,但先PAC混凝后Fenton氧化工艺比先Fenton后混凝工艺每t节省62.6元,是更优化的渗滤液处理工艺。  相似文献   

3.
采用活性炭载体负载Cu、Fe为催化剂,在微波诱导作用下,对垃圾渗滤液污染物进行降解。实验结果表明,活性炭负载金属前经适当浓度硝酸浸泡处理后,催化剂对COD去除率提高可超过15%,过高硝酸盐浓度对COD去除有不利影响;催化剂对COD去除率随Cu、Fe金属负载量增加呈先增加后降低的趋势,催化剂对Cu、Fe的最佳负载量分别为质量百分比2.11%和1.12%。对于AC-Cu体系,在初始pH=3,H2O2投加量为4.98×103mg/L,催化剂用量为5.0×103mg/L,420 W功率下微波辐射10 min时,垃圾渗滤液COD去除率可达到84.13%;对于AC-Fe体系,当H2O2投加量为0.33×103mg/L,催化剂AC-Fe用量为2.0×104mg/L,420 W功率下微波作用10 min时,垃圾渗滤液COD去除率为60.16%。分析2种催化剂对COD去除差异的原因,可能是催化剂AC-Cu表面单分子分布的阈值比AC-Fe高。降解液的pH值对AC-Cu体系、AC-Fe体系COD去除影响存在拐点,最高COD去除率点对应的降解液pH值为3。微波辐射功率较低时,体系COD去除率随辐射功率增加而增加;辐射功率较高时,高温下垃圾渗滤液中有机硫化物分解成小分子硫化物,对催化剂活性存在一定抑制作用。  相似文献   

4.
采用Fenton氧化法对青霉素和土霉素混合废水二级处理出水进行深度处理,通过正交和单因素实验研究了废水初始反应pH值、H2O2投加量、Fe2+/H2O2摩尔比及反应时间等因素对废水处理效果的影响。实验结果表明,Fenton氧化法处理的最佳反应条件为:初始pH值4、H2O2(30%)投加量50 mL/L、Fe2+/H2O2摩尔比1/20和反应时间60 min,处理后出水COD小于120 mg/L,COD去除率在75%以上,急性毒性(HgCl2毒性当量)小于0.07 mg/L,满足《发酵类制药工业水污染物排放标准》(GB21903-2008)表2标准要求。  相似文献   

5.
垃圾渗滤液经一般生化处理后色度很大。对混凝和芬顿法结合深度处理垃圾渗滤液对色度去除进行了研究。混凝段通过中心复合设计(简称CCD)和响应面方法(简称RSM)分析了混凝的色度去除率的响应特征,建立了实际因素的最终方程模型:Y(色度去除率,%)=-553.40+73.74A+229.06B+0.38AB-34.16A2-22.67B2,(Y、A、B分别代表色度去除率、投加量和pH)并对絮凝条件进行优化,得到混凝反应的最佳优化条件:投加量1.11 g/L,pH 5.06,及在此条件下的去除率67.2%。在芬顿段,将芬顿反应对水中亲水性有机物相对含量(UV254)与对色度的去除特征相结合进行了研究,证明色度的去除跟该类有机物的去除有关,色度去除率最优值条件选择为H2O2/COD=1.0,Fe2+/H2O2=0.35∶1,而初始pH=2.5时对色度的去除达到99%以上。整个工艺出水可达到达标排放标(GB16889-2008)。  相似文献   

6.
超声-Fenton联用技术深度处理皮革综合废水生化出水   总被引:2,自引:1,他引:1  
针对皮革综合废水生化处理出水中存在COD和色度偏高等问题,提出采用超声-Fenton联用技术对生化后的皮革综合废水进行深度处理。通过单因素实验考察了超声功率、H2O2投加量、Fe2+投加量(即H2O2/Fe2+比)、溶液pH和反应时间对水样中COD和色度去除率的影响;正交实验结果表明,当溶液初始pH值为4.0时,各因素影响显著性的先后顺序为H2O2>超声功率>反应时间>Fe2+;其优化的实验条件为:H2O2为24.0 mL/L、超声功率为85 W、反应时间为45min、Fe2+为2.2 g/L,经超声-Fenton联用技术深度处理后COD的去除率可达85.4%。在最佳实验条件下,对超声-Fenton联用技术深度处理皮革综合废水生化出水的动力学研究发现,水样中的COD降解反应符合表观一级反应动力学,速率常数增强因子可达8.64,表明存在显著的协同效应。  相似文献   

7.
采用铁炭微电解-Fenton联合工艺深度处理制药废水生化出水,探讨了初始pH、曝气量、反应时间等因素对微电解出水Fe2+和Fe3+变化规律、COD降解速率以及后续Fenton氧化效果的影响,为优化微电解-Fenton氧化联合工艺提出了微电解间歇加酸的理论。间歇加酸可提高微电解系统中COD降解速率和Fe2+含量,使后续Fenton氧化无需投加FeSO4·7H2O即可达到较好的COD去除效果。结果表明,当初始pH=2.5,曝气量为0.6 m3/h,间歇加酸30 min/次,微电解反应2 h,出水投加1 mL/L的H2O2进行Fenton氧化2 h,COD总去除率可达81.33%;间歇加酸30 min/次可将微电解反应2 h出水Fe2+浓度从50 mg/L提高至151 mg/L,COD降解速率从10.6 mg COD/(L·h)提高至22.2 mg COD/(L·h)。  相似文献   

8.
以粉煤灰为载体,制备铁/粉煤灰负载型催化剂,并利用该催化剂催化H2O2氧化降解活性黄染料废水,探讨了H2O2投加量、催化剂投加量、染料初始浓度和初始pH值等因素对染料废水COD去除率和脱色率的影响。结果表明,当染料废水COD初始浓度为200 mg/L,初始pH值为1.7,投加0.5 g/100 mL催化剂及加入1.0 mL浓度为1.13 mol/L的H2O2溶液时,处理效果最好,此时染料废水的COD去除率和脱色率分别达到63%和99%,并且废水的可生化性得到很大的提高。利用该负载催化剂能够有效地减少活性黄染料废水中Fe3+的残留量。  相似文献   

9.
Fenton法处理垃圾渗滤液MBR-NF浓缩液   总被引:1,自引:0,他引:1  
采用Fenton法处理MBR-NF浓缩液,考察了FeSO4·7H2O投加量、n(H2O2)/n(Fe2+)投加比、初始pH对渗滤液MBR-NF浓缩液处理效果的影响,并在最佳实验条件下,探讨浓缩液富里酸(FA)、亲水性有机物(HyI)组分在Fenton氧化前后组成的变化。研究结果表明,在FeSO4·7H2O投加量为0.055 mol/L、n(H2O2)/n(Fe2+)投加比为4、初始pH为7.58时,对COD、腐植酸(UV254)、色度(CN)的去除率分别为79.6%、93.7%和97.8%。Fenton氧化后,浓缩液中有机物组分含量发生了较大变化,腐植酸含量下降,HyI成为渗滤液溶解性有机物主要成分。紫外-可见光谱表明,Fenton法对FA去除效果较好,而对HyI氧化效果较差;傅立叶红外光谱显示,经Fenton氧化后,FA的结构发生了明显变化,而HyI则变化不明显。  相似文献   

10.
Fenton氧化法深度处理甲醛废水   总被引:1,自引:0,他引:1  
采用Fenton氧化法深度处理经生化降解后的甲醛废水,结果表明,Fenton氧化法深度处理甲醛废水是可行的,在合适的反应条件下,降解初始COD为150 mg/L左右的甲醛废水,COD去除率达30%以上;Fe2+与H2O2的投加比例、投加量及投加方式、反应温度、pH、反应时间对处理效果都有不同程度的影响。  相似文献   

11.
A novel nanosize metallic calcium/iron dispersed reagent was synthesized and tested as coagulant/catalyst in a hybrid zero valent iron (ZVI)/H2O2 oxidation process to treat leachate. Two different types of leachates, one from municipal solid waste (MSW) tipping hall (MSWIL) and second from an MSW landfill site (MSWLL), were collected and characterized. The morphology, elemental composition, and mineral phases of the nano-Ca/CaO and nano-Fe/Ca/CaO were characterized by scanning electron microscopy–electron dispersive spectroscopy (SEM-EDS) and x-ray powder diffraction (XRD) analysis. The coagulation process with 2.5 g L?1 nano-Ca/CaO attained 64.0, 56.0, and 20.7% removal of color, chemical oxygen demand (COD), and total suspended solids (TSS) in MSWLL. With only 1.0 g L?1 of nano-Fe/Ca/CaO, relatively high color, COD and TSS removal was achieved in MSWLL at 67.5, 60.2, and 37.7%, respectively. The heavy metal removal efficiency reached 91–99% after treatment with nano-Fe/Ca/CaO in both leachate samples. The coupling process, using 1.0 g L?1 of nano-Fe/Ca/CaO and 20 mM H2O2 doses, achieved enhancement removal of color, COD, and TSS, up to 95%, 96%, and 66%, respectively, without initial pH control. After this treatment, the color, COD, TSS, and heavy metals were significantly decreased, fitting the Korean discharge regulation limit. A hybrid coupled zero valent iron (ZVI)/H2O2 oxidation process with novel nanosized metallic calcium/iron dispersed reagent proved to be a suitable treatment for dealing with leachate samples.

Implications: Conventional treatments (biological or physicochemical) are not sufficient anymore to reach the level of purification needed to fully reduce the negative impact of landfill leachates on the environment. This implies that new treatment alternatives species must be proposed. A coupled zero valent iron (ZVI)/H2O2 oxidation process proved to be a suitable treatment for dealing with leachate samples. Coagulation with nFe/Ca/CaO allows 91–99% of heavy metals removal. The coupled coagulation–oxidation process by nFe/Ca/CaO reveals excellent ability to treat leachate. After coupled treatment the color, COD, and TSS were also much lower than the discharge regulation limit.  相似文献   

12.
In order to remove high concentrations of hydrogen sulfide (H2S) gas from anaerobic wastewater treatments in livestock farming, a novel process was evaluated for H2S gas abatement involving the combination of chemical absorption and biological oxidation processes. In this study, the extensive experiments evaluating the removal efficiency, capacity, and removal characteristics of H2S gas by the chemical absorption reactor were conducted in a continuous operation. In addition, the effects of initial Fe2 + concentrations, pH, and glucose concentrations on Fe2 + oxidation by Thiobacillus ferrooxidans CP9 were also examined. The results showed that the chemical process exhibited high removal efficiencies with H2S concentrations up to 300 ppm, and nearly no acclimation time was required. The limitation of mass‐transfer was verified as the rate‐determining step in the chemical reaction through model validation. The Fe2 + production rate was clearly affected by the inlet gas concentration as well as flow rate and a prediction equation of ferrous production was established. The optimal operating conditions for the biological oxidation process were below pH 2.3 and 35°C in which more than 90% Fe3 + formation ratio was achieved. Interestingly, the optimal glucose concentration in the medium was 0.1%, which favored Fe2 + oxidation and the growth of T. ferrooxidans CP9.  相似文献   

13.

In this study, the photochemical degradation of livestock wastewater was carried out by the Fenton and Photo-Fenton processes. The effects of pH, reaction time, the molar ratio of Fe2 +/H2O2, and the Fe2 + dose were studied. The optimal conditions for the Fenton and Photo-Fenton processes were found to be at a pH of 4 and 5, an Fe2 + dose of 0.066 M and 0.01 M, a concentration of hydrogen peroxide of 0.2 M and 0.1 M, and a molar ratio (Fe2 +/H2O2) of 0.33 and 0.1, respectively. The optimal reaction times in the Fenton and Photo-Fenton processes were 60 min and 80 min, respectively. Under the optimal conditions of the Fenton and Photo-Fenton processes, the chemical oxygen demand (COD), color, and fecal coliform removal efficiencies were approximately 70–79, 70–85 and 96.0–99.4%, respectively.  相似文献   

14.
Degradation of bisphenol A (BPA) in aqueous solution was studied with high-efficiency sulfate radical (SO4 ), which was generated by the activation of persulfate (S2O8 2?) with ferrous ion (Fe2+). S2O8 2? was activated by Fe2+ to produce SO4 , and iron powder (Fe0) was used as a slow-releasing source of dissolved Fe2+. The major oxidation products of BPA were determined by liquid chromatography-mass spectrometer. The mineralization efficiency of BPA was monitored by total organic carbon (TOC) analyzer. BPA removal efficiency was improved by the increase of initial S2O8 2? or Fe2+ concentrations and then decreased with excess Fe2+ concentration. The adding mode of Fe2+ had significant impact on BPA degradation and mineralization. BPA removal rates increased from 49 to 97 % with sequential addition of Fe2+, while complete degradation was observed with continuous diffusion of Fe2+, and the latter achieved higher TOC removal rate. When Fe0 was employed as a slow-releasing source of dissolved Fe2+, 100 % of BPA degradation efficiency was achieved, and the highest removal rate of TOC (85 %) was obtained within 2 h. In the Fe0–S2O8 2? system, Fe0 as the activator of S2O8 2? could offer sustainable oxidation for BPA, and higher TOC removal rate was achieved. It was proved that Fe0–S2O8 2? system has perspective for future works.  相似文献   

15.
微波-Fenton对沼液中抗生素和激素的高级氧化   总被引:2,自引:1,他引:1  
采用微波强化Fenton氧化处理系统,研究H2O2浓度、Fe2+浓度、初始pH、微波辐射时间和微波辐射功率对沼液中喹乙醇、土霉素、四环素及金霉素降解效果的影响.结果发现,采用微波强化Fenton氧化降解沼液中抗生素与激素的最优条件是:H2O2浓度为40 mg/L、Fe2+浓度为12 mg/L、初始pH为4、微波辐射时间为2 min、微波辐射功率为中火(445W),沼液中喹乙醇、土霉素、四环素、金霉素和COD的去除率分别达到67%、93%、91%、88%和46%.在水浴条件下,与单独微波辐射和单独Fenton相比,微波强化Fenton氧化有明显的优越性.  相似文献   

16.
高星  李平  吴锦华 《环境工程学报》2014,8(6):2376-2380
采用"混凝-电解氧化-完全混合式活性污泥法(CSTR)"组合工艺深度处理垃圾渗滤液生物处理出水。探索了工艺的组合及各种工艺操作条件对垃圾渗滤液深度处理效果的影响,并对其影响机理进行了初步探讨。结果表明,以PAC为混凝剂时,在pH和药剂(有效成分)投加量分别为6.0和600 mg/L条件下,渗滤液COD去除率达到50%,有效降低了难溶惰性COD含量,缩短了后续电化学处置时间。混凝工艺后,采用电化学工艺处理,在最优工艺条件下:pH为6.0、电流I为1.2 A(电流密度为18.18 mA/cm2)、Cl-投加量为1 000 mg/L、极板距离为2 cm,电解30 min渗滤液COD去除率达到36%,同时,难降解有毒物含量明显降低,渗滤液可生化性TbOD/COD由10%提升至最大值64%。最后采用CSTR处理渗滤液电解出水,系统出水COD、氨氮和色度分别为100~150 mg/L、7~13 mg/L和25倍,为反渗透(RO)工序提供了良好的水质条件。  相似文献   

17.
Chu L  Wang J  Dong J  Liu H  Sun X 《Chemosphere》2012,86(4):409-414
In this study the treatment of coking wastewater was investigated by an advanced Fenton oxidation process using iron powder and hydrogen peroxide. Particular attention was paid to the effect of initial pH, dosage of H2O2 and to improvement in biodegradation. The results showed that higher COD and total phenol removal rates were achieved with a decrease in initial pH and an increase in H2O2 dosage. At an initial pH of less than 6.5 and H2O2 concentration of 0.3 M, COD removal reached 44-50% and approximately 95% of total phenol removal was achieved at a reaction time of 1 h. The oxygen uptake rate of the effluent measured at a reaction time of 1 h increased by approximately 65% compared to that of the raw coking wastewater. This indicated that biodegradation of the coking wastewater was significantly improved. Several organic compounds, including bifuran, quinoline, resorcinol and benzofuranol were removed completely as determined by GC-MS analysis. The advanced Fenton oxidation process is an effective pretreatment method for the removal of organic pollutants from coking wastewater. This process increases biodegradation, and may be combined with a classical biological process to achieve effluent of high quality.  相似文献   

18.
Sludge management is a fundamental activity in accordance with wastewater treatment aims. Sludge stabilization is always considered as a significant step of wastewater sludge handling. There has been a progressive development observed in the approach to the novel solutions in this regard. In this research, based on own initially experimental results in lab-scale regarding Fered-Fenton processes in view of organic loading (volatile-suspended solids, VSS) removal efficiency, a combination of both methods towards proper improving of excess biological sludge stabilization was investigated. Firstly, VSS removal efficiency has been experimentally studied in lab-scale under different operational conditions taking into consideration pH [Fe2+]/[H2O2], detention time [H2O2], and current density parameters. Therefore, the correlations of the same parameters have been determined by utilizing Kohonen self-organizing feature maps (KSOFM). In addition, multi-layer perceptron (MLP) has been employed afterwards for a comprehensive evaluation of investigating parameters correlation and prediction aims. The findings indicated that the best proportion of iron to hydrogen peroxide and the optimum pH were 0.58 and 3.1, respectively. Furthermore, maximum retention time about 6 h with a hydrogen peroxide concentration of 1,568 mg/l and a current density of 650–750 mA results to the optimum VSS removal (efficiency equals to 81 %). The performance of KSOFM and MLP models is found to be magnificent, with correlation ranging (R) from 0.873 to 0.998 for the process simulation and prediction. Finally, it can be concluded that the Fered-Fenton reactor is a suitable efficient process to reduce considerably sludge organic load and mathematical modeling tools as artificial neural networks are impressive methods of process simulation and prediction accordingly.  相似文献   

19.
The Fenton-like degradation of nalidixic acid was studied in this work. The effects of Fe3+ concentration and initial H2O2 concentration were investigated. Increasing the initial H2O2 concentration enhances the degradation and mineralization efficiency for nalidixic acid, while Fe3+ shows an optimal concentration of 0.25 mM. A complete removal of nalidixic acid and a TOC removal of 28 % were achieved in 60 min under a reaction condition of [Fe3+]?=?0.25 mM, [H2O2]?=?10 mM, T?=?35 °C, and pH?=?3. LC–MS analysis technique was used to analyze the possible degradation intermediates. The degradation pathways of nalidixic acid were proposed according to the identified intermediates and the electron density distribution of nalidixic acid. The Fenton-like degradation reaction of nalidixic acid mainly begins with the electrophilic attack of hydroxyl radical towards the C3 position which results in the ring-opening reaction; meanwhile, hydroxyl radical attacking to the branched alkyl groups of nalidixic acid leads to the oxidation at the branched alkyl groups.  相似文献   

20.
电-Fenton法预处理干法腈纶生产废水   总被引:2,自引:0,他引:2  
以Ti金属网为阴极,Ti基RuO2涂层形稳电极为阳极,采用外加H2O2和Fe2+的方式,研究了电-Fenton氧化预处理干法腈纶生产废水的工艺,考察了H2O2投加量、Fe2+投加量、pH值和电流强度等因素对污染物降解过程的影响,分析了废水可生化性和污染物变化规律。结果表明,电-Fenton法可以有效降解废水中有机污染物,使废水COD迅速降低,在初始pH值为3.0,Fe2+投加量为5.0 mmol/L,H2O2投加量为60.0 mmol/L,电流强度0.2 A的条件下,反应120 min后COD去除率可以达到44.0%以上;反应过程中H2O2的投加方式对电-Fenton法的处理效果具有明显影响,H2O2分6次投加可以使COD去除率由一次性投加时的44.8%提高至54.1%;处理后废水的BOD5/COD由0.29升高至0.68;GC-MS结果表明,经电-Fenton法预处理后,废水中多数芳香族化合物和特征污染物能被有效降解。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号