首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In this paper we present the development and application of a model for indoor air quality. The model represents a departure from the standard box models typically used for indoor environments which has applicability in residences and office buildings. The model has been developed for a physical system consisting of sequential compartments which communicate only with adjacent compartments. Each compartment may contain various source and sink terms for a pollutant as well as leakage, and air transfer from adjacent compartments. The mathematical derivation affords rapid calculation of equilibrium concentrations in an essentially unlimited number of compartments. The model has been applied to air quality in the passenger cabin of three commercial aircraft. Simulations have been performed for environmental tobacco smoke (ETS) under two scenarios, CO2 and water vapor. Additionally, concentrations in one aircraft have been simulated under conditions different from the standard configuration. Results of the simulations suggest the potential for elevated concentrations of ETS in smoking sections of non-air-recirculating aircraft and throughout the aircraft when air is recirculated. Concentrations of CO2 and water vapor are consistent with expected results. We conclude that this model may be a useful tool in understanding indoor air quality in general and on aircraft in particular.  相似文献   

2.
Considering tobacco smoke as one of the most health-relevant indoor sources, the aim of this work was to further understand its negative impacts on human health. The specific objectives of this work were to evaluate the levels of particulate-bound PAHs in smoking and non-smoking homes and to assess the risks associated with inhalation exposure to these compounds. The developed work concerned the application of the toxicity equivalency factors approach (including the estimation of the lifetime lung cancer risks, WHO) and the methodology established by USEPA (considering three different age categories) to 18 PAHs detected in inhalable (PM10) and fine (PM2.5) particles at two homes. The total concentrations of 18 PAHs (ΣPAHs) was 17.1 and 16.6 ng m?3 in PM10 and PM2.5 at smoking home and 7.60 and 7.16 ng m?3 in PM10 and PM2.5 at non-smoking one. Compounds with five and six rings composed the majority of the particulate PAHs content (i.e., 73 and 78 % of ΣPAHs at the smoking and non-smoking home, respectively). Target carcinogenic risks exceeded USEPA health-based guideline at smoking home for 2 different age categories. Estimated values of lifetime lung cancer risks largely exceeded (68–200 times) the health-based guideline levels at both homes thus demonstrating that long-term exposure to PAHs at the respective levels would eventually cause risk of developing cancer. The high determined values of cancer risks in the absence of smoking were probably caused by contribution of PAHs from outdoor sources.  相似文献   

3.
Concentrations of 15 volatile organic compounds have been investigated in the air of two schoolrooms. The chemical analysis included enrichment on porous polymer beads, heat desorption and gas Chromatographic separation on a capillary column connected to either a flame ionization detector or a mass spectrometer. Samples were collected from the indoor air both in the presence and in the absence of the pupils (boys and girls, age 16–19) as well as from the ambient outdoor air. The qualitative composition of indoor and outdoor air was found to be about the same : aliphatic and aromatic hydrocarbons predominate, though indoors the number of compounds detected is larger and the concentrations are higher. Both the number and the concentration increase in the presence of humans. The mean concentrations of acetone and the sum of the concentrations of C2-alkylbenzenes were 7.7 and 8.2 μg m−3 respectively in an unoccupied room and increased to 19.8 and 12.1 μg m−3 respectively in an occupied room.  相似文献   

4.
The aim of this study was to measure the air concentrations of carbon dioxide (CO2) and formaldehyde (HCHO) in daycare centers to determine relevant influencing factors, including temperature, relative humidity (RH), type of facility, number of children, type of ventilation system, ventilation time, and air cleaning system. The authors measured HCHO, CO2, temperature, and RH in the center of classrooms in 289 daycare centers. Spearman’s correlation and Mann–Whitney analyses were used to examine the relationships and differences in HCHO and CO2 for varying temperatures, RH values, and categorical indoor environmental factors. There were no significant differences in the HCHO and CO2 air concentrations with varying numbers of children, ventilation times, or ventilation and air cleaning system types. However, both the HCHO and CO2 air concentrations were significantly different for varying RH values, which were divided into five categories (p < 0.001). Only the HCHO air concentrations were significantly different for varying temperatures, which were divided into five categories (p < 0.001). Significant correlations were found between HCHO air concentrations and the temperature (r = 0.35, p < 0.0001), RH (r = 0.51, p < 0.0001), and CO2 (r = 0.36, p < 0.0001). The study results support maintaining an appropriate temperature and RH range for reducing airborne HCHO in daycare centers. Further research is needed to elucidate the precise mechanisms responsible for the relationships observed in this study.

Implications: Data from 289 daycare centers in Seoul, South Korea, indicate that HCHO concentrations show a positive correlation with indoor temperature and relative humidity. This indicates that keeping temperatures low will help keep HCHO concentrations low, by both a direct and an indirect effect, since low temperatures also cause low relative humidity.  相似文献   


5.
A field study was carried out to investigate the internal and external carbon monoxide (CO) concentration levels of a public school building in Athens, Greece. Simultaneous measurements of indoor and outdoor CO concentrations were conducted using a non-dispersive infrared analyzer. Measurements of mean hourly CO concentrations inside and outside the sampling room were conducted on a 24-h basis for 13 consecutive days during May and June 1999 and for 14 consecutive days during December 1999. The aim of the study was to investigate the attenuation pattern of external pollution levels within the building. The diurnal concentration variations reported for different days during the week show that indoor CO concentrations are in general lower than the respective outdoor levels, and that the morning peaks of indoor concentrations show a delay of 1 h or less compared to the morning peaks of outdoor concentrations. The measured indoor to outdoor concentration ratios show a seasonal variation. An indoor air quality model for the prediction of indoor concentration levels developed by Hayes (J. Air Pollut. Control Assoc. 39 (11) (1989) 1453; J. Air Waste Manage. Assoc. 41 (2) (1991) 161) is coded as a computer program and evaluated using the experimental data. The model results are in good agreement with the indoor concentration measurements, although in some cases the model cannot respond adequately to sharp outdoor concentration changes. The ratio between measured and predicted daily maximum indoor concentration ranges between 0.88 and 1.23. The regression curve between predicted by the model and measured hourly indoor concentrations, for a continuous period of 96 h, has a slope of 0.64 and a coefficient of determination (R2) of 0.69.  相似文献   

6.
7.
Cohort studies designed to estimate human health effects of exposures to urban pollutants require accurate determination of ambient concentrations in order to minimize exposure misclassification errors. However, it is often difficult to collect concentration information at each study subject location. In the absence of complete subject-specific measurements, land-use regression (LUR) models have frequently been used for estimating individual levels of exposures to ambient air pollution. The LUR models, however, have several limitations mainly dealing with extensive monitoring data needs and challenges involved in their broader applicability to other locations. In contrast, air quality models can provide high-resolution source–concentration linkages for multiple pollutants, but require detailed emissions and meteorological information. In this study, first we predicted air quality concentrations of PM2.5, NOx, and benzene in New Haven, CT using hybrid modeling techniques based on CMAQ and AERMOD model results. Next, we used these values as pseudo-observations to develop and evaluate the different LUR models built using alternative numbers of (training) sites (ranging from 25 to 285 locations out of the total 318 receptors). We then evaluated the fitted LUR models using various approaches, including: 1) internal “Leave-One-Out-Cross-Validation” (LOOCV) procedure within the “training” sites selected; and 2) “Hold-Out” evaluation procedure, where we set aside 33–293 tests sites as independent datasets for external model evaluation. LUR models appeared to perform well in the training datasets. However, when these LUR models were tested against independent hold out (test) datasets, their performance diminished considerably. Our results confirm the challenges facing the LUR community in attempting to fit empirical response surfaces to spatially- and temporally-varying pollution levels using LUR techniques that are site dependent. These results also illustrate the potential benefits of enhancing basic LUR models by utilizing air quality modeling tools or concepts in order to improve their reliability or transferability.  相似文献   

8.
Splitting techniques are commonly used when large-scale models, which appear in different fields of science and engineering, are treated numerically. Four types of splitting procedures are defined and discussed. The problem of the choice of a splitting procedure is investigated. Several numerical tests, by which the influence of the splitting errors on the accuracy of the results is studied, are given. It is shown that the splitting errors decrease linearly when (1) the splitting procedure is of first order and (2) the splitting errors are dominant. Three examples for splitting procedures used in all large-scale air pollution models are presented. Numerical results obtained by a particular air pollution model, Unified Danish Eulerian Model (UNI-DEM), are given and analysed.  相似文献   

9.
Environmental Science and Pollution Research - This study was carried out to investigate how serum cotinine and hydroxycotinine concentrations compare and vary by age, gender, race/ethnicity,...  相似文献   

10.
杭州某高校室内空气质量状况调查分析   总被引:1,自引:0,他引:1  
为了解高校室内污染状况,调查选取杭州市某高校75间教室按照装修完成后时间长短分成5组,分别于2011年3、6月进行氡、氨、甲醛和苯系物(苯、甲苯和二甲苯),浓度的检测.结果显示,甲醛和苯系物浓度与装修完成后时间长短、通风情况、温度、湿度密切相关,装修完成后1.0年内的教室浓度显著高于其余组(P<0.05).除装修完成后5.0年以上组外,各组甲醛和苯系物含量6月都呈现极显著增高趋势(p<0.01).所有室内氡和氨浓度均未超标.总体来说,该校室内空气质量状况总体良好,但新建建筑物的室内空气污染存在一定的安全隐患.  相似文献   

11.
The air-quality modelling system was conducted to evaluate emissions inventory and simulate air concentration over Thailand. The coupling model of the Regional Atmospheric Modelling System (RAMS) and the models-3 Community Multi-scale Air Quality (CMAQ) was applied to simulate the concentration distributions of gaseous pollutants (i.e., NOx, SO2 and CO) over the Central and Eastern regions of Thailand. CMAQ was run for a summertime episode in a sub-grid scale. Simulated air concentrations were then compared with monitoring data. The evaluating results between modelling simulation and monitoring observation show a good agreement within a factor of 2.0 and relevant trend line, representing the acceptable level of emissions and concentration. This coupling model can be applied to support emission control strategies and clean air acts.  相似文献   

12.
The use of sorbents has been proposed to remove volatile organic compounds (VOCs) present in ambient air at concentrations in the parts-per-billion (ppb) range, which is typical of indoor air quality applications. Sorbent materials, such as granular activated carbon and molecular sieves, are used to remove VOCs from gas streams in industrial applications, where VOC concentrations are typically in the parts-per-million range. A method for evaluating the VOC removal performance of sorbent materials using toluene concentrations in the ppb range is described. Breakthrough times for toluene at concentrations from 2 to 7500 ppb are presented for a hydrophobic molecular sieve at 25%) relative humidity. By increasing the ratio of challenge gas flow rate to the mass of the sorbent bed and decreasing both the mass of sorbent in the bed and the sorbent particle size, this method reduces the required experimental times by a factor of up to several hundred compared with the proposed American Society of Heating, Refrigerating, and Air-Conditioning Engineers method, ASHRAE 145P, making sorbent performance evaluation for ppb-range VOC removal more convenient. The method can be applied to screen sorbent materials for application in the removal of VOCs from indoor air.  相似文献   

13.
Huber S  Haug LS  Schlabach M 《Chemosphere》2011,84(11):1686-1693
Polyfluorinated compounds (PFCs) are an extremely versatile class of compounds and are used in a variety of consumer applications and products. Recent studies have suggested that PFCs in indoor air and dust could act as sources of human exposure and outdoor air contamination. This study presents method development and analysis of a wide range of PFCs in dust and air using active sampling techniques with commercially available sampling equipment (forensic nozzles with filter housings for dust collection and polyurethane foam (PUF)-XAD2-PUF sandwich-tubes for air sampling) using both liquid and gas chromatography mass spectrometry. The developed method was validated and tested for applicability to analyze dust and air samples at both low and high concentrations (0.5 ng and 25 ng per analyte per air sample, respectively). Samples from private households and an office building were analyzed to explore differences in distribution patterns and concentrations. Perfluorooctane sulfonate, perfluorodecane sulfonate, perfluoroheptanoate, perfluorooctanoate and perfluorononanoate were observed in all samples of dust from private households, in the range from 1 to 80.1 ng g−1. Fluorotelomer alcohols (FTOHs) were the predominant PFCs in indoor air samples with ∑FTOHs ranging between 4.7 and 17.9 ng m−3. The concentrations found in the present study are generally lower than those previously reported. This variation may be due to differences associated with geographical locations and lifestyles. However, use of different sampling techniques and strategies among studies can introduce large variations in PFC concentration found, making direct comparisons challenging.  相似文献   

14.
乙酰丙酮分光光度法测定新装修住宅室内空气中的甲醛   总被引:1,自引:0,他引:1  
对乙酰丙酮分光光度法测定室内空气中甲醛的方法进行了优化,同时对北京市11户部分新装修居室室内空气中的甲醛含量进行了测定.结果表明,有8户住宅超过了我国室内空气质量标准GB/T18883-2002规定的甲醛最高容许质量浓度0.10 mg/m3.  相似文献   

15.
对乙酰丙酮分光光度法测定室内空气中甲醛的方法进行了优化,同时对北京市11户部分新装修居室室内空气中的甲醛含量进行了测定.结果表明,有8户住宅超过了我国室内空气质量标准GB/T18883-2002规定的甲醛最高容许质量浓度0.10 mg/m3.  相似文献   

16.
A low-cost air sensor package was used to monitor indoor air quality (IAQ) in a classroom at the Albany Middle School in the San Francisco Bay Area of California. A rapid increase in carbon dioxide (CO2) was observed in the classroom as soon as it is occupied. When the classroom is unoccupied, the CO2 levels decay slowly toward the outdoor background level. All high CO2 concentrations observed inside the classroom, above the outdoor background, was due to exhaling of the occupants. The CO2 concentrations generally exceed the recommended level of 1000 ppb towards the end of the school day. The exceedances and slow decay may suggest that the ventilation rate in this school is not sufficient. The particulate level in the classroom was low until a distant wildfire advected large amount of particulate matter to the San Francisco Bay Area. Very high (10–15 times compared to the background) particle numbers (per m3 of particles with diameter >0.3 µm) were observed in the classroom during the wildfire. These particles were relatively small (0.3–1.0 µm) and the filters (MERV 8) of the ventilation system were unable to filter them out. Therefore, the measurements made by low-cost particle counters can inform the school administrators of adverse IAQ during future wildfire (or other combustion) events. The particle number was independent of the occupation before and during the wildfire suggesting that all observed particles were infiltrated into the classroom from outside. Consistent with previous studies, no appreciable increase in the local ambient CO2 background was observed during this distant wildfire event.

Implications: Low-cost air sensors are effective in monitoring indoor air quality in classrooms. The CO2 levels in classrooms are mainly generated indoors due to exhalation of occupants. Concentration of CO2 generally exceed the recommended level of 1000 ppb towards the end of the school day. In contrast, the particulate matter mostly comes from outdoors and small particles penetrate though the filters normally used at schools. Distant wildfires do not increase the local CO2 background appreciably, but significantly increase the particulate matter concentrations both indoors and outdoors. Further investigations are needed to assure that ventilation rates in classrooms are sufficiently health protective.  相似文献   

17.
A series of modifications were implemented in MM5 simulation in order to account for wind along the Santa Clarita valley, a north–south running valley located in the north of Los Angeles. Due to high range mountains in the north and the east of the Los Angeles Air Basin, sea breeze entering Los Angeles exits into two directions. One branch moves toward the eastern part of the basin and the other to the north toward the Santa Clarita valley. However, the northward flow has not been examined thoroughly nor simulated successfully in the previous studies. In the present study, we proposed four modifications to trigger the flow separation. They were (1) increasing drag over the ocean, (2) increasing soil moisture content, (3) selective observational nudging, and (4) one-way nesting for the innermost domain. The Control run overpredicted near-surface wind speed over the ocean and sensible heat flux, in an urbanized area, which justifies the above 1st and 2nd modification. The Modified run provided an improvement in near-surface temperature, sensible heat flux and wind fields including southeasterly flow along the Santa Clarita valley. The improved MM5 wind field triggered a transport to the Santa Clarita valley generating a plume elongated from an urban center to the north, which did not exist in MM5 Control run. In all, the modified MM5 fields yielded better agreement in both CO and O3 simulations especially in the Santa Clarita area.  相似文献   

18.
An indoor/outdoor monitoring study was conducted during January–March 1982 in Waterbury, Vermont. Respirable particle measurements were made inside and outside 24 homes (all occupants were nonsmokers), 19 with wood-burning appliances and 5 without. Data were also obtained on seasonal air-exchange rate, heating fuel consumption, and relevant home characteristics. Findings indicate that indoor particle levels are consistently higher than outdoor values regardless of heating-fuel type. No statistical difference was observed between 24-h average respirable particle levels in wood- and nonwood-burning homes. A linear regression model, incorporating information on air-exchange rate, house volume, fuel use, and outdoor levels, accounted for about 20% of the variance in indoor particle concentrations.  相似文献   

19.
The aim of this paper is to develop the technique for mapping the air pollution in cities using measured and computed concentrations. It is based on the combined use of deterministic and stochastic modelling. Two different approaches are applied to extrapolate the measurements to the regular grid points covering the city. The first uses the method of the principal components, and the second is based on optimal interpolation or 'kriging' of meteorological fields. The results of the application of this model for the mapping of air pollution in the city of Pskov, Russia, are given.  相似文献   

20.
Environmental Science and Pollution Research - Though globalization, industrialization, and urbanization have escalated the economic growth of nations, these activities have played foul on the...  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号