首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A laminated sediment core collected in the southern part of the Baltic Proper was analysed for DDT compounds, polychlorinated biphenyls (PCB) including the coplanar congeners, polybrominated diphenyl ethers (PBDE) and polychlorinated naphthalenes (PCN). Two sewage sludge samples were also analysed for the same compounds.

The results of the sediment analyses indicate the presence of PCB, DDT and PBDE compounds in sediment layers dating from the 1950s and later. Neither coplanar PCB nor PCN were detected at any level of the sediment core. The PCB concentrations indicate a slight increase in levels during the last decades, while there were no changes in the levels of DDT compounds. In contrast, TeBDE levels increase 4- to 8-fold and one PeBDE congeners levels increase 10- to 20-fold. The results of sewage sludge analyses showed the concentration of the individual PBDE to be at about the same level as for the individual PCB congeners. The congener pattern in sludge samples indicates low-chlorinated products to be the main PCN source.  相似文献   


2.
The concentrations and fluxes of polychlorinated naphthalenes (PCNs) were measured in surface sediments, and settling particulate matter collected in sediment traps, at two coastal and two offshore sampling stations in the Gulf of Bothnia, northern Baltic Sea, Sweden. The PCN concentrations (of tetra- to hepta-chloro congeners) in the surface sediments ranged from 0.27 to 2.8 ng/g dry weight and were of the same order of magnitude as background concentrations reported previously in Europe. The PCN fluxes in the southern basin (0.93 and 0.86 microg/m2/year) of the Gulf of Bothnia were higher than those in the northern basin (0.58 and 0.49 microg/m2/year); they were also higher near the coast than in the open sea. These PCN fluxes are similar to the pre-industrial levels determined from lake sediments in northwest England. The PCN homologue distribution changed from a relatively even distribution in samples collected near the coast, to TeCNs dominating in the samples from the open sea. This indicates that higher chlorinated PCNs are deposited and retained in sediments to a higher degree near the coast. The total annual deposition of PCNs in sediments in the Gulf of Bothnia was estimated to be 91 kg/year.  相似文献   

3.
PCN congeners were analyzed in marine and riverine sediments of the Laizhou Bay area, North China. Concentrations of PCNs ranged from 0.12 to 5.1 ng g1 dry weight (dw) with a mean value of 1.1 ng g1 dw. The levels of PCNs varied largely, with industrial group approximately ten folds higher than those of the rural in riverine sediment. A strong impact by direct discharge from local factories was suggested. Similar compositional profiles were found within groups. High resemblance of compositional profiles between industrial samples and Halowax 1014 was observed. It was indicated that PCNs in riverine sediments were mainly from release of industrial usage, with additional contributions from industrial thermal process at certain sites. In marine sediments, it was suggested that PCNs along the coast of Laizhou Bay were mainly controlled by riverine input. While in the central bay, PCN distributions were possibly impacted by combined multiple factors.  相似文献   

4.
Polychlorinated naphthalenes (PCNs), short-chain chlorinated paraffins (SCCPs) and polychlorinated biphenyls (PCBs) were analysed in marine sediment samples collected from the coastal area of Barcelona (Spain) and near of a submarine emissary coming from a waste water treatment plant located at the mouth of the Besòs River (Barcelona). An integrated sample treatment based on Soxhlet extraction followed by a simple clean-up with Florisil and graphitized carbon cartridge was employed. Gas chromatography coupled to ion-trap tandem mass spectrometry (GC-MS/MS) and gas chromatography-mass spectrometry in electron capture negative ionization mode, were used for PCN and SCCP determinations, respectively, while for PCB analysis gas chromatography with electron capture detection (GC-ECD) was used. The method developed provided low limits of detection (0.001-0.003 ng g(-1) dry weight (dw) for PCNs, 1.8 ng g(-1) for SCCPs and 0.006-0.014 ng g(-1)dw for PCBs) and good run-to-run precisions (lower than RSD 8%) for the analysis of sediment samples. Concentration levels ranging from 0.17 to 3.27 ng g(-1)dw for PCNs, between 0.21 and 1.17 microg g(-1)dw for SCCPs, and from 2.33 to 44.00 ng g(-1) (dw) for PCBs, were found in the coastal sediments, while for samples collected near to the submarine emissary higher levels (from 2.02 to 6.56 ng g(-1)dw for PCNs, between 1.25 and 2.09 microg g(-1)dw for SCCPs and from 22.34 to 37.74 ng g(-1)dw for PCBs) were obtained. The results obtained provide new data about the occurrence of PCN and SCCP in the coastal area of Barcelona.  相似文献   

5.
Jansson S  Fick J  Marklund S 《Chemosphere》2008,72(8):1138-1144
Non- to octa-chlorinated naphthalenes (PCNs) were analyzed in flue gas samples collected simultaneously at three different temperatures (450 degrees C, 300 degrees C and 200 degrees C, respectively) in the post-combustion zone during waste combustion experiments using a laboratory-scale fluidized-bed reactor. PCN homologue profiles in all samples were dominated by the lower chlorinated homologues (mono- to triCN), with successive reductions in abundance with each additional degree of chlorination. The isomer distribution patterns reflected ortho-directionality behavior of the first chlorine substituent, and the beta-positions, i.e. the 2,3,6,7-substitution sites, seemed to be favored for chlorination. Injection of naphthalene into the post-combustion zone resulted in increased PCN levels at 200 degrees C, demonstrating the occurrence of chlorination reactions in the post-combustion zone. However, the increases were restricted to the least-chlorinated homologue (monoCN), probably because there was insufficient residence time for further chlorination. In addition, an episode of poor combustion (manifested by high CO levels) was accompanied by extensive formation of 1,8-diCN, 1,2,3- and 1,2,8-triCN; congeners with substitution patterns that are not thermodynamically favorable. These are believed to be products of PAH breakdown reactions and/or chlorophenol condensation. Overall, PCN formation is likely to occur via more than one pathway, including chlorination of naphthalene that is already present, de novo synthesis from PAHs and, possibly, chlorophenol condensation.  相似文献   

6.
Twenty-seven surface sediment samples were collected from the mainstream and eight tributaries of the Wuhan reach of the Yangtze River, China, in 2005, in order to assess the distribution, possible sources, and potential risk of polychlorinated biphenyls (PCBs) in the environment. The total concentrations of PCBs (the sum of 39 congeners) ranged from 1.2 to 45.1 ng g−1 dry weight, with a mean value of 9.2 ng g−1. Sediment samples with the highest PCB concentrations came from the tributary sites, which are closer to PCB sources. Conversely, PCB concentrations in the sediment from the mainstream sites of Yangtze River were relatively low. The observed PCB levels were higher than those found in the sediments of other rivers in China, but lower than those in river sediments from other urban areas and harbors around the world. Low-chlorinated PCBs, dominated by tetra-PCBs and penta-PCBs, were identified as being prevalent in the surface sediments. Correlation analyses between the PCBs and the geochemistry and heavy metal content of the sediments suggest that the washing of these compounds from the land into the river by floods and heavy rains, or industrial wastewater and domestic sewage, may be the major sources of the PCBs. According to established sediment quality guidelines, the risk of adverse biological effects from the levels of PCBs recorded at most of the studied sites should be insignificant, although the higher concentrations at other sites could cause acute biological damage.  相似文献   

7.
Evidently increased environmental pollution as a consequence of the 25-year manufacture of polychlorinated biphenyls (PCBs) in eastern Slovakia was observed. PCB levels determined in ambient air, soil, surface water, bottom sediment, wildlife (fish and game) samples collected in a potentially contaminated area of about 250 km2 (a part of the Michalovce district) were compared with those determined in a control area (Stropkov district). Up to 1700 ng/m3 were found in ambient air in a village close to a manufacturer's dumping site and a highly contaminated manufacturer's effluent canal whereas PCB concentrations in ambient air samples taken in villages in the control area were about 80 ng/m3 only. While soil samples taken from the agricultural fields of the polluted area contained PCBs at levels comparable with soil samples from the control area (about 0.008 mg/kg) much higher values (from 0.4 to 53,000 mg/kg) were determined in soil taken in the vicinity of manufacturer's landfill and storage sites and especially plants preparing asphalted gravel using formerly PCBs in their heat-exchanging systems. The contamination of the Laborec river and large Zemplinska Sirava reservoir is caused by the manufacturer's effluent canal since PCB levels in the canal sediment are still to be found about 3000 mg/kg. While PCB levels in sediment samples from Michalovce watercourses ranged between 1.7 and 6 mg/kg, sediment samples from the control Stropkov district ranged between 0.007 and 0.052 mg/kg only. Fish living in contaminated Michalovce waters contained about hundred times higher PCB levels than those caught in Stropkov ones. Similarly, game animals shot in Michalovce forests contained several times higher levels than those shot in Stropkov ones.  相似文献   

8.
A method for the analysis of polychlorinated naphthalenes (PCN) has been developed. It is based on a simple clean-up procedure using activated carbon and a mass fragmentographic analysis using the negative ions formed during chemical ionization (NCI). Unlike the technical PCN products we have analyzed, a few isomerides containing four to six chlorine atoms dominate the PCN pattern in the environmental samples. The levels found in samples of biota from fresh water and marine environments in Sweden were between 3 and 62 ng PCN per gram lipid.  相似文献   

9.
Imagawa T  Lee CW 《Chemosphere》2001,44(6):1511-1520
Isomer composition of polychlorinated naphthalenes (PCNs) was measured for municipal waste incinerator fly ash samples and for emission samples produced from soot and copper-deposit experiments conducted at the United States Environmental Protection Agency (US-EPA). Two types of PCN isomer patterns were identified. One pattern contained specific PCN isomers in which chlorine atoms are substituted as if the peri(alpha-) position were dechlorinated from the higher chlorinated PCNs one by one. In another pattern, the isomers had a tendency for the chlorine atoms to assume successive positions on the naphthalene ring, which may be caused by specifically oriented chlorination. Some of these isomers increased, together with several polychlorinated dibenzofuran (PCDF) and a few polychlorinated dibenzo-p-dioxin (PCDD) isomers. The ratios between some specific PCN, PCDF, and PCDD isomers measured for the fly ash samples agree with those obtained from the soot and copper-deposit experiments. The observations suggest that these isomers were formed possibly from de novo synthesis utilizing the carbon structure contained in soot under the catalytic effect of a copper compound. Typical isomers for PCNs and PCDFs produced from incineration emissions were identified.  相似文献   

10.
Polychlorinated naphthalenes (PCNs) have been proposed for inclusion in the annexes of the Stockholm Convention by the European Union, signifying a probable increase in monitoring PCN levels at a global level. Investigations on PCN levels in the environment of Hong Kong have not been reported. In this preliminary investigation, PCN levels in surface soils samples were determined by isotope dilution HRGC/HRMS techniques, and compared with those of polychlorinated biphenyl (PCBs), polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs). The concentrations of PCNs in the soil samples were 35–883 pg g?1 (average, 201; and median, 94 pg g?1), which were lower than those of PCBs PCDDs and PCDFs. This comparison suggested that PCNs are currently not priority POPs compared with dioxins and PCBs in Hong Kong soils. PCDDs were the most important contributor to the sum of toxic equivalents of PCNs, PCBs, PCDDs and PCDFs. OCDD was the most dominant dioxin congener in Hong Kong surface soils. PCB-118 was the most abundant in 12 dl-PCB congeners. PCN congeners indicating thermal related sources (CN52/60, CN66/67 and CN73) were relatively abundant in their respective homologs, which suggested PCN contamination from thermal sources. The ratio of CN73 to CN74 in soil samples suggested the contribution of PCN contaminations in soils from both thermal-related sources and evaporative emissions of technical PCN mixtures.  相似文献   

11.
Superficial and cored sediment samples from the Moulay Bousselham lagoon and sub-watershed were analyzed for Al, Fe, Cu, Zn, Pb, Mn, Ni, Cr, As, Hg, and Cd. The temporal and spatial distributions of the main contamination sources of heavy metals were identified and described using chemometric and geographic information system (GIS) methods. Sediments from coastal lagoons near urban and agricultural areas are commonly contaminated with heavy metals, and the concentrations found in surface sediments are significantly higher than those from 50–100 years ago. The concentrations of these elements decrease sharply with depth in the sediment column, and the elements are preferentially enriched in the <2-μm-sized fraction of the sediment. The zones of enhanced risk of heavy metals were detected by means of GIS-based geostatistical modeling. According to sediment pollution indices and statistical analysis, heavy metals (Pb, Cu, Ni, Zn, Cr, and Hg) that pose a risk have become largely enriched in the lagoon sediments during the recent period of agricultural intensification.  相似文献   

12.
The concentrations of polychlorinated dibenzo-p-dioxins and furans (PCDD/Fs), polychlorinated biphenyls (PCBs) and polychlorinated naphthalenes (PCNs) were determined in air samples collected at four sampling sites located in two zones of Barcelona (Spain): near a municipal solid waste incinerator (MSWI) and a combined cycle power plant (3 sites), and at a background/control site. Samples were collected using high-volume active samplers. Moreover, 4 PUF passive samplers were deployed at the same sampling points during three months. For PCDD/Fs, total WHO-TEQ values were 27.3 and 10.9 fg WHO-TEQm(-3) at the urban/industrial and the background sites, respectively. The sum of 7 PCB congeners and the Sigma PCN levels were also higher at the industrial site than at the background site. In order to compare active and passive sampling, the accumulated amounts of PCDD/Fs, PCBs and PCNs in the four passive air samplers, as well as the total toxic equivalents in each sampling site were also determined. To assess the use of PUF passive samplers as a complementary tool for PCDD/F, PCB and PCN monitoring, sampling rates were calculated in accordance with the theory of passive air samplers. PUF disks allowed establishing differences among zones for the POP levels, showing that they can be a suitable method to determine POP concentrations in air in areas with various potential emission sources. Although both particle and gas phase were sorbed by the PUFs, data of gas phase congeners are more reproducible.  相似文献   

13.
We determined the concentrations of 35 PCNs, 12 PCBs, and 20 PAHs in 49 urban topsoils under different land use (house garden, roadside grassland, alluvial grassland, park areas, industrial sites, agricultural sites) and in nine rural topsoils. The sums of concentrations of 35 PCNs (sigma35 PCNs) were <0.1-15.4 microg kg(-1) in urban soils and <0.1 to 0.82 microg kg(-1) in rural soils. The PCN, PCB, and PAH concentrations were highest at industrial sites and in house gardens. While rural soils receive PCNs, PCBs, and PAHs by common atmospheric deposition, there are site-specific sources of PCNs, PCBs, and PAHs for urban soils such as deposition of contaminated technogenic materials. The PCN, PCB, and PAH concentrations decreased from the central urban to the rural area. In the same order the contribution of lower chlorinated PCNs and PCBs increased because they are more volatile and subject to increased atmospheric transport. The PCNs 52+60, and 73 were more abundant in soil samples than in Halowax mixtures, indicating that combustion contributed to the PCN contamination of the soils.  相似文献   

14.

A total of 47 passive air samples and 25 soil samples were collected to study the temporal trend, distribution, and air–soil exchange of polychlorinated naphthalenes (PCNs) in Shanghai, China. Atmospheric PCNs ranged from 3.44 to 44.1 pg/m3 (average of 21.9 pg/m3) in summer and 13.6 to 153 pg/m3 (average of 40.0 pg/m3) in winter. In the soil samples, PCN concentrations were 54.7–1382 pg/g dry weight (average of 319 pg/g). Tri-CNs and tetra-CNs were two dominant homolog groups in air samples, while di-CNs were also found at comparable proportions to tri-CNs and tetra-CNs in soil samples. Most air and soil samples from the industrial and urban areas showed higher PCN concentrations than those from suburban areas. However, some soil samples in urban centers presented higher PCN concentrations than industrial areas. Analysis of PCN sources indicated that both industrial thermal process and historical usage of commercial PCN mixtures contributed to the PCN burden in most areas. The fugacity fraction results indicated a strong tendency of volatilization for lighter PCNs (tri- to hexa-CNs) in both seasons, and air–soil deposition for octa-CNs. Moreover, air–soil exchange fluxes indicate that soil was an important source of atmospheric PCNs in some areas. The results of this study provide information for use in the evaluation of the potential impact and human health risk of PCNs around the study areas.

  相似文献   

15.
Wastewater impoundments at concentrated animal feeding operations (CAFOs) represent a potential source of veterinary pharmaceuticals and steroid hormone contamination to shallow groundwater. This study investigates the occurrence of seventeen veterinary pharmaceuticals and thirteen steroid hormones and hormone metabolites in lagoons and adjacent groundwater at operating swine and beef cattle facilities. These sites were chosen because subsurface geology and previous monitoring of nitrate, ammonia and chloride levels in shallow ground water strongly indicated direct infiltration, and as such represent worst cases for ground water contamination by waste water. Pharmaceutical compounds detected in samples obtained from cattle facilities include sulfamerazine; sulfamethazine; erythromycin; monensin; tiamulin; and sulfathiazole. Lincomycin; ractopamine; sulfamethazine; sulfathiazole; erythromycin; tiamulin and sulfadimethoxine were detected in wastewater samples obtained from swine facilities. Steroid hormones were detected less frequently than veterinary pharmaceuticals in this study. Estrone, testosterone, 4-androstenedione, and androsterone were detected in wastewater impoundments at concentrations ranging from 30 to 3600ng/L, while only estrone and testosterone were detected in groundwater samples at concentrations up to 390ng/L. The co-occurrence of veterinary pharmaceutical and steroid hormone contamination in groundwater at these locations and the correlation between pharmaceutical occurrence in lagoon wastewater and hydraulically downgradient groundwater indicates that groundwater underlying some livestock wastewater impoundments is susceptible to contamination by veterinary pharmaceuticals and steroid hormones originating in wastewater lagoons.  相似文献   

16.
Abad E  Caixach J  Rivera J 《Chemosphere》1999,38(1):109-120
Polychloronaphthalenes (PCN) were identified and quantified in emission samples collected from five different municipal waste incinerators (MWI). Polychlorodibenzo-p-dioxins (PCDD) and polychlorodibenzofurans (PCDF) were also determined to find a possible relationship between these classes of organochlorinated compounds. The analyses of PCDD/PCDF and PCN were carried out by high resolution gas chromatography coupled with high resolution mass spectrometry using a positive electron ionization source and operating in the selected ion monitoring analyzer mode (HRGC-HRMS/EI(+)-SIM). The total levels of PCN varied from 1.08 up to 21.36 ng/Nm3 (mono- to octachlorinated) and 0.33 to 5.72 ng/Nm3 (tetra- to octachlorinated), whereas the levels of PCDD/PCDF ranged between 1.14 and 276.26 ng/Nm3 (0.01 and 5 ng I-TEQ/Nm3), depending on the type of the MWI. These findings do not corroborate a PCN and PCDD/PCDF correlation.  相似文献   

17.
Llobet JM  Falcó G  Bocio A  Domingo JL 《Chemosphere》2007,66(6):1107-1113
The concentrations of polychlorinated naphthalenes (PCNs) were determined in samples of 14 edible marine species (sardine, tuna, anchovy, mackerel, swordfish, salmon, hake, red mullet, sole, cuttlefish, squid, clam, mussel and shrimp), which are widely consumed by the population of Catalonia, Spain. The daily intake of PCNs associated with this consumption was also determined. A total of 42 composite samples were analyzed by HRGC/HRMS. The highest PCN levels (ng/kg of fresh weight) were found in salmon (227) followed by mackerel (95) and red mullet (68), while the lowest levels of total PCNs corresponded to shrimp (4.9) and cuttlefish (2.7). With the exception of cephalopods and shellfish species, in which tetra-CN was the predominant homologue, penta-CN (60%) was the predominant contributor to total PCNs. For a standard male adult, PCN intake through the consumption of edible marine species was 1.53 ng/day. The highest contributions to this intake (ng/day) corresponded to salmon (0.41), sole (0.28) and tuna (0.24). Concerning health risks, species-specific TEFs such as those reported by WHO and NATO for PCDD/Fs and dioxin-like PCBs are not currently available for PCN congeners. Although in general terms the results of the present study do not seem to suggest specific risks derived from exposure to PCNs through fish and seafood consumption, to establish the contribution of individual PCN congeners to total TEQ is clearly necessary for the assessment of human health risks.  相似文献   

18.
Nematode communities from river water and sediments were assessed for the abundance, feeding types, maturity indices and nematode channel ratio (NCR). The sampling sites studied included different levels of pollution and contamination from agricultural, industrial and sewage sources. The nematode abundance found in the sediment samples was more than that in the water samples. The lowest nematode abundance in sediment samples and the lowest NCR in water samples were both found at the industrial pollution site. Water samples showed positive correlation between the NCR and river pollution index (RPI). Mean maturity indices in sediment samples were inversely correlated with RPI. The pollutant source determined the relationship between NCR and pollution level, while maturity index always showed negative correlation with pollutant level regardless of the pollutant sources. The nematode abundance and its community structure were both reliable bioindicators for monitoring long-term river pollution in both qualitative and quantitative aspects.  相似文献   

19.
Determination of polychlorobiphenyls in Venice Lagoon sediments   总被引:1,自引:0,他引:1  
Polychlorinated biphenyl (PCBs) congeners were measured in 14 sediment samples collected at five sites in the Venice Lagoon selected on the basis of a supposed diversity of inputs and of pollution levels. The PCBs were determined after a sonication assisted extraction by gas chromatography mass spectrometry (GCMS). The sum of the congener concentrations determined in the samples range from 4.05 to 239.15 ng/g on a dry weight basis. The concentration values are very variable both comparing the sites and comparing different samples from the same site and can be connected to the sand percentage in the sediment samples. The correlation matrix obtained from data matrix using the congener concentrations as variables shows high values, mostly between 0.964 and 1, suggesting that the pattern of the PCB congeners and the ratios among the concentrations in Venice Lagoon sediments are more or less constant; the samples differ only in the concentration level.  相似文献   

20.
Ishaq R  Näf C  Zebühr Y  Broman D  Järnberg U 《Chemosphere》2003,50(9):1131-1150
Methodology for the determination of biologically active polychlorinated biphenyls (PCBs), non-ortho PCBs, polychlorinated naphthalenes (PCNs), polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), polycyclic aromatic hydrocarbons (PAHs) was used to investigate concentrations and patterns of certain chlorinated PAH (Cl-PAH) in source related samples using synthetic reference mixtures. Thus, in addition to the above mentioned compounds, mono-heptachlorosubstituted fluorenes, phenanthrenes/anthracenes and pyrenes/fluoranthenes (Cl-PAHs) were measured in vapour and particulate air samples from urban road tunnels, samples of settling particulate matter (SPM), and in bottom sediment samples from two point source locations (pulp and paper, and Mg-plant/Fe-Mn-smelter/chlor-alkali) and in the Baltic Sea. Concentrations in air samples followed: PAHs>PCBs>PCNs>non-ortho PCBs or Cl-PAHs>PCDD/Fs. SPM samples collected at increasing distance to the urban area of Stockholm showed: PAHs>PCBs>PCNs>PCDD/Fs>non-ortho PCBs or Cl-PAHs. For all compound groups there was a tenfold (Cl-PAHs fivefold) concentration decrease in SPM samples from highest levels in the urban water area to lowest levels at a distance of 26 km from city centre. PCB profiles of SPM showed similarities with combined profiles of Aroclor 1242 and 1254. PCN profiles of SPM showed similarities with combined profiles of Halowax 1099 and 1014. A correlation with concentration of all tested Cl-PAH and their corresponding parent PAH was found only for Cl-fluorene.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号