首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
Abstract

The aim of this study was to produce Bacillus thuringiensis-based biopesticide using starch-producing industry wastewater (SIW) fortified with soybean medium and optimize the formulated product using different adjuvants. This study was necessary as low endotoxin concentration is obtained in formulated biopesticide when SIW alone is used as fermentation medium. The fermentation runs were conducted using SIW alone and SIW fortified with 25% soybean (w/v) medium in 2000?L and 150?L bioreactor, respectively. SIW supplemented with soybean medium showed an increase in cell count (from 1.95?×?108 to 1.65?×?109 CFU mL–1), spore synthesis (from 1.5?×?108 to 1.35?×?109 CFU mL–1) and endotoxin concentration (from 436 to 1170?μg mL–1) when compared to SIW medium alone. The fermented broth was concentrated using continuous centrifugation and adjuvants were added for biopesticide formulation in order to enhance its resistance against UV rays and rainfastness. Entomotoxicity of the formulation produced using fermented broth of SIW fortified with soybean (38,000?IU μL–1) was higher than that obtained by SIW medium alone (21,000?IU μL–1), commercial biopesticide Foray 76B (20,000?IU μL–1) and Btk sander’s (12,500?IU μL–1).  相似文献   

2.
Phenoxyacetic and benzoic acid herbicides are widely used agricultural, commercial, and domestic pesticides. As a result of high water solubility, mobility, and persistence, 2,4-dichlorophenoxyacetic acid (2,4-D), methylchlorophenoxypropionic acid (mecoprop), and 3,6-dichloro-2-methoxybenzoic acid (dicamba) have been detected in surface and waste waters across Canada. As current municipal wastewater treatment plants do not specifically address chronic, trace levels of contaminants like pesticides, an urgent need exists for an efficient, environmentally friendly means of breaking down these toxic herbicides. A commercially available herbicide mix, WeedEx, containing 2,4-D, mecoprop, and dicamba, was subjected to treatment using membrane bioreactor (MBR) technology. The three herbicides, in simulated wastewater with a chemical oxygen demand of 745 mg/L, were introduced to the MBR at concentrations ranging from 300 μg/L to 3.5 mg/L. Herbicides and biodegradation products were extracted from MBR effluent using solid-phase extraction followed by detection using high-performance liquid chromatography coupled with mass spectrometry. 2,4-D was reduced by more than 99.0 % within 12 days. Mecoprop and dicamba were more persistent and reduced by 69.0 and 75.4 %, respectively, after 112 days of treatment. Half-lives of 2,4-D, mecoprop and dicamba during the treatment were determined to be 1.9, 10.5, and 28.3 days, respectively. Important water quality parameters of the effluent such as dissolved oxygen, pH, ammonia, chemical oxygen demand, etc. were measured daily. MBR was demonstrated to be an environmentally friendly, compact, and efficient method for the treatment of toxic phenoxyacetic and benzoic acid herbicides.  相似文献   

3.
Three different combinations of treatment techniques, i.e. electrocoagulation combined with microfiltration (EMR), membrane bioreactor (MBR) and electrocoagulation integrated with membrane bioreactor (hybrid MBR, (HMBR)), were analysed and compared for the treatment of tannery wastewater operated for 7 days under the constant trans-membrane pressure of 5 kPa. HMBR was found to be most suitable in performance as well as fouling reduction, with 94 % of chemical oxygen demand (COD) removal, 100 % chromium removal and 8 % improvement in percentage reduction in permeate flux compared to MBR with only 90 % COD removal and 67 % chromium removal. The effect of mixed liquor suspended solids on fouling was also investigated and was found to be insignificant. EMR was capable of elevating the flux but was not as efficient as HMBR and MBR in COD removal. Fouling reduction by HMBR was further confirmed by SEM-EDX and particle size analysis.  相似文献   

4.
The purpose of the study was the experimental evaluation of ultrafiltration as a potential innovative technology for the removal of organic matter of around 15,000 mg chemical oxygen demand (COD) per liter in the polymer industry wastewater. Particle size distribution (PSD) analysis served as the major experimental instrument along with conventional chemical settling. Biodegradation characteristics of the remaining COD after ultrafiltration were determined by model interpretation of the corresponding oxygen uptake rate (OUR) profile. The study first involved a detailed characterization of the polymer wastewater including PSD analysis of the COD content. Chemical treatability was investigated using lime alone and with ferric chloride as coagulants followed with a PSD assessment of the chemically settled effluent. Modeling of the OUR profile generated by the ultrafiltration effluent defined related biodegradation kinetics and provided information on the overall COD removal potential. PSD analysis indicated that more than 70 % of the total COD accumulated in the 220- to 450-nm size range. It indicated that ultrafiltration was potentially capable of removing more than 90 % of the COD with an effluent lower than 1,500 mg COD/L. Chemical settling with 750 mg/L of FeCl3 dosing at a pH of 7.0 provided a similar performance. The ultrafiltration effluent included mainly hydrolysable COD and proved to be biodegradable, with the process kinetics compatible with domestic sewage. PSD evaluation proved to be a valuable scientific instrument for underlining the merit of ultrafiltration as the appropriate innovative technology for polymer wastewater, removing the major portion of the COD in a way that is suitable for recovery and reuse and producing a totally biodegradable effluent.  相似文献   

5.
Biopesticides are usually sprayed on forests by using planes made up of aluminum alloy. Bioval derived from starch industry wastewater (SIW) in suspension form was developed as stable anticorrosive biopesticide formulation. In this context, various anticorrosion agents such as activated charcoal, glycerin, ethylene glycol, phytic acid, castor oil and potassium silicate were tested as anticorrosive agents. There was no corrosion found in Bioval formulation where potassium silicate (0.5% w/v) was added and compared with Foray 76 B, as an industrial standard, when stored over 6 months. In relation to other parameters, the anticorrosion formulation of Bioval+buffer+KSi reported excellent zeta potential (?33.19 ± 4 mV) and the viscosity (319.13 ± 32 mPa.s) proving it's stability over 6 months, compared to the standard biopesticide Foray 76 B (?36.62 ± 4 mV potential zeta, pH 4.14 ± 0.1 and 206 ± 21 mPa.s viscosity). Metal analysis of the different biopesticides showed that Bioval+buffer+KSi has no corrosion (5.11 ± 0.5 mg kg?1 of Al and 13.53 ± 1.5 mg kg?1 of Fe) on the aluminum alloy due to the contribution of sodium acetate buffer at pH 5. The bioassays reported excellent results for Bioval+Buffer+KSi (2.95 ± 0.3 × 109 CFU mL?1 spores and 26.6 ± 2.7 × 109 IU L?1 Tx) compared with initial Bioval (2.46 ± 0.3 × 109 CFU mL?1 spores and 23.09 ± 3 × 109 IU L?1 Tx) and Foray 76 B (2.3 ± 0.2 × 109 CFU mL?1 spores and 19.950 ± 2.1 UI L?1 Tx) which was due to the break-up of the external chitinous membrane due to abrasive action of potassium silicate after ingestion by insects. The contribution of sodium acetate buffer and potassium silicate (0.5% and at pH = 5) as anticorrosion agent in the Bioval allowed production of an efficient biopesticide with a reduced viscosity and favorable pH as compared to Foray 76 B which enhanced the entomotoxic potential against spruce budworm (SB) larvae (Lepidoptera: Choristoneura fumiferana).  相似文献   

6.
The rice-husk-based mesoporous activated carbon (MAC) used in this study was precarbonized and activated using phosphoric acid. N2 adsorption/desorption isotherm, X-ray powder diffraction, electron spin resonance, X-ray photoelectron spectroscopy and scanning electron microscopy, transmission electron microscopy, 29Si-NMR spectroscopy, and diffuse reflectance spectroscopy were used to characterize the MAC. The tannery wastewater carrying high total dissolved solids (TDS) discharged from leather industry lacks biodegradability despite the presence of dissolved protein. This paper demonstrates the application of free electron-rich MAC as heterogeneous catalyst along with Fenton reagent for the oxidation of persistence organic compounds in high TDS wastewater. The heterogeneous Fenton oxidation of the pretreated wastewater at optimum pH (3.5), H2O2 (4 mmol/L), FeSO4?7H2O (0.2 mmol/L), and time (4 h) removed chemical oxygen demand, biochemical oxygen demand, total organic carbon and dissolved protein by 86, 91, 83, and 90 %, respectively.  相似文献   

7.
Conventional wastewater treatment is challenging in the Arctic region due to the cold climate and scattered population. Thus, no wastewater treatment plant exists in Greenland, and raw wastewater is discharged directly to nearby waterbodies without treatment. We investigated the efficiency of physicochemical wastewater treatment, in Kangerlussuaq, Greenland. Raw wastewater from Kangerlussuaq was treated by chemical coagulation and UV disinfection. By applying 7.5 mg Al/L polyaluminium chloride (PAX XL100), 73% of turbidity and 28% phosphate was removed from raw wastewater. E. coli and Enterococcus were removed by 4 and 2.5 log, respectively, when UV irradiation of 0.70 kWh/m3 was applied to coagulated wastewater. Furthermore, coagulated raw wastewater in Denmark, which has a chemical quality similar to Greenlandic wastewater, was disinfected by peracetic acid or UV irradiation. Removal of heterotrophic bacteria by applying 6 and 12 mg/L peracetic acid was 2.8 and 3.1 log, respectively. Similarly, removal of heterotrophic bacteria by applying 0.21 and 2.10 kWh/m3 for UV irradiation was 2.1 and greater than 4 log, respectively. Physicochemical treatment of raw wastewater followed by UV irradiation and/or peracetic acid disinfection showed the potential for treatment of arctic wastewater.  相似文献   

8.
Identification and removal of polycyclic aromatic hydrocarbons (PAHs) were investigated at two coke plants located in Shaoguan, Guangdong Province of China. Samples of raw coking wastewaters and wastewaters from subunits of a coke production plant were analyzed using gas chromatography–mass spectrometry (GC/MS) to provide a detailed chemical characterization of PAHs. The identification and characterization of PAH isomers was based on a positive match of mass spectral data of sample peaks with those for PAH isomers in mass spectra databases with electron impact ionization mass spectra and retention times of internal reference compounds. In total, 270 PAH compounds including numerous nitrogen, oxygen, and sulfur heteroatomic derivatives were positively identified for the first time. Quantitative analysis of target PAHs revealed that total PAH concentrations in coking wastewaters were in the range of 98.5?±?8.9 to 216?±?20.2 μg/L, with 3-4-ring PAHs as dominant compounds. Calculation of daily PAH output from four plant subunits indicated that PAHs in the coking wastewater came mainly from ammonia stripping wastewater. Coking wastewater treatment processes played an important role in removing PAHs in coking wastewater, successfully removing 92 % of the target compounds. However, 69 weakly polar compounds, including PAH isomers, were still discharged in the final effluent, producing 8.8?±?2.7 to 31.9?±?6.8 g/day of PAHs with potential toxicity to environmental waters. The study of coking wastewater herein proposed can be used to better predict improvement of coke production facilities and treatment conditions according to the identification and removal of PAHs in the coke plant as well as to assess risks associated with continuous discharge of these contaminants to receiving waters.  相似文献   

9.
Considering the increasing incorporation of manufactured nano-material into consumer products, there is a concern about its potential impacts in biological wastewater treatment. In this study, the response of anaerobic sludge to the presence of Bi2WO6 nano-particles (NPs) was investigated in the anaerobic membrane bioreactor (AnMBR). As the concentration of Bi2WO6 in the reactor was controlled around 1 mg/L, there was no significant difference in effluent water quality or bacterial activities before and after NP exposure, partially due to the microbial-induced NP aggregation and stable complex formation. However, with the increasing dosage of Bi2WO6 from 5 to 40 mg/L, great influences on the AnMBR performance were observed, including the reduction of COD removal efficiency, inhibition of the mechanization step, increased production of soluble microbial products, and enhanced secretion of extracellular polymer substrates. Additional investigation with high-throughput sequencing was conducted, clearly demonstrating that Bi2WO6 NPs induced changes in the bacterial community.  相似文献   

10.
Although the long incubation time of biochemical oxygen demand (BOD7) measurements has been addressed by the use of microbial biosensors, the resulting sensor-BOD values gained from the measurements with specific industrial wastewaters still underestimates the BOD value of such samples. This research aims to provide fast and more accurate BOD measurements in the dairy wastewater samples. Unlike municipal wastewater, wastewater from the dairy industry contains many substrates that are not easily accessible to a majority of microorganisms. Therefore, a bacterial culture, Microbacterium phyllosphaerae, isolated from dairy wastewater was used to construct a semi-specific microbial biosensor. A universal microbial biosensor based on Pseudomonas fluorescens, which has a wide substrate spectrum but is nonspecific to dairy wastewater, was used as a comparison. BOD biosensors were calibrated with OECD synthetic wastewater, and experiments with different synthetic and actual wastewater samples were carried out. Results show that the semi-specific M. phyllosphaerae-based microbial biosensor is more sensitive towards wastewaters that contain milk derivates and butter whey than the P. fluorescens-based biosensor. Although the M. phyllosphaerae biosensor underestimates the BOD7 value of actual dairy wastewaters by 25–32 %, this bacterial culture is more suitable for BOD monitoring in dairy wastewater than P. fluorescens, which underestimated the same samples by 46–61 %.  相似文献   

11.
马铃薯淀粉废水属高浓度废水,COD达到30 000 mg/L左右,BOD为15 000 mg/L左右,可生化性较好。针对废水中主要含有淀粉、蛋白质和可溶性纤维等成分,筛选分离出能降解这些有机成分的6种酵母。以废水为培养液分别培养这6种酵母及其混合菌,实验结果表明,各酵母菌株对该废水都有较好的降解效果,混合菌的处理效果要好于单个菌株。在连续流废水培养条件下,混合酵母活性和菌体量也较高,MLSS稳定在12 g/L左右,其COD去除率稳定在77%左右。  相似文献   

12.
高强度好氧反应器(jet-loop compact reactor,JLCR)采用射流曝气强制溶氧.对JLCR处理制药废水进行了试验研究,考察了JLCR的运行效果、反应器的启动与污泥驯化、抗冲击负荷性能以及污泥沉降性能等.初步结果表明,该系统启动时间较短,运行稳定,COD去除效果较好.进水COD为8000 mg/L左右时,去除率达到80%.  相似文献   

13.
The catalysts such as Fe, Bi2O3, and Fe-doped Bi2O3 were synthesized for the sonophotocatalytic treatment of synthetic dye and real textile wastewater. The resultant catalysts were characterized for its size and uniform shape using x-ray diffractogram (XRD) and scanning electron microscopy (SEM) which signified the nanorod shape formed Bi2O3. The higher ultraviolet light absorbance capacity of the catalysts was also evident using diffuse reflectance spectroscopy (DRS). Initially, the effect of conventional parameters such as initial pH, gas bubbling (argon, oxygen, air and nitrogen) and oxidant addition (H2O2 and peroxymonosulfate) in the presence of sonolysis (22 and 37 kHz frequency) and photolysis (UV-C light) on 10 ppm Basic Brown 1 dye was studied. The results showed that highest decolorization of 62 % was attained for 3 g/L peroxymonosulfate under 37 kHz frequency sonolysis treatment. Secondly, with the catalyst study, highest of 46 % dye color removal was obtained with 4 g/L Fe under 37 kHz frequency sonolysis treatment. The sonophotocatalytic treatment of dye with Fe-doped Bi2O3 catalyst in combination with peroxymonosulfate showed highest color removal of 99 %. Finally, the sonophotocatalytic treatment of real textile wastewater in the presence of 3 g/L Fe-doped Bi2O3 and 6 g/L peroxymonosulfate reduced the total organic carbon (TOC) and chemical oxygen demand (COD) level to 77 and 91 %, respectively, in 180 min. The reported treatment process was found to treat the synthetic dye and real textile wastewater effectively.  相似文献   

14.
This study compares the performance of simulated shallow ponds vegetated with Lemna minor L. under controlled and semi-natural conditions for the treatment of simulated wastewater containing textile dyes. The objectives were to assess the water quality outflow parameters, the potential of L. minor concerning the removal of chemical oxygen demand (COD) and four azo dyes (Acid blue 113, reactive blue 198, Direct Orange 46 and Basic Red 46) and the plants’ growth rate. Findings show that all mean outflow values of COD, total dissolved solids (TDS) and electrical conductivity (EC) were significantly (p < 0.05) lower within the outdoor compared to the indoor experiment except the dissolved oxygen (DO). The COD removal was low for both experiments. The outflow TDS values were acceptable for all ponds. The pond systems were able to reduce only BR46 significantly (p < 0.05) for the tested boundary conditions. Removals under laboratory conditions were better than those for semi-natural environments, indicating the suitability of operating the pond system as a polishing step in warmer regions. The mean outflow values of zinc and copper were below the thresholds set for drinking and irrigation waters and acceptable for L. minor. The dyes inhibited the growth of the L. minor.  相似文献   

15.
A newly designed continuous-flow 915 MHz microwave wastewater treatment system was used to demonstrate the effectiveness of the microwave enhanced advanced oxidation process (MW/H2O2-AOP) for treating dairy manure. After the treatment, about 84% of total phosphorus and 45% of total chemical oxygen demand were solubilized with the highest H2O2 dosage (0.4% H2O2 per %TS). The reaction kinetics of soluble chemical oxygen demand revealed activation energy to be in the range of 5–22 kJ mole?1. The energy required by the processes was approximately 0.16 kWh per liter of dairy manure heated. A higher H2O2 dosage used in the system had a better process performance in terms of solids solubilization, reaction kinetics, and energy consumption. Cost-benefit analysis for a farm-scale MW/H2O2-AOP treatment system was also presented. The results obtained from this study would provide the basic knowledge for designing an effective farm-scale dairy manure treatment system.  相似文献   

16.
The occurrence and removal of six pharmaceuticals and personal care products (PPCPs) including caffeine (CF), N, N-diethyl-meta-toluamide (DEET), carbamazepine, metoprolol, trimethoprim (TMP), and sulpiride in a municipal wastewater treatment plant (WWTP) in Shanghai, China were studied in January 2013; besides, grab samples of the influent were also taken every 6 h, to investigate the daily fluctuation of the wastewater influent. The results showed the concentrations of the investigated PPCPs ranged from 17 to 11,400 ng/L in the WWTP. A low variability of the PPCP concentrations in the wastewater influent throughout the day was observed, with the relative standard deviations less than 25 % for most samples. However, for TMP and CF, the slight daily fluctuation still reflected their consumption patterns. All the target compounds except CF and DEET, exhibited poor removal efficiencies (<40 %) by biological treatment process, probably due to the low temperature in the bioreactor, which was unfavorable for activated sludge. While for the two biodegradable PPCPs, CF, and DEET, the anaerobic and oxic tank made contributions to their removal while the anoxic tank had a negative effect to their elimination. The tertiary UV treatment removed the investigated PPCPs by 5–38 %, representing a crucial polishing step to compensate for the poor removal by the biologic treatment process in winter.  相似文献   

17.
Scale-up of anodic oxidation system is critical to the practical application of electrochemical treatment in bio-refractory organic wastewater treatment. In this study, the scale-up of electrochemical flow system was investigated by treating petrochemical wastewater using platinized titanium (Ti/Pt) and boron-doped diamond (BDD) anodes. It was demonstrated that flow cell was successfully scaled-up because when it was compared with batch mode (Rocha et al. 2012b), higher performances on organic matter removal were achieved. Under the suitable operating conditions and better anode material, the chemical oxygen demand (COD) of petrochemical wastewater was reduced from 2,746 to 200 mg L?1 within 5 h with an energy consumption of only 56.2 kWh m?3 in the scaled-up BDD anode system. These results demonstrate that anode flow system is very promising in practical bio-refractory organic wastewater treatment.  相似文献   

18.
Chen TY  Kao CM  Yeh TY  Chien HY  Chao AC 《Chemosphere》2006,64(3):497-502
The main objective of this study was to examine the efficacy and capacity of using constructed wetlands on industrial pollutant removal. Four parallel pilot-scale modified free water surface (FWS) constructed wetland systems [dimension for each system: 4-m (L)x1-m (W)x1-m (D)] were installed inside an industrial park for conducting the proposed treatability study. The averaged influent contains approximately 170 mg l(-1) chemical oxygen demand (COD), 80 mg l(-1) biochemical oxygen demand (BOD), 90 mg l(-1) suspend solid (SS), and 32 mg l(-1) NH(3)-N. In the plant-selection study, four different wetland plant species including floating plants [Pistia stratiotes L. (P. stratiotes) and Ipomoea aquatica (I. aquatica)] and emergent plants [Phragmites communis L. (P. communis) and Typha orientalis Presl. (T. orientalis)] were evaluated. Results show that only the emergent plant (P. communis) could survive and reproduce with a continuous feed of 0.4m(3)d(-1) of the raw wastewater. Thus, P. communis was used in the subsequent treatment study. Two different control parameters including hydraulic retention time (HRT) (3, 5, and 7d) and media [vesicles ceramic bioballs and small gravels, 1cm in diameter] were examined in the treatment study. Results indicate that the system with a 5-d HRT (feed rate of 0.4m(3)d(-1)) and vesicles ceramic bioballs as the media had the acceptable and optimal pollutant removal efficiency. If operated under conditions of the above parameters, the pilot-plant wetland system can achieve removal of 61% COD, 89% BOD, 81% SS, 35% TP, and 56% NH(3)-N. The treated wastewater meets the current industrial wastewater discharge standards in Taiwan.  相似文献   

19.
This study investigates the effect of dispersed microorganisms and exocellular polymeric substances on biomass dewaterability. Specific resistance to filtration (SRF) was measured for biomass from a membrane bioreactor and a completely mixed activated sludge system. Both laboratory-scale reactors were fed with synthetic wastewater and operated at a high food-to-microorganism ratio (F/M) (1 to 11 kilograms chemical oxygen demand per kilogram mixed liquor volatile suspended solids per day [kgCOD/(kg MLVSS.d)]) and short solids retention times (0.25 to 5 d). The SRF values were affected by strong interactions of three parameters: (1) the mixed liquor suspended solids concentration, (2) the amount of dispersed microorganisms, and (3) the exocellular polymeric substances (EPS) concentration. At F/M smaller than 2 kg COD/(kg MLSS.d) and mixed liquor suspended solids (MLSS) concentration higher than 2000 mg/L, increasing amount of dispersed microorganisms in the biomass yielded higher SRF values. However, at high F/M (> 5 kg COD/kg MLSS.d) and low MLSS concentrations (< 600 mg/L), lower EPS concentrations resulted in slightly smaller SRF values, even though the amount of dispersed microorganisms in the biomass was much higher. Thus, at low MLSS concentrations, EPS concentrations rather than the amount of dispersed microorganisms tend to control SRF.  相似文献   

20.
实际污水与模拟污水活性污泥系统的特性差异   总被引:2,自引:0,他引:2  
实验中经常采用人工配置的模拟生活污水,为了研究其与实际生活污水活性污泥系统的特性差异,采用2个序批式间歇反应器(SBR)进行平行实验(厌氧、好氧方式运行),系统地考察了在进水主要组分和运行参数相同的情况下,不同原水对活性污泥系统脱氮、除磷、比好氧速率、污泥絮体形态和出水水质等方面的影响。结果表明,模拟污水系统的硝化活性强于实际污水系统,两者的平均硝化速率分别为7.43 mg NH4+-N/(L.h)和5.55 mg NH4+-N/(L.h)。在前置厌氧段,模拟污水系统的释磷量比实际污水系统高出36.45%。两者在后续好氧阶段都能够充分吸磷。模拟污水系统的平均比好氧速率(SOUR)高达64.54 mg O2/(g MLSS.h),而实际污水系统的则只有32.81 mg O2/(g MLSS.h)。模拟污水系统的污泥絮体疏松,粒径小,形状不规则,沉降性差,沉后出水平均悬浮物浓度(SS)为20 mg/L;而实际污水系统的污泥絮体则密实、粒径大,沉降性好,沉后水十分清澈,SS几乎检测不出。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号