首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
Abstract

Nowadays, the heating, ventilation, and air conditioning (HVAC) system has been an important facility for maintaining indoor air quality. However, the primary function of typical HVAC systems is to control the temperature and humidity of the supply air. Most indoor air pollutants, such as volatile organic compounds (VOCs), cannot be removed by typical HVAC systems. Thus, some air handling units for removing VOCs should be added in typical HVAC systems. Among all of the air cleaning techniques used to remove indoor VOCs, photocatalytic oxidation is an attractive alternative technique for indoor air purification and deodorization. The objective of this research is to investigate the VOC removal efficiency of the photocatalytic filter in a HVAC system. Toluene and formaldehyde were chosen as the target pollutants. The experiments were conducted in a stainless steel chamber equipped with a simplified HVAC system. A mechanical filter coated with Degussa P25 titania photocatalyst and two commercial photocatalytic filters were used as the photo-catalytic filters in this simplified HVAC system. The total air change rates were controlled at 0.5, 0.75, 1, 1.25, and 1.5 hr?1, and the relative humidity (RH) was controlled at 30%, 50%, and 70%. The ultraviolet lamp used was a 4-W, ultraviolet-C (central wavelength at 254 nm) strip light bulb. The first-order decay constant of toluene and form-aldehyde found in this study ranged from 0.381 to 1.01 hr?1 under different total air change rates, from 0.34 to 0.433 hr?1 under different RH, and from 0.381 to 0.433 hr?1 for different photocatalytic filters.  相似文献   

2.
Jo WK  Park KH 《Chemosphere》2004,57(7):555-565
The current study evaluated the technical feasibility of applying TiO2 photocatalysis to the removal of low-ppb concentrations of volatile organic compounds (VOCs) commonly associated with non-occupational indoor air quality issues. A series of experiments was conducted to evaluate five parameters (relative humidity (RH), hydraulic diameter (HD), feeding type (FT) for VOCs, photocatalytic oxidation (PCO) reactor material (RM), and inlet port size (IPS) of PCO reactor) in relation to the PCO destruction efficiencies of the selected target VOCs. None of the target VOCs exhibited any significant dependence on the RH, which is inconsistent with a previous study where, under conditions of low humidity and a ppm toluene inlet level, a drop in the PCO efficiency was reported with a decreasing humidity. However, the other four parameters (HD, RM, FT, and IPS) were found to be important for better VOC removal efficiencies as regards the application of TiO2 photocatalytic technology for cleansing non-occupational indoor air. The PCO destruction of VOCs at concentrations associated with non-occupational indoor air quality issues was up to nearly 100%, and the CO generated during PCO was a negligible addition to indoor CO levels. Accordingly, a PCO reactor would appear to be an important tool in the effort to improve non-occupational indoor air quality.  相似文献   

3.
Abstract

Volatile organic compounds (VOCs) are a major concern for indoor air pollution because of the impacts on human health. In recent years, interest has increased in the development and design of activated carbon filters for removing VOCs from indoor air. Although extensive information is available on sources, concentrations, and types of indoor VOCs, there is little or no information on the performance of indoor air adsorption systems for removing low concentrations of primary VOCs. Filter designs need to consider various factors such as empty bed contact time, humidity effects, competitive adsorption, and feed concentration variations, whereas adsorption capacities of the indoor VOCs at the indoor concentration levels are important parameters for filter design. A preliminary assessment of the feasibility of using adsorption filters to remove low concentrations of primary VOCs can be performed. This work relates the information (including VOC classes in indoor air, the typical indoor concentrations, and the adsorption isotherms) with the design of a particular adsorbent/adsorbates system. As groundwork for filter design and development, this study selects the primary VOCs in indoor air of residences, schools, and offices in different geographical areas (North America, Europe, and Asia) on the basis of occurrence, concentrations, and health effects. Activated carbon fiber cloths (ACFCs) are chosen as the adsorbents of interest. It is demonstrated that the isotherm of a VOC (e.g., toluene on the ACFC) at typical indoor concentrations—parts per billion by volume (ppbv) level—is different than the isotherm at parts per million by volume (ppmv) levels reported in the publications. The isotherms at the typical indoor concentrations for the selected primary VOCs are estimated using the Dubinin–Radushkevitch equation. The maximum specific throughput for an indoor VOC removal system to remove benzene is calculated as a worst-case scenario. It is shown that VOC adsorption capacity is an important indicator of a filter’s lifetime and needs to be studied at the appropriate concentration range. Future work requires better understanding of the realistic VOC concentrations and isotherms in indoor environments to efficiently utilize adsorbents.  相似文献   

4.

Background, aim

The aims of the NORMACAT project are: to develop tools and unbiased standardized methods to measure the performance and to validate the safety of new materials and systems integrating photocatalysis, to develop new photocatalytic media with higher efficiency and to give recommendations aimed at improving the tested materials and systems.

Method

To achieve this objective, it was necessary to design standardized test benches and protocols to assess photocatalytic efficiency of materials or systems used in the treatment of volatile organic compounds (VOCs) and odour under conditions close to applications. The tests are based on the validation of robust analytical methods at the parts per billion by volume level that not only follow the disappearance of the initial VOCs but also identify the secondary species and calculate the mineralization rates.

Results

The first results of inter-laboratory closed chamber tests, according to XP B44-013 AFNOR standard, are described. The photocatalytic degradation of mixtures of several defined pollutants under controlled conditions (temperature, relative humidity, initial concentration) was carried out in two independent laboratories with the same photocatalytic device and with various analytical procedures. Comparison of the degradation rate and of the mineralization efficiency allowed the determination of the clean air delivery rate in both cases. Formaldehyde was the only by-product detected during photocatalytic test under standardized experimental conditions. The concentration of transient formaldehyde varied according to the initial VOC concentration. Moreover the photocatalytic reaction rate of formaldehyde in mixture with other pollutants was analysed. It was concluded that formaldehyde concentration did not increase with time.

Conclusion??perspective

This type of experiment should allow the comparison of the performances of different photoreactors and of photocatalytic media under controlled and reproducible conditions against mixtures of pollutants including formaldehyde.  相似文献   

5.
The emission of volatile organic compounds (VOC) from air filters of HVAC systems was to be evaluated. In a first study carbonyl compounds (14 aldehydes and two ketones) were measured by reacting them with 2,4-dinitrophenylhydrazine (DNPH). Analysis was done by HPLC and UV detection. In laboratory experiments pieces of used and unused HVAC filters were incubated in test chambers. Filters to be investigated were taken from a filter bank of a large HVAC system in the centre of Berlin. First results show that – among those compounds – formaldehyde and acetone were found in higher concentrations in the test chambers filled with used filters in comparison to those with unused filters. Parallel field measurements were carried out at the prefilter and main filter banks of the two HVAC systems. Here measurements were carried out simultaneously before and after the filters to investigate whether those aldehydes or ketones arise from the filter material on site. Formaldehyde and acetone significantly increased in concentration after the filters of one HVAC system. In parallel experiments microorganisms were proved to be able to survive on air filters. Therefore, a possible source of formaldehyde and acetone might be microbes.  相似文献   

6.
Indoor air quality (IAQ) in schools is a matter of concern because children are most vulnerable and sensitive to pollutant exposure. Conservation of energy at the expense of ventilation in heating, ventilation, and air conditioning (HVAC) systems adversely affects IAQ. Extensive use of new materials in building, fitting, and refurbishing emit various pollutants such that the indoor environment creates its own discomfort and health risks. Various schools in Kuwait were selected to assess their IAQ. Comprehensive measurements of volatile organic compounds (VOCs) consisting of 72 organic compounds consisting of aliphatic (C3–C6), aromatic (C6–C9), halogenated (C1–C7), and oxygenated (C2–C9) functional groups in indoor air were made for the first time in schools in Kuwait. The concentrations of indoor air pollutants revealed hot spots (science preparation rooms, science laboratories, arts and crafts classes/paint rooms, and woodworking shops/decoration rooms where local sources contributed to the buildup of pollutants in each school. The most abundant VOC pollutant was chlorodifluoromethane (R22; ClF2CH), which leaked from air conditioning (AC) systems due to improper operation and maintenance. The other copious VOCs were alcohols and acetone at different locations due to improper handling of the chemicals and their excessive uses as solvents. Indoor carbon dioxide (CO2) levels were measured, and these levels reflected the performance of HVAC systems; a specific rate or lack of ventilation affected the IAQ. Recommendations are proposed to mitigate the buildup of indoor air pollutants at school sites.

Implications: Indoor air quality in elementary schools has been a subject of extreme importance due to susceptibility and sensibility of children to air pollutants. The schools were selected based on their surrounding environment especially downwind direction from the highly industrialized zone in Kuwait. Extensive sampling from different sites in four schools for comprehensive VOCs and CO2 were completed for an extended period of over a year. Different hot spots were identified where leaked refrigerant and inadequate handling of laboratory solvents contributed to the high VOCs in the respective locations. CO2 levels reflected HVAC performance and poor ventilation. A list of recommendations has been proposed to eradicate these high levels of air pollution.  相似文献   


7.
以集中空调中处理室内可挥发性有机物(VOCs)为应用背景,搭建了试验台.实验研究了真空紫外灯(主波长254 nm,185 nm)降解甲醛的影响因素以及产生O3的情况.研究表明,在产生的O3浓度低于室内空气质量标准(0.16mg/m3)的情况下,真空紫外灯也能够高效地降解空气中低浓度甲醛(<1 mg/m3);甲醛降解率与反应器空气流速及甲醛初始浓度成反比;降解速率与甲醛初始浓度成正比,与反应器空气的流速成反比;绝对湿度对真空紫外灯降解甲醛有一定的影响;反应器空间大小对甲醛降解影响比较显著.应用于集中空调系统净化室内空气中VOCs,取得了很好的效果.  相似文献   

8.
This paper describes a laboratory project to assess the accuracy of emission and indoor air quality models to be used in predicting formaldehyde (HCHO) concentrations in residences due to pressed-wood products made with urea-formaldehyde bonding resins. The products tested were partlcleboard underlayment, hardwood- plywood paneling and medium-density fiberboard (mdf). The products were initially characterized in chambers by measuring their formaldehyde surface emission rates over a range of formaldehyde concentrations, air exchange rates and two combinations of temperature and relative humidity (23° C and 5 0% RH; 26°C and 60% RH). They were then installed in a two-room prototype house in three different combinations (underlayment flooring only; underlayment flooring and paneling; and underlayment flooring, paneling, and mdf). The equilibrium formaldehyde concentrations were monitored as a function of air exchange rate. Particleboard underlayment and mdf, but not paneling, behaved as the emission model predicted over a large concentration range, under both sets of temperature and relative humidity. Good agreement was also obtained between measured formaldehyde concentrations and those predicted by a mass-balance indoor air quality model.  相似文献   

9.
Shin SH  Jo WK 《Chemosphere》2012,89(5):569-578
The present study investigated the indoor concentrations of selected volatile organic compounds (VOCs) and formaldehyde and their indoor emission characteristics in newly-built apartments at the pre-occupancy stage. In total, 107 apartments were surveyed for indoor and outdoor VOC concentrations in two metropolitan cities and one rural area in Korea. A mass balanced model was used to estimate surface area-specific emission rates of individual VOCs and formaldehyde. Seven (benzene, ethyl benzene, toluene, m,p-xylene, o-xylene, n-hexane, and n-heptane) of 40 target compounds were detectable in all indoor air samples, whereas the first five were detected in all outdoor air samples. Formaldehyde was also predominant in the indoor air samples, with a high detection frequency of 96%. The indoor concentrations were significantly higher than the outdoor concentrations for aromatics, alcohols, terpenes, and ketones. However, six halogenated VOCs exhibited similar concentrations for indoor and outdoor air samples, suggesting that they are not major components emitted from building materials. It was also suggested that a certain portion of the apartments surveyed were constructed by not following the Korean Ministry of Environment guidelines for formaldehyde emissions. Toluene exhibited the highest emission rate with a median value of 138 μg m−2 h−1. The target compounds with median emission rates greater than 20 μg m−2 h−1 were toluene, 1-propanol, formaldehyde, and 2-butanone. The wood panels/vinyl floor coverings were the largest indoor pollutant source, followed by floorings, wall coverings, adhesives, and paints. The wood panels/vinyl floor coverings contributed nearly three times more to indoor VOC concentrations than paints.  相似文献   

10.
Salthammer T  Mentese S 《Chemosphere》2008,73(8):1351-1356
The level of carbonyl compounds in indoor air is crucial due to possible health effects and the high prevalence of their potential sources. Therefore, selecting a convenient and rapid analytical technique for the reliable detection of carbonyl compound concentrations is important. The acetyl acetone (acac) method is a widely used standard procedure for detecting gaseous formaldehyde. For measuring formaldehyde along with other carbonyl compounds, the DNPH-method is commonly applied. The recommended procedure for measuring volatile organic compounds (VOCs) is sampling on Tenax TA, followed by thermal desorption and GC/MS analysis. In this study, different analytical techniques for the quantification of formaldehyde, pentanal, and hexanal are critically compared. It was found that the acac- and DNPH-method are in very good agreement for formaldehyde. In contrast, the DNPH-method significantly underestimates indoor air concentrations of the higher aldehydes in comparison to sampling on Tenax TA, although both methods are strongly correlated. The reported results are part of the EURIMA-WKI study on levels of indoor air pollutants resulting from construction, building materials and interior decoration.  相似文献   

11.
Volatile organic compounds (VOCs) are prevalent components of indoor air pollution. Among the approaches to remove VOCs from indoor air, photocatalytic oxidation (PCO) is regarded as a promising method. This paper is a review of the status of research on PCO purification of VOCs in indoor air. The review and discussion concentrate on the preparation and coating of various photocatalytic catalysts; different kinetic experiments and models; novel methods for measuring kinetic parameters; reaction pathways; intermediates generated by PCO; and an overview of various PCO reactors and their models described in the literature. Some recommendations are made for future work to evaluate the performance of photocatalytic catalysts, to reduce the generation of harmful intermediates and to design new PCO reactors with integrated UV source and reaction surface.  相似文献   

12.
The partition and effective diffusion coefficients of formaldehyde were measured for three materials (conventional gypsum wallboard, “green” gypsum wallboard, and “green” carpet) under three relative humidity (RH) conditions (20%, 50%, and 70% RH). The “green” materials contained recycled materials and were friendly to environment. A dynamic dual-chamber test method was used. Results showed that a higher relative humidity led to a larger effective diffusion coefficient for two kinds of wallboards and carpet. The carpet was also found to be very permeable resulting in an effective diffusion coefficient at the same order of magnitude with the formaldehyde diffusion coefficient in air. The partition coefficient (K ma) of formaldehyde in conventional wallboard was 1.52 times larger at 50% RH than at 20% RH, whereas it decreased slightly from 50% to 70% RH, presumably due to the combined effects of water solubility of formaldehyde and micro-pore blocking by condensed moisture at the high RH level. The partition coefficient of formaldehyde increased slightly with the increase of relative humidity in “green” wallboard and “green” carpet. At the same relative humidity level, the “green” wallboard had larger partition coefficient and effective diffusion coefficient than the conventional wallboard, presumably due to the micro-pore structure differences between the two materials. The data generated could be used to assess the sorption effects of formaldehyde on building materials and to evaluate its impact on the formaldehyde concentration in buildings.

Implications: Based on the results of this study, the sink effects of these commonly used materials (conventional and “green” gypsum wallboards, “green” carpet) on indoor formaldehyde concentration could be estimated. The effects of relative humidity on the diffusion and partition coefficients of formaldehyde were found to differ for materials and for different humidity levels, indicating the need for further investigation of the mechanisms through which humidity effects take place.  相似文献   

13.

Indoor air pollutants comprise both polar and non-polar volatile organic compounds (VOCs). Indoor potted plants are well known for their innate ability to improve indoor air quality (IAQ) by detoxification of indoor air pollutants. In this study, a combination of two different plant species comprising a C3 plant (Zamioculcas zamiifolia) and a crassulacean acid metabolism (CAM) plant (Sansevieria trifasciata) was used to remove polar and non-polar VOCs and minimize CO2 emission from the chamber. Z. zamiifolia and S. trifasciata, when combined, were able to remove more than 95% of pollutants within 48 h and could do so for six consecutive pollutant’s exposure cycles. The CO2 concentration was reduced from 410 down to 160 ppm inside the chamber. Our results showed that using plant growth medium rather than soil had a positive effect on decreasing CO2. We also re-affirmed the role of formaldehyde dehydrogenase in the detoxification and metabolism of formaldehyde and that exposure of plants to pollutants enhances the activity of this enzyme in the shoots of both Z. zamiifolia and S. trifasciata. Overall, a mixed plant of Z. zamiifolia and S. trifasciata was more efficient at removing mixed pollutants and reducing CO2 than individual plants.

  相似文献   

14.
Subway systems are considered as main public transportation facility in developed countries. Time spent by people in indoors, such as underground spaces, subway stations, and indoor buildings, has gradually increased in the recent past. Especially, operators or old persons who stay in indoor environments more than 15 hr per day usually influenced a greater extent by indoor air pollutants. Hence, regulations on indoor air pollutants are needed to ensure good health of people. Therefore, in this study, a new cumulative calculation method for the estimation of total amounts of indoor air pollutants emitted inside the subway station is proposed by taking cumulative amounts of indoor air pollutants based on integration concept. Minimum concentration of individual air pollutants which naturally exist in indoor space is referred as base concentration of air pollutants and can be found from the data collected. After subtracting the value of base concentration from data point of each data set of indoor air pollutant, the primary quantity of emitted air pollutant is calculated. After integration is carried out with these values, adding the base concentration to the integration quantity gives the total amount of indoor air pollutant emitted. Moreover the values of new index for cumulative indoor air quality obtained for 1 day are calculated using the values of cumulative air quality index (CAI). Cumulative comprehensive indoor air quality index (CCIAI) is also proposed to compare the values of cumulative concentrations of indoor air pollutants. From the results, it is clear that the cumulative assessment approach of indoor air quality (IAQ) is useful for monitoring the values of total amounts of indoor air pollutants emitted, in case of exposure to indoor air pollutants for a long time. Also, the values of CCIAI are influenced more by the values of concentration of NO2, which is released due to the use of air conditioners and combustion of the fuel. The results obtained in this study confirm that the proposed method can be applied to monitor total amounts of indoor air pollutants emitted, inside apartments and hospitals as well. Implications: Nowadays, subway systems are considered as main public transportation facility in developed countries. Time spent by people in indoors, such as underground spaces, subway stations, and indoor buildings, has gradually increased in the recent past. Especially, operators or old persons who stay in the indoor environments more than 15 hr per day usually influenced a greater extent by indoor air pollutants. Hence, regulations on indoor air pollutants are needed to ensure good health of people. Therefore, this paper presents a new methodology for monitoring and assessing total amounts of indoor air pollutants emitted inside underground spaces and subway stations. A new methodology for the calculation of cumulative amounts of indoor air pollutants based on integration concept is proposed. The results suggest that the cumulative assessment approach of IAQ is useful for monitoring the values of total amounts of indoor air pollutants, if indoor air pollutants accumulated for a long time, especially NO2 pollutants. The results obtained here confirm that the proposed method can be applied to monitor total amounts of indoor air pollutants emitted, inside apartments and hospitals as well.  相似文献   

15.
Nowadays, a large proportion of photocatalytic oxidation (PCO) devices are being implemented in heating, ventilation and air-conditioning systems. However, no systematic studies have been carried out regarding the influence of inlet air preconditioning. To analyse the impact of the inlet air-conditions into photocatalytic efficiency, a simulated air-conditioning duct with flowing gas through inside was designed. Isobutylene was chosen as the target VOCs. The concentration in the gas phase was monitored using a photoionization detector. The influence of flow rate, relative humidity and temperature on the VOC removal efficiency was analysed. Experimental results were presented in terms of gas-removal efficiency (η) and clean air delivery rate (CADR) and analysed on a kinetic basis. From them, the weight of each parameter in the global process has been determined, from bigger to smaller contribution, flow>>temperature>relative humidity. Also, the relevance of the inlet air conditions has been illustrated in a model room in order to determinate the time necessary to obtain a threshold value accomplishing with enough air quality and the energy consumption of the device. Additionally, the photocatalytic decontamination has been assimilated to the “air exchange rate”, a parameter commonly used in indoor air quality studies. The results show that preconditioning of air can improve the efficiency of photocatalytic devices and bring important energy savings.  相似文献   

16.
光催化降解模拟室内挥发性有机污染物研究   总被引:4,自引:1,他引:3  
用浸渍-提拉法制备玻璃弹簧负载型TiO2薄膜催化剂,在自制的反应器中进行光催化降解由丙酮、甲苯、对二甲苯组成的模拟室内挥发性有机污染物VOCs研究.研究发现:催化剂中掺杂金属离子能影响催化剂的降解效果,降解效果依次为掺铈TiO2>纯TiO2>掺银TiO2;气体流量显著影响降解效果,丙酮、甲苯和对二甲苯的最佳降解流量分别为3、5、7 L/min;混合气体中非对称性的极性分子的降解效率高于对称性分子,导致丙酮、对二甲苯组分降解率降低,甲苯降解率增高.  相似文献   

17.
Subway systems are considered as main public transportation facility in developed countries. Time spent by people in indoors, such as underground spaces, subway stations, and indoor buildings, has gradually increased in the recent past. Especially, operators or old persons who stay in indoor environments more than 15 hr per day usually influenced a greater extent by indoor air pollutants. Hence, regulations on indoor air pollutants are needed to ensure good health of people. Therefore, in this study, a new cumulative calculation method for the estimation of total amounts of indoor air pollutants emitted inside the subway station is proposed by taking cumulative amounts of indoor air pollutants based on integration concept. Minimum concentration of individual air pollutants which naturally exist in indoor space is referred as base concentration of air pollutants and can be found from the data collected. After subtracting the value of base concentration from data point of each data set of indoor air pollutant, the primary quantity of emitted air pollutant is calculated. After integration is carried out with these values, adding the base concentration to the integration quantity gives the total amount of indoor air pollutant emitted. Moreover, the values of new index for cumulative indoor air quality obtained for 1 day are calculated using the values of cumulative air quality index (CAI). Cumulative comprehensive indoor air quality index (CCIAI) is also proposed to compare the values of cumulative concentrations of indoor air pollutants. From the results, it is clear that the cumulative assessment approach of indoor air quality (IAQ) is useful for monitoring the values of total amounts of indoor air pollutants emitted, in case of exposure to indoor air pollutants for a long time. Also, the values of CCIAI are influenced more by the values of concentration of NO2, which is released due to the use of air conditioners and combustion of the fuel. The results obtained in this study confirm that the proposed method can be applied to monitor total amounts of indoor air pollutants emitted, inside apartments and hospitals as well.

Implications: Nowadays, subway systems are considered as main public transportation facility in developed countries. Time spent by people in indoors, such as underground spaces, subway stations, and indoor buildings, has gradually increased in the recent past. Especially, operators or old persons who stay in the indoor environments more than 15 hr per day usually influenced a greater extent by indoor air pollutants. Hence, regulations on indoor air pollutants are needed to ensure good health of people. Therefore, this paper presents a new methodology for monitoring and assessing total amounts of indoor air pollutants emitted inside underground spaces and subway stations. A new methodology for the calculation of cumulative amounts of indoor air pollutants based on integration concept is proposed. The results suggest that the cumulative assessment approach of IAQ is useful for monitoring the values of total amounts of indoor air pollutants, if indoor air pollutants accumulated for a long time, especially NO2 pollutants. The results obtained here confirm that the proposed method can be applied to monitor total amounts of indoor air pollutants emitted, inside apartments and hospitals as well.  相似文献   

18.
自行设计了气固相光催化实验系统,以铝材为担载体,TCM和TCE为模拟污染物,在常温、常压下,对辐射光源、气体相对湿度、污染物反应浓度等因素对TCM和TCE的光催化降解反应的影响进行了研究.结果表明,在研究所采用的实验条件下,辐射光源采用254 nm时的降解效率要比采用365 nm时高10%左右;气体相对湿度为40%时光催化降解效率最高;随着污染物反应浓度的增加,TCM的降解效率降低,而TCE的降解效率增加.初步的反应动力学研究结果表明,TCM和TCE在二氧化钛表面的光催化降解反应可采用Langmuir-Hinshelwood动力学方程来表征.  相似文献   

19.
Abstract

Submicron particles play a major role in soiling processes and contribute to corrosion, current leakage and shorts in electronic equipment. For more than a year, optical particle counters have been used to continuously measure the concentrations of submicron particles at a telecommunications facility in Southern California. Separate instruments have simultaneously sampled at four locations: the outdoor air intake, immediately upstream of the HVAC filters, immediately downstream of the HVAC filters, and inside the office. The indoor concentrations can be explained in the context of a one-compartment mass balance model. Key parameters in the model (e.g., the air exchange rate) were monitored throughout the sampling period. In the latter part of this study, the particle counters were used as feedback elements in the HVAC system. An estimate of the concentration of indoor submicron particles, based on measurements of outdoor submicron particles, has been used as a control variable. When this variable exceeds a preset value, the outdoor air damper is partially closed, reducing the amount of outdoor air entering the building. That is, the position of the damper is based on the concentration of outdoor particles as well as the outdoor temperature. As a consequence, the average indoor concentration of submicron particles has been significantly reduced within this facility.  相似文献   

20.
Wan-Kuen Jo  Chang-Hee Yang   《Chemosphere》2009,77(2):236-241
Unlike previous photocatalytic oxidation (PCO) studies incorporated with adsorption, this study investigates the feasibility of applying a tandem PCO-adsorption hybrid technique regarding low-level monoaromatic compound removal. The PCO efficiencies decreased as the hydraulic diameter (HD) increased. A PCO reactor of a medium HD size was selected for further experiments. Under conditions relevant to the use of the PCO system, the CO level measured during the PCO process was minimal in comparison to indoor CO levels. Trace level formations of formaldehyde and acetaldehyde were observed during the photocatalytic process, but these compounds were undetectable at the activated carbon unit outlet. The degradation efficiencies, obtained from the PCO unit, exhibited a dependence on both the inlet concentration (IC) and relative humidity (RH), whereas those from the PCO-adsorption hybrid system did not. Under specific conditions, the PCO unit presented a high degradation efficiency of close to, or exceeding 90%, in regards to ethyl benzene, o-xylene, and m,p-xylene. However, the benzene air concentrations, after being treated by the PCO unit, substantially exceeded the USEPA inhalation reference concentration guideline of 30 μg m−3 (corresponding to 0.01 ppm). In contrast, the PCO-adsorption hybrid system presented a high removal efficiency of close to 100% regarding all compounds, regardless of the IC or RH range. Consequently, it is suggested that the PCO-adsorption hybrid system has a synergistic advantage of photocatalysis and adsorption in regards to the BTEX elimination process.  相似文献   