首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
ABSTRACT

Particulate matter (PM) is a ubiquitous air pollutant that has been receiving increasing attention in recent years due in part to the association between PM and a number of adverse health outcomes, including mortality and increases in emergency room visits and respiratory symptoms, as well as exacerbation of asthma and decrements in lung function.1-5 As a result, the ability to accurately sample ambient PM has become important, both to researchers and to regulatory agencies. The federal reference method for the determination of fine PM as PM2.5 in the atmosphere recommends that particle-sampling filters be conditioned and weighed in an environment with constant temperature and relative humidity (RH).6 It is also recommended that vibration, electrostatic charges, and contamination of the filters from laboratory air be minimized to reduce variability in filter weight measurements. These controls have typically been maintained in small, environmentally controlled “cleanrooms.” As an alternative to constructing an elaborate cleanroom, we have designed, and presented in this paper, an inexpensive weighing chamber to maintain the necessary level of humidity control.  相似文献   

2.
INTENTION, GOAL, SCOPE, BACKGROUND: As the strong negative health effect of exposure to the inhalable particulate matter PM10 in the urban environment has been confirmed, the study of the mass concentrations, physico-chemical characteristics, sources, as well as spatial and temporal variation of atmospheric aerosol particles becomes very important. OBJECTIVE: This work is a pilot study to assess the concentration level of ambient suspended particulate matter, with an aerodynamic diameter of less than 10 microm, in the Belgrade central urban area. Average daily concentrations of PM10 and PM2.5 have been measured at three representative points in the city between June 2002 and December 2002. The influence of meteorological parameters on PM10 and PM2.5 concentrations was analyzed, and possible pollution sources were identified. METHODS: Suspended particles were collected on Pure Teflon filters by using a Mini-Vol low-volume air sampler (Airmetrics Co., Inc.; 5 l min(-1) flow rate). Particle mass was determined gravimetrically after 48 h of conditioning in a desiccator, in a Class 100 clean room at the temperature T = 20 degrees C and at about 50% constant relative humidity (RH). RESULTS AND DISCUSSION: Analysis of the PM10 data indicated a marked difference between season without heating--(summer; mean value 56 microg m(-3)) and heating season--(winter; mean value 96 microg m3); 62% of samples exceeded the level of 50 microg m(-3). The impact of meteorological factors on PM concentrations was not immediately apparent, but there was a significant negative correlation with the wind speed. CONCLUSIONS: The PM10 and PM2.5 mass concentrations in the Belgrade urban area had high average values (77 microg m(-3) and 61 microg m(-3)) in comparison with other European cities. The main sources of particulate matter were traffic emission, road dust resuspension, and individual heating emissions. When the air masses are coming from the SW direction, the contribution from the Obrenovac power plants is evident. During days of exceptionally severe pollution, in both summer and winter periods, high production of secondary aerosols occurred, as can be seen from an increase in PM2.5 in respect to PM10 mass concentration. RECOMMENDATION AND OUTLOOK: The results obtained gave us the first impression of the concentration level of particulate matter, with an aerodynamic diameter of less than 10 microm, in the Belgrade ambient air. Due to measured high PM mass concentrations, it is obvious that it would be very difficult to meet the EU standards (EEC 1999) by 2010. It is necessary to continue with PM10 and PM2.5 sampling; and after comprehensive analysis which includes the results of chemical and physical characterization of particles, we will be able to recommend effective control measures in order to improve air quality in Belgrade.  相似文献   

3.
As part of an international research project, aerosol samples were collected by several filter-based devices on Nuclepore polycarbonate membrane, Teflon membrane and quartz fibre filters over separate daylight periods and nights, and on-line aerosol measurements were performed by TEOM and aethalometer within an urban canyon (kerbside) and at a near-city background site in Budapest, Hungary from 23 April–5 May 2002. Aerosol masses in PM2.0, PM10–2.0, PM2.5, PM10 size fractions and of TSP were determined gravimetrically; atmospheric concentrations of organic (OC) and elemental carbon (EC) for PM2.5 (or PM2.0), PM10 fractions and for TSP were measured by thermal–optical transmission method. Repeatability of the mass determination by Nuclepore filters seems to be 5–6%. Collections on Teflon filters yielded smaller mass on average by 8(±12)% than that for the Nuclepore filters. Quartz filters overestimated the PM10 mass in comparison with the Nuclepore filters due primarily to sampling artefacts on average by 10(±16)% at the kerbside. Tandem filter set-ups were utilised for correcting the sampling artefacts for OC by subtraction method. At the kerbside, the aerosol mass was made up on average of 35(±4)% of organic matter (OM) in the PM10 fraction, while the contribution of OM to the PM2.5 mass was 43(±9)%. At the background, OM also accounted for 43(±13)% of the PM2.0 mass. On average, EC made up 14(±6)%, 7(±2)% and 4.5(±1.1)% of the mass in the PM2.5, PM10 fractions and TSP, respectively, at the kerbside; while its contribution was only 2.1(±0.5)% in the PM2.0 fraction in the near-city background. Temporal variability for PM mass, OC and EC concentrations was related to road traffic, local meteorology and long-range transport of air masses. It was concluded that a direct coupling between the atmospheric concentration levels and vehicle circulation can be identified within the urban canyon, nevertheless, the local meteorology in particular and long-range transport of air masses have much more influence on the air quality than changes in the source intensity of road traffic. Concentration ratios of OC/EC were evaluated, and the amount of secondary organic aerosol (SOA) was estimated by using EC as tracer for the primary OC emissions. Mean contribution and standard deviation of the SOA to the OM in the PM2.5 size fraction at the kerbside over daylight periods and nights were of 37(±18) and 46(±16)%, respectively.  相似文献   

4.
Previous workers have shown that selenium is only partially trapped on a filter during air sampling. In some cases, these losses have been attributed to volatilization of selenium dioxide. Our results demonstrate that selenium dioxide, in the presence of moist air, is completely recovered (apparently as selenious acid aerosols) and that the previous shortfalls must be due to other selenium species as yet unidentified. Selenious acid aerosols in our study were formed by volatilizing selenium dioxide (approximately 3 mg) into a stream of moist ambient air (relative humidity, greater than 50%), and trapped on glass fiber filters using a high-volume air sampler. Selenium(IV) was ultrasonically extracted from the filter with water and analyzed by atomic absorption spectrometry. Selenious acid aerosols were trapped on the filters with high efficiency (105 +/- 5 percent) using a 50 minute sampling period. With an extended sampling period (24 hours) the recovery was 103 +/- 6 percent.  相似文献   

5.
Urban woodlands: their role in reducing the effects of particulate pollution   总被引:41,自引:0,他引:41  
In recent years a substantial research effort has focused on the links between particulate air pollution and poor health. As a result the PM10 value has been set as a measure of such pollutants which can directly cause illness. Due to their large leaf areas relative to the ground on which they stand and the physical properties of their surfaces, trees can act as biological filters, removing large numbers of airborne particles and hence improving the quality of air in polluted environments. The role of vegetation and urban woodlands in reducing the effects of particulate pollution is reviewed here. The improvement of urban air quality achieved by establishing more trees in towns and cities is also illustrated.  相似文献   

6.
Previous workers have shown that selenium is only partially trapped on a filter during air sampling. In some cases, these losses have been attributed to volatilization of selenium dioxide. Our results demonstrate that selenium dioxide, In the presence of moist air, is completely recovered (apparently as selenious acid aerosols) and that the previous shortfalls must be due to other selenium species as yet unidentified. Selenious acid aerosols In our study were formed by volatilizing selenium dioxide (≈3 mg) Into a stream of moist ambient air (relative humidity, >50%), and trapped on glass fiber filters using a high-volume air sampler. Selenium(IV) was ultrasonlcally extracted from the filter with water and analyzed by atomic absorption spectrometry. Selenious acid aerosols were trapped on the filters with high efficiency (105 ± 5 percent) using a 50 minute sampling period. With an extended sampling period (24 hours) the recovery was 103 ± 6 percent.  相似文献   

7.
The performance of Teflon-coated glass fiber filter media (Pallflex Emfab TX40) is evaluated for particulate matter (PM) sampling of residential wood heating devices in a dilution tunnel. Thirty samples of varying duration and PM loading and concentration were collected from an U.S. Environmental Protection Agency (EPA) Method 28 dilution tunnel using dual Method 5G sample trains with untreated glass fiber and Emfab filters. Filters were weighed soon after the end of sampling and again the next day after equilibration at 35% relative humidity (RH). PM concentrations from both types of filters agreed very well with 1-day equilibration, demonstrating that Emfab filters are appropriate for use in measuring PM from residential wood burning appliances in a dilution tunnel and have performance equal to or better than the glass fiber filter media. Agreement between filter media without equilibration was erratic, with PM from glass fiber filter samples varying from slightly less than the Emfab samples to as much as 2.8 times higher. Some of the glass fiber filters lost substantial mass with equilibration, with the highest percent loss at lower filter mass loadings. Mass loss for Emfab samples was a small percentage of the mass and very consistent across the range of mass loadings. Taken together, these results may indicate water uptake on the glass fiber media that is readily removed with 1-day equilibration at moderate RH conditions.

Implications: EPA regulations now allow the use of either glass fiber or Teflon filter media for wood appliance PM emission testing. Teflon filter media minimizes the potential for acid-gas PM artifacts on glass fiber filters; this is important as EPA moves toward the use of locally sourced cordwood for testing that may have higher sulfur content. This work demonstrates that the use of Teflon-coated glass fiber filters can give similar PM measurement results to glass fiber filters after 1 day of equilibration. With no equilibration, measured PM from glass fiber filters was usually higher than from Teflon-coated glass fiber filters.  相似文献   


8.
Abstract

Nowadays, the heating, ventilation, and air conditioning (HVAC) system has been an important facility for maintaining indoor air quality. However, the primary function of typical HVAC systems is to control the temperature and humidity of the supply air. Most indoor air pollutants, such as volatile organic compounds (VOCs), cannot be removed by typical HVAC systems. Thus, some air handling units for removing VOCs should be added in typical HVAC systems. Among all of the air cleaning techniques used to remove indoor VOCs, photocatalytic oxidation is an attractive alternative technique for indoor air purification and deodorization. The objective of this research is to investigate the VOC removal efficiency of the photocatalytic filter in a HVAC system. Toluene and formaldehyde were chosen as the target pollutants. The experiments were conducted in a stainless steel chamber equipped with a simplified HVAC system. A mechanical filter coated with Degussa P25 titania photocatalyst and two commercial photocatalytic filters were used as the photo-catalytic filters in this simplified HVAC system. The total air change rates were controlled at 0.5, 0.75, 1, 1.25, and 1.5 hr?1, and the relative humidity (RH) was controlled at 30%, 50%, and 70%. The ultraviolet lamp used was a 4-W, ultraviolet-C (central wavelength at 254 nm) strip light bulb. The first-order decay constant of toluene and form-aldehyde found in this study ranged from 0.381 to 1.01 hr?1 under different total air change rates, from 0.34 to 0.433 hr?1 under different RH, and from 0.381 to 0.433 hr?1 for different photocatalytic filters.  相似文献   

9.
Nowadays, the heating, ventilation, and air conditioning (HVAC) system has been an important facility for maintaining indoor air quality. However, the primary function of typical HVAC systems is to control the temperature and humidity of the supply air. Most indoor air pollutants, such as volatile organic compounds (VOCs), cannot be removed by typical HVAC systems. Thus, some air handling units for removing VOCs should be added in typical HVAC systems. Among all of the air cleaning techniques used to remove indoor VOCs, photocatalytic oxidation is an attractive alternative technique for indoor air purification and deodorization. The objective of this research is to investigate the VOC removal efficiency of the photocatalytic filter in a HVAC system. Toluene and formaldehyde were chosen as the target pollutants. The experiments were conducted in a stainless steel chamber equipped with a simplified HVAC system. A mechanical filter coated with Degussa P25 titania photocatalyst and two commercial photocatalytic filters were used as the photocatalytic filters in this simplified HVAC system. The total air change rates were controlled at 0.5, 0.75, 1, 1.25, and 1.5 hr(-1), and the relative humidity (RH) was controlled at 30%, 50%, and 70%. The ultraviolet lamp used was a 4-W, ultraviolet-C (central wavelength at 254 nm) strip light bulb. The first-order decay constant of toluene and formaldehyde found in this study ranged from 0.381 to 1.01 hr(-1) under different total air change rates, from 0.34 to 0.433 hr(-1) under different RH, and from 0.381 to 0.433 hr(-1) for different photocatalytic filters.  相似文献   

10.
The U.S. Environmental Protection Agency (EPA) Quality Assurance (QA) Guidance Document 2.12: Monitoring PM2.5 in Ambient Air Using Designated Reference or Class I Equivalent Methods (Document 2.12) requires conditioning of PM2.5 filters at 20-23 degrees C and 30-40% relative humidity (RH) for 24 hr prior to gravimetric analysis. Variability of temperature and humidity may not exceed +/-2 degrees C and +/-5% RH during the conditioning period. The quality assurance team at EPA Region 2's regional laboratory designed a PM2.5 weighing facility that operates well within these strict performance requirements. The traditional approach to meeting the performance requirements of Document 2.12 for PM2.5 filter analysis is to build a walk-in room, with costs typically exceeding $100,000. The initial one-time capital cost for the laboratory at EPA's Edison, NJ, facility was approximately $24,000. Annual costs [e.g., National Institute of Standards and Technology (NIST) recertifications and nitrogen replacement cylinders used for humidity control] are approximately $500. The average 24-hr variabilities in temperature and RH in the Region 2 weighing chamber are small, +/-0.2 degrees C and +/-0.8% RH, respectively. The mass detection limit for the PM2.5 weighing system of 47-mm stretched Teflon (lab blank) filters is 6.3 microg. This facility demonstrates an effective and economical example for states and other organizations planning PM2.5 weighing facilities.  相似文献   

11.
The effect of ambient relative humidity (RH) on hourly particulate matter (PM10) readings of beta-gauge monitors has been studied using two collocated monitors in the field. The inlet air of monitor 1 was conditioned with water vapor to increase its RH, whereas monitor 2 operated normally in ambient conditions. Experimental data showed that PM10 readings of monitor 1 were nearly the same as monitor 2, as long as the RH of its conditioned incoming air did not exceed approximately 80-85%. However, when the RH exceeded approximately 80-85%, PM10 readings of monitor 1 became higher than monitor 2, and the difference increased with increasing RH. The measurement of pressure drop across the filter was also conducted, and the data revealed that the increase of pressure drop per unit of PM10 concentration decreased when RH was higher than approximately 80-85%, as compared with the case when RH was lower than 80-85%. This is perhaps because of more porous structure of deposited particles in the beta-gauge monitor when RH is greater than approximately 80-85%. The theoretical calculation using an evaporation model and a thermodynamic model has been conducted to simulate the beta-gauge readings. The results show that the theoretical PM10 concentrations using the evaporation model are in better agreement with the actual beta-gauge readings than those using the thermodynamic equilibrium model.  相似文献   

12.
Particulate matter (PM) has long been recognized as an air pollutant due to its adverse health and environmental impacts. As emission of PM from agricultural operations is an emerging air quality issue, the Agricultural Particulate Matter Emissions Indicator (APMEI) has been developed to estimate the primary PM contribution to the atmosphere from agricultural operations on Census years and to assess the impact of practices adopted to mitigate these emissions at the soil landscape polygon scale as part of the agri-environmental indicator report series produced by Agriculture and Agri-Food Canada. In the APMEI, PM emissions from animal feeding operations, wind erosion, land preparation, crop harvest, fertilizer and chemical application, grain handling, and pollen were calculated and compared for the Census years of 1981-2006. In this study, we present the results for PM10 and PM2.5, which exclude chemical application and pollen sources as they only contribute to total suspended particles. In 2006, PM emissions from agricultural operations were estimated to be 652.6 kt for PM10 and 158.1 kt for PM2.5. PM emissions from wind erosion and land preparation account for most of PM emissions from agricultural operations in Canada, contributing 82% of PM10 and 76% of PM2.5 in 2006. Results from the APMEI show a strong reduction in PM emissions from agricultural operations between 1981 and 2006, with a decrease of 40% (442.8 kt) for PM10 and 47% (137.7 kt) for PM2.5. This emission reduction is mainly attributed to the adoption of conservation tillage and no-till practices and the reduction in the area of summer fallow land.  相似文献   

13.
Concentrations of Pb, Cd, As and Ni in PM(2.5) particles were measured in samples collected, using low volume PM(2.5) samplers (Harvard Impactor system, HI) at two sites in Athens basin; Patission Street in Athens city center and Rentis, a semi-urban and industrial area, during March 1995-March 1996. Sample analysis for Pb, Cd, Ni and As was accomplished by electrothermal atomic absorption spectrometry after total digestion. Annual geometric mean values in 183 PM(2.5) particles samples were found to be: Pb: 143 nanogram(-3); Cd: 0.34 nanogram(-3); Ni: 4.55 nanogram(-3); As: 0.79 nanogram(-3). The geographical and temporal distribution patterns were investigated. Pb exhibited higher values during the winter period. For the other elements no significant seasonal variation was observed. Wind direction, air temperature and relative humidity affected element concentrations. Principal component analysis was applied on the data to enable source apportionment of toxic elements in PM(2.5) particles. It was found that Pb, As and Ni have common sources, which could be vehicles emissions/oil combustion and resuspended road dust. Cd and a portion of As originate from industrial activities.  相似文献   

14.
Improving urban air quality in China: Beijing case study   总被引:14,自引:0,他引:14  
China is undergoing rapid urbanization because of unprecedented economic growth. As a result, many cities suffer from air pollution. Two-thirds of China's cities have not attained the ambient air quality standards applicable to urban residential areas (Grade II). Particulate matter (PM), rather than sulfur dioxide (SO2), is the major pollutant reflecting the shift from coal burning to mixed source pollution. In 2002, 63.2 and 22.4% of the monitored cities have PM and SO2 concentrations exceeding the Grade II standard, respectively. Nitrogen oxides (NOx) concentration kept a relatively stable level near the Grade II standard in the last decade and had an increasing potential in recent years because of the rapid motorization. In general, the air pollutants emission did not increase as quickly as the economic growth and energy consumption, and air quality in Chinese cities has improved to some extent. Beijing, a typical representative of rapidly developing cities, is an example to illustrate the possible options for urban air pollution control. Beijing's case provides hope that the challenges associated with improving air quality can be met during a period of explosive development and motorization.  相似文献   

15.
西安是空气污染监控和防治有代表性的西部大型城市。研究了西安市及周边地区上空气溶胶光学厚度与PM10浓度的关系模型。利用2011—2012年MODIS卫星气溶胶光学厚度(AOD)遥感产品,通过数据匹配,利用地面气象观测站点的能见度数据和相对湿度数据对AOD产品进行垂直标高订正和湿度订正,2项订正显著提高了AOD和地面PM10浓度的相关性,相关系数从0.36提高到0.65,按季节分类统计和订正春至冬四季的相关系数分别为0.57、0.71、0.62和0.87,夏季和冬季的订正更为有效,可用性更高,这可能由于受到不同季节气溶胶来源和特征的影响。为研究中国西部大型城市,特别是西安市空气环境监测和区域联防联控提供了一种有效方法。  相似文献   

16.
Concentrations of particulate matter (PM) and carbonaceous particulates in indoor and outdoor air at roadside private households were measured in Osaka, Japan. The particulate samples were collected on filters using a portable AND sampler capable of separating particles into three different size ranges: over 10 microm, 2-10 microm (coarse) and below 2 microm (fine) in aerodynamic diameter. The filters were weighed and then analyzed for elemental carbon (EC) and organic carbon (OC) by thermal oxidation using a CHN CORDER. The results showed that indoor fine PM concentration is considerably affected by fine EC and the fine EC in indoor air is significantly correlated to that in outdoor air, r=0.86 (n=30, p<0.001). A simple estimation from EC content ratio in diesel exhaust particles indicated that about 30% of indoor particulates of less than 10 microm (PM10) were contributed from diesel exhaust. Additionally, the size characteristics of outdoor PM at roadside and background sites were examined using Andersen Cascade Impactors.  相似文献   

17.
A wide range of environmental particulate matter (PM) both indoor and outdoor and consisting of natural and anthropogenic PM was collected by high volume air filters, electrostatic precipitation, and thermophoretic precipitation directly onto transmission electron microscope (TEM) coated grid platforms. These collected PM have been systematically characterized by TEM, energy-dispersive X-ray spectrometry (EDS) and scanning electron microscopy (SEM). In the El Paso, TX, USA/Juarez, Mexico metroplex 93% of outdoor PM1 is crystalline while 40% of PM1 is carbonaceous soot (including multiwall carbon nanotubes (MWCNTs) and multiconcentric fullerenes) PM. Multiply-replicated cytotoxicity (in vitro) assays utilizing a human epithelial (lung model) cell line (A549) consistently demonstrated varying degrees of cell death for essentially all PM which was characterized as aggregates of nanoparticulates or primary nanoparticles. Cytokine release was detected for Fe2O3, chrysotile asbestos, BC, and MWCNT PM while reactive oxygen species (ROS) production has been detected for Fe2O3, asbestos, BC, and MWCNT aggregate PM as well as natural gas combustion PM.Nanoparticulate materials in the indoor and outdoor environments appear to be variously cytotoxic, especially carbonaceous nano-PM such as multiwall carbon nanotubes, black carbon, and soot nano-PM produced by natural gas combustion.  相似文献   

18.
During collection on filter-based aerosol samplers, organic and inorganic aerosol compounds both contribute to positive and negative artefacts, significantly affecting chemical analyses results for single species and PM mass concentrations. Up to now, studies on organic or inorganic artefacts have been conducted in Europe but very scarce data are available for both in a single study.The field study was carried out in Milan, which is located in the Po valley (Northern Italy) one of the major pollution hot spots in Europe. As sampling artefacts depend on many factors, such as filter type, face velocity, sampling duration, and ambient conditions, in this field study two different filter types have been considered (i.e. quartz fibre filters and Teflon filters) for the assessment of both inorganic and organic artefacts during two different seasons (performing also some samplings at different flow-rates).Results showed that positive artefacts due to OC adsorption on quartz filters accounted for 39% of the OC measured concentration in summer, and 23% in winter. Negative artefact due to nitrate volatilisation by the filters was 51% on Teflon and 22% on the quartz filters in summer, and no or negligible losses were observed in winter. A significant improvement in the PM mass comparability obtained in parallel samplings on different filters was obtained taking into account the artefact estimates performed in this study.  相似文献   

19.
Fine PM measurements: personal and indoor air monitoring   总被引:3,自引:0,他引:3  
This review compiles personal and indoor microenvironment particulate matter (PM) monitoring needs from recently set research objectives, most importantly the NRC published "Research Priorities for Airborne Particulate Matter (1998)". Techniques and equipment used to monitor PM personal exposures and microenvironment concentrations and the constituents of the sampled PM during the last 20 years are then reviewed. Development objectives are set and discussed for personal and microenvironment PM samplers and monitors, for filter materials, and analytical laboratory techniques for equipment calibration, filter weighing and laboratory climate control. The progress is leading towards smaller sample flows, lighter, silent, independent (battery powered) monitors with data logging capacity to store microenvironment or activity relevant sensor data, advanced flow controls and continuous recording of the concentration. The best filters are non-hygroscopic, chemically pure and inert, and physically robust against mechanical wear. Semiautomatic and primary standard equivalent positive displacement flow meters are replacing the less accurate methods in flow calibration, and also personal sampling flow rates should become mass flow controlled (with or without volumetric compensation for pressure and temperature changes). In the weighing laboratory the alternatives are climatic control (set temperature and relative humidity), and mechanically simpler thermostatic heating, air conditioning and dehumidification systems combined with numerical control of temperature, humidity and pressure effects on flow calibration and filter weighing.  相似文献   

20.
This paper reviews the effects and control methods for particulate matter (PM) in animal indoor environments. PM in animal indoor environments represents a particular threat to the health of countless animals and millions of workers around the world. Because air in animal facilities has a higher portion of biological content than does air in other environments, the adverse health impact is much greater than it is for the same amount of PM in other environments. Source control, ventilation, and internal air cleaning can reduce PM concentration in animal indoor environments. Source control is typically the most economical method for PM control. Ventilation is the most widely applied technology, although uncertainties remain as to its effectiveness for PM control. Most internal air cleaners require frequent maintenance because of the high concentration and stickiness of PM in animal environments. Filtration is the most well-studied and widely used technology for internal air cleaning because of its low capital cost and high efficiency. Several trials using electrostatic precipitators have shown efficiencies of approximately 50% in removing PM concentration, but improvements are needed before they can be used widely. No report using wet collectors or centrifugals as internal air cleaners has been found.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号