首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Polyethylene-based passive air samplers (PSDs) were loaded with performance reference compounds (PRCs) and deployed in a wind tunnel to examine the effects of wind speed on sampler performance. PRCs could be loaded reproducibly into PSDs, with coefficients of variation only exceeding 20% for the more volatile compounds. When PSDs were exposed to low (0.5-1.5 m s-1) and high (3.5-4.5 m s-1) wind speeds, PRC loss rate constants generally increased with increasing wind speed and decreased with increasing sampler/air partition coefficients. PSD-based air concentrations calculated using PRC loss rate constants and sampler/air partition coefficients and air concentrations measured using active samplers compared closely. PRCs can be used to account for the effect of differences in wind speeds on sampler performance and measure air concentrations with reasonable accuracy.  相似文献   

2.
Passive samplers with two different collection substrates were used to obtain an average ozone concentration for 1 month during the summer of 2002 for each South Carolina county. One sampler contained a filter coated with indigo carmine, whose color fades when exposed to ozone. The fading was measured by reflectance spectroscopy. The other sampler contained filters that were coated with nitrite, which is oxidized to nitrate when exposed to ozone. The nitrate was measured by ion chromatography. Calibration curves were developed for the two methods by comparing color fading from indigo carmine and nitrate ion concentration from the nitrite filter with ambient ozone concentration measured by a co-located reference continuous UV ozone analyzer. These curves were used to calculate integrated ozone concentrations for samplers distributed across South Carolina. Using the indigo carmine method, the average ozone concentrations ranged from 21 to 64 ppb (average = 46 +/- 7.9 ppb, n = 58) across the 46 counties in the state during one summer month of 2002. Concentrations for the same time period from the nitrite-coated filters ranged from 23 to 62 ppb (average = 41 +/- 8.1 ppb, n = 58). Also for the same time period, the 23 continuous UV photometric ozone monitors operated by the South Carolina Department of Health and Environmental Control at sites within 10 miles of some of the passive monitors showed ozone concentrations ranging from 28 to 50 ppb (average = 39 +/- 6.3 ppb, n = 22).  相似文献   

3.
Highly portable, sensitive, and selective passive air samplers were used to investigate ambient volatile organic compound (VOC) levels at multiple sampling sites in an industrial city, Fuji, Japan. We determined the spatial distributions of 27 species of VOCs in three campaigns: Mar (cold season), May (warm season), and Nov (mild season) of 2004. In all campaigns, toluene (geometric mean concentration, 14.0microg/m3) was the most abundant VOC, followed by acetaldehyde (4.76microg/m3), and formaldehyde (2.58microg/m3). The spatial distributions for certain VOCs showed characteristic patterns: high concentrations of benzene and formaldehyde were typically found along major roads, whereas high concentrations of toluene and tetrachloroethylene (PCE) were usually found near factories. The spatial distribution of PCE observed was extremely consistent with the diffusion pattern calculated from Pollutant Release and Transfer Register data and meteorological data, indicated that passive air samplers are useful for determining the sources and distributions of ambient VOCs.  相似文献   

4.
The concentrations of polychlorinated dibenzo-p-dioxins and furans (PCDD/Fs), polychlorinated biphenyls (PCBs) and polychlorinated naphthalenes (PCNs) were determined in air samples collected at four sampling sites located in two zones of Barcelona (Spain): near a municipal solid waste incinerator (MSWI) and a combined cycle power plant (3 sites), and at a background/control site. Samples were collected using high-volume active samplers. Moreover, 4 PUF passive samplers were deployed at the same sampling points during three months. For PCDD/Fs, total WHO-TEQ values were 27.3 and 10.9 fg WHO-TEQm(-3) at the urban/industrial and the background sites, respectively. The sum of 7 PCB congeners and the Sigma PCN levels were also higher at the industrial site than at the background site. In order to compare active and passive sampling, the accumulated amounts of PCDD/Fs, PCBs and PCNs in the four passive air samplers, as well as the total toxic equivalents in each sampling site were also determined. To assess the use of PUF passive samplers as a complementary tool for PCDD/F, PCB and PCN monitoring, sampling rates were calculated in accordance with the theory of passive air samplers. PUF disks allowed establishing differences among zones for the POP levels, showing that they can be a suitable method to determine POP concentrations in air in areas with various potential emission sources. Although both particle and gas phase were sorbed by the PUFs, data of gas phase congeners are more reproducible.  相似文献   

5.
Paschke H  Popp P 《Chemosphere》2005,58(7):855-863
Two new types of passive samplers were designed and tested on semivolatile organic compounds. The first type (a spiral-rod sampler) consists of a low-density polyethylene membrane acting as a permeation film and a silicone elastomer as the receiving material; the second (a stir-bar sampler) has the same membrane material but a polydimethylsiloxane-coated stir bar acting as the collector phase and installed radially symmetrically in the sampler. The advantages of the new samplers are their simple design, low costs, and their easy processing via thermodesorption coupled with capillary gas chromatography and mass selective detection. In both samplers, the uptake of selected analytes was integrative over exposure periods of up to 384 h. The sampling rates calculated from a laboratory calibration study using the chlorinated semivolatiles hexachlorobenzene, hexachlorocyclohexane isomers and polychlorinated biphenyls ranged from 88.1 ml h-1 for delta-hexachlorocyclohexane to 3443 ml h-1 for 2,2',5,5'-tetrachlorobiphenyl. A field trial at a hazardous waste dump near Bitterfeld, Germany, for up to 21 days combined with periodical determinations of air concentrations using low-volume sampling indicated that the new samplers can in principle be used in the field, although the sampling rates derived from the field results differed considerably from the laboratory findings. Nevertheless the preliminary results suggest that the new sampler types are promising for the long-term air monitoring of semivolatiles.  相似文献   

6.
XAD-2 resin-based passive samplers (PAS) with dimensions adapted to 100 mL accelerated solvent extraction cells were used to study the temporal and spatial variations of 17 PAHs on five sites in the atmosphere of southern Luxembourg. This new design allowed extracting the PAS without emptying the resin from the shelter. PAH analyses were done with gas chromatography–tandem mass spectrometry. PAS were deployed for 1 year with varying sampling periodicities, and 16 PAHs were detected with concentrations ranging from 1 ng/PAS for chrysene to 9,727 ng/PAS for naphthalene. The PAS were found adapted to the monitoring of temporal and spatial variations for lightweight PAHs (up to four aromatic rings) though not for heavy PAHs with five aromatic rings or more, as these compounds are preferably in the particle phase of the atmosphere and the amount of these PAHs trapped on the PAS will be too low.  相似文献   

7.
Harman C  Tollefsen KE  Bøyum O  Thomas K  Grung M 《Chemosphere》2008,72(10):1510-1516
Passive sampling devices provide a useful contribution to the monitoring of contaminants in the aquatic environment. However, calibration data needed for the calculation of water concentrations from sampler accumulations are restricted to a limited number of compound classes. Thus uptake of a range of alkylated phenols (AP), polycyclic aromatic hydrocarbons (PAH) and carbazoles was determined for semipermeable membrane devices (SPMDs) and polar organic chemical integrative samplers (POCIS) using a flow through exposure system. Sampling rates ranged from 0.02 to 0.26 l d(-1) for POCIS and 0.02 to 13.83 l d(-1) for SPMDs. Observed SPMD uptake was also compared to that predicted by an empirical model including the use of performance reference compounds (PRCs). Predicted sampling rates did not differ by more than a factor of 1.3 from experimental values for PAH, providing further evidence that the PRC approach can be successfully used to determine in situ sampling rates for these compounds. Experimental sampling rates for AP in SPMDs were, however, much lower than predicted. This discrepancy was too large to be explained by small uncertainties in the calibration system or in the calculations. Based on these data we conclude that while hydrophobic AP are accumulated by SPMDs their partitioning cannot be predicted from their logK(ow) using current methods. Due to this lower than expected uptake, sampling rates were only higher in SPMDs than POCIS in the range of logK(ow)>5.0. Simultaneous deployment of both sampler types allows the study of compounds with a broad range of physicochemical properties.  相似文献   

8.
Polyurethane foam (PUF) disks were deployed at global background sites, to test logistical issues associated with a global monitoring network for persistent organic pollutants (POPs). alpha-HCH, exhibited relatively high and uniform concentrations (17-150 pg/m3) at temperate and arctic sites with elevated concentrations associated with trans-Pacific inflow. Concentrations were much lower (<5 pg/m3) in Bermuda, Chile and Cape Grim. Concentrations for gamma-HCH, the main component of lindane, were spatially similar to the alpha-HCH pattern but lower in magnitude (typically, <10 pg/m3). Chlordane concentrations (sum of cis-chlordane, trans-chlordane and trans-nonachlor) were also low (<10 pg/m3). Dieldrin concentrations were in the range 2-25 pg/m3 at most sites but elevated in Bermuda. Back trajectories suggest that advection from Africa and the US may contribute. Endosulfan, a popular current-use pesticide, exhibited highest concentrations ranging from tens to hundreds of pg/m3. There was good agreement between duplicate samplers at each site and PUF disk-derived air concentrations agreed with high volume data. Few logistical/analytical problems were encountered in this pilot study.  相似文献   

9.
Semi-permeable membrane devices (SPMDs) were loaded with deuterated anthracene and pyrene as performance reference compounds (PRCs) and deployed at a test site in four different chambers (open and closed box chamber, bowl chamber and cage chamber) for 29 days. The losses of PRCs and the uptake of polyaromatic hydrocarbons (PAHs) from the ambient air were quantified. UV-B levels measured in each deployment chamber indicated that SPMDs would be exposed to the most UV-B in the cage chamber and open box chamber. Significantly less PAHs were quantified in SPMDs deployed in the cage chamber and open box chamber compared to samplers from the other two chambers, suggesting that photodegradation of PAHs had occurred. The loss of PRCs confirmed these results but also showed that photodegradation was occurring in the closed box chamber. The bowl chamber appears to provide the best protection from the influence of direct photodegradation.  相似文献   

10.
Select volatile organic compounds (VOCs) were measured in the vicinity of a petroleum refinery and related operations in South Philadelphia, Pennsylvania, USA, using passive air sampling and laboratory analysis methods. Two-week, time-integrated samplers were deployed at 17 sites, which were aggregated into five site groups of varying distances from the refinery. Benzene, toluene, ethylbenzene, and xylene isomers (BTEX) and styrene concentrations were higher near the refinery’s fenceline than for groups at the refinery’s south edge, mid-distance, and farther removed locations. The near fenceline group was significantly higher than the refinery’s north edge group for benzene and toluene but not for ethylbenzene or xylene isomers; styrene was lower at the near fenceline group versus the north edge group. For BTEX and styrene, the magnitude of estimated differences generally increased when proceeding through groups ever farther away from the petroleum refining. Perchloroethylene results were not suggestive of an influence from refining. These results suggest that emissions from the refinery complex contribute to higher concentrations of BTEX species and styrene in the vicinity of the plant, with this influence declining as distance from the petroleum refining increases.

Implications: Passive sampling methodology for VOCs as discussed here is employed in recently enacted U.S. Environmental Protection Agency Methods 325A/B for determination of benzene concentrations at refinery fenceline locations. Spatial gradients of VOC concentration near the refinery fenceline were discerned in an area containing traffic and other VOC-related sources. Though limited, these findings can be useful in application of the method at such facilities to ascertain source influence.  相似文献   


11.
The first survey of persistent organic pollutant (POP) concentrations in air across several Indian agricultural regions was conducted in 2006-2007. Passive samplers comprising polyurethane foam (PUF) disks were deployed on a quarterly basis at seven stations in agricultural regions, one urban site and one background site. The project was conducted as a sub-project of the Global Atmospheric Passive Sampling (GAPS) Network. In addition to revealing new information on air concentrations of several organochlorine pesticides (OCPs) and polychlorinated biphenyls (PCBs), the study has demonstrated the feasibility of conducting regional-scale monitoring for POPs in India using PUF disk samplers. The following analytes were detected with relatively high concentrations in air (mean for 2006 and 2007, pg/m3): α- and γ-hexachlorocyclohexane (HCH) (292 and 812, respectively); endosulfan I and II (2770 and 902, respectively); p,p′-DDE and p,p′-DDT (247 and 931, respectively); and for the sum of 48 PCBs, 12,100 (including a site with extremely high air concentrations in 2007) and 972 (when excluding data for this site).  相似文献   

12.
13.
A passive air sampler was developed for collecting polycyclic aromatic hydrocarbons (PAHs) in air mass from various directions. The airflow velocity within the sampler was assessed for its responses to ambient wind speed and direction. The sampler was examined for trapped particles, evaluated quantitatively for influence of airflow velocity and temperature on PAH uptake, examined for PAH uptake kinetics, calibrated against active sampling, and finally tested in the field. The airflow volume passing the sampler was linearly proportional to ambient wind speed and sensitive to wind direction. The uptake rate for an individual PAH was a function of airflow velocity, temperature and the octanol-air partitioning coefficient of the PAH. For all PAHs with more than two rings, the passive sampler operated in a linear uptake phase for three weeks. Different PAH concentrations were obtained in air masses from different directions in the field test.  相似文献   

14.
Nine polycyclic aromatic hydrocarbons (PAHs) were analysed in pine needles of different ages (from 6 to 30 months) collected from two species, Pinus nigra and Pinus pinaster, in seven sites located along a transect from a suburban to a rural area of Genoa (Italy). In all sites and for both species, concentrations of more volatile PAHs (phenanthrene, anthracene, fluoranthene, pyrene) were higher than those for other less volatile PAHs, which are preferentially sorbed to airborne particulates (benzo[a]anthracene, chrysene, benzofluoranthenes, benzo[a]pyrene). Concentrations of total PAHs found in P. nigra in the rural sites were, on the average, 2.3 times higher than those in P. pinaster growing nearby. In both pine species, concentrations of volatile PAHs increased according to needle age. Annual trends of other PAHs were more variable, with a general decrease in older needles. P. pinaster needles are shown to be more reliable passive samplers, since they are more resistant to plant diseases, and considerable variation in PAH concentration was observed in P. nigra needles with moulds and fungi.  相似文献   

15.
Li X  Li Y  Zhang Q  Wang P  Yang H  Jiang G  Wei F 《Chemosphere》2011,84(7):957-963
The concern about emissions of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) polychlorinated biphenyls (PCBs), and polybrominated diphenyl ethers (PBDEs) from steel industrial parks has increased in the past decades. In this study, polyurethane foam (PUF)-disk based passive air samples were collected in and around a big steel industrial park of Anshan, Northeast China from June 2008 to March 2009. The levels, seasonal variations and potential sources of PCDD/Fs, PCBs and PBDEs in the atmosphere around the steel industrial complex were investigated, and potential contribution of these three groups of persistent organic pollutants (POPs) from iron and steel production was also assessed. The air concentrations of ∑17PCDD/Fs (summer: 0.02-2.77 pg m−3; winter: 0.20-9.79 pg m−3), ∑19PCBs (summer: 23.5-155.8 pg m−3; winter: 14.6-81.3 pg m−3) and ∑13PBDEs (summer: 2.91-10.7 pg m−3; winter: 1.10-3.89 pg m−3) in this targeted industrial park were relatively low in comparison to other studies, which implied that the industrial activities of iron and steel had not resulted in serious contamination to the ambient air in this area. On the whole, the air concentrations of PCDD/Fs in winter were higher than those of summer, whereas the concentrations of PCBs and PBDEs showed opposite trends. The result from principal component analysis indicated that coal combustion might be the main contributor of PCDD/F sources in this area.  相似文献   

16.
Membrane-enclosed copolymer (MECOPs) samplers containing crystalline copolymers of ethylvinylbenzene-divinylbenzene in polyethylene membranes were used to assess the influence of a steel complex on the level and spatial distribution of polycyclic aromatic hydrocarbons (PAHs) in ambient air. MECOPs were deployed at six sites in Pohang, Korea for 37 days (August 9, 2005–September 14, 2005). Fluorene, phenanthrene, anthracene, and fluoranthene were dominant PAHs with the highest contribution of phenanthrene (59%) to the total amount of vapor-phase PAHs. The spatial distribution of total PAHs in the vapor phase ranging from 76 to 1077 ng MECOP−1 and air dispersion modeling suggested that the steel complex was the major PAH source in Pohang. It was revealed that the major wind directions rather than the distance from the steel complex were a significant factor affecting the levels of PAHs at the sampling sites. Finally, we tried to convert MECOP concentrations (ng MECOP−1) to air concentrations (ng m−3) with the modified sampling rates (m3 day−1). This study demonstrates again that passive air samplers are useful tools for spatially resolved and time-integrated monitoring of semivolatile organic compounds (SOCs) in ambient air.  相似文献   

17.
18.
An improved ion chromatographic (IC) method has been developed for the separation of nitrate in filter extracts in the presence of high concentrations of nitrite. This analytical method was successfully used for an indirect measurement of ozone (O3) in outdoor and indoor air, following its collection using a nitrite-impregnated passive sampler. The limit of detection and the limit of quantification, using the modified IC method, were 6 microg l(-1) (3sigma) and 20 microg l(-1) (10sigma), respectively. Improved detection limits and low baseline noise were obtained with the use of eluent generator and high-capacity ion exchange column. The optimized method was used for assessing O3 concentration in both indoor and outdoor environments of 28 child care centers (CCCs) located in different parts of Singapore. The O3 concentrations ranged from 0.1 to 11.95 parts per billion (ppb) in indoor and from 3.2 to 21.7 ppb in outdoor environments during the study period. It was found that, among the CCCs investigated in this study, air-conditioned CCCs and those located in close proximity to traffic emissions had significantly lower O3 concentrations indoors.  相似文献   

19.
Semipermeable membrane devices (SPMDs) were used for measurements in air of twelve polycyclic aromatic hydrocarbons (PAHs) in two Genoa locations, both on building roofs, distant 300 m from each other. The first, site A, was in front a dismissing steel complex and the second, site B, was in an urban area overlooking a busy thoroughfare. SPMDs were deployed contemporary at the two sites, in nine monthly samplings, from April 2007 to May 2008. The amount of sequestered PAHs, in sites A and B, ranged between 61–267 ng SPMD?1 d?1 and 50–535 ng SPMD?1 d?1, respectively.PAHs profiles highlighted seasonal differences and suggested the possible role of different PAHs sources in the two areas. In particular, the contribution of remediation works of the steel complex was observed in site A. Moreover, a naphthalene leak from a tank, into the former industrial area, and a fire broke out near site A, were registered by time-integrated measurements of SPMDs.However, the strong dependence between amount of sequestered PAHs and air temperature needs further studies to distinguish between uptake rate variability and seasonal contribution of different sources. Finally, to measure air concentrations with reasonable accuracy, it should be very important to have certified sampling rates for all individual PAHs.  相似文献   

20.
Atmospheric sampling of organochlorine pesticides (OCPs) was conducted using Semi Permeable Membrane Devices (SPMDs) deployed in the Alps at different altitudinal transects for two consecutive exposure periods of half a year and a third simultaneous year-long period. Along all the altitude profiles, the sequestered amounts of OCPs increased in general with altitude. SPMDs were still working as kinetic samplers after half a year for the majority of the OCPs. However, compounds with the lowest octanol-air partition coefficient (Koa), reached equilibrium within six months. This change in the SPMD uptake was determined for the temperature gradient along the altitude profile influencing Koa, OCPs availability in the gaseous phase, and SPMD performance. In sum, it seems two effects are working in parallel along the altitude profiles: the change in SPMD performance and the different availability of OCPs along the altitudinal transects determined by their compound properties and concentrations in air.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号