Environmental Science and Pollution Research - Toxic cyanobacterial blooms (TCBs) have become a growing concern worldwide. The present study investigated the dynamic of toxic cyanobacteria and... 相似文献
We report relatively high citrulline concentration in amniotic fluid of a citrullinemic fetus suggesting that prenatal detection of this condition could be done on this basis in conjunction with a direct or an indirect determination of argininosuccinate synthetase activity in amniotic fluid cells. 相似文献
Prenatal diagnosis of chronic granulomatous disease (CGD) was performed in four male high risk fetuses. The male sex was previously determined by an amniotic cell karyotype. Three kinds of test were performed on fetal blood obtained by umbilical venous puncture under fetoscopy at the 20th gestational week: nitroblue tetrazolium reduction (NBT) cytochemical test with phorbol myristate acetate (PMA) as activator; luminol enhanced chemiluminescence with activation by serum opsonized zymosan (STZ) or PMA; superoxide anion (0) production by measurement of the superoxide dismutase inhibitable reduction of cytochrome c with PMA as activator. Results were compared to those obtained in six fetuses investigated for other inherited diseases. In one case, absence of granulocyte defects was confirmed at birth. In three other cases, the tests showed deficient metabolic oxidative granulocytes. The pregnancy was terminated and the CGD diagnosis was confirmed on the products of abortion. The use of three different techniques performed on whole blood for CGD prenatal diagnosis is recommended instead of a single isolated test to ensure a higher confidence in the diagnosis. 相似文献
Journal of Material Cycles and Waste Management - Human and livestock waste, i.e., excreta, were intensively used in crop cultivation in Asia over the years. However, rapid economic growth induced... 相似文献
In this study, different pretreatment strategies of sugarcane bagasse prior to citric acid modification were investigated in terms of Pb2+ adsorption capacity. Pretreatment strategies included the use of NaOH, HCl, and C2H5OH in various concentrations. In order to fundamentally understand how these pretreatment methods affect the modification of sugarcane bagasse by citric acid as well as the Pb2+ adsorption capacity of sugarcane bagasse, three main components of sugarcane bagasse namely cellulose, hemicellulose, and lignin were isolated and esterified by citric acid under the same conditions. ATR-FTIR, XPS, SEM, and an analysis of the number of carboxylic acid groups were used to investigate the physicochemical and chemical properties of the materials. These three components were proved to participate in adsorption and induce the esterification with citric acid. Hence, pretreatment with ethanol and 0.01 M NaOH which could retain cellulose, hemicellulose, and lignin in sugarcane bagasse achieved a high Pb2+ adsorption capacity, i.e., 122.4 and 97 mg/g after the esterification with citric acid. In contrast, pretreatment with 0.5 M NaOH and 0.1 M HCl removed lignin and hemicellulose, leading to the lowest value of approximately 45 mg/g for citric acid esterified-pretreated sugarcane bagasse. XPS analysis and number of carboxylic group measurement confirmed the esterification between bagasse and citric acid. To understand the adsorption mechanism of adsorbent, two kinetic models including pseudo-first-order model and pseudo-second-order model were applied. The experimental data were well described by the pseudo-second-order model. The adsorption isotherm data were fitted Langmuir and Freundlich.
Environmental Science and Pollution Research - The failure of the centralized water supply system forced XY community to become more dependent on uncertain and unstable water sources. The results... 相似文献
Monitoring of benzene, toluene and xylenes (BTEX) was conducted along with traffic counts at 17 roadside sites in urban areas of HoChiMinh. Toluene was the most abundant substance, followed by p,m-xylenes, benzene, o-xylene and ethylbenzene. The maximum observed hour-average benzene concentration was 254 μg/m3 . Motorcycles contributed to 91% of the traffic fleet. High correlations among BTEX species, between BTEX concentrations and the volume of on-road motorcycles, and between inter-species ratios in air and in gasoline indicate the motorcycle-exhaust origin of BTEX species. Daily concentrations of benzene, toluene, ethylbenzene, p,m-xylenes and o-xylene were 56, 121, 21, 64 and 23 μg/m 3 , respectively. p,m-xylenes possess the highest ozone formation potential among the BTEX family. 相似文献
• Effects of metabolic uncoupler TCS on the performances of GDMBR were evaluated.• Sludge EPS reduced and transformed into dissolved SMP when TCS was added.• Appropriate TCS increased the permeability and reduced cake layer fouling.• High dosage aggravated fouling due to compact cake layer with low bio-activity. The gravity-driven membrane bioreactor (MBR)system is promising for decentralized sewage treatment because of its low energy consumption and maintenance requirements. However, the growing sludge not only increases membrane fouling, but also augments operational complexities (sludge discharge). We added the metabolic uncoupler 3,3′,4′,5-tetrachlorosalicylanilide (TCS) to the system to deal with the mentioned issues. Based on the results, TCS addition effectively decreased sludge ATP and sludge yield (reduced by 50%). Extracellular polymeric substances (EPS; proteins and polysaccharides) decreased with the addition of TCS and were transformed into dissolved soluble microbial products (SMPs) in the bulk solution, leading to the break of sludge flocs into small fragments. Permeability was increased by more than two times, reaching 60–70 L/m2/h bar when 10–30 mg/L TCS were added, because of the reduced suspended sludge and the formation of a thin cake layer with low EPS levels. Resistance analyses confirmed that appropriate dosages of TCS primarily decreased the cake layer and hydraulically reversible resistances. Permeability decreased at high dosage (50 mg/L) due to the release of excess sludge fragments and SMP into the supernatant, with a thin but more compact fouling layer with low bioactivity developing on the membrane surface, causing higher cake layer and pore blocking resistances. Our study provides a fundamental understanding of how a metabolic uncoupler affects the sludge and bio-fouling layers at different dosages, with practical relevance for in situ sludge reduction and membrane fouling alleviation in MBR systems. 相似文献
The sigma (SIG) coordinate system in ocean circulation simulation models results inevitably in horizontal pressure gradient error. This problem also emerges in models of deep lakes or reservoirs with the same characteristics of underwater terrain mutation. SIG coordinates reflect vertical relative stratification but cannot be used to calculate horizontal pressure gradient force in places with drastic topographic changes; this results in vertical water temperature and circulation errors. In deep lakes or reservoirs, differences in water density caused by the temperature difference between upper and lower water bodies is the primary cause of thermal stratification phenomena. Lake Mead was used as a case study on steep topography based on Environmental Fluid Dynamics Code (EFDC) model in this study. SIG coordinates result in close agreement between the calibrated temperature time series at the top and middle water layers, but disparity in the bottom water layer. The error emerges in the horizontal pressure gradient error due to the SIG coordinate transformation. Neither increasing the vertical resolution nor adjusting the horizontal viscosity coefficient resolve this error. We test the sigma-zed (SGZ) coordinate which combines Z coordinate and SIG coordinate as a replacement for the SIG coordinate to find that they effectively reduce the model’s runtime and simulation efficiency. The vertical temperature distribution in SGZ coordinate mode is more accurate than the distribution in SIG coordinate mode. The Navier-Stokes horizontal gradient and advection diffusion equation results under SIG coordinates are very sensitive to the pressure gradient. The replacement also enhances resolution near the thermocline, facilitates reclosing of the water bottom and the equal sigma surface, lends significant advantages in terms of vertical temperature in the simulation for local deep water with steep terrain, and shortens runtime for 0.14 h. SGZ mixed coordinates are recommended in the simulation of deep lakes or reservoirs wherein the underwater topography is large (with abundant continuous deep trenches or reefs).