全文获取类型
收费全文 | 66篇 |
免费 | 1篇 |
国内免费 | 5篇 |
专业分类
安全科学 | 1篇 |
废物处理 | 6篇 |
环保管理 | 8篇 |
综合类 | 10篇 |
基础理论 | 15篇 |
污染及防治 | 22篇 |
评价与监测 | 8篇 |
社会与环境 | 2篇 |
出版年
2022年 | 2篇 |
2021年 | 2篇 |
2019年 | 2篇 |
2018年 | 1篇 |
2017年 | 3篇 |
2016年 | 1篇 |
2015年 | 4篇 |
2014年 | 4篇 |
2013年 | 1篇 |
2012年 | 5篇 |
2011年 | 5篇 |
2010年 | 1篇 |
2009年 | 6篇 |
2008年 | 7篇 |
2007年 | 7篇 |
2006年 | 2篇 |
2005年 | 7篇 |
2004年 | 4篇 |
2003年 | 4篇 |
2002年 | 1篇 |
2001年 | 1篇 |
1997年 | 1篇 |
1991年 | 1篇 |
排序方式: 共有72条查询结果,搜索用时 15 毫秒
1.
Repeated application may increase rates of pesticide dissipation in soil and reduce persistence. The potential for this to occur was investigated for the fungicide, tebuconazole (alpha-[2-(4-chlorophenyl)ethyl]-alpha-(1,1-dimethylethyl)-1H-1,2,4-triazole-1-ethanol), when used for peanut (Arachis hypogaea L.) production. Soil samples were collected from peanut plots after each of four tebuconazole applications at 2-wk intervals. Soil moisture was adjusted to field capacity as necessary and samples were incubated in the laboratory for 63 d at 30 degrees C. Untreated plot samples spiked with the compound served as controls. Results indicated accelerated dissipation in field-treated samples with the time to fifty percent dissipation (DT50) decreasing from 43 to 5 d after three tebuconazole applications. Corresponding increases in rates of accumulation and decay of degradates were also indicated. Best-fit equations (r2 = 0.84-0.98) to dissipation kinetic data combined with estimates of canopy interception rates were used to predict tebuconazole and degradates concentration in soil after each successive application. Predicted concentrations compared with values measured in surface soil samples were from twofold less to twofold greater. Use of kinetic data will likely enhance assessments of treatment efficacy and human and ecological risks from normal agronomic use of tebuconazole on peanut. However, the study indicated that varying soil conditions (in particular, soil temperature and water content) may have an equal or greater impact on field dissipation rate than development of accelerated dissipation. Results emphasize that extension of laboratory-derived kinetic data to field settings should be done with caution. 相似文献
2.
We started the monitoring for PCDD/Fs in ambient air and soil in August 2001, and co-PCBs in January 2002. Decreasing of PCDD/Fs and co-PCBs levels in ambient air were observed. The higher PCDD/Fs levels were found in winter and lower in autumn. We found that the industrial incinerators influenced the PCDD/Fs levels in ambient air. In the 2,3,7,8-substituted PCDD/Fs concentration profiles, the three major congeners occupied 67% of the total mass. In case of co-PCBs, PCB#118, #105 and #77 were observed as the main congeners. Five cluster groups discriminated by ratio of four components, O(8)CDD, 1,2,3,4,6,7,8-H(7)CDD, 1,2,3,4,6,7,8-H(7)CDF and O(8)CDF, were obtained from HCA (hierarchical cluster analysis). 相似文献
3.
Performance of an electrochemical COD (chemical oxygen demand) sensor with an electrode-surface grinding unit 总被引:2,自引:0,他引:2
Geun Jeong B Min Yoon S Ho Choi C Koang Kwon K Sik Hyun M Heui Yi D Soo Park H Kim M Joo Kim H 《Journal of environmental monitoring : JEM》2007,9(12):1352-1357
An electrochemical COD (chemical oxygen demand) sensor using an electrode-surface grinding unit was investigated. The electrolyzing (oxidizing) action of copper on an organic species was used as the basis of the COD measuring sensor. Using a simple three-electrode cell and a surface grinding unit, the organic species is activated by the catalytic action of copper and oxidized at a working electrode, poised at a positive potential. When synthetic wastewater was fed into the system, the measured Coulombic yields were found to be dependent on the COD of the synthetic wastewater. A linear correlation between the Coulombic yields and the COD of the synthetic wastewater was established (10-1000 mg L(-1)) when the electrode-surface grinding procedure was activated briefly at 8 h intervals. When various kinds of wastewater samples obtained from various sewage treatment plants were measured, linear correlations (r(2)> or = 0.92) between the measured EOD (electrochemical oxygen demand) value and COD of the samples were observed. At a practical wastewater treatment plant, the measurement system was successfully operated with high accuracy and good stability over 3 months. These experimental results show that the application of the measurement system would be a rapid and practical method for the determination of COD in water industries. 相似文献
4.
Choi JH Kim YH Joo DJ Choi SJ Ha TW Lee DH Park IH Jeong YS 《Journal of the Air & Waste Management Association (1995)》2003,53(1):92-101
The characteristics of ammonia removal by two types of biofilter (a standard biofilter with vertical gas flow and a modified biofilter with horizontal gas flow) were investigated. A mixture of organic materials such as compost, bark, and peat was used as the biofilter media based on the small-scale column test for media selection. Complete removal capacity, defined as the maximum inlet load of ammonia that was completely removed, was obtained. The modified biofilter showed complete removal up to 1.0 g N/kg dry material/day. However, the removal capacity of the standard biofilter started to deviate from complete removal around 0.4 g N/kg dry material/day, indicating that the modified biofilter system has higher removal efficiency than the standard upflow one. In kinetic analysis of the biological removal of ammonia in each biofilter system, the maximum removal rate, Vm, was 0.93 g N/kg dry material/day and the saturation constant, Ks, was 32.55 ppm in the standard biofilter. On the other hand, the values of Vm and Ks were 1.66 g N/kg dry material/day and 74.25 ppm, respectively, in the modified biofilter system. 相似文献
5.
UV Spectroscopic Monitoring of Vaporized Monoaromatic Hydrocarbons from Petroleum-Contaminated Soils
Fast and simple systems using ultraviolet (UV) absorbance were examined for on-line monitoring of monoaromatic hydrocarbons from petroleum-contaminated soils in this research. Since soil particles hinder the UV light transmittance, the absorbance measurement of vaporized monoaromatic hydrocarbons in soil gas extracted from petroleum-contaminated soils was proposed. In the fixed system that exhibited higher sensitivity than the portable one, the absorbance intensity of benzene, toluene, ethylbenzene, and xylene increased in proportion to the concentration of the contaminants. The portable system, however, was suitable for screening purpose, while it exhibited faster response. There was no interference from water, which helps the applicability of the proposed systems to the actual fields. 相似文献
6.
Distribution characteristics of PCBs in the sediments of the lower Nakdong River, Korea 总被引:1,自引:0,他引:1
The objective of this study is to investigate the distribution characteristics of polychlorinated biphenyl (PCB) congeners in sediments of the lower Nakdong River of Korea. The sediments were collected using a grab sampler in May 1999. PCBs were extracted in the Soxhlet extractor and cleaned by using adsorption chromatographic techniques and concentrated sulfuric acid. A HP6890 gas chromatograph equipped with an electron capture detector was used for quantification. The results of congener specific analysis showed that the total concentration is ranged over 1.1-141 ng/g dry weight. The levels of PCB congeners are significantly correlated with the total organic carbons (TOC) in the sediments. The major fractions of PCBs in these sediments are congeners containing 4, 5 or 6 chlorine atoms per biphenyl molecule. 相似文献
7.
Zare Ehsan Nazarzadeh Fallah Zari Le Van Thuan Doan Van-Dat Mudhoo Ackmez Joo Sang-Woo Vasseghian Yasser Tajbakhsh Mahmood Moradi Omid Sillanpää Mika Varma Rajender S. 《Environmental Chemistry Letters》2022,20(4):2629-2664
Environmental Chemistry Letters - The release of pharmaceuticals into the environment induces adverse effects on the metabolism of humans and other living species, calling for advanced remediation... 相似文献
8.
9.
Low-level liquid borate wastes have been immobilized with paraffin wax using a concentrate waste drying system (CWDS) in Korean nuclear power plants. The possibility for improving chemical durability of paraffin waste form was suggested in this study. A small amount of low density polyethylene (LDPE) was added to increase the leaching resistance of the existing paraffin waste form. The influence of LDPE on the leaching behavior of waste form was investigated by performing leaching test according to ANSI/ANS-16.1 procedure during 325 days. It was observed that the leaching of nuclides immobilized within paraffin waste form made a marked reduction although little content of LDPE was added to waste form. The acceptance criteria of paraffin waste form associated with leachability index (LI) and compressive strength after the leaching test were fully satisfied with the help of LDPE. 相似文献
10.
In this study, chlorine decay experiments were conducted for the raw water from Nakdong River that is treated by Chilseo Water
Treatment Plant (CWTP) situated in Haman, Korea as well as the e uents from sand and granular activated carbon (GAC) filters of
CWTP and fitted using a chlorine decay model. The model estimated the fast and slow reacting nitrogenous as well as organic/inorganic
compounds that were present in the water. It was found that the chlorine demand due to fast and slow reacting (FRA and SRA)
organic/inorganic substances was not reduced significantly by sand as well as GAC filters. However, the treated e uents from those
filters contained FRA and SRA that are less reactive and had small reaction rate constants. For the e uents from microfiltration,
ultrafiltration, and nanofiltration the chlorine demand because FRA and SRA were further reduced but the reaction rate constants were
larger compared to those of sand and GAC filter e uents. This has implications in the formation of disinfection by products (DBPs).
If DBPs are assumed to form due to the interactions between chlorine and SRA, then it is possible that the DBP formation potential in
the e uents from membrane filtrations could be higher than that in the e uents from granular media filters. 相似文献