Nature-based solutions (NBS) find increasing attention as actions to address societal challenges through harnessing ecological processes, yet knowledge gaps exist regarding approaches to landscape planning with NBS. This paper aims to provide suggestions of how planning NBS can be conceptualized and applied in practice. We develop a framework for planning NBS by merging insights from literature and a case study in the Lahn river landscape, Germany. Our framework relates to three key criteria that define NBS, and consists of six steps of planning: Co-define setting, Understand challenges, Create visions and scenarios, Assess potential impacts, Develop solution strategies, and Realize and monitor. Its implementation is guided by five principles, namely Place-specificity, Evidence base, Integration, Equity, and Transdisciplinarity. Drawing on the empirical insights from the case study, we suggest suitable methods and a checklist of supportive procedures for applying the framework in practice. Taken together, our framework can facilitate planning NBS and provides further steps towards mainstreaming.Electronic supplementary materialThe online version of this article (10.1007/s13280-020-01365-1) contains supplementary material, which is available to authorized users. 相似文献
As indoor smoking bans have become widely adopted, some U.S. communities are considering restricting smoking outdoors, creating a need for measurements of air pollution near smokers outdoors. Personal exposure experiments were conducted with four to five participants at six sidewalk bus stops located 1.5–3.3 m from the curb of two heavily traveled California arterial highways with 3300–5100 vehicles per hour. At each bus stop, a smoker in the group smoked a cigarette. Gravimetrically calibrated continuous monitors were used to measure fine particle concentrations (aerodynamic diameter ≤2.5 µm; PM2.5) in the breathing zones (within 0.2 m from the nose and mouth) of each participant. At each bus stop, ultrafine particles (UFP), wind speed, temperature, relative humidity, and traffic counts were also measured. For 13 cigarette experiments, the mean PM2.5 personal exposure of the nonsmoker seated 0.5 m from the smoker during a 5-min cigarette ranged from 15 to 153 µg/m3. Of four persons seated on the bench, the smoker received the highest PM2.5 breathing-zone exposure of 192 µg/m3. There was a strong proximity effect: nonsmokers at distances 0.5, 1.0, and 1.5 m from the smoker received mean PM2.5 personal exposures of 59, 40, and 28 µg/m3, respectively, compared with a background level of 1.7 µg/m3. Like the PM2.5 concentrations, UFP concentrations measured 0.5 m from the smoker increased abruptly when a cigarette started and decreased when the cigarette ended, averaging 44,500 particles/cm3 compared with the background level of 7200 particles/cm3. During nonsmoking periods, the UFP background concentrations showed occasional peaks due to traffic, whereas PM2.5 background concentrations were extremely low. The results indicate that a single cigarette smoked outdoors at a bus stop can cause PM2.5 and UFP concentrations near the smoker that are 16–35 and 6.2 times, respectively, higher than the background concentrations due to cars and trucks on an adjacent arterial highway.
Implications: Rules banning smoking indoors have been widely adopted in the United States and in many countries. Some communities are considering smoking bans that would apply to outdoor locations. Although many measurements are available of pollutant concentrations from secondhand smoke at indoor locations, few measurements are available of exposure to secondhand smoke outdoors. This study provides new data on exposure to fine and ultrafine particles from secondhand smoke near a smoker outdoors. The levels are compared with the exposure measured next to a highway. The findings are important for policies that might be developed for reducing exposure to secondhand smoke outdoors.相似文献
The current lack of empirical data on outdoor tobacco smoke (OTS) levels impedes OTS exposure and risk assessments. We sought to measure peak and time-averaged OTS concentrations in common outdoor settings near smokers and to explore the determinants of time-varying OTS levels, including the effects of source proximity and wind. Using five types of real-time airborne particle monitoring devices, we obtained more than 8000 min worth of continuous monitoring data, during which there were measurable OTS levels. Measurement intervals ranged from 2 sec to 1 min for the different instruments. We monitored OTS levels during 15 on-site visits to 10 outdoor public places where active cigar and cigarette smokers were present, including parks, sidewalk cafés, and restaurant and pub patios. For three of the visits and during 4 additional days of monitoring outdoors and indoors at a private residence, we controlled smoking activity at precise distances from monitored positions. The overall average OTS respirable particle concentration for the surveys of public places during smoking was approximately 30 microg m(-3). OTS exhibited sharp spikes in particle mass concentration during smoking that sometimes exceeded 1000 microg m(-3) at distances within 0.5 m of the source. Some average concentrations over the duration of a cigarette and within 0.5 m exceeded 200 microg m(-3), with some average downwind levels exceeding 500 microg m(-3). OTS levels in a constant upwind direction from an active cigarette source were nearly zero. OTS levels also approached zero at distances greater than approximately 2 m from a single cigarette. During periods of active smoking, peak and average OTS levels near smokers rivaled indoor tobacco smoke concentrations. However, OTS levels dropped almost instantly after smoking activity ceased. Based on our results, it is possible for OTS to present a nuisance or hazard under certain conditions of wind and smoker proximity. 相似文献
The transition of Estonia from the fragmented character of environmental protection activities of the former Estonian SSR to a centralised national environmental monitoring program is underway. Estonian Environment Information Centre (EEIC) performed as a main developer of the Estonian Monitoring Program (EMP) structure, coordinates the operation of about 60 subprogrammes of EMP. 相似文献
Residential interior door positions influence the pollutant concentrations that result from short-term indoor sources, such as cigarettes, candles, and incense. To elucidate this influence, we reviewed past studies and conducted new experiments in three residences: a single-story 714 m3 ranch-style house, a 510 m3 two-story split-level house, and a 200 m3 two-story house. During the experiments, we released sulfur hexafluoride or carbon monoxide tracer gas over short periods (≤30 min) and measured concentrations in the source room and at least one other (receptor) room for various interior door opening positions. We found that closing a door between rooms effectively prevented transport of air pollutants, reducing the average concentration in the receptor room relative to the source room by 57–100% over exposure periods of 1–8 h. When intervening doors were partially or fully open, the reduction in average concentrations ranged from 3% to 99%, varying as a function of door opening width and the distance between source and receptor rooms. 相似文献
Estonia still has no waste incineration facilities, which would act as substantial sources of dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) pollution. As landfill fires may serve as sources of dioxins, we focused on the concentrations of PCDD and PCDF in soil samples taken in the vicinity of the landfill located at south-east Estonia in the course of our inventory. Concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) were studied in five soil samples taken in the vicinity of the Laguja landfill in south-east Estonia. The four soil samples were taken in southern, eastern, western and northern parts not further than 300 m from the landfill, and one sample was taken at the distance of 3 km from the landfill. The PCDD/F concentrations in all soil samples were at background level (0.64-2.33 pg I-TEQ WHO/g dry weight). To maintain this situation, the administrator of the landfill must avoid landfill fires, which are one of the reasons for the generation of dioxins and furans. 相似文献
The aim of this paper is to examine the patterns of polychlorinated biphenyls (PCB) in the grey seals (Halichoerus grypus) from the Baltic, Northeast and Eastern England, and the St. Lawrence Estuary (Canada). In fact, the feeding habits of the ringed seal (Phoca hispida) include ingestion of major quantities of benthic crustaceans that might cause observed differences obtained in PCBs, whereas the grey seal feed mainly on fish. The profile (percent in mixture) of polychlorinated biphenyls (PCB) 101, 118, 138, 153, and 180, and the total of their concentrations in mg/kg lipid in grey seals from the Baltic, from Northeast and Eastern England, and from the St. Lawrence estuary (Canada), were examined by principal component analysis (PCA). When considering the possible effects of consuming seafood by the grey seal, it is necessary to characterize populations and individuals according to the amounts they consume, since populations in different parts of the world are likely to show big differences in their consumption of seafood. The patterns differ between juveniles and adult animals, but the gender of adults and geography do not appear to play a role. 相似文献
Personal exposure to air pollutants can be substantially higher in close proximity to an active source due to non-instantaneous mixing of emissions. The research presented in this paper quantifies this proximity effect for a non-buoyant source in 2 naturally ventilated homes in Northern California (CA), assessing its spatial and temporal variation and the influence of factors such as ventilation rate on its magnitude. To quantify how proximity to residential sources of indoor air pollutants affects human exposure, we performed 16 separate monitoring experiments in the living rooms of two detached single-family homes. CO (as a tracer gas) was released from a point source in the center of the room at a controlled emission rate for 5-12 h per experiment, while an array of 30-37 real-time monitors simultaneously measured CO concentrations with 15 s time resolution at radial distances ranging from 0.25-5 m under a range of ventilation conditions. Concentrations measured in close proximity (within 1 m) to the source were highly variable, with 5 min averages that typically varied by >100-fold. This variability was due to short-duration (<1 min) pollutant concentration peaks ("microplumes") that were frequently recorded in close proximity to the source. We decomposed the random microplume component from the total concentrations by subtracting predicted concentrations that assumed uniform, instantaneous mixing within the room and found that these microplumes can be modeled using a 3-parameter lognormal distribution. Average concentrations measured within 0.25 m of the source were 6-20 times as high as the predicted well-mixed concentrations. 相似文献
Investigators In different environmental fields have reported that the concentrations of various measured substances have frequency distributions that are lognormal, or nearly so. That is, when the logarithms of the observed concentrations are plotted as a frequency distribution, the resulting distribution is approximately normal, or Gaussian, over much of the observed range. Examples include radionuclides in soil, pollutants in ambient air, Indoor air quality, trace metals In streams, metals in biological tissue, calcium In human remains. The ubiquity of the lognormal distribution in environmental processes is surprising and has not been adequately explained, since common processes in nature (for example, computation of the mean and the analysis of error) usually give rise to distributions that are normal rather than lognormal. This paper takes the first step toward explaining why lognormal distributions can arise naturally from certain physical processes that are analogous to those found in the environment. In this paper, these processes are treated mathematically, and the results are illustrated in a laboratory beaker experiment that Is simulated on the computer. 相似文献
Carbon monoxide (CO) exposures were measured inside a motor vehicle during 88 standardized drives on a major urban arterial highway, El Camino Real (traffic volume of 30,500-45,000 vehicles per day), over a 13-1/2 month period. On each trip (lasting between 31 and 61 minutes), the test vehicle drove the same 5.9-mile segment of roadway in both directions, for a total of 11.8 miles, passing through 20 intersections with traffic lights (10 in each direction) in three California cities (Menlo Park, Palo Alto, and Los Altos). Earlier tests showed that the test vehicle was free of CO intrusion. For the 88 trips, the mean CO concentration was 9.8 ppm, with a standard deviation of 5.8 ppm. Of nine covariates that were examined to explain the variability in the mean CO exposures observed on the 88 trips (ambient CO at two fixed stations, atmospheric stability, seasonal trend function, time of day, average surrounding vehicle count, trip duration, proportion of time stopped at lights, and instrument type), a fairly strong seasonal trend was found. A model consisting of only a single measure of traffic volume and a seasonal trend component had substantial predictive power (R2 = 0.68); by contrast, the ambient CO levels, although partially correlated with average exposures, contributed comparatively little predictive power to the model. The CO exposures experienced while drivers waited at the red lights at an intersection ranged from 6.8 to 14.9 ppm and differed considerably from intersection to intersection. A model also was developed to relate the short-term variability of exposures to averaging time for trip times ranging from 1 to 20 minutes using a variogram approach to deal with the serial autocorrelation. This study shows: (1) the mass balance equation can relate exterior CO concentrations as a function of time to interior CO concentrations; (2) CO exposures on urban arterial highways vary seasonally; (3) momentary CO exposures experienced behind red lights vary with the intersection; and (4) an averaging time model can simulate exposures during short trips (20 minutes or less) on urban arterial highways. 相似文献