排序方式: 共有7条查询结果,搜索用时 15 毫秒
1
1.
以旋转填充床(RPB)作为反应装置,研究了Fenton工艺与Fenton+O3工艺处理模拟阿莫西林废水的效果,考察了FeSO4·7H2O的投加量、温度、旋转床转速、液体流量及pH对C0D去除率的影响。实验表明,Fenton+O3工艺的COD脱除率及BOD5/COD相对于Fenton工艺分别提升26.7%和140%。该工艺在pH为3、温度为25℃、液体流量30L/h、气体流量2.5L/h、转速800r/min、H2O2的投加量为1mmol/L及Fe2+投加量为0.4mm01/L的条件下,100mg/L的模拟阿莫西林废水中COD的去除率达到57.9%,BOD5/COD从0增加到0.36,满足后续生化处理要求。 相似文献
2.
Ozonation of azo dye Acid Red 14 in a microporous tube-in-tube microchannel reactor: decolorization and mechanism 总被引:1,自引:0,他引:1
Despite the great success of time-weighted average passive sampling of hydrophobic contaminants, such as PCBs and PAHs, the sampling of polar organic compounds still presents a challenge because the equilibrium between water and most sampling phases is attained in a relatively short time. In this study, we proposed a new time-integrative sampler using in situ solvent extraction (TISIS) for polar organic chemicals. The sampler was composed of a 15 cm poly(dimethylsiloxane) (PDMS) tubing, with an internal diameter of 0.5 mm and wall thickness of 0.5 mm, through which an extraction solvent (acetonitrile) was passed. Four polar organic contaminants, caffeine, atrazine, diuron and 17α-ethynylestradiol, were chosen for the evaluation of the performance of the sampler. Without the use of in situ solvent extraction, the PDMS tubing when exposed to a constant aqueous concentration of the four model compounds was able to linearly accumulate those compounds for less than 12 h and equilibrium between the PDMS tubing and water was attained in 2 d under our laboratory conditions. However, TISIS when exposed to a constant aqueous concentration was able to linearly accumulate all the model compounds without any exposure time limitation. The measured sampling rates at three different extraction flow rates (0.2, 0.5, 1.5 mL min−1) were similar, regardless of the chemicals, indicating that the overall mass transfer from aqueous solution to the extraction solvent was most likely dominated by partitioning to the PDMS tubing and the internal diffusion within PDMS. In addition, a pulsed exposure experiment confirmed that TISIS operated in a time-integrative mode when the environmental concentration was highly fluctuated. 相似文献
3.
4.
5.
以旋转填充床(RPB)作为反应装置,研究了Fenton工艺与Fenton+O3工艺处理模拟阿莫西林废水的效果,考察了FeSO4·7H2O的投加量、温度、旋转床转速、液体流量及pH对COD去除率的影响。实验表明,Fenton+O3工艺的COD脱除率及BOD5/COD相对于Fenton工艺分别提升26.7%和140%。该工艺在pH为3、温度为25℃、液体流量30 L/h、气体流量2.5 L/h、转速800 r/min、H2O2的投加量为1 mmol/L及Fe2+投加量为0.4 mmol/L的条件下,100 mg/L的模拟阿莫西林废水中COD的去除率达到57.9%,BOD5/COD从0增加到0.36,满足后续生化处理要求。 相似文献
6.
7.
1