排序方式: 共有43条查询结果,搜索用时 15 毫秒
1.
Comprehensive temperature monitoring in an in-vessel forced-aeration static-bed composting process 总被引:6,自引:0,他引:6
Masafumi Tateda Le Duc Trung Nguyen Viet Hung Michihiko Ike Masanori Fujita 《Journal of Material Cycles and Waste Management》2002,4(1):62-69
Comprehensive temperature monitoring was done in an in-vessel forced-aeration static-bed composting process using sewage sludge.
The three layers that divided the compost pile horizontally showed different temperature distributions. The temperature of
the top layer appeared not to be influenced by the ambient temperature. The temperature of the center area of the top layer
was taken to be the representative temperature for evaluating composting start-up performance. The temperature of the bottom
layer was strongly influenced by the ambient temperature, and the temperature of the center area of the bottom layer was taken
to be the representative temperature for pathogen control as it was the minimum temperature in the reactor. Composting start-up
performance was influenced by several factors when the ambient temperature was either below or above 20°C. When the ambient
temperature was below 20°C, the time taken to reach 65°C (T
65) was influenced by the temperature of inflowing air, but when the temperature was higher than 20°C, it was influenced by
the ratio of sewage sludge to seed compost (F/S). T
65 was least when F/S was 1–2.
Received: January 9, 2001 / Accepted: October 10, 2001 相似文献
2.
Contamination of groundwater and risk assessment for arsenic exposure in Ha Nam province, Vietnam 总被引:2,自引:0,他引:2
The characteristics of arsenic-contaminated groundwater and the potential risks from the groundwater were investigated. Arsenic contamination in groundwater was found in four villages (Vinh Tru, Bo De, Hoa Hau, Nhan Dao) in Ha Nam province in northern Vietnam. Since the groundwater had been used as one of the main drinking water sources in these regions, groundwater and hair samples were collected in the villages. The concentrations of arsenic in the three villages (Vinh Tru, Bo De, Hoa Hau) significantly exceeded the Vietnamese drinking water standard for arsenic (10 microg/L) with average concentrations of 348, 211, and 325 microg/L, respectively. According to the results of the arsenic speciation testing, the predominant arsenic species in the groundwater existed as arsenite [As(III)]. Elevated concentrations of iron, manganese, and ammonium were also found in the groundwater. Although more than 90% of the arsenic was removed by sand filtration systems used in this region, arsenic concentrations of most treated groundwater were still higher than the drinking water standard. A significant positive correlation was found between the arsenic concentrations in the treated groundwater and in female human hair. The risk assessment for arsenic through drinking water pathways shows both potential chronic and carcinogenic risks to the local community. More than 40% of the people consuming treated groundwater are at chronic risk for arsenic exposure. 相似文献
3.
Ester Heath Marjeta Česen Noelia Negreira Miren Lopez de Alda Laura Ferrando-Climent Lucie Blahova Tung Viet Nguyen Mohamed Adahchour Achim Ruebel Neville Llewellyn Janez Ščančar Srdjan Novaković Vesna Mislej Marjeta Stražar Damià Barceló Tina Kosjek 《Environmental science and pollution research international》2016,23(15):14692-14704
The results of an inter-laboratory comparison exercise to determine cytostatic anticancer drug residues in surface water, hospital wastewater and wastewater treatment plant effluent are reported. To obtain a critical number of participants, an invitation was sent out to potential laboratories identified to have the necessary knowledge and instrumentation. Nine laboratories worldwide confirmed their participation in the exercise. The compounds selected (based on the extent of use and laboratories capabilities) included cyclophosphamide, ifosfamide, 5-fluorouracil, gemcitabine, etoposide, methotrexate and cisplatinum. Samples of spiked waste (hospital and wastewater treatment plant effluent) and surface water, and additional non-spiked hospital wastewater, were prepared by the organising laboratory (Jo?ef Stefan Institute) and sent out to each participant partner for analysis. All analytical methods included solid phase extraction (SPE) and the use of surrogate/internal standards for quantification. Chemical analysis was performed using either liquid or gas chromatography mass (MS) or tandem mass (MS/MS) spectrometry. Cisplatinum was determined using inductively coupled plasma mass spectrometry (ICP-MS). A required minimum contribution of five laboratories meant that only cyclophosphamide, ifosfamide, methotrexate and etoposide could be included in the statistical evaluation. z-score and Q test revealed 3 and 4 outliers using classical and robust approach, respectively. The smallest absolute differences between the spiked values and the measured values were observed in the surface water matrix. The highest within-laboratory repeatability was observed for methotrexate in all three matrices (CV?≤?12 %). Overall, inter-laboratory reproducibility was poor for all compounds and matrices (CV 27–143 %) with the only exception being methotrexate measured in the spiked hospital wastewater (CV?=?8 %). Random and total errors were identified by means of Youden plots. 相似文献
4.
Shin Takahashi Nguyen Minh Tue Chika Takayanagi Le Huu Tuyen Go Suzuki Hidenori Matsukami Pham Hung Viet Tatsuya Kunisue Shinsuke Tanabe 《Journal of Material Cycles and Waste Management》2017,19(4):1333-1341
Floor dusts from Vietnamese end-of-life vehicle (ELV)-processing households were investigated to elucidate the contamination levels and exposure risk of polychlorinated biphenyls (PCBs), polybrominated diphenyl ethers (PBDEs) and dioxin-related compounds (DRCs). The concentrations were in order of PBDEs (260–11,000, median 280 ng/g overall) > PCBs (19–2200, median 140 ng/g) > dioxin-like PCBs (8.8–450, median 22 ng/g) ? polybrominated dibenzo-p-dioxin/dibenzofurans (PBDD/Fs, 2000–28,000, median 8500 pg/g) > polychlorinated dibenzo-p-dioxin/dibenzofurans (PCDD/Fs, 440–4100, median 1800 pg/g) > MoBPCDD/Fs (1.9–1200, median 250 pg/g). Concentrations of PCBs and DRCs were higher than those reported for Vietnamese urban houses, indicating ELV processing as a significant source of these contaminants. Higher concentrations of PCBs relative to PBDEs suggest the abundance of old electrical capacitors/transformers in ELVs. The PBDD/F and PCDD/F profiles were indicative of DecaBDE-containing materials and combustion sources, respectively. PBDFs, PCDFs and DL-PCBs were the most important dioxin-like toxic equivalent (TEQ) contributors. The estimated PCB and TEQ intake doses from dust ingestion approached or exceeded the reference doses for children living in some ELV-processing households, indicating potential health risk. More comprehensive risk assessment of the exposure to PCBs and DRCs is required for residents of informal ELV recycling sites. 相似文献
5.
6.
The 2011 flood event in the Mekong Delta: preparedness,response, damage and recovery of private households and small businesses 下载免费PDF全文
Floods frequently cause substantial economic and human losses, particularly in developing countries. For the development of sound flood risk management schemes that reduce flood consequences, detailed insights into the different components of the flood risk management cycle, such as preparedness, response, flood impact analyses and recovery, are needed. However, such detailed insights are often lacking: commonly, only (aggregated) data on direct flood damage are available. Other damage categories such as losses owing to the disruption of production processes are usually not considered, resulting in incomplete risk assessments and possibly inappropriate recommendations for risk management. In this paper, data from 858 face‐to‐face interviews among flood‐prone households and small businesses in Can Tho city in the Vietnamese Mekong Delta are presented to gain better insights into the damage caused by the 2011 flood event and its management by households and businesses. 相似文献
7.
Sorption of biodegradation end products of nonylphenol polyethoxylates onto activated sludge 总被引:3,自引:1,他引:3
Nguyen Viet Hung Masafumi Tate Michihiko Ike Masanori Fujit Shinji Tsunoi Minoru Tanaka 《环境科学学报(英文版)》2004,16(4):564-569
IntroductionRecently ,nonylphenolpolyethoxylates (NPnEO (n :numberofethoxyunits(EOs) )havebecomeaproblematicissueforthereasonthatthesecompounds,animportantgroupofnonionicsurfactants ,havebeenusedwidelyinvariousindustriesasflocculants,dispersants,emulsifie… 相似文献
8.
不同来源腐殖酸的光解及过氧化氢对其影响 总被引:7,自引:0,他引:7
为探讨腐殖酸在环境中的行为及光解除去腐殖酸的可能性,利用大于290nm的模拟日光辐照,探讨了大骨节病病区、非病区腐殖酸和泥炭腐殖酸的光解过程和光解机理及过氧化氢对其光解的影响,发现随着光照时间的延长,腐殖酸水体系的总有机碳(TOC)含量降低,pH值下降,过氧化氢可以促进腐殖酸的光解,其光解过程遵循一级动力学规律。计算了不同来源腐殖酸光解的速率及光解半衰期,发现土壤和泥炭腐殖酸比大骨节病病区饮水中腐 相似文献
9.
Huy Tran Hong Phat Bui Dai Thi Cao Minh Van Viet Pham 《Environmental Chemistry Letters》2019,17(1):527-531
Environmental Chemistry Letters - Tin oxide nanoparticles (SnO2 NPs) with a diameter less than 10 nm are usually used in waste water treatment via the photocatalytic reaction. However,... 相似文献
10.
Hirokazu Ozaki Thi Kinh Co Anh Kha Le Viet Nu Pham Van Be Nguyen Mitsunori Tarao Huu Chiem Nguyen Viet Dung Le Hieu Trung Nguyen Masaki Sagehashi Sachi Ninomiya-Lim Takashi Gomi Masaaki Hosomi Hideshige Takada 《Environmental monitoring and assessment》2014,186(2):845-858
In this study, we focused on water quality in an urban canal and the Mekong River in the city of Can Tho, a central municipality of the Mekong Delta region, southern Vietnam. Water temperature, pH, electrical conductivity, BOD5, CODCr, Na+, Cl?, NH4 +?N, SO4 2??S, NO3 ??N, and NO2 ??N for both canal and river, and tide level of the urban canal, were monitored once per month from May 2010 to April 2012. The urban canal is subject to severe anthropogenic contamination, owing to poor sewage treatment. In general, water quality in the canal exhibited strong tidal variation, poorer at lower tides and better at higher tides. Some anomalies were observed, with degraded water quality under some high-tide conditions. These were associated with flow from the upstream residential area. Therefore, it was concluded that water quality in the urban canal changed with a balance between dilution effects and extent of contaminant supply, both driven by tidal fluctuations in the Mekong River. 相似文献