首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   100篇
  免费   2篇
  国内免费   1篇
安全科学   1篇
废物处理   6篇
环保管理   8篇
综合类   15篇
基础理论   14篇
污染及防治   43篇
评价与监测   10篇
社会与环境   5篇
灾害及防治   1篇
  2023年   2篇
  2022年   6篇
  2021年   9篇
  2020年   1篇
  2019年   2篇
  2018年   4篇
  2017年   8篇
  2016年   7篇
  2015年   2篇
  2014年   10篇
  2013年   8篇
  2012年   7篇
  2011年   8篇
  2010年   4篇
  2009年   4篇
  2008年   6篇
  2007年   2篇
  2006年   4篇
  2005年   3篇
  2004年   1篇
  2001年   2篇
  1994年   1篇
  1989年   1篇
  1987年   1篇
排序方式: 共有103条查询结果,搜索用时 781 毫秒
11.
Esmoriz–Paramos lagoon is an ecosystem of great ecological importance that is located on the northwest coast of Portugal and has been degraded as a result of industrial and anthropogenic activities. Concentrations of heavy metals (Cr, Cu, Pb and Zn) were measured in water, sediment and in tissues (liver and muscle) of Liza saliens, which is the dominant fish from the lagoon. Comparisons between metal concentrations in water and sediments were made with those in tissues of fish caught at the lagoon. Metals in water were quantified predominantly bound to particulate and equalled or exceeded the limit of chronic reference values. Metal concentrations in sediments varied among sampled sites. The relative order of concentrations was “Zn > Cu ∼ Pb > Cr” the same pattern observed for metals in water. Metals in fish tissues showed higher concentrations in liver (262 mg Cu·Kg−1 and 89 mg Zn·Kg−1) than in muscle (<3 mg Cu·Kg−1 and 26 mg Zn·Kg−1), while Pb and Cr were not detected. These results suggest that Cu and Zn are the metals of major concern in the lagoon. Mullet detritivorous feeding habits, bioaccumulation pattern and the high sediment metals concentrations relative to the water suggest that sediments can be the most important source of contamination in this ecosystem. The positive relationship found between Cu in liver and fish length demonstrates that time of exposure is a crucial factor in bioaccumulation. Condition indices (K and HSI) in mullets from the lagoon were higher compared to mullets from sea, suggesting abnormal condition in the lagoon population. We conclude that metals chronic exposure in the lagoon can impose considerable fish stress. The results also show that the lagoon is an area of environmental concern.  相似文献   
12.
In this study, an analysis was performed on the concentrations of the trace elements Al, As, Ba, Cd, Co, Cr, Cu, Fe, Mn, Ni, Pb, V, and Zn in muscle of two carnivorous and one planktivorous fish species collected at Todos os Santos Bay (BTS). The accumulation order of the trace elements in Lutjanus analis was Al >Zn >Fe >Cr >Ba >Ni. In Cetengraulis edentulus, the order was Al >Fe >Zn >Cr >Ni >Mn >As. In the species Diapterus rhombeus, the order was Al >Fe >Zn >Cr >Ni >Mn >Cd. To determine the risk related to the consumption of fish, toxicity guidelines were used as standard references. It was observed that the species C. edentulus contained concentrations of As exceeding WHO limits, but these concentrations were acceptable according to the Agência Nacional de Vigilância Sanitária (ANVISA) guidelines. Cd levels were found only in D. rhombeus and in low concentrations according to the determinations of WHO and ANVISA. Pb levels were not detected in any of the three fish species. The analyzed elements did not differ statistically according to the species and feeding habits. The results point to possible risks of human contamination by As related to the consumption of the fish species C. edentulus from the BTS.  相似文献   
13.
The concentrations of seven metals (Cd, Cr, Cu, Fe, Mn, Ni and Zn) were determined in coastal seawaters and soft and hard tissues of the barnacle Chthamalus montagui from the northwest coast of Portugal to assess the potential use of C. montagui as biomonitor of metal contamination. The results of this study showed that C. montagui soft tissues can be used for monitoring metal bioavailabilities in these coastal seawaters: (1) there were significant correlations (p?相似文献   
14.
The main objective of this work was to assess the potential use of goose barnacle Pollicipes pollicipes as biomonitor of metal contamination in northwest (NW) coast of Portugal. The concentrations of Cd, Cr, Cu, Fe, Mn, Ni and Zn were determined in coastal seawaters and tissues of P. pollicipes, which allowed establishing correlations between metals in coastal seawaters and P. pollicipes and calculating metal bioaccumulation factors (BAFs). The results of this study showed that P. pollicipes soft tissues can be used for monitoring metal contamination in these coastal seawaters: (1) there were significant correlations (p??0.05); (2) soft tissues were sensitive to spatial variations of metal bioavailabilities and their concentrations ranged 0.70-2.22?mg?Cd?kg(-1), 0.49-1.40?mg?Cr?kg(-1), 1.37-2.07?mg?Ni?kg(-1), 2.4-3.3?mg?Cu?kg(-1), 5-59?mg?Mn?kg(-1), 134-578?mg?Fe?kg(-1)and 728-1,854?mg?Zn?kg(-1); (3) mean logarithmic bioaccumulation factors (log BAF) of Fe, Cd and Zn were higher, 5.57, 5.47 and 4.41, respectively, than mean log BAFs of Cr, Mn, Cu and Ni, 4.18, 4.14, 3.98 and 3.51, respectively. In contrary, P. pollicipes shell plates were not considered ideal material to monitor metal bioavailabilities in these coastal seawaters. Regarding the very high concentrations of Zn obtained in the coastal seawaters and P. pollicipes soft tissues, the NW coast of Portugal should be classified as "Class III/IV - Remarkably/Highly Polluted".  相似文献   
15.
Determining the electromagnetic radiation levels in urban areas is a complicated task. Various approaches have been taken, including numerical simulations using different models of propagation, sampling campaigns to measure field values with which to validate theoretical models, and the formalism of spatial statistics. In the work, we present here that this latter technique was used to construct maps of electric field and its associated uncertainty from experimental data. For this purpose, a field meter and a broadband probe sensitive in the 100-kHz–3-GHz frequency range were used to take 1,020 measurements around buildings and along the perimeter of the area. The distance between sampling points was 5 m. The results were stored in a geographic information system to facilitate data handling and analysis, in particular, the application of the formalism of spatial statistical to the analysis of the distribution of the field levels over the study area. The spatial structure was analyzed using the variographic technique, with the field levels at non-sampled points being interpolated by kriging. The results indicated that, in the urban area analyzed in the present work, the linear density of sampling points could be reduced to a distance which coincides with the length of the blocks of buildings without the statistical parameters varying significantly and with the field level maps being reproduced qualitatively and quantitatively.  相似文献   
16.
We studied the short- and medium-term effects of experimental nitrogen fertilization (3 and 15 months after the treatment) on the arthropods of Calluna vulgaris heathlands in NW Spain. Three heathland sites were selected with two permanent plots per site: control and fertilized. Ammonium nitrate fertilizer (56 kg N ha(-1) yr(-1)) was applied monthly and insects were caught using pitfall traps. We found mainly species-level responses to nitrogen addition. Seven species (e.g. Lochmaea suturalis) showed a consistent trend (benefited or harmed) in both periods and were proposed as possible reliable indicators of the effects of nitrogen deposition in these ecosystems. We also found variable arthropod trophic-group responses: (a) herbivores (leaf beetles, true bugs) increased in abundance on a short-term scale; (b) predators (carabid beetles, true bugs) showed opposite and less clear responses in both periods. Further long-term studies are needed to determine the mechanisms underlying the observed arthropod responses.  相似文献   
17.
The effect of an oxidative co-treatment on anaerobic digestion of a mixture of primary and waste activated sludge was investigated. The oxidant used in this study was hydrogen peroxide (H2O2). A maximum improvement in solid destruction of 15.2% was achieved in the overall process, with a dosage of 2.0 g H2O2/g influent volatile suspended solids (VSS(influent)). All configurations operated at this dosage also showed statistically significant increases in solids removal. A statistically significant enhancement in overall solids destruction was observed for the lower oxidant dosage (0.5 H2O2/g VSS(influent)). Surprisingly, for 1.0 g H2O2/g VSS(influent), only one of the three configurations involving oxidative co-treatment showed significant increases in solids destruction. Special attention was paid to the performance of this process relative to fecal coliforms destruction. Class A biosolids were obtained for all the different hydrogen peroxide dosages used when oxidative co-treatment is combined with a two-stage anaerobic digestion process.  相似文献   
18.
Fixed-bed column studies were carried out to investigate the dynamic sorption of Reactive Black 5 (RB5) onto chitosan. The effect of operating parameters such as initial dye concentration, superficial flow velocity, bed height and particle size on the sorption of RB5 onto chitosan was studied. Column regeneration, dye recovery and the possibility of reusing the regenerated chitosan were also investigated. The results show that both the breakthrough curves and the adsorption parameters of the column were strongly affected by the operating parameters studied. An analysis of the breakthrough curves indicated that adsorption was affected by mass transfer limitations, probably due to intraparticle diffusion. An empirical model was applied to describe the breakthrough curves, while the Bohart–Adams and BDST models were used to determine the operating parameters useful in the process design. Elution of the column with 0.01 mol L?1 NaOH allowed the chitosan to be regenerated and the dye to be recovered and concentrated. The concentration factor was 10. Several cycles of adsorption–elution showed that the regenerated chitosan retained good adsorption efficiency and the elution efficiency was always higher than 80%.  相似文献   
19.
A rapid, sensitive, accurate and reliable multiresidue method for the identification and quantification of 210 relevant pesticides in four representative fruit and vegetable commodities (tomato, potato, spring onion and orange) has been developed and validated by gas chromatography in tandem with triple quadrupole mass spectrometry. The method has been fully validated and applied to 292 samples from different countries. Prior to instrumental analysis, an extraction procedure based on a sample extraction of multiclass analytes, using the ethyl acetate method was employed. Mass spectrometric conditions were individually optimized for each compound in the selected reaction monitoring (SRM) mode to achieve maximum sensitivity. The pesticides were separated in less than 25 min. This was followed by an exhaustive control of the retention times. The Retention Time Locking Method was applied, working at a constant pressure throughout the analysis. System maintenance was reduced by using a purged capillary flow device that provided backflush capabilities by reversing column flow immediately after elution of the last compound of interest. Istotopically labelled internal standards were employed to improve the quality of the analytical results.  相似文献   
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号