• Pig feces is the predominant excrement produced by animal husbandry in China.• The PF, Pig-1-BacTaqMan, and Pig-2-BacTaqMan MST assays showed better performance.• The pig-specific MST assays can contribute to managing the pig fecal pollution. In China, pig feces is the predominant source of excrement produced by animal husbandry. Improper use or direct discharge of pig feces can result in contamination of natural water systems. Microbial source tracking (MST) technology can identify the sources of fecal pollution in environmental water, and contribute to the management of pig fecal pollution by local environmental protection agencies. However, the accuracy of such assays can be context-dependent, and they have not been comprehensively evaluated under Chinese conditions. We aimed to compare the performance of five previously reported pig-specific MST assays (PF, Pig-Bac1SYBR, Pig-Bac2SYBR, Pig-1-BacTaqMan, and Pig-2-BacTaqMan, which are based on Bacteroidales 16S rRNA gene markers) and apply them in two rivers of North China. We collected a total of 173 fecal samples from pigs, cows, goats, chickens, humans, and horses across China. The PF assay optimized in this study showed outstanding qualitative performance and achieved 100% specificity and sensitivity. However, the two SYBR green qPCR assays (Pig-Bac1SYBR and Pig-Bac2SYBR) cross-reacted with most non-pig fecal samples. In contrast, both the Pig-1-BacTaqMan and Pig-2-BacTaqMan assays gave 100% specificity and sensitivity. Of these, the Pig-2-BacTaqMan assay showed higher reproducibility. Our results regarding the specificity of these pig-specific MST assays differ from those reported in Thailand, Japan, and America. Using the PF and Pig-2-BacTaqMan assays, a field test comparing the levels of pig fecal pollution in rivers near a pig farm before and after comprehensive environmental pollution governance indicated that pig fecal pollution was effectively controlled at this location. 相似文献
• Effects of metabolic uncoupler TCS on the performances of GDMBR were evaluated.• Sludge EPS reduced and transformed into dissolved SMP when TCS was added.• Appropriate TCS increased the permeability and reduced cake layer fouling.• High dosage aggravated fouling due to compact cake layer with low bio-activity. The gravity-driven membrane bioreactor (MBR)system is promising for decentralized sewage treatment because of its low energy consumption and maintenance requirements. However, the growing sludge not only increases membrane fouling, but also augments operational complexities (sludge discharge). We added the metabolic uncoupler 3,3′,4′,5-tetrachlorosalicylanilide (TCS) to the system to deal with the mentioned issues. Based on the results, TCS addition effectively decreased sludge ATP and sludge yield (reduced by 50%). Extracellular polymeric substances (EPS; proteins and polysaccharides) decreased with the addition of TCS and were transformed into dissolved soluble microbial products (SMPs) in the bulk solution, leading to the break of sludge flocs into small fragments. Permeability was increased by more than two times, reaching 60–70 L/m2/h bar when 10–30 mg/L TCS were added, because of the reduced suspended sludge and the formation of a thin cake layer with low EPS levels. Resistance analyses confirmed that appropriate dosages of TCS primarily decreased the cake layer and hydraulically reversible resistances. Permeability decreased at high dosage (50 mg/L) due to the release of excess sludge fragments and SMP into the supernatant, with a thin but more compact fouling layer with low bioactivity developing on the membrane surface, causing higher cake layer and pore blocking resistances. Our study provides a fundamental understanding of how a metabolic uncoupler affects the sludge and bio-fouling layers at different dosages, with practical relevance for in situ sludge reduction and membrane fouling alleviation in MBR systems. 相似文献
In this study, farmland and mining ecotypes of Solanum photeinocarpum (a potential cadmium (Cd) hyperaccumulator plant) were reciprocally hybridized each other, and the Cd accumulation characteristics of the F1 hybrids were studied. In pot experiments, higher biomasses and Cd extraction abilities were found for two S. photeinocarpum F1 hybrids than for the parents, but the Cd contents in various organs were lower in the hybrids than the parents. However, the differences between the Cd contents in the two hybrids were not significant. The antioxidant enzyme (superoxide dismutase and peroxidase) activities were higher for the S. photeinocarpum F1 hybrids than the parents. Less DNA methylation was found in the hybrids than the parents because more demethylation occurred in the hybrids than the parents. The biomass, Cd content, and Cd extraction ability effects in field experiments were similar to the effects in the pot experiments. It was concluded that reciprocally hybridizing different S. photeinocarpum ecotypes improved the ability of S. photeinocarpum to be used to phytoremediate contaminated land.
The Sanjiang Plain, the largest inland freshwater marshland in China, was extensive reclaimed into agricultural land. To assess the effects of marshland reclamation on Collembola, we investigated collembolan communities in a chronosequence of soybean plantations (2, 15, and 25 years) in Sanjiang marshland, Northeastern China. We found that: 1) the densities and species richness of Collembola were promoted after short-term (2 years) cultivation of soybean, but significantly decreased after medium-term cultivation (15 years); 2) the densities of epi-edaphic Collembola increased while the densities of hemi-edaphic Collembola decreased as the elongation of soybean cultivation; 3) compared with S0, two species of Collembola appeared while five species disappeared in S25. The changes of plant communities and the soil traits were supposed to be the key factors affecting the composition of soil Collembola. We thus suggest that original marshland should be saved for preserving high diversity and densities of Collembola in the Sanjiang Plain.
Hg emission flux from various land covers, such as forests, wetlands, and urban areas, have been investigated. China has the largest area of coalfield in the world, but data of Hg flux of coalfields, especially, those with coal fires, are seriously limited. In this study, Hg fluxes of a coalfield were measured using the dynamic flux chamber (DFC) method, coupled with a Lumex multifunctional Hg analyzer RA-915+ (Lumex Ltd., Russia). The results show that the Hg flux in Wuda coalfield ranged from 4 to 318 ng m?2 h?1, and the average value for different areas varied, e.g., coal-fire area 99 and 177 ng m?2 h?1; no coal-fire area 19 and 32 ng m?2 h?1; and backfilling area 53 ng m?2 h?1. Hg continued to be emitted from an underground coal seam, even if there were no phenomena, such as vents, cracks, and smog, of coal fire on the soil surface. This phenomenon occurred in all area types, i.e., coal-fire area, no coal-fire area, and backfilling area, which is universal in Wuda coalfield. Considering that many coalfields in northern China are similar to Wuda coalfield, they may be large sources of atmospheric Hg. The correlations of Hg emission flux with influence factors, such as sunlight intensity, soil surface temperature, and atmospheric Hg content, were also investigated for Wuda coalfield.
The interrelationships between ventilation rate, indoor air quality, and energy consumption in operation rooms at rest are yet to be understood. We investigate the effect of ventilation rate on indoor air quality indices and energy consumption in ORs at rest. The study investigates the air temperature, relative humidity, concentrations of carbon dioxide, particulate matter (PM), and airborne bacteria at different ventilation rates in operation rooms at rest of a medical center. The energy consumption and cost analysis of the heating, ventilating, and air conditioning (HVAC) system in the operation rooms at rest were also evaluated for all ventilation rates. No air-conditioned operation rooms had very highest PM and airborne bacterial concentrations in the operation areas. The bacterial concentration in the operation areas with 6–30 air changes per hour (ACH) was below the suggested level set by the United Kingdom (UK) for an empty operation room. A 70% of reduction in annual energy cost by reducing the ventilation rate from 30 to 6 ACH was found in the operation rooms at rest. Maintenance of operation rooms at ventilation rate of 6 ACH could save considerable amounts of energy and achieve the goal of air cleanliness. 相似文献