首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   124篇
  免费   1篇
  国内免费   6篇
安全科学   6篇
废物处理   11篇
环保管理   11篇
综合类   20篇
基础理论   17篇
污染及防治   48篇
评价与监测   15篇
社会与环境   1篇
灾害及防治   2篇
  2021年   3篇
  2020年   1篇
  2018年   3篇
  2017年   7篇
  2016年   4篇
  2015年   2篇
  2014年   9篇
  2013年   10篇
  2012年   13篇
  2011年   12篇
  2010年   5篇
  2009年   8篇
  2008年   6篇
  2007年   15篇
  2006年   10篇
  2005年   10篇
  2004年   3篇
  2003年   3篇
  2002年   4篇
  2001年   2篇
  1982年   1篇
排序方式: 共有131条查询结果,搜索用时 15 毫秒
111.
In a woman with a partial hydatidiform molar pregnancy with 69,XXY karyotype, the presence of male fetal cells of trophoblastic origin was demonstrated in maternal blood by X/Y-chromosome specific PCR and by immunostaining combined with FISH on two cell populations isolated from maternal blood. Blood was obtained three weeks prior to the detection of fetal demise, at 13 weeks' gestation. Results were confirmed on formalin-fixed paraffin-embedded molar tissue, removed at 16 weeks' gestational age for therapeutic reasons. The results indicate that both plasma and cells from maternal peripheral blood might be useful for non-invasive prenatal diagnosis of fetal aneuploidies, as described in the current case with a partial molar pregnancy. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   
112.
113.
114.
Environmental Science and Pollution Research - Pesticides are emergent toxins often identified in aquatic environments. In the present study, microplasma was employed to reduce the pesticide...  相似文献   
115.
116.
Simultaneous nitrification-denitrification (SND) of municipal wastewater was investigated in a laboratory-scale membrane bioreactor (MBR) operated at two different hydraulic retention times (HRTs), 0.5 and 1 day, dissolved oxygen 3.0 to 0.5 mg/L, and solids retention time (SRT) between 28 and 120 days. The organic loading rate (OLR) (0.11 to 0.64 kg chemical oxygen demand [COD]/m3/d) and influent soluble COD (SCOD)/ total Kjeldahl nitrogen (TKN) ratio (5 to 19) were varied by the addition of glucose. The ammonia-nitrogen and TKN removals were over 97%, and total nitrogen removal was approximately 89% in the MBR. The maximum specific nitrification rates (98 mg N/d/g VSS) and specific denitrification rates (81 mg N/d/g VSS) occurred at an SCOD/TKN ratio of 9.1. The optimum conditions for maximum total nitrogen removal by SND in a single reactor MBR have been found to be low dissolved oxygen (< 0.6 mg/L) and high OLR (approximately 0.64 kg COD/m3/d) at an HRT of 0.5 day and SRT of approximately 85 days.  相似文献   
117.
A credible accounting of national and regional inventories for the greenhouse gas (GHG) reduction has emerged as one of the most significant current discussions. This article assessed the regional GHG emissions by three categories of the waste sector in Daejeon Metropolitan City (DMC), Korea, examined the potential for DMC to reduce GHG emission, and discussed the methodology modified from Intergovernmental Panel on Climate Change and Korea national guidelines. During the last five years, DMC's overall GHG emissions were 239 thousand tons C02 eq./year from eleven public environmental infrastructure facilities, with a population of 1.52 million. Of the three categories, solid waste treatment/disposal contributes 68%, whilst wastewater treatment and others contribute 22% and 10% respectively. Among GHG unit emissions per ton of waste treatment, the biggest contributor was waste incineration of 694 kg CO2 eq./ton, followed by waste disposal of 483 kg CO2 eq./ton, biological treatment of solid waste of 209 kg CO2 eq./ton, wastewater treatment of 0.241 kg CO2 eq./m3, and public water supplies of 0.067 kg CO2 eq./m3. Furthermore, it is suggested that the potential in reducing GHG emissions from landfill process can be as high as 47.5% by increasing landfill gas recovery up to 50%. Therefore, it is apparent that reduction strategies for the main contributors of GHG emissions should take precedence over minor contributors and lead to the best practice for managing GHGs abatement.  相似文献   
118.
Nitrous acid (HONO) may cause adverse effects to mucous membranes and lung function when people are exposed to higher HONO concentrations than those present in typical indoor residential environments. Therefore, determination of HONO concentration in indoor environments is required to investigate occurrences of high HONO levels. In this work, a high-time-resolution measurement system was utilized to better understand the levels and dynamic behavior of HONO in an indoor environment. The performance of the in situ HONO analyzer applied to this work was evaluated using a 12-hr integrated annular denuder technique under ambient conditions. Both methods for the measurements of HONO were in good agreement, with a regression slope of 0.84, an intercept of 0.09, and correlation coefficient (r2) of 0.67. Indoor HONO and nitrogen oxide concentrations were also observed for approximately 5 days in winter in the living room of an apartment that had a gas range for cooking in the kitchen. Investigation of the relationships among nitric oxide (NO), nitrite (NO2), and HONO concentrations suggests that HONO production during combustion could be the result of direct emission, whereas the heterogeneous NO2 chemistry during the background period and after combustion was the possible pathway of HONO production. Controlled combustion experiments, performed at a burning rate of 50% valve setting, show peak HONO concentrations during the unvented combustion to be approximately 8-10 times higher than background levels depending on the time of day. At a burning rate setting of 50%, the peak concentration of HONO during unvented combustion was found to be 33-37% higher than those from "weak" (airflow = 340 m3/hr) and "strong" (airflow = 540 m3/hr) vented combustions. The decay rate of the HONO concentrations for the unvented combustion conditions was approximately 2-fold higher in the daytime than in the nighttime and significantly less than those of NO and NO2.  相似文献   
119.
Polybrominated diphenyl ethers (PBDEs), commonly used flame retardants, have been reported as potential endocrine disruptor and neurodevelopmental toxicants, thus giving rise to the public health concern. The goal of this study was to investigate the relationship between umbilical cord blood, maternal blood, and breast milk concentrations of PBDEs in South Korean. We assessed PBDE levels in paired samples of umbilical cord blood, maternal blood, and breast milk. The levels of seven PBDE congeners were measured in 21 paired samples collected from the Cheil Woman’s Hospital (Seoul, Korea) in 2008. We also measured thyroid hormones levels in maternal and cord blood to assess the association between PBDEs exposure and thyroid hormone levels. However, there was no correlation between serum thyroxin (T4) and total PBDEs concentrations. The total PBDEs concentrations in the umbilical cord blood, maternal blood, and breast milk were 10.7 ± 5.1 ng g−1 lipid, 7.7 ± 4.2 ng g−1 lipid, and 3.0 ± 1.8 ng g−1 lipid, respectively. The ranges of total PBDE concentrations observed were 2.28-30.94 ng g−1 lipid in umbilical cord blood, 1.8-17.66 ng g−1 lipid in maternal blood, and 1.08-8.66 ng g−1 lipid in breast milk. BDE-47 (45-73% of total PBDEs) was observed to be present dominantly in all samples, followed by BDE-153. A strong correlation was found for major BDE-congeners between breast milk and cord blood or maternal blood and cord blood samples. The measurement of PBDEs concentrations in maternal blood or breast milk may help to determine the concentration of PBDEs in infant.  相似文献   
120.
Background culturable bacteria aerosols were collected and identified in two large public buildings located in Minneapolis, Minnesota and Seattle, Washington over a period of 5 months and 3 months, respectively. The installed particulate air filters in the ventilation systems were used as the aerosol sampling devices at each location. Both pre and final filters were collected from four air handing units at each site to determine the influence of location within the building, time of year, geographical location and difference between indoor and outdoor air. Sections of each loaded filter were eluted with 10 ml of phosphate buffered saline (PBS). The resulting solutions were cultured on blood agar plates and incubated for 24 h at 36 degrees C. Various types of growth media were then used for subculturing, followed by categorization using a BioLog MicroStation (Biolog, Hayward, CA, USA) and manual observation. Environmental parameters were gathered near each filter by the embedded on-site environmental monitoring systems to determine the effect of temperature, humidity and air flow. Thirty nine different species of bacteria were identified, 17 found only in Minneapolis and 5 only in Seattle. The hardy spore-forming genus Bacillus was the most commonly identified and showed the highest concentrations. A significant decrease in the number of species and their concentration occurred in the Minneapolis air handling unit supplying 100% outdoor air in winter, however no significant correlations between bacteria concentration and environmental parameters were found.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号