全文获取类型
收费全文 | 147篇 |
免费 | 2篇 |
国内免费 | 5篇 |
专业分类
安全科学 | 4篇 |
废物处理 | 23篇 |
环保管理 | 17篇 |
综合类 | 8篇 |
基础理论 | 26篇 |
污染及防治 | 64篇 |
评价与监测 | 10篇 |
社会与环境 | 2篇 |
出版年
2022年 | 3篇 |
2021年 | 1篇 |
2020年 | 1篇 |
2019年 | 2篇 |
2018年 | 4篇 |
2017年 | 6篇 |
2016年 | 6篇 |
2015年 | 2篇 |
2014年 | 6篇 |
2013年 | 9篇 |
2012年 | 6篇 |
2011年 | 16篇 |
2010年 | 13篇 |
2009年 | 9篇 |
2008年 | 13篇 |
2007年 | 15篇 |
2006年 | 8篇 |
2005年 | 2篇 |
2004年 | 11篇 |
2003年 | 6篇 |
2002年 | 4篇 |
2001年 | 3篇 |
2000年 | 2篇 |
1998年 | 1篇 |
1997年 | 1篇 |
1992年 | 1篇 |
1989年 | 2篇 |
1984年 | 1篇 |
排序方式: 共有154条查询结果,搜索用时 78 毫秒
41.
Sung Ho Hwang Chung Sik Yoon Kyong Nam Ryu Samuel Y. Paik Jun Ho Cho 《Atmospheric environment (Oxford, England : 1994)》2010,44(13):1658-1662
This study assessed bacterial concentrations in indoor air at 25 underground railway stations in Seoul, Korea, and investigated various related factors including the presence of platform screen doors (PSD), depth of the station, year of construction, temperature, relative humidity, and number of passengers. A total of 72 aerosol samples were collected from all the stations. Concentrations of total airborne bacteria (TAB) ranged from not detected (ND) to 4997 CFU m?3, with an overall geometric mean (GM) of 191 CFU m?3. Airborne bacteria were detected at 23 stations (92%) and Gram-negative bacteria (GNB) were detected at two stations (8%). TAB concentrations of four stations (16%) exceeded 800 CFU m?3, the Korea indoor bio-aerosol guideline. The results of the study showed that TAB concentrations at the stations without PSD showed higher TAB concentrations than those with PSD, though not at statistically significant levels. TAB concentrations of deeper stations revealed significantly higher levels than those of shallower stations. Based on this study, it is recommended that mitigation measures be applied to improve the indoor air quality (IAQ) of underground railway stations in Seoul, with focused attention on deeper stations. 相似文献
42.
Recovery of iron oxide and calcium chloride from an iron-rich chloride waste using calcium carbonate
Yang Hee Jung Yoon Seok Won Kim You Jin Park Hee Sun Huh Seok Hur Nam Hwi 《Journal of Material Cycles and Waste Management》2021,23(1):222-230
Journal of Material Cycles and Waste Management - The ilmenite-chloride process has used for the production of TiCl4 from the ilmenite (FeTiO3) ore, which produces cyclone dust containing mostly... 相似文献
43.
Oxidative degradation of dimethylsulfoxide by locally concentrated hydroxyl radicals in streamer corona discharge process 总被引:2,自引:0,他引:2
This study systematically investigates the characteristic degradation behaviors of dimethylsulfoxide (DMSO) by the streamer corona discharge process (SCDP) in water. The analysis of the oxidized intermediates of DMSO shows that hydroxyl radical (*OH) is the main oxidant responsible for the degradation of DMSO in the SCDP. The various experiments on the degradation and mineralization of DMSO, and the effect of the *OH scavenger suggest that the SCDP produces locally concentrated *OHs in and around the plasma channel. This explanation was also supported by the formation of H(2)O(2) and the effect of the *OH scavenger on the H(2)O(2) production rate in the SCDP. Based on the kinetic data for the degradation of DMSO and the production of H(2)O(2) in the SCDP, the volume of the active region in which the *OHs are concentrated, and the effective concentration of *OH in that region were estimated to be 0.21 microl and 5.0 x 10(-3)M, respectively. This level of *OH concentration in the SCDP is approximately 10(7)-10(9) times higher than that generated in ordinary advanced oxidation processes using *OH. The ramifications of the results obtained in this study on successful water treatment using the SCDP are also discussed. 相似文献
44.
Emission characteristics of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) in diesel engine were studied with variable load rate of the diesel engine with the emission test cycles, US D-13 mode. The load rate is changed from 25% to 50% and 75% at constant speed of 2400 rpm. PCDD/Fs concentration and phase distribution of PCDD/Fs with the isokinetic sampling of exhaust gas is obtained in this study. The average PCDD/Fs concentrations per unit of exhaust gas with 25%, 50% and 75% load rate are 14.5, 6.9 and 6.4 pg-TEQ/N m3, respectively. In all diesel engine runs, PCDFs are more prevalent than PCDDs. As a load rate is increased, the ratio of PCDDs is gradually decreased. The amount of high-chlorinated PCDDs emitted in diesel engine is larger than that of low-chlorinated PCDDs. The significant emission form of PCDD/Fs produced from diesel engines exhaust is a gas phase. 相似文献
45.
Adel Shirmohammadi Kwang S. Yoon Walter J. Rawls Oliver H. Smith 《Journal of the American Water Resources Association》1997,33(5):1069-1076
ABSTRACT: Proper selection of curve number values will improve the capability of the SCS-Curve Number procedure in predicting runoff. Both CREAMS and GLEAMS models use the Smith and Williams (1980) approach of converting CNII (curve number value for average antecedent moisture conditions) into CNI (curve number value for dry antecedent moisture conditions) in calculating the soil retention parameter (S). CREAMS and GLEAMS have been found to under predict runoff because of the internal conversion of CNII to CNI. This study shows modifications of the GLEAMS model using CMI without converting it to CM and it also shows the seasonal curve number approaches with and without converting CNII to CNI. Results indicate that using CNII without internal conversion to CNI provides better runoff and erosion predictions than the original version of GLEAMS and versions with seasonal curve numbers when tested with four years of field data in the Coastal Plain physiographic region of Maryland. 相似文献
46.
Woo-Jung Choi Gwang-Hyun Han Sang-Mo Lee Goon-Taek Lee Kwang-Sik Yoon Soo-Myung Choi Hee-Myong Ro 《Agriculture, ecosystems & environment》2007,120(2-4):259-268
An understanding of the long-term changes in the nitrate contamination pattern of unconfined groundwater is critical to conservation of drinking water in rural areas supporting mixed land-use activities such as cropping, livestock farming, and residence. To examine the effect of different land-use activities on nitrate contamination, groundwater samples were collected monthly for 3 years (1997–1999) from 12 wells in rural areas with different land-use activities and analyzed for the concentrations and N isotopic ratios (δ15N) of nitrate. The characteristics of nitrate contamination clearly differed with land-use activities. The percentages of samples that had a nitrate concentration exceeding the national standard for drinking water (10 mg N L−1) were 0, 23, 43, and 67% for the uncontaminated natural area, cropping area, cropping-livestock farming complex area, and residential area, respectively. The range of δ15N values was between +1.4 and +4.5‰ for groundwater nitrate from the uncontaminated natural area. In the cropping area, the δ15N values were slightly different with the type of fertilizer applied to fields in the vicinity of the well, and the values ranged between +8.7 and +14.4‰ for the compost-applied area and between +4.5 and +8.5‰ for the area where urea was applied with compost. The δ15N values of the cropping-livestock farming complex area ranged from +1.0 to +17.7‰, probably resulting from mixed contamination sources (inorganic fertilizer and livestock manure). The well located closest to the livestock feedlot had relatively higher δ15N values, with a range between +8.7 and +17.6‰. In the residential area, a higher δ15N (most frequently above +10‰) of nitrate suggested that the major source of contamination was effluent from leaky septic tanks. Our data showed that unconfined groundwater is susceptible to land-use activities above the aquifers, and the impacts of the activities could be more precisely inferred from long-term data on the concentration and δ15N of nitrate. By determining the impacts, more effective (specific to contamination sources) measures for preventing groundwater quality could be implemented. 相似文献
47.
48.
Sung Mo Son Uk Yeong Kim Ik Sang Shin Yong Kang Suk Hwan Kang Byung Tae Yoon Myung Jae Choi 《Journal of Material Cycles and Waste Management》2009,11(2):138-143
The characteristics of bubble properties and the chaotic flow behavior of gas were investigated in an annular fluidized bed
(0.102 m in inner diameter and 2 m in height) because the behavior of gas flow in such a reactor is one of the important factors
governing reactor operation, reactor performance, and the reaction itself. Pressure fluctuations as a state variable for the
analysis of gas flow behavior were measured and analyzed. Bubble properties were determined by adopting the cross-correlation
function of pressure fluctuations. The resultant chaotic flow behavior of gas was interpreted by means of chaotic parameters
such as the Kolmogorov entropy. It was found that the Kolmogorov entropy could be utilized effectively to explain the nonlinear
dynamic behavior of gas-solid flow in the annular fluidized bed. The pierced length and rising velocity of bubbles increased
with increasing gas velocity, bed temperature, and particle size of the bed material. The bubble frequency increased with
increasing gas velocity and bed temperature, while it decreased with increasing particle size of the bed material. Correlations
to predict the bubble properties in annular fluidized-bed reactors were suggested. 相似文献
49.
Sung-Wook Yoon Dong-Ho Rie Ha-Young Kim 《Journal of Loss Prevention in the Process Industries》2009,22(6):954-957
The aim of this research is to find the optimum smoke extraction rate through the ventilation shaft in case of a fire in a long road tunnel. Furthermore, it is also investigated whether the current emergency ventilation design practice using a vertical shaft can limit the smoke propagation from a fully loaded gasoline tank lorry fire. For this research, scaled model experiments were carried out using a 20 m- long model tunnel with a vertical shaft. A CFD modeling tool was also extensively utilized to investigate the extremely dangerous situation in which a fully loaded gasoline tank lorry is burning inside a long road tunnel. 相似文献
50.
Effects of initial iron corrosion rate on long-term performance of iron permeable reactive barriers: Column experiments and numerical simulation 总被引:3,自引:1,他引:2
Jin suk O Sung-Wook Jeen Robert W. Gillham Lai Gui 《Journal of contaminant hydrology》2009,103(3-4):145-156
Column experiments and numerical simulation were conducted to test the hypothesis that iron material having a high corrosion rate is not beneficial for the long-term performance of iron permeable reactive barriers (PRBs) because of faster passivation of iron and greater porosity loss close to the influent face of the PRBs. Four iron materials (Connelly, Gotthart-Maier, Peerless, and ISPAT) were used for the column experiments, and the changes in reactivity toward cis-dichloroethene (cis-DCE) degradation in the presence of dissolved CaCO3 were evaluated. The experimental results showed that the difference in distribution of the accumulated precipitates, resulting from differences in iron corrosion rate, caused a difference in the migration rate of the cis-DCE profiles and a significant difference in the pattern of passivation, indicating a faster passivation in the region close to the influent end for the material having a higher corrosion rate. For the numerical simulation, the accumulation of secondary minerals and reactivity loss of iron were coupled using an empirically-derived relationship that was incorporated into a multi-component reactive transport model. The simulation results provided a reasonable representation of the evolution of iron reactivity toward cis-DCE treatment and the changes in geochemical conditions for each material, consistent with the observed data. The simulations for long-term performance were also conducted to further test the hypothesis and predict the differences in performance over a period of 40 years under typical groundwater conditions. The predictions showed that the cases of higher iron corrosion rates had earlier cis-DCE breakthrough and more reduction in porosity starting from near the influent face, due to more accumulation of carbonate minerals in that region. Therefore, both the experimental and simulation results appear to support the hypothesis and suggest that reactivity changes of iron materials resulting from evolution of geochemical conditions should be considered in the design of iron PRBs. 相似文献