首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   52篇
  免费   0篇
安全科学   5篇
废物处理   4篇
环保管理   3篇
综合类   7篇
基础理论   10篇
污染及防治   14篇
评价与监测   5篇
社会与环境   4篇
  2023年   1篇
  2022年   6篇
  2020年   1篇
  2019年   1篇
  2018年   3篇
  2017年   2篇
  2016年   3篇
  2015年   5篇
  2014年   4篇
  2013年   7篇
  2012年   5篇
  2011年   1篇
  2010年   2篇
  2009年   3篇
  2008年   2篇
  2006年   1篇
  2005年   1篇
  2002年   1篇
  1999年   1篇
  1958年   1篇
  1955年   1篇
排序方式: 共有52条查询结果,搜索用时 15 毫秒
41.
In this study, the performance and the efficiency of physico-chemical effluent treatment in a paper mill was investigated, with the aim of evaluating the treatment rationality and running stability. The effluent treatment plant (ETP) uses alum as a coagulant and polyacrylamide as a flocculant in multi-stage water purification. Inadequate efficiency and some operational problems were observed and their occurrences were investigated. Several simple measures inside the mill and some technical measures can prevent or postpone expensive end-of-pipe treatment investments, such as biological treatment. Chemically enhanced primary treatment under optimal operating conditions can be a stand-alone technique for achieving high quality effluent. Furthermore, reductions in wastewater generation in combination with fiber and filler recovery provide environmental benefits as well as significant economic savings in production. The advantages of the cleaner production approach in existing treatment units compared to expensive biological end-of-pipe technologies are obvious. This study demonstrated that the examined mill could easily and cost-effectively change its water system toward strict discharge limits by continuing to use the existing treatment units.  相似文献   
42.
The aim of this study was to determine the possible effects of meteorological factors on the crown condition of Norway spruce in habitats with different site humidity. In many cases the correlation between meteorological indices and crown condition was stronger and more reliable in habitats with normal humidity than in overmoist habitats. Our results suggest that meteorological conditions during the vegetation period play more significant role compared with dormant period for spruce crown condition.  相似文献   
43.
Genotoxicity of freshwater pollution was assessed by measuring DNA damage in haemocytes of caged freshwater crayfish Astacus leptodactylus by the means of Comet assay and micronucleus test, integrated with the measurements of physiological (total protein concentration) and immunological (total haemocyte count) haemolymph parameters as biomarkers of undergone stress. Crayfish were collected at the reference site (River Mre?nica) and exposed in cages for 1 week at three polluted sites along the Sava River (Zagreb, Sisak, Krapje). The long term pollution status of these locations was confirmed by chemical analyses of sediments. Statistically significant increase in DNA damage measured by the Comet assay was observed at all three polluted sites comparing to the crayfish from reference site. In addition, native crayfish from the mildly polluted site (Krapje) cage-exposed on another polluted site (Zagreb) showed lower DNA damage than crayfish from the reference site exposed at the same location indicating adaptation and acclimatisation of crayfish to lower levels of pollution. Micronuclei induction showed similar gradient of DNA damage as Comet assay, but did not reach the statistical significance. Observed increase in total haemocyte count and total protein content in crayfish from polluted environments in the Sava River also confirmed stress caused by exposure to pollution. The results of this study have proved the applicability of caging exposure of freshwater crayfish A. leptodactylus in environmental genotoxicity monitoring using Comet assay and micronucleus test.  相似文献   
44.
Despite that the use of DDT has been restricted for more than 40 years to malaria affected areas, low doses of this pesticide and its metabolites DDE and DDD can be found in the environment around the world. Although it has been shown that these pollutants induce cell and DNA damage, the mechanisms of their cytogenotoxic activity remains largely unknown. This study looks into their possible genotoxic effects, at doses that can be found in body fluids, on human lymphocytes using the cytokinesis-block micronucleus assay and the comet assay. After exposure for 1, 6, and 24 h compounds p,p′-DDT (0.1 μg mL−1), p,p′-DDE (4.1 μg mL−1), and p,p′-DDD (3.9 μg mL−1) showed increase in DNA damage. The most significant results were observed at exposure period of 24 h where number of micronucleated cells increased from control 2.5 ± 0.71 to 23.5 ± 3.54, 13.5 ± 0.71, and 16.5 ± 6.36 for DDT, DDE, and DDD, respectively. Similar effect was observed using comet test where the percentage of DNA in comets tail increased from control 1.81 ± 0.16 to 17.24 ± 0.55, 11.21 ± 0.56 and 9.28 ± 0.50 for each compound, respectively. At the same time Fpg-comet assay failed to report induction of oxidative DNA damage of these pollutants. Additionally, the type of cell death was determined using diffusion assay and necrosis dominated. Our findings suggest that even at low concentrations, these pesticides could induce cytogenetic damage to human peripheral blood lymphocytes and in that manner have the impact on human health as well.  相似文献   
45.
Although there are tendencies to develop a single common index which would describe an overall air quality status within an area, constructed from a choice of measurements of individual pollutants, indices describing individual pollutants themselves have several potentials which can be used in ways which are not possible with pollutant concentrations. On the case of Belgrade, Serbia, we investigated possibilities of using such indices for comparisons between pollutants, characterization of monitoring sites, and extending their use to include elements of population exposure. A methodology of adjusting the results obtained at monitoring stations located in severe pollution conditions, like street canyons, is proposed and used.  相似文献   
46.
We have measured the elemental concentrations in aerosols with a 2-h time resolution in two different types of working environment: a chemistry laboratory dealing with the processing of advanced nanoparticulate materials and a medium-sized machine workshop. Non-stop 10-day and 12-day samplings were performed at each location in order to determine the concentration trends during the non-working/working and weekday/weekend periods. Supplementary measurements of PM10 aerosols with a 2-day sample collection time were performed with a standard Gent PM10 sampler to compare the elemental concentrations with the time-averaged concentrations detected by the 2D step-sampler. The concentrations were determined a posteriori by analyzing the x-ray spectra of aerosol samples emitted after 3-MeV proton bombardment. The PM10 samples collected in the chemistry laboratory were additionally inspected by scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDX) to determine the chemical compositions of the individual particles. In the workshop, a total PM10 mass sampling was performed simultaneously with a minute resolution to compare the signal with typical outdoor PM10 concentration levels. A factor analysis of the time-resolved dataset points to six and eight factors in the chemistry laboratory and the machine workshop, respectively. These factors describe most of the data variance, and their composition in terms of different elements can be related to specific indoor activities and conditions. We were able to demonstrate that the elemental concentration sampling with hourly resolution is an excellent tool for studying the indoor air pollution. While sampling the total PM10 mass concentration with a minute resolution may lack the potential to identify the emission sources in a “noisy” environment, the time averaging on a day time scale is too coarse to cope with the working dynamics, even if elemental sensitivity is an option.  相似文献   
47.
Resuspended street dust is a source of inhalable particles in urban environments. Despite contaminated street dust being a possible health risk factor for local population, little is known about the contribution of atmospheric dust emissions and other factors to the content of toxic metals in street dust. The impact of smelting, traffic, and power plants on metal contaminates in street dust is the focus of street dust sampling at 46 locations in the Witbank area (Republic of South Africa). This area is characterized by numerous open-pit coal mines in the Karoo coal basin, which provides a cheap source of energy to numerous metallurgical smelters and ironworks and supplies coal to the coal-fired power plants located nearby. Street dust was collected on asphalt or concrete surfaces with hard plastic brushes, avoiding collecting of possible sand, soil, or plant particles. Chemical analysis was done on the <0.125 mm fraction using inductively coupled plasma mass spectrometry subsequent to total digestion. Exceptionally high concentrations of metals were detected with concentrations of Fe reaching 17.7 %, Cr 4.3 %, Mn 2 %, Ni 366 mg/kg, and V 4,410 mg/kg. Factor analysis indicates three sources for the pollution. Road traffic which contributes to the high concentrations of Cu, Pb, Sb, and Sn, with the highest impacts detected in the town of Witbank. The second source is associated with the metal smelting industry, contributing to Fe, Co, Mn, and V emissions. The highest factor scores were observed around four metallurgical smelter operations, located in the Ferrobank, Highveld, and Clewer industrial areas. Impact of vanadium smelter to street dust composition could still be detected some 20 km away from the sources. Exceptionally high concentrations of Cr were observed in four samples collected next to the Ferrobank industrial area, despite Cr not being loaded in factor 2. The last source of the pollution is most probably fly ash associated with the coal-fired power plants and fly ash dumps. Elements which are associated with this source are Al, Sr, and Li. This factor is abundant in the coal mining part of the study area.  相似文献   
48.
We report an unusual case of the complete Currarino triad diagnosed in a fetus at 21 weeks' gestation by means of prenatal ultrasonography (US). The highly suspicious findings in the fetus were accompanied by analogous US findings in the mother who suffered from mild symptoms of up to that time unrecognized Currarino triad. Consecutively, magnetic resonance imaging (MRI) confirmed the findings simultaneously in the fetus and in her mother. This is the first report describing the prenatal diagnosis of Currarino triad without the background of positive family history. To our knowledge, the prenatal MRI findings of Currarino triad have not yet been published. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   
49.
Environmental Science and Pollution Research - Deposits remained after coal combustion are a well-known occurrence in the world; unfortunately, only a small percentage of such deposits are...  相似文献   
50.
Environmental Science and Pollution Research - The continuous use of household and personal care products (HPCPs) produces an immense amount of chemicals, such as parabens, bisphenols,...  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号