A biofilm membrane bioreactor (BF-MBR) and a conventional membrane bioreactor (MBR) were parallelly operated for treating digested piggery wastewater. The removal performance of COD, TN, NH4+-N, TP as well as antibiotics were simultaneously studied when the hydraulic retention time (HRT) was gradually shortened from 9 d to 1 d and when the ratio of influent COD to TN was changed. The results showed that the effluent quality in both reactors was poor and unstable at an influent COD/TN ratio of 1.0±0.2. The effluent quality was significantly improved as the influent COD/TN ratio was increased to 2.3±0.5. The averaged removal rates of COD, NH4+-N, TN and TP were 92.1%, 97.1%, 35.6% and 54.2%, respectively, in the BF-MBR, significantly higher than the corresponding values of 91.7%, 90.9%, 17.4% and 31.9% in the MBR. Analysis of 11 typical veterinary antibiotics (from the tetracycline, sulfonamide, quinolone, and macrolide families) revealed that the BF-MBR removed more antibiotics than the MBR. Although the antibiotics removal decreased with a shortened HRT, high antibiotics removals of 86.8%, 80.2% and 45.3% were observed in the BF-MBR at HRTof 5–4 d, 3–2 d and 1 d, respectively, while the corresponding values were only 83.8%, 57.0% and 25.5% in the MBR. Moreover, the BF-MBR showed a 15% higher retention rate of antibiotics and consumed 40% less alkalinity than the MBR. Results above suggest that the BF-MBR was more suitable for digested piggery wastewater treatment.
Tea saponin (TS), a kind of green biosurfactant produced by plants, was added into the Cd–pyrene co-contaminated soils to evaluate its influence on phytoremediation of Cd and pyrene by Lolium multiflorum. The results showed that the accumulation of pyrene in L. multiflorum was significantly promoted by the TS. Compared with no TS treatments (PL and ML), the aboveground concentrations of pyrene in TS treatments (PLT and MLT) increased by 135 and 30%, respectively, and the underground concentrations of pyrene in TS treatments (PLT and MLT) increased by 40 and 25%. The concentrations of Cd in the aboveground and underground parts in single contaminated treatments were all significantly more than those in co-contaminated treatments, while the situation of pyrene was quite the reverse. Besides, the addition of TS enhanced activities of dehydrogenase and polyphenol oxidase in soils and increased the biomass of L. multiflorum. The micromorphology of L. multiflorum was not affected by TS. The study suggests that the use of L. multiflorum with TS is an alternative technology for remediation of Cd–pyrene co-contaminated soils. 相似文献
In a proton exchange membrane electrolyzer cell (PEMEC), liquid/gas diffusion layer (LGDL) is expected to transport electrons, heat, and reactants/products to and from the catalyst layer with minimum voltage, current, thermal, interfacial, and fluidic losses. In addition, carbon materials, which are typically used in PEM fuel cells (PEMFCs), are unsuitable in PEMECs due to the high ohmic potential and highly oxidative environment of the oxygen electrode. In this study, a set of titanium gas diffusion layers with different thicknesses and porosities are designed and examined coupled with the development of a robust titanium bipolar plate. It has been found that the performance of electrolyzer improves along with a decrease in thickness or porosity of the anode LGDL of titanium woven meshes. The ohmic resistance of anode LGDL and contact resistance between anode LGDL and the anode catalyst play dominant roles in electrolyzer performance, and better performance can be obtained by reducing ohmic resistance. Thin titanium LGDLs with straight-through pores and optimal pore morphologies are recommended for the future developments of low-cost LGDLs with minimum ohmic/transport losses. 相似文献
A field survey was conducted to investigate the present situation and health risk of arsenic (As), lead (Pb), cadmium (Cd), copper (Cu), and zinc (Zn) in soils and vegetables in a multi-metal mining area, Gejiu, China. Furthermore, three vegetables (water spinach, potato, and summer squash) containing high metal concentrations were selected to further analyze metal speciation. The results showed that the average concentrations of five metals in soil exceeded the limiting values, and their bioavailable concentrations were significantly positively correlated to the total ones. Heavy metals in the edible parts of vegetables also exceeded the corresponding standards. The leaves of pakchoi, peppermint, and coriander had a strong metal-accumulative ability and they were not suitable for planting. Except the residue forms, the main forms of metals in the edible parts of three selected vegetables were ethanol-, NaCl-, and HAc-extractable fractions for As, Pb, and Cd, respectively; however, Cu was mainly presented as NaCl-extractable and Zn as HAc-extractable fractions. A high proportion of ethanol-extractable As showed that As bioactivity and toxic effects were the highest. Although the total and bioavailable Cd were high in soil, its speciation in vegetables was mainly presented as HAc-extractable fraction, which has a relatively low bioactivity. Lead and arsenic were imposing a serious threat on the local residents via vegetable consumption. 相似文献
Energy supply utilities release significant amounts of greenhouse gases (GHGs) into the atmosphere. It is essential to accurately estimate GHG emissions with their uncertainties, for reducing GHG emissions and mitigating climate change. GHG emissions can be calculated by an activity-based method (i.e., fuel consumption) and continuous emission measurement (CEM). In this study, GHG emissions such as CO2, CH4, and N2O are estimated for a heat generation utility, which uses bituminous coal as fuel, by applying both the activity-based method and CEM. CO2 emissions by the activity-based method are 12–19% less than that by the CEM, while N2O and CH4 emissions by the activity-based method are two orders of magnitude and 60% less than those by the CEM, respectively. Comparing GHG emissions (as CO2 equivalent) from both methods, total GHG emissions by the activity-based methods are 12–27% lower than that by the CEM, as CO2 and N2O emissions are lower than those by the CEM. Results from uncertainty estimation show that uncertainties in the GHG emissions by the activity-based methods range from 3.4% to about 20%, from 67% to 900%, and from about 70% to about 200% for CO2, N2O, and CH4, respectively, while uncertainties in the GHG emissions by the CEM range from 4% to 4.5%. For the activity-based methods, an uncertainty in the Intergovernmental Panel on Climate Change (IPCC) default net calorific value (NCV) is the major uncertainty contributor to CO2 emissions, while an uncertainty in the IPCC default emission factor is the major uncertainty contributor to CH4 and N2O emissions. For the CEM, an uncertainty in volumetric flow measurement, especially for the distribution of the volumetric flow rate in a stack, is the major uncertainty contributor to all GHG emissions, while uncertainties in concentration measurements contribute a little to uncertainties in the GHG emissions.
Implications:Energy supply utilities contribute a significant portion of the global greenhouse gas (GHG) emissions. It is important to accurately estimate GHG emissions with their uncertainties for reducing GHG emissions and mitigating climate change. GHG emissions can be estimated by an activity-based method and by continuous emission measurement (CEM), yet little study has been done to calculate GHG emissions with uncertainty analysis. This study estimates GHG emissions and their uncertainties, and also identifies major uncertainty contributors for each method. 相似文献
Organochlorine pesticides (OCPs) are ubiquitous pollutants, and their presence in urban lakes is a concern for human and ecological health. Surface sediments in the East Lake, China, were collected in winter 2012 and summer 2013 to investigate concentrations, distribution patterns, possible sources, and potential ecological risks of OCPs in this area. The total concentrations of 14 OCPs ranged from 6.3 to 400 ng g?1 dry weight (dw) with an average concentration of 79 ng g?1 dw. The mean values of hexachlorocyclohexanes (HCHs) (α-, β-, γ-, and δ-HCH) and dichlorodiphenyltrichloroethanes (DDTs) (p,p’-DDE, p,p’-DDD, and p,p’-DDT) were 36 and 7.6 ng g?1 dw, accounting for 45 and 10 % of the total OCPs, respectively. The concentrations of OCPs in sediment samples collected in winter were significantly higher than those in summer, especially the HCHs, of which in winter were two times greater than summer. Composition analyses indicated that DDTs and endosulfan were mainly from historical contribution. Historical use of technical HCH and new input of lindane were probably the source of HCHs in the East Lake. Most sampling sites of HCHs and DDTs were found to have the potential ecological risk based on levels specified in the sediment quality standards. 相似文献
Subway systems are considered as main public transportation facility in developed countries. Time spent by people in indoors, such as underground spaces, subway stations, and indoor buildings, has gradually increased in the recent past. Especially, operators or old persons who stay in indoor environments more than 15 hr per day usually influenced a greater extent by indoor air pollutants. Hence, regulations on indoor air pollutants are needed to ensure good health of people. Therefore, in this study, a new cumulative calculation method for the estimation of total amounts of indoor air pollutants emitted inside the subway station is proposed by taking cumulative amounts of indoor air pollutants based on integration concept. Minimum concentration of individual air pollutants which naturally exist in indoor space is referred as base concentration of air pollutants and can be found from the data collected. After subtracting the value of base concentration from data point of each data set of indoor air pollutant, the primary quantity of emitted air pollutant is calculated. After integration is carried out with these values, adding the base concentration to the integration quantity gives the total amount of indoor air pollutant emitted. Moreover, the values of new index for cumulative indoor air quality obtained for 1 day are calculated using the values of cumulative air quality index (CAI). Cumulative comprehensive indoor air quality index (CCIAI) is also proposed to compare the values of cumulative concentrations of indoor air pollutants. From the results, it is clear that the cumulative assessment approach of indoor air quality (IAQ) is useful for monitoring the values of total amounts of indoor air pollutants emitted, in case of exposure to indoor air pollutants for a long time. Also, the values of CCIAI are influenced more by the values of concentration of NO2, which is released due to the use of air conditioners and combustion of the fuel. The results obtained in this study confirm that the proposed method can be applied to monitor total amounts of indoor air pollutants emitted, inside apartments and hospitals as well.
Implications: Nowadays, subway systems are considered as main public transportation facility in developed countries. Time spent by people in indoors, such as underground spaces, subway stations, and indoor buildings, has gradually increased in the recent past. Especially, operators or old persons who stay in the indoor environments more than 15 hr per day usually influenced a greater extent by indoor air pollutants. Hence, regulations on indoor air pollutants are needed to ensure good health of people. Therefore, this paper presents a new methodology for monitoring and assessing total amounts of indoor air pollutants emitted inside underground spaces and subway stations. A new methodology for the calculation of cumulative amounts of indoor air pollutants based on integration concept is proposed. The results suggest that the cumulative assessment approach of IAQ is useful for monitoring the values of total amounts of indoor air pollutants, if indoor air pollutants accumulated for a long time, especially NO2 pollutants. The results obtained here confirm that the proposed method can be applied to monitor total amounts of indoor air pollutants emitted, inside apartments and hospitals as well. 相似文献