首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   144篇
  免费   4篇
安全科学   12篇
废物处理   12篇
环保管理   13篇
综合类   13篇
基础理论   16篇
污染及防治   67篇
评价与监测   9篇
社会与环境   4篇
灾害及防治   2篇
  2023年   4篇
  2022年   1篇
  2021年   2篇
  2020年   1篇
  2019年   10篇
  2018年   5篇
  2017年   8篇
  2016年   12篇
  2015年   9篇
  2014年   8篇
  2013年   23篇
  2012年   9篇
  2011年   11篇
  2010年   6篇
  2009年   5篇
  2008年   7篇
  2007年   6篇
  2006年   5篇
  2004年   6篇
  2003年   2篇
  2002年   1篇
  1996年   2篇
  1979年   1篇
  1977年   1篇
  1960年   1篇
  1956年   1篇
  1955年   1篇
排序方式: 共有148条查询结果,搜索用时 125 毫秒
111.
Irrigated agriculture is a major economic contributor of the High Plains Region and it primarily relies on the High Plains Aquifer as a source of water. Over time, areas of the High Plains Aquifer have experienced drawdowns limiting its ability to supply sufficient water to sustain fully irrigated crop production. This among other reasons, including variable climatic factors and differences in state water policy, has resulted in some areas adopting and practicing deficit irrigation management. Considerable research has been conducted across the High Plains Aquifer region to identify locally appropriate deficit irrigation strategies. This review summarizes and discusses research conducted in Nebraska, Colorado, Kansas, and Texas, as well as highlights areas for future research. Editor's note : This paper is part of the featured series on Optimizing Ogallala Aquifer Water Use to Sustain Food Systems. See the February 2019 issue for the introduction and background to the series.  相似文献   
112.
To predict the radon concentration in a house environment and to understand the role of all factors affecting its behavior, it is necessary to recognize time variation in both air exchange rate and radon entry rate into a house. This paper describes a new approach to the separation of their effects, which effectively allows continuous estimation of both radon entry rate and air exchange rate from simultaneous tracer gas (carbon monoxide) and radon gas measurement data. It is based on a state-space statistical model which permits quick and efficient calculations. Underlying computations are based on (extended) Kalman filtering, whose practical software implementation is easy. Key property is the model's flexibility, so that it can be easily adjusted to handle various artificial regimens of both radon gas and CO gas level manipulation. After introducing the statistical model formally, its performance will be demonstrated on real data from measurements conducted in our experimental, naturally ventilated and unoccupied room. To verify our method, radon entry rate calculated via proposed statistical model was compared with its known reference value. The results from several days of measurement indicated fairly good agreement (up to 5% between reference value radon entry rate and its value calculated continuously via proposed method, in average). Measured radon concentration moved around the level approximately 600 Bq m(-3), whereas the range of air exchange rate was 0.3-0.8 (h(-1)).  相似文献   
113.
In the European multi‐centre study BeSeCu (Behaviour, Security, Culture), interviews were conducted in seven countries to explore survivors’ emotional, behavioural, and cognitive responses during disasters. Interviews, either in groups or one‐to‐one, were convened according to type of event: collapse of a building; earthquake; fire; flood; and terror attack. The content analysis of interviews resulted in a theoretical framework, describing the course of the events, behavioural responses, and the emotional and cognitive processing of survivors. While the environmental cues and the ability to recognise what was happening varied in different disasters, survivors’ responses tended to be more universal across events, and most often were adaptive and non‐selfish. Several peri‐traumatic factors related to current levels of post‐traumatic stress were identified, while memory quantity did not differ as a function of event type or post‐traumatic stress. Time since the event had a minor effect on recall. Based on the findings, several suggestions for emergency training are made.  相似文献   
114.
115.
To investigate the drivers for transport and deposition of 17 2,3,7,8-substituted PCDDs/PCDFs along an urban river, water samples from five reservoirs located along the river course were collected in January and July 2008. The concentrations of 17 congeners of PCDD/PCDF were determined and compared to environmental - physical, chemical and biological - conditions. The obtained data revealed that the concentration of the sum of toxic PCDDs/PCDFs in water samples differ between reservoirs as well as between seasons, ranging from 12.04 pg L(-1) in UP (first in the cascade) to 1327.94 pg L(-1) in PR (last in the cascade) during winter of 2008; and from 34.94 pg L(-1) in UP to 1352.50 pg L(-1) in TR (next to last) in summer 2008. In comparison, water samples collected from the river had a concentration several times lower at the first two sites (sites no. 1 and 4) and no detectable values at the last three stations (sites no. 7, 8, 10). The obtained data demonstrated strong or moderate correlations between the sum of 17 PCDDs/PCDFs and TEQ in reservoir water samples and physical, chemical and biological conditions, such as: Mg(2+) (R=0.82; R=0.80, respectively), SO(4)(2-) (R=0.80; R=0.80, respectively), K(+) (R=0.80; R=0.80, respectively), Ca(2+) (R=0.67, R=0.70, respectively), OSM (R=0.63, R=0.70, respectively). In addition, the positive strong correlation between TEQ concentrations and the water temperature (R=0.63) and chlorophyll a content (R=0.90) was noted. The violent weather conditions occurred during the research season with periods of intensive storm events (up to 32 mm in mid July), and thus the increased river flow velocity (up to 0.45 m(3)s(-1)) could have a direct and indirect influence on PCDDs/PCDFs concentration through changes in the sedimentation/resuspension ratio and consequently in transport, deposition and degradation processes along the river/reservoirs.  相似文献   
116.
Accurate assessment of N(2)O emission from soil requires continuous year-round and spatially extensive monitoring or the use of simulation that accurately and precisely predict N(2)O fluxes based on climatic, soil, and agricultural system input data. DAYCENT is an ecosystem model that simulates, among other processes, N(2)O emissions from soils. The purpose of the study was to compare N(2)O fluxes predicted by the DAYCENT model to measured N(2)O fluxes from an experimental corn field in central Iowa. Soil water content temperature and inorganic N, simulated by DAYCENT were compared to measured values of these variables. Field N(2)O emissions were measured using four replicated automated chambers at 6-h intervals, from day of year (DOY) 42 through DOY 254 of 2006. We observed that DAYCENT generally accurately predicted soil temperature, with the exception of winter when predicted temperatures tended to be lower than measured values. Volumetric water contents predicted by DAYCENT were generally lower than measured values during most of the experimental period. Daily N(2)O emissions simulated by DAYCENT were significantly correlated to field measured fluxes; however, time series analyses indicate that the simulated fluxes were out of phase with the measured fluxes. Cumulative N(2)O emission calculated from the simulations (3.29 kg N(2)O-N ha(-1)) was in range of the measured cumulative N(2)O emission (4.26 +/- 1.09 kg N(2)O-N ha(-1)).  相似文献   
117.
Environmental Science and Pollution Research - Solid particles impair the performance of the photovoltaic (PV) modules. This results in power losses which lower the efficiency of the system as well...  相似文献   
118.
The main purpose of the paper is to share the results and experience from processing soil extracts containing a high concentration of both anionic surfactant and polychlorinated biphenyls (PCBs) by use of method the called adsorptive micellar flocculation. The method is similar to coagulation, but the mechanism is more complicated. The flocculants examined in the laboratory section involved ferric chloride, aluminium chloride, ferric sulfate, and aluminum sulfate. It was observed that ferric chloride provides the best PCB removal efficiency from the extract. Subsequently, two extracts obtained from the pilot-scale demonstration of the PCBs leaching from the soils by the surfactant solution were processed by this method. The volume of the extracts processed was several hundred liters. The method proved it can remove PCBs from all extracts with a very high efficiency (greater than 99.99%). The residual PCB concentrations in solution were less than 1 microg/L.  相似文献   
119.
In 2003, concentrations of altogether 17 PCDD/Fs congeners and 12 non-ortho and mono-ortho dioxin-like PCBs were measured in the blood of 60 randomly selected adults who lived in three settlements surrounding a chemical plant that had been producing chlorinated herbicides (mainly HCHs, HCB, pentachlorophenole, 2,4,5-T) in the 1960's; subjects consuming home-produced animal foods were chosen. Twenty blood donors with similar characteristics from the locality with about 80 km distance were used as control subjects. The factors that influenced the dioxin levels were investigated on the basis of a questionnaire. The aim of our study was to find out whether the residents living in the surroundings of the chemical plant are at a greater exposure risk than the controls. To calculate TEQ values, WHO-TEFs were used. The concentrations of four PCDD and six PCDF congeners were below the LOD in more than 50% of samples. Significantly higher WHO-TEQ levels (p<0.05) were found for PCDDs, PCDFs, or PCBs in all three followed up groups compared with controls. The geometric means of the total TEQ values for PCDD/F/PCBs were 43.8, 50.2, and 40.0 pg/g fat compared to 23.2 pg/g fat in the control. The percentages of TEQ due to the measured congeners in exposed groups were 9-10.3% for PCDDs, 20.5-26.9% for PCDFs, 19.2-23.1% for coplanar and 43.6-47.2% for mono-ortho PCBs. In control, the percentage of TEQ was 11.6, 26.7, 24.1, and 37.5%. PCBs, predominantly PCB156, followed by PCB126 contributed 60 to 70% of the total TEQ value. Positive correlation of the PCDD/PCDF/PCB blood levels with age and with consumption of locally produced eggs was found.  相似文献   
120.
The paper presents water-quality evaluation based on an 8-year monitoring programme in the Gdansk Municipality region, on the Southern coast of the Baltic Sea. The studies were carried out from 2000 to 2007 by surface water analysis at 15 various sites within eight watercourses. Sampling sites included rather urbanized or developed lands, farming fields and non-polluted city recreational areas such as parks and forests. Most of the watercourses were sampled monthly at two locations, one within the upper course of the watercourse and the other near its mouth. In all samples, eight parameters of water quality were determined: total suspended solids, dissolved oxygen, water temperature, oxygen saturation, 5-day biochemical oxygen demand, chemical oxygen demand, total phosphorus and total nitrogen concentration. Interpretation of the obtained results revealed that examination of those basic physicochemical parameters permits to discriminate initially watercourses with respect to level of water contamination. During the research, a large dataset was obtained and it was described by both basic statistical parameters and chemometric method of cluster analysis. The paper presents relations between analysed parameters and influence of land exploitation mode on water quality and describes variation of the results both in space and time.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号