全文获取类型
收费全文 | 130篇 |
免费 | 3篇 |
国内免费 | 11篇 |
专业分类
安全科学 | 4篇 |
废物处理 | 11篇 |
环保管理 | 15篇 |
综合类 | 32篇 |
基础理论 | 10篇 |
污染及防治 | 51篇 |
评价与监测 | 16篇 |
社会与环境 | 4篇 |
灾害及防治 | 1篇 |
出版年
2022年 | 2篇 |
2021年 | 2篇 |
2020年 | 2篇 |
2019年 | 3篇 |
2018年 | 1篇 |
2017年 | 7篇 |
2016年 | 11篇 |
2015年 | 7篇 |
2014年 | 9篇 |
2013年 | 11篇 |
2012年 | 11篇 |
2011年 | 10篇 |
2010年 | 5篇 |
2009年 | 8篇 |
2008年 | 5篇 |
2007年 | 16篇 |
2006年 | 7篇 |
2005年 | 7篇 |
2004年 | 10篇 |
2003年 | 6篇 |
2002年 | 3篇 |
2001年 | 1篇 |
排序方式: 共有144条查询结果,搜索用时 15 毫秒
91.
Modeling of road traffic noise and estimated human exposure in Fulton County, Georgia, USA 总被引:1,自引:0,他引:1
Seong JC Park TH Ko JH Chang SI Kim M Holt JB Mehdi MR 《Environment international》2011,37(8):1336-1341
Environmental noise is a major source of public complaints. Noise in the community causes physical and socio-economic effects and has been shown to be related to adverse health impacts. Noise, however, has not been actively researched in the United States compared with the European Union countries in recent years. In this research, we aimed at modeling road traffic noise and analyzing human exposure in Fulton County, Georgia, United States. We modeled road traffic noise levels using the United States Department of Transportation Federal Highway Administration Traffic Noise Model implemented in SoundPLAN?. After analyzing noise levels with raster, vector and fa?ade maps, we estimated human exposure to high noise levels. Accurate digital elevation models and building heights were derived from Light Detection And Ranging survey datasets and building footprint boundaries. Traffic datasets were collected from the Georgia Department of Transportation and the Atlanta Regional Commission. Noise level simulation was performed with 62 computers in a distributed computing environment. Finally, the noise-exposed population was calculated using geographic information system techniques. Results show that 48% of the total county population [N=870,166 residents] is potentially exposed to 55 dB(A) or higher noise levels during daytime. About 9% of the population is potentially exposed to 67 dB(A) or higher noises. At nighttime, 32% of the population is expected to be exposed to noise levels higher than 50 dB(A). This research shows that large-scale traffic noise estimation is possible with the help of various organizations. We believe that this research is a significant stepping stone for analyzing community health associated with noise exposures in the United States. 相似文献
92.
Geonha Kim Woohyeok Jeong Seunghee Choe 《Journal of environmental science and health. Part. B》2013,48(3):287-295
This research investigated the role of the pH buffer capacity of sediment on the dechlorination of atrazine using zero valent iron (ZVI). The buffer capacity of the sediment was quantified by batch experiments and estimated to be 5.0 cmol OH? · pH?1. The sediments were spiked with atrazine at 7.25-36.23 mg kg?1 (6.21 × 10?7–3.09 × 10?6 mol atrazine · g?1 sediment) for the batch experiments. The buffer capacity of the sediment maintained the sediment suspension at neutral pH, thereby enabling continuous dechlorination until the buffer capacity of the sediment was depleted. The pseudo-first order dechlorination constants were estimated to be in the range of 1.19 × 10?2?7.04 × 10?2 d?1 for the atrazine-spiked sediments. 相似文献
93.
Factors influencing natural occurrence of fluoride-rich groundwaters: a case study in the southeastern part of the Korean Peninsula 总被引:3,自引:0,他引:3
Factors regulating the occurrence of fluoride in groundwater were investigated using natural isotope tracers and geochemical data in the southeastern part of Korea where about 10% of the total public water-supply wells (n=422) inspected in this study had fluoride levels exceeding the drinking water limit of Korea (1.5 mg/l). The F-rich public wells are mostly distributed along the major faults, especially in the terrain of the F-rich granitic rocks. The stable isotope analysis results provide substantial information for the relative ages of groundwaters. It is revealed that the F-rich groundwaters are deeply circulating paleogroundwaters and occur along the faults due to upward flow along the fault plane. While reacting with granitic rocks for a prolonged period, the F concentrations of groundwater are continuously enriched even after the groundwater reaches an equilibrium state with respect to fluorite (CaF2) due to removal of Ca by precipitation of calcite (CaCO3). These observations reflect that rock chemistry, groundwater age, well depth, and geologic structure are the important factors controlling the occurrence of high F groundwaters. However, high F groundwaters are rarely observed in the fault zones where the associated fractures are widely developed. Isotopic signature provides an evidence for deep penetration of recently recharged groundwater into the wide fault zone, indicating that the hydrologic condition of the fault is also an important factor controlling the occurrence of high F groundwaters. 相似文献
94.
Lim Hui-Been Park Si-Hyun Hong Hyong-Jin Jeong Ji-Yun Kim Hee-Seok Lee Cheol-Min 《Environmental science and pollution research international》2022,29(18):26648-26659
Environmental Science and Pollution Research - We established a hypothetical acrylic acid leak accident scenario, conducted a health risk assessment of local residents, and compared an actual... 相似文献
95.
S. H. Park E. J. Kim T. H. Yun J. H. Lee C. K. Kim Y. H. Seo S. A. Oh S. S. Choi S. J. Cho M. S. Kim G. Y. Han M. Y. Kim H. S. Jeong D. S. Cheon H. S. Kim 《Food and environmental virology》2010,2(2):69-73
Waterborne outbreaks of enteric viruses are a major public health concern. The present study has been carried out to assess the presence of enteric viruses responsible for human acute gastroenteritis (AGE) in groundwater intended for drinking and produce washing. In total, 62 samples from groundwater for drinking and produce washing collected from Dec 2007 to Dec 2008 in Seoul were tested for enteric viruses using conventional RT–PCR, ELISA, and real-time RT–PCR. Our results showed that enteric viruses were detected in 7 (8.8%) groundwater samples. Rotaviruses were detected in 3 (4.8%) of the samples by ELISA; human adenoviruses were detected in 2 (3.2%) of the samples by ELISA; and nested RT–PCR detected noroviruses in 2 (3.2%) of the samples. In one of the groundwater sample, the norovirus RNA was detected by conventional RT–PCR which was confirmed positive by real-time RT–PCR. Additionally, real-time RT–PCR successfully detected norovirus RNA in five out of 62 water samples (8.1%). The data demonstrate that real-time RT–PCR will be useful as a rapid and sensitive method for detecting norovirus in water samples. Phylogenetic analysis revealed that the noroviruses detected in two of the groundwater samples belonged to GII-4. These studies can provide important information for the prevalence of enteric viruses in Korean groundwater. 相似文献
96.
97.
98.
99.
Min Park Sung Hoon Shim Sang Hyun Jeong Kwang-Joong Oh 《Journal of the Air & Waste Management Association (1995)》2017,67(4):402-411
The nitrogen oxides (NOx) reduction technology by combustion modification which has economic benefits as a method of controlling NOx emitted in the combustion process, has recently been receiving a lot of attention. Especially, the moderate or intense low oxygen dilution (MILD) combustion which applied high temperature flue gas recirculation has been confirmed for its effectiveness with regard to solid fuel as well. MILD combustion is affected by the flue gas recirculation ratio and the composition of recirculation gas, so its NOx reduction efficiency is determined by them. In order to investigate the influence of factors which determine the reduction efficiency of NOx in MILD coal combustion, this study changed the flow rate and concentration of nitrogen (N2), carbon dioxide (CO2) and steam (H2O) which simulate the recirculation gas during the MILD coal combustion using our lab-scale drop tube furnace and performed the combustion experiment. As a result, its influence by the composition of recirculation gas was insignificant and it was shown that flue gas recirculation ratio influences the change of NOx concentration greatly. Implications: We investigated the influence of factors determining the nitrogen oxides (NOx) reduction efficiency in MILD coal combustion, which applied high-temperature flue gas recirculation. Using a lab-scale drop tube furnace and simulated recirculation gas, we conducted combustion testing changing the recirculation gas conditions. We found that the flue gas recirculation ratio influences the reduction of NOx emissions the most. 相似文献
100.
Uddin Md. Jamal Jeong Yeon-Koo 《Environmental science and pollution research international》2020,27(32):39888-39912
Environmental Science and Pollution Research - Arsenic (As) toxicity is a global phenomenon, and it is continuously threatening human life. Arsenic remains in the Earth’s crust in the forms... 相似文献