首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   72篇
  免费   0篇
废物处理   13篇
环保管理   2篇
综合类   7篇
基础理论   9篇
污染及防治   38篇
评价与监测   1篇
社会与环境   2篇
  2023年   1篇
  2021年   1篇
  2019年   1篇
  2018年   4篇
  2016年   1篇
  2014年   6篇
  2013年   12篇
  2012年   3篇
  2011年   1篇
  2009年   1篇
  2008年   5篇
  2007年   11篇
  2006年   4篇
  2005年   3篇
  2004年   3篇
  2003年   1篇
  2002年   3篇
  2001年   1篇
  2000年   2篇
  1999年   1篇
  1995年   1篇
  1990年   1篇
  1984年   1篇
  1982年   2篇
  1981年   1篇
  1978年   1篇
排序方式: 共有72条查询结果,搜索用时 15 毫秒
31.
In tropical regions, landfill leachate contamination at municipal solid waste disposal sites is a critical issue because of the large volume of highly contaminated leachate formed during the rainy season. We evaluated the efficacy of constructed wetlands (CWs) with the ability to reduce the water volume and pollutant levels to reduce leachate contamination compared to the most commonly used treatment system, stabilization ponds, based on parameters obtained in a field experiment in Thailand. The simulation indicated that CWs had a higher potential to reduce the water volume than stabilization ponds over the course of a year. Scenario evaluations under varying initial water depths, system depths, and area sizes indicated that the CWs could reduce the treatment area to prevent overflow and leachate pollution. In addition, the CWs were estimated to reduce the leachate amount and pollution by 83–100% and 92–99%, respectively. When there is limited land available, deeper CWs can be used to sustainably prevent contamination from leachate overflow. Effectively designed CW systems may be valuable for both reducing the required area and the contamination; therefore, CWs are a promising option for sustainable landfill leachate treatment systems in developing tropical regions.  相似文献   
32.
Some invasive ants form large networks of mutually non-aggressive nests, i.e., supercolonies. The Argentine ant Linepithema humile forms much larger supercolonies in introduced ranges than in its native range. In both cases, it has been shown that little gene flow occurs between supercolonies of this species, though the mechanism of gene flow restriction is unknown. In this species, queens do not undertake nuptial flight, and males have to travel to foreign nests and cope with workers before gaining access to alien queens. In this study, we hypothesized that male Argentine ants receive interference from workers of alien supercolonies. To test this hypothesis, we conducted behavioral and chemical experiments using ants from two supercolonies in Japan. Workers attacked males from alien supercolonies but not those from their own supercolonies. The level of aggression against alien males was similar to that against alien workers. The frequency of severe aggression against alien males increased as the number of recipient workers increased. Cuticular hydrocarbon profiles, which serve as cues for nestmate recognition, of workers and males from the same supercolony were very similar. Workers are likely to distinguish alien males from males of their own supercolony using the profiles. It is predicted that males are subject to considerable aggression from workers when they intrude into the nests of alien supercolonies. This may be a mechanism underlying the restricted gene flow between supercolonies of Argentine ants. The Argentine ant may possess a distinctive reproductive system, where workers participate in selecting mates for their queens. We argue that the aggression of workers against alien males is a novel form of reproductive interference.  相似文献   
33.
Kitada Y  Kawahata H  Suzuki A  Oomori T 《Chemosphere》2008,71(11):2082-2090
To investigate the deteriorating health of coral reefs in Okinawa, Japan, natural sediment samples were analyzed for diuron, Irgarol 1051, chlorpyrifos, and bisphenol A (BPA) which are hazardous to corals. Samples were analyzed by solid-phase extraction (SPE) followed by high-performance liquid chromatography with tandem mass spectrometry (LC–MS–MS). Although diuron and chlorpyrifos usage is only well recorded for farms and not for cities, these chemicals were detected in both rural and urban areas. Additionally, diuron concentration in urban areas was in some cases higher than in rural areas, which might be caused by greater consumption of these chemicals in home gardens in city areas. Irgarol 1051 was detected in downstream river areas, which are situated far from the source sites such as pier or fishery harbor (0.6–3.2 km). This result suggested that Irgarol 1051 could be transported from the river mouths to the sampling sites during flood tides. High BPA concentrations were associated with urban areas (<1.2–22.0 μg kg−1), while low concentrations were associated with rural areas (nd–6.8 μg kg−1). The river sediments under study are delivered to coral reefs in large quantity through runoff caused by typhoons and other heavy rains. The highly hazardous chemicals are carried into coral reefs on these sediments. Therefore, these hazardous chemical substances may already be influencing the coral reefs.  相似文献   
34.
Journal of Material Cycles and Waste Management - In the original publication of the article, Eq.&nbsp;5 was published incorrectly. The correct equation is given below.  相似文献   
35.
Microbial fuel cells (MFCs) have gained a lot of attention recently as a mode of converting organic matter into electricity. In this study, a compost-based microbial fuel cell that generates bioelectricity by biodegradation of organic matter is developed. Grass cuttings, along with leaf mold, rice bran, oil cake (from mustard plants) and chicken droppings (waste from chickens) were used as organic waste. The electric properties of the MFC under anaerobic fermentation condition were investigated along with the influence of different types of membranes, the mixing of fly ash, and different types of electrode materials. It is observed that the maximum voltage was increased by mixing fly ash. Cellophane showed the highest value of voltage (around 350 mV). Bamboo charcoal is good for anode material; however carbon fiber is better for the cathode material in terms of optimization of power generated. This developed MFC is a simple cell to generate electricity from organic waste.  相似文献   
36.
Japanese medaka (Oryzias latipes) has been widely used for the evaluation of the toxicity of endocrine active chemicals (EACs) and other chemicals as well as for monitoring the adverse effects of effluent discharges in relation to sexual development and function. It is useful for these evaluations for many reasons including the following: 1) it has a short life cycle facilitating studies extending over long phases of development and over multigenerations, 2) it is easy to rear, 3) male and female phenotypes can easily be distinguished on the basis of secondary sex characteristics, and 4) a genetic marker (DMY) is available for identifying the true genotypic sex. Several biomarkers have been found to be useful for identifying the effects of exposure to estrogenic and androgenic chemicals in medaka and they include increased levels of hepatic vitellogenin (VTG) and testis-ova induction in males for exposure to estrogenic chemicals, and decreased levels of hepatic VTG in females and an altered morphology of dorsal and anal fins and formation of papillae for androgenic chemicals. In this paper, we present a critical analysis of the use of medaka as a test species for studies of endocrine disruption and report on the use of sex-related genetic markers and alterations in gonadal development, including the induction of testis-ova formation, for assessing the disruptive effects of EACs. In this paper, we focus on some of the more recent studies and findings.  相似文献   
37.
A long-term monitoring of composition of landfill gases in the region with high rainfall was conducted using an argon assay in order to discuss air intrusion into the dump site. Gas samples were taken from vertical gas monitoring pipes installed along transects at two sections (called new and old) of an abandoned waste dump site in Sri Lanka. N2O concentrations varied especially widely, by more than three orders of magnitude (0.046–140 ppmv). The nitrogen/argon ratio of landfill gas was normally higher than that of fresh air, implying that denitrification occurred in the dump site. Argon assays indicate that both N2 and N2O production occurred inside waste and more significantly in the old section. The Ar assay would help for evaluations of N2O emission in developing countries.

Implications: A long-term monitoring of composition of landfill gases in the region with high rainfall was conducted using an argon assay in order to discuss air intrusion into the dump site. Argon assays indicate that both N2 and N2O production occurred inside waste and more significantly in the old section.  相似文献   

38.
Congener profiles of PCB and a proposed new set of indicator congeners   总被引:2,自引:0,他引:2  
Ishikawa Y  Noma Y  Mori Y  Sakai S 《Chemosphere》2007,67(9):1838-1851
In this study, a new method for calculating total PCB and toxic equivalents (TEQ) of coplanar PCB (Co-PCB) was proposed, called the 'PCB dual method'. This method analysed various kinds of technical PCB, samples contaminated by technical PCB and byproduct PCB. In the PCB dual method, a data set of 15 indicator congeners was utilized for the calculations, having IUPAC nos. #3, #8, #28, #52, #77, #101, #105, #118, #126, #138, #153, #180, #194, #206 and #209. The 15 congener set was chosen from the major congeners, determined by HRGC/HRMS analysis, in 18 technical PCB, Kanechlor, Aroclor, Clophen and Chlorofen, and 20 other samples, such as indoor air, flue gases, emission gases, municipal solid waste (MSW), ash and sealant. To obtain total PCB and TEQ of Co-PCB, the intermediate sum for the concentration of the 15 congeners was multiplied by each multiplication factor. As a result, we obtained the average factor used to calculate total PCB in technical PCB and other samples. For technical PCB, the factor was 3.01, while for indoor air samples, flue and emission gases, MSW, ash and sealants, the factors were 3.92, 4.16, 3.68, 4.52 and 4.77, respectively. Moreover, the factor used to calculate the TEQ of Co-PCB in Kanechlor and other source samples were also obtained. The factors for Kanechlor, indoor air samples and emission gases from a cement plant were in the order of 10(-5), while the factor for flue gases in a MSW incinerator was in the order of 10(-3). These data were valuable for the rough estimation of the TEQ of Co-PCB without separation from other PCB before individual measurements.  相似文献   
39.
Nine polychlorinated biphenyl (PCB) congeners (2-chlorobiphenyl, 3-chlorobiphenyl, 4-chlorobiphenyl, 2,3,4-trichlorobiphenyl, 2,2',5,5'-tetrachlorobiphenyl, 2,3',4,4',5-pentachlorobiphenyl, 3,3',4,4',5-pentachlorobiphenyl, 2,2',4,4',5,5'-hexachlorobiphenyl, and decachlorobiphenyl) were dechlorinated by the sodium dispersion method (SD) at low temperature (60 degrees C). The dechlorination of 4-chlorobiphenyl was the fastest among the three monochlorobiphenyls. As for the other six congeners, we investigated the major dechlorination pathways. Although reaction selectivity was not very sensitive to the position of the chlorine substituent, the chlorines at the para position were slightly easier to dechlorinate than those at the ortho or meta positions. The decomposition rate increased with the total numbers of chlorine substituents. A chlorine situated between two other chlorines showed a high reactivity. When the numbers of chlorines on each of the phenyl rings were different, the reactions occurred on the more substituted ring. In the degradation of 4-chlorobiphenyl at elevated temperature (160 degrees C), we investigated the structures of the polymerized products and whether all the organic chlorinated compounds degraded finally or not. As for the dimers, p-quarterphenyl (QP) and m,p-QP were detected but not o-QP, m-QP, o,p-QP, o,m-QP, or the mono- to tetra-chlorinated QPs. Compounds with a molecular weight of 534.4183 or 758.6713 were detected. They were considered to have C40H54 or C56H86 as their molecular formula. The compounds were most probably the polymerized products resulting from coupling of hexadecane or two hexadecanes and two phenylcyclohexadienes. It was thought the dechlorination and the polymerization were the main reactions. All of many detected compounds were hydrocarbons without chlorines, and no peaks originating from organic chlorinated compounds were observed by mass spectroscopic (MS) methods.  相似文献   
40.
To improve U.S. air quality, there are many regulations on-the-way (OTW) and on-the-books (OTB), including mobile source California Low Emission Vehicle third generation (LEV III) and federal Tier 3 standards. This study explores the effects of those regulations by using the U.S. Environmental Protection Agency's (EPA) Community Multiscale Air Quality (CMAQ) model for 8-hr ozone concentrations in the western and eastern United States in the years 2018 and 2030 during a month with typical high ozone concentrations, July. Alterations in pollutant emissions can be due to technological improvements, regulatory amendments, and changes in growth. In order to project emission rates for future years, the impacts of all of these factors were estimated. This study emphasizes the potential light-duty vehicle emission changes by year to predict ozone levels. The results of this study show that most areas have decreases in 8-hr ozone concentrations in the year 2030, although there are some areas with increased concentrations. Additionally, there are areas with 8-hr ozone concentrations greater than the current U.S. National Ambient Air Quality Standard level, which is 75 ppb.

Implications:

To improve U.S. air quality, many regulations are on the way and on the books, including mobile source California LEV III and federal Tier 3 standards. This study explores the effects of those regulations for 8-hr ozone concentrations in the western and eastern United States in the years 2018 and 2030. The results of this study show that most areas have decreases in 8-hr ozone concentrations in 2030, although there are some areas with increased concentrations. Additionally, there are areas with 8-hr ozone concentrations greater than the current U.S. National Ambient Air Quality Standard level.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号