During the discharge of flashing liquids through leaks due to abrupt depressurization a transient thermodynamic non-equilibrium in the form of a boiling delay in the superheated liquid flow can occur. As a consequence the actual mass flow quality is smaller than calculated under the assumption of an immediate adjustment of the thermodynamic equilibrium between the phases. For the prediction of the leak mass flow for a given pressure difference the magnitude of this self-adjusting mass flow quality is needed.
Most of the models cited in the literature include only the equilibrium mass quality as limiting quantity and ignore further effects as that of the depressurization velocity or the mean nucleus distance. For the assessment of the maximum possible liquid superheat during flashing only the conduction heat transfer from a stagnant liquid to the bubble surface is used to describe the bubble growth.
The sub-model for the bubble growth due to expansion and mass transfer necessary for the global prediction of the transient thermodynamic non-equilibrium in flashing liquids was validated using bubble radii measured by Hooper et al. [Bubble growth and pressure relationship in the flashing of superheated water. Technical publication 6904, Mechanical Engineering Department, University of Toronto, 1969] for the case of a sudden depressurization of initially saturated water. On this basis the calculated time-dependent temperature field, the actual mass quality, the mean liquid temperature and, in comparison to the corresponding values based on the assumption of immediate thermodynamic equilibrium, the maximum possible liquid superheat are predicted. 相似文献
In 1992 a comprehensive health-promotion project was initiated in seven nursing-homes in the Netherlands. This project was designed to implement an ergonomic-educational programme, with the intention of reducing physical workload and to bring about safe working in order to prevent work-related musculoskeletal complaints. After a period of external support, employees of the nursing-homes should be able to proceed with the programme independently. In this paper the content of the programme and its underlying strategies and theories are described. So far, the programme has got off to a good start in all the nursing-homes. Positive effects of the programme could be demonstrated and guidelines and protocols for safe working were introduced. However, it is as yet too early for definitive conclusions to be drawn regarding the aspect of continuity. 相似文献
Pseudomonas putida was grown on a mixture of long-chain fatty acids obtained by hydrolysis of linseed oil. A poly(3-hydroxyalkanoate) containing
51.2% of unsaturated monomers was obtained. A considerable percentage (13.6%) was constituted by C14 and C16 monomers containing three double-bonds in the side chains. The polymer showed a high tendency to crosslink when it was kept
in presence of air. In the crosslinked polymer no polyunsaturated monomers could be detected. 相似文献
Car manufacturers must eliminate automotive shredder residues (ASR). Two ways of incineration are of interest: at 850°C in municipal waste incinerators or at higher temperatures, above 1100°C in cement plants. These processes reduce the mass and the volume of waste to be disposed of in landfills and energy recovery might be possible. Regulations govern the emission of gaseous effluents to control environmental risk. To determine gaseous effluents from a pilot sacle or an industrial incineration plant, an artificial ASR was made by mixing three representative organic polymers present in the real ASR, namely polyvinylchloride, polyurethane and rubber. This mixture was incinerated at 850 and 1100°C in laboratory experiments and the analyses of the principal gaseous effluents such as carbon oxides, nitrogen oxides, volatile organic compounds, hydrochloric and hydrocyanic acids and sulphur compounds are presented and discussed. Lastly, in order to simulate artificial ASR behaviour, the composition of the combustion gases at equilibrium was calculated using a Gibbs energy minimisation code. 相似文献
This paper presents detailed data on the thermal response of two 500 gal ASME code propane tanks that were 25% engulfed in a hydrocarbon fire. These tests were done as part of an overall test programme to study thermal protection systems for propane-filled railway tank-cars.
The fire was generated using an array of 25 liquid propane-fuelled burners. This provided a luminous fire that engulfed 25% of the tank surface on one side. The intent of these tests was to model a severe partially engulfing fire situation.
The paper presents data on the tank wall and lading temperatures and tank internal pressure. In the first test the wind reduced the fire heating and resulted in a late failure of the tank at 46 min. This tank failed catastrophically with a powerful boiling liquid expanding vapour explosion (BLEVE). In the other test, the fire heating was very severe and steady and this tank failed very quickly in 8 min as a finite rupture with massive two-phase jet release. The reasons for these different outcomes are discussed. The different failures provide a range of realistic outcomes for the subject tank and fire condition. 相似文献
This paper describes the results from a series of fire tests that were carried out to measure the effect of defects in thermal protection systems on fire engulfed propane pressure vessels.
In North America thermal protection is used to protect dangerous goods rail tank-cars from accidental fire impingement. They are designed so that a tank-car will not rupture for 100 min in a defined engulfing fire, or 30 min in a defined torching fire. One common system includes a 13 mm blanket of high-temperature ceramic fibre thermal insulation covered with a 3 mm steel jacket. Recent inspections have shown that some tanks have significant defects in these thermal protection systems. This work was done to establish what levels of defect are acceptable from a safety standpoint.
The tests were conducted using 1890 l (500 US gallon) ASME code propane pressure vessels (commonly called tanks in the propane industry). The defects tested covered 8% and 15% of the tank surface. The tanks were 25% engulfed in a fire that simulated a hydrocarbon pool fire with an effective blackbody temperature of 870 °C.
The fire testing showed that even relatively small defects can result in tank rupture if the defect area is engulfed in a severe fire, and the defect area is not wetted by liquid from the inside. A wall failure prediction technique based on uniaxial high-temperature stress rupture test data has been developed and agrees well with the observed failure times. 相似文献