There are numerous technologies currently being tested by EPA, universities throughout the world, and private research organizations. A few of the more promising innovative technologies as well as fully tested and proven remedies for treating contaminated groundwater are presented in this article. Although several of those technologies have been in existence for only four to five years, the results of full-scale testing are being produced. The method for each of these promising technologies is described, results from recent field-scale studies are summarized, and a discussion of cost is presented. 相似文献
Groundwater was being remediated with pump and treat technology at a facility where the groundwater was contaminated with commonly used degreaser solvents. Hydraulic conductivity of the heterogeneous residuum was beneficiated by applying pneumatic fracturing technology. The remedial system was controlled and monitored by a sophisticated remote telemetry system. A case history follows. 相似文献
Large cooking oil pool fires, occurring in industrial oil cookers, present a severe hazard to food processing plants due to their size and the large amount of hot oil involved. This paper reports a series of full-scale fire experiments conducted in a large industrial oil cooker mock-up. The characteristics of large cooking oil pool fires and the effect of oil depth and hood position in the oil cooker on fire growth were studied. The use of water mist for extinguishing large oil pool fires and their extinguishing performance under different discharge pressure and with different types of water mist systems were investigated. Experimental results showed that the cooking oil underwent a substantial expansion in volume during heating. The fires developed quickly once the oil auto-ignited. The fire growth rate was affected by the oil depth in the pan and the hood position in the oil cooker. The water mist fire suppression systems effectively extinguished large cooking oil fires and prevented them from re-igniting. Their extinguishing performance was determined by the type of water mist system, discharge pressure and hood position in the oil cooker. 相似文献
This paper presents detailed data on the thermal response of two 500 gal ASME code propane tanks that were 25% engulfed in a hydrocarbon fire. These tests were done as part of an overall test programme to study thermal protection systems for propane-filled railway tank-cars.
The fire was generated using an array of 25 liquid propane-fuelled burners. This provided a luminous fire that engulfed 25% of the tank surface on one side. The intent of these tests was to model a severe partially engulfing fire situation.
The paper presents data on the tank wall and lading temperatures and tank internal pressure. In the first test the wind reduced the fire heating and resulted in a late failure of the tank at 46 min. This tank failed catastrophically with a powerful boiling liquid expanding vapour explosion (BLEVE). In the other test, the fire heating was very severe and steady and this tank failed very quickly in 8 min as a finite rupture with massive two-phase jet release. The reasons for these different outcomes are discussed. The different failures provide a range of realistic outcomes for the subject tank and fire condition. 相似文献
Explosive gas mixtures and explosive dust clouds, once existing, exhibit similar ignition and combustion features. However, there are two basic differences between dusts and gases which are of substantially greater significance in design of safety standards than these similarities. Firstly, the physics of generation and up-keeping of dust clouds and premixed gas/vapour clouds are substantially different. This means that in most situations where accidental explosive gas clouds may be produced quite readily, generation of explosive dust clouds would be highly unlikely. Secondly, contrary to premixed gas flame propagation, the propagation of flames in dust/air mixtures is not limited only to the flammable dust concentration range of dynamic clouds. The state of stagnant layers/deposits offers an additional discrete possibility of flame propagation.
The two European Directives 94/9/EC (1994) and 1999/92/EC (1999) primarily address gases/vapours, whereas the particular properties of dusts are not addressed adequately. Some recent IEC and European dust standards resulting from this deficiency are discussed, and the need for revising the two directives accordingly is emphasized. 相似文献
After Bhopal disaster, emergency planning in an industrial area has become inevitable. The off-site emergency plan is an integral part of any major hazard control system. Boiling Liquid Expanding Vapour Explosion (BLEVE) leads to fatal consequences. This paper highlights some salient features of the emergency scenario, which ultimately leads to fireball with enormous pressure wave all around. 相似文献
This paper describes the results from a series of fire tests that were carried out to measure the effect of defects in thermal protection systems on fire engulfed propane pressure vessels.
In North America thermal protection is used to protect dangerous goods rail tank-cars from accidental fire impingement. They are designed so that a tank-car will not rupture for 100 min in a defined engulfing fire, or 30 min in a defined torching fire. One common system includes a 13 mm blanket of high-temperature ceramic fibre thermal insulation covered with a 3 mm steel jacket. Recent inspections have shown that some tanks have significant defects in these thermal protection systems. This work was done to establish what levels of defect are acceptable from a safety standpoint.
The tests were conducted using 1890 l (500 US gallon) ASME code propane pressure vessels (commonly called tanks in the propane industry). The defects tested covered 8% and 15% of the tank surface. The tanks were 25% engulfed in a fire that simulated a hydrocarbon pool fire with an effective blackbody temperature of 870 °C.
The fire testing showed that even relatively small defects can result in tank rupture if the defect area is engulfed in a severe fire, and the defect area is not wetted by liquid from the inside. A wall failure prediction technique based on uniaxial high-temperature stress rupture test data has been developed and agrees well with the observed failure times. 相似文献
As part of the NJ Toxics Reduction Workplan for NY-NJ Harbor, ambient water samples were collected at fifteen locations along
the tidal portions of the Hackensack, Passaic, Raritan, Rahway and Elizabeth Rivers, and in Newark Bay, the Arthur Kill, and
Kill van Kull. A Trace Organics Platform Sampler was used to collect a total of 75 suspended sediment phase samples between
June 2000 and May 2002. These samples were analyzed for spatial and wet vs. dry weather trends in the 17 polychlorinated dibenzo-p-dioxins
and dibenzofurans (PCDD/Fs; modified USEPA Method 1613b). Mean total PCDD/F (tPCDD/F) concentrations at the sampling locations
ranged between 3.8 and 41.5 ng/g. On average, OCDD accounted for almost 80% of the tPCDD/F concentrations; mean total [PCDD/F
– OCDD] concentrations ranged between 0.84 and 5.20 ng/g at the sampling locations. Mean 2,3,7,8-TCDD concentrations ranged
between 0.003 and 0.28 ng/g, with the highest concentrations (> 0.10 ng/g) along the tidal Passaic and lower Hackensack Rivers,
and in upper Newark Bay. Mean tPCDD/F Toxic Equivalency Quotients (TEQ) ranged between 45 and 344 TEQ pg/g, with the highest
levels found in the lower Passaic River. Toxicity was primarily driven by 2,3,7,8-TCDD concentrations in the Passaic and Hackensack
Rivers, and in Newark Bay. Examples of congener distribution patterns at some of the sampling locations are also presented. 相似文献
Ammonia emissions from two contrasting seabird colonies in Scotland were measured, based on the determination of atmospheric concentrations downwind of the colonies. Atmospheric concentrations of ammonia (NH3) across the downwind plume were compared with the inverse application of a Gaussian dispersion model (ID) to calculate the modelled NH3 emission that would generate the measured cross-wind-integrated plume concentration. In parallel, a tracer gas (sulphur hexafluoride, SF6) was released from the colonies with air samples taken to allow determination of SF6 concentrations. On the basis of the known emission rate of SF6, the magnitude of ammonia emissions was estimated by the cross-wind-integrated tracer ratio (TR) of NH3/SF6 concentrations. Coupled with data on annual bird attendance, the measurements indicate annual emissions from the Isle of May and the Bass Rock of 18 and 132 tonnes NH3-N year–1, respectively. The measured NH3 emissions were compared with estimates of seabird nitrogen excretion to estimate the proportion of excreted N that is volatilised as NH3 (FNr). The emission estimates of the two methods compared favourably, giving 4 and 6 kg NH3-N h–1 (FNr = 15%) for the Isle of May for the ID and TR methods, respectively, and 21 and 25 kg NH3-N h–1 (FNr = 50%) for the Bass Rock for the ID and TR methods, respectively. The results provide the first measurement-based estimates to allow regional up scaling of ammonia emissions from seabirds. 相似文献