首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   39篇
  免费   1篇
废物处理   2篇
环保管理   2篇
综合类   23篇
基础理论   2篇
污染及防治   10篇
评价与监测   1篇
  2021年   2篇
  2019年   1篇
  2016年   2篇
  2015年   2篇
  2014年   1篇
  2013年   7篇
  2012年   5篇
  2011年   1篇
  2010年   2篇
  2008年   2篇
  2006年   1篇
  2003年   1篇
  2002年   1篇
  2001年   3篇
  1987年   2篇
  1984年   2篇
  1983年   2篇
  1981年   1篇
  1967年   1篇
  1965年   1篇
排序方式: 共有40条查询结果,搜索用时 15 毫秒
31.
This paper presents information concerning the response to the availability of control program grants under Sect. 4 of the Clean Air Act, P.L. 88-206. Statistics concerning awards are presented together with a discussion of the nature of the projects supported and the impact of this support on air pollution control efforts throughout the country.  相似文献   
32.
The aim of the study was to investigate the rationale of the current indications for fetal chromosome analysis. 5372 women had 5423 amniocenteses performed, this group constituting a consecutive sample at the chromosome laboratory, Rigshospitalet, Copenhagen from March 1973 to September 1980 (Group A + B). Pregnant women 35 years of age, women who previously had a chromosomally abnormal child, families with translocation carriers or other heritable chromosomal disease, families where the father was 50 years or more and women in families with a history of Down's syndrome (group A), were compared to women having amniocentesis, although considered not to have any increased risk of fetal chromosome abnormality (1390 pregnancies, group B). They were also compared with 750 consecutive pregnancies in women 25–34 years of age, in whom all heritable diseases were excluded (group Q. The risk of unbalanced chromosome abnormality in group A (women with elevated risk) is significantly higher than in group B + C (women without elevated risk) (relative risk 2–4). Women with a known familial translocation and women 40 years or more have a relative risk of 5–7 of having an unbalanced chromosome abnormality compared with women without elevated risk. Spontaneous abortion rate and prematurity rate did not differ from rates expected without amniocentesis. It is concluded that current indications may be characterized as a mixture of evident high risk factors and factors with only a minor influence on risk. Indications for amniocentesis should therefore be reconsidered. Because it must be considered impractical and ethically wrong to limit amniocentesis to the two mentioned real high risk groups, and illogical to continue the present policy, which is not based on clearcut evidence, the possibility of offering amniocentesis to all who want it, is discussed. Screening for chromosome disease in all pregnancies is not without problems, but may be reasonable in some localities.  相似文献   
33.
A new culture vessel for amniotic fluid culture is presented (flaskette). It consists of a microscope slide, on top of which a culture chamber is mounted. Amniotic fluid cell cultures using in situ technique in the flaskette were compared to subcultured samples in ordinary (Falcon) tissue culture bottles. Working time was reduced by using this new culture vessel because of a very simple harvest procedure allowing simultaneous harvest of 15 samples. The interval between amniocentesis and harvest was shorter for the in situ technique than for the subcultivation technique. The frequency of aneuploidy in individual metaphases was higher with the subcultivation technique. while there was no difference in the frequency of structural anomalies.  相似文献   
34.
Among a population of 6305 pregnant women, aged 25 to 34 years and estimated to be at no increased risk of genetic disease in the fetus, 4606 women participated in a randomized controlled trial of genetic amniocentesis between 1980 and 1984. In the study group having amniocentesis (2264 women), 23 fetal chromosome abnormalities (1.0 per cent) were found: eight autosomal aneuploidies, seven sex chromosome aneuploidies, seven balanced structural rearrangements and one case of a marker some. The structural rearrangements and the marker chromosome were all shown to be inherited. The study group seemed representative for the whole population of younger women at low genetic risk. Therefore, a 1.0 per cent total rate of fetal chromosome abnormalities, consisting of one-third autosomal aneuploidies, one-third sex chromosome aneuploidies and one-third structural rearrangements, may be expected in the second trimester in younger low-risk women. In the same period of time, 562 women in the same age group were offered amniocentesis because of an estimated increased risk of fetal genetic disease. The total rate of fetal chromosome abnormality in this ‘high-risk’ group was 0.9 per cent and thus no different from the rate in the low-risk group.  相似文献   
35.
36.
37.
The NASN sampler for the collection of gaseous pollutants has been modified to increase its versatility and efficiency. Oxides of nitrogen are collected in bubblers employing a 70-100 μ frit with a collection efficiency of approximately 50% depending upon the frit porosity. Included in the sampler is a bubbler for the collection of aldehydes in which the aldehyde-MBTH complex is stable at least two weeks. This inert bubbler, which is constructed of polypropylene and Teflon, makes it possible for samples to be collected over the network and analyzed at a central laboratory. In addition, gaseous ammonia is collected in 0.1N H2SO4. This collecting system has an efficiency of greater than 85%. Low-level samples are analyzed automatically employing Nesslerization, whereas high-level samples from source emissions may be collected in indicating boric acid and titrated with 0.02N H2SO4. The sampler will accommodate either 50 or 100 ml polypropylene collecting tubes.  相似文献   
38.
An aerostat-borne instrument and sampling method was developed to characterize air samples from area sources, such as emissions from open burning. The 10 kg battery-powered instrument system, termed “the Flyer”, is lofted with a helium-filled aerostat of 4 m nominal diameter and maneuvered by means of one or two tethers. The Flyer can be configured variously for continuous CO2 monitoring, batch sampling of semi-volatile organic compounds (SVOCs), volatile organic compounds (VOCs), black carbon, metals, and PM by size. The samplers are controlled by a trigger circuit to avoid unnecessary dilution from background sampling when not within the source plume. The aerostat/Flyer method was demonstrated by sampling emissions from open burning (OB) and open detonation (OD) of military ordnance. A carbon balance approach was used to derive emission factors that showed excellent agreement with published values.  相似文献   
39.
A jet resonance-enhanced multiphoton ionization (REMPI) monitor was tested on a hazardous-waste-fired boiler for its ability to determine concentrations of polychlorinated dibenzodioxins and dibenzofurans (PCDDs/Fs). Jet REMPI is a real-time instrument capable of highly selective and sensitive (from parts per billion to parts per trillion) detection of a broad range of aromatic compounds, including a number of air toxic compounds. The PCDD/F toxic equivalency (TEQ) value was derived from a predetermined correlation (R 2 = 0.74) with monochlorobenzene (MClBz). This relationship was applied to nine subsequent jet REMPI on-line measurements of MClBz and parallel, standard extractive sampling for PCDD/F TEQ. For high waste-firing rates, with a range of PCDD/F TEQ values between 3.9 and 6.0 ng TEQ/m3, the TEQ values predicted by jet REMPI had a relative difference of 26% with the standard EPA Method 23 results. At low waste-firing rates (0.9–1.6 ng TEQ/m3), the relative difference increased to 219%. This limited testing shows that jet REMPI has promise as an on-line diagnostic monitor, providing feedback on the effects on PCDD/F emissions of operating parameter changes such as fuel feed interruptions or air pollution control failures.  相似文献   
40.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号