全文获取类型
收费全文 | 277篇 |
免费 | 4篇 |
国内免费 | 19篇 |
专业分类
安全科学 | 13篇 |
废物处理 | 29篇 |
环保管理 | 24篇 |
综合类 | 59篇 |
基础理论 | 42篇 |
污染及防治 | 99篇 |
评价与监测 | 21篇 |
社会与环境 | 10篇 |
灾害及防治 | 3篇 |
出版年
2023年 | 6篇 |
2022年 | 9篇 |
2021年 | 8篇 |
2020年 | 3篇 |
2019年 | 8篇 |
2018年 | 10篇 |
2017年 | 13篇 |
2016年 | 12篇 |
2015年 | 9篇 |
2014年 | 11篇 |
2013年 | 20篇 |
2012年 | 16篇 |
2011年 | 18篇 |
2010年 | 15篇 |
2009年 | 13篇 |
2008年 | 20篇 |
2007年 | 15篇 |
2006年 | 15篇 |
2005年 | 11篇 |
2004年 | 6篇 |
2003年 | 9篇 |
2002年 | 9篇 |
2001年 | 7篇 |
2000年 | 5篇 |
1999年 | 7篇 |
1998年 | 3篇 |
1997年 | 4篇 |
1994年 | 4篇 |
1993年 | 2篇 |
1991年 | 1篇 |
1990年 | 1篇 |
1988年 | 1篇 |
1987年 | 2篇 |
1984年 | 1篇 |
1979年 | 1篇 |
1977年 | 1篇 |
1964年 | 1篇 |
1961年 | 1篇 |
1958年 | 2篇 |
排序方式: 共有300条查询结果,搜索用时 15 毫秒
11.
12.
Yuh-Shan Ho 《Environmental science and pollution research international》2014,21(11):7234-7235
A research paper's contribution exists not only in its originality and creativity but also in its continuity and development for research that follows. However, the author easily ignores it. Citation error and quotation error occurred very frequently in a scientific paper. Numerous researchers use secondary references without knowing the original idea from authors. Sulaymon et al. (Environ Sci Pollut Res 20:3011–3023, 2013) and Spiridon et al. (Environ Sci Pollut Res 20:6367–6381, 2013) presented wrong pseudo-second-order models in Environmental Science and Pollution Research, vol. 20. This comment pointed the errors of the kinetic models and offered information for citing original idea of pseudo-second-order kinetic expression. In order to stop the proliferation of the mistake, it is suggested to cite the original paper for the kinetic model which provided greater accuracy and more details about the kinetic expression. 相似文献
13.
Ho SS Ho KF Lee SC Cheng Y Yu JZ Lam KM Feng NS Huang Y 《Journal of the Air & Waste Management Association (1995)》2012,62(2):221-234
Vehicular emission (VE) is one of the important anthropogenic sources for airborne carbonyls in urban area. Six types of VE-dominated samples were collected at representative locations in Hong Kong where polluted by a particular fueled type of vehicles, including (i) a gas refilling taxis station (liquefied petroleum gas [LPG] emission); (ii) a light-duty passenger car park (gasoline emission); (iii) a minibus station (diesel emission); (iv) a single-deck-bus depot (diesel emission); (v) a double-deck-bus depot (diesel emission); and (vi) a whole-food market entrance for light- and heavy-duty vehicles (diesel emission). A total of 15 carbonyls in the samples were quantified. Formaldehyde was the most abundant carbonyl among the VE-dominated samples, and its contribution to the total quantified amount on a molar basis ranged from 54.8% to 60.8%. Acetaldehyde and acetone were the next two abundant carbonyls. The carbonyls were quantified at three roadside locations in Hong Kong. The highest concentrations of formaldehyde and acetaldehyde, 22.7 +/- 8.4 and 6.0 +/- 2.8 microg/m3, respectively, were determined in the samples collected at a main transportation gate for goods between Hong Kong and Mainland China. The total quantified carbonyl concentration, 37.9 +/- 9.3 microg/m3, was the highest at an entrance of a cross-harbor tunnel in downtown area. The theoretical carbonyls compositions of the three roadside locations were estimated according to the VE-dominated sample profiles and the statistics on vehicle numbers and types during the sampling period. The measured compositions of formaldehyde were much higher than the theoretical compositions in summer, demonstrating that photochemical reactions significantly contributed to the formaldehyde production in the roadsides. 相似文献
14.
K. Baetens Q.T. Ho D. Nuyttens M. De Schampheleire A. Melese Endalew M.L.A.T.M. Hertog B. Nicolaï H. Ramon P. Verboven 《Atmospheric environment (Oxford, England : 1994)》2009,43(9):1674-1682
Correct field drift prediction is a key element in environmental risk assessment of spraying applications. A reduced order drift prediction model based on the diffusion–advection equation is presented. It allows fast assessment of the drift potential of specific ground boom applications under specific environmental wind conditions that obey the logarithmic wind profile. The model was calibrated based on simulations with a validated Computational Fluid Dynamics (CFD) model. Validation of both models against 38 carefully conducted field experiments is successfully performed for distances up to 20 m from the field edge, for spraying on flat pasture land. The reduced order model succeeded in correct drift predictions for different nozzle types, wind velocities, boom heights and spray pressures. It used 4 parameters representing the physical aspects of the drift cloud; the height of the cloud at the field edge, the mass flux crossing the field edge, the settling velocity of the droplets and the turbulence. For the parameter set and range considered, it is demonstrated for the first time that the effect of the droplet diameter distribution of the different nozzle types on the amount of deposition spray drift can be evaluated by a single parameter, i.e., the volume fraction of droplets with a diameter smaller than 191 μm. The reduced order model can be solved more than 4 orders of magnitude faster than the comprehensive CFD model. 相似文献
15.
Luis Carlos Belalcazar Oliver Fuhrer Minh Dung Ho Erika Zarate Alain Clappier 《Atmospheric environment (Oxford, England : 1994)》2009,43(36):5830-5837
Road traffic emissions, one of the largest source categories in megacity inventories, are highly uncertain. It is essential to develop methodologies to reduce these uncertainties to manage air quality more effectively. In this paper, we propose a methodology to estimate road traffic emission factors (EFs) from a tracer experiment and from roadside pollutants measurements. We emitted continuously during about 300 non-consecutive hours a passive tracer from a finite line source placed on one site of an urban street. At the same time, we measured continuously the resulting tracer concentrations at the other side of the street with a portable on-line gas chromatograph. We used n-propane contained in commercial liquid petroleum gas (LPG) as a passive tracer. Propane offers several advantages to traditional tracers (SF6, N2O, CFCs): low price, easily available, non-reactive, negligible global warming potential, and easy to detect with commercial on-line gas chromatographs.The tracer experiment was carried out from January to March 2007 in a busy street of Ho Chi Minh City (Vietnam). Traffic volume, weather information and pollutant concentrations were also measured at the measurement site. We used the results of the tracer experiment to calculate the dilution factors and afterwards we used these dilution factors, the traffic counts and the pollutant concentrations to estimate the EFs. The proposed method assumes that the finite emission line represents the emission produced by traffic in the full area of the street and therefore there is an error associated to this assumption. We use the Computational Fluids Dynamics (CFD) model MISKAM to calculate this error and to correct the HCMC EFs. EFs for 15 volatile organic compounds (VOCs) and NO are reported here. A comparison with available studies reveals that most of the EFs estimated here are within the range of EFs reported in other studies. 相似文献
16.
Lee CS Lim YW Kim HH Yang JY Shin DC 《Environmental science and pollution research international》2012,19(5):1629-1639
Background, aim, and scope
The purpose of this study was to monitor and present the heavy metal concentrations in the blood of residents of areas near municipal waste incinerators (MWIs), who are more prone to environmental pollution. We also sought to compare and analyze the residents?? perception of environmental pollution as one of the factors affecting heavy metal concentrations in the blood using a survey about the perceived damage caused by the facilities. Since heavy metal levels in the blood can be affected not only by local environmental pollution but also by personal and occupational factors, heavy metal levels in the blood need to be verified and consistently monitored.Methods
Residents who live within 300?m of MWIs in Seoul are acknowledged to be under indirect influence according to the Waste Disposal Act. A survey was given to 841 residents living within 300?m of a MWI from 2006 to 2009. The concentrations of heavy metals (lead, cadmium, and mercury) in the blood were measured in the 841 surveyed residents and in 105 residents in reference areas. Additionally, the perception of the damage caused by municipal waste incinerators was investigated using scores from 1 to 5 on a Likert scale.Results
The measurements of the heavy metal concentrations in the blood showed that the mean concentrations of lead, cadmium, and mercury were 43.1, 1.7, and 1.3?ug/L, respectively. The blood levels of lead and cadmium were slightly higher in the group of the subjects who had resided the longest near the municipal waste incinerators. When compared with the domestic investigation by the Ministry of Environment, the concentrations of lead and cadmium were a little higher, while that of mercury was a little lower. Overall, there was no significant difference in the distribution of heavy metal levels in the blood among age groups. Additionally, the investigation of the perceived damage from municipal waste incinerators showed that the subjects 相似文献17.
Perfluorinated compounds in the Pearl River and Yangtze River of China 总被引:27,自引:0,他引:27
So MK Miyake Y Yeung WY Ho YM Taniyasu S Rostkowski P Yamashita N Zhou BS Shi XJ Wang JX Giesy JP Yu H Lam PK 《Chemosphere》2007,68(11):2085-2095
A total of 14 perfluorinated compounds (PFCs) were quantified in river water samples collected from tributaries of the Pearl River (Guangzhou Province, south China) and the Yangtze River (central China). Among the PFCs analyzed, perfluorooctane sulfonate (PFOS) and perfluorooctanoic acid (PFOA) were the two compounds with the highest concentrations. PFOS concentrations ranged from 0.90 to 99 ng/l and <0.01–14 ng/l in samples from the Pearl River and Yangtze River, respectively; whereas those for PFOA ranged from 0.85 to 13 ng/l and 2.0–260 ng/l. Lower concentrations were measured for perfluorobutane sulfonate (PFBS), perfluorohexane sulfonate (PFHxS), perfluorooctanesulfoamide (PFOSA), perfluorohexanoic acid (PFHxA), perfluoroheptanoic acid (PFHpA), perfluorononaoic acid (PFNA), perfluorodecanoic acid (PFDA), and perfluoroundecanoic acid (PFUnDA). Concentrations of several perfluorocarboxylic acids, including perfluorododecanoic acid (PFDoDA), perfluorotetradecanoic acid (PFTeDA), perfluorohexadecanoic acid (PFHxDA) and perfluorooctadecanoic acid (PFOcDA) were lower than the limits of quantification in all the samples analyzed. The highest concentrations of most PFCs were observed in water samples from the Yangtze River near Shanghai, the major industrial and financial centre in China. In addition, sampling locations in the lower reaches of the Yangtze River with a reduced flow rate might serve as a final sink for contaminants from the upstream river runoffs. Generally, PFOS was the dominant PFC found in samples from the Pearl River, while PFOA was the predominant PFC in water from the Yangtze River. Specifically, a considerable amount of PFBS (22.9–26.1% of total PFC analyzed) was measured in water collected near Nanjing, which indicates the presence of potential sources of PFBS in this part of China. Completely different PFC composition profiles were observed for samples from the Pearl River and the Yangtze River. This indicates the presence of dissimilar sources in these two regions. 相似文献
18.
Seasonal variations of monocarbonyl and dicarbonyl in urban and sub-urban sites of Xi’an,China 总被引:1,自引:0,他引:1
K. F. Ho Steven Sai Hang Ho W. T. Dai J. J. Cao Ru-Jin Huang Linwei Tian W. J. Deng 《Environmental monitoring and assessment》2014,186(5):2835-2849
Seventeen airborne carbonyls including monocarbonyls and dicarbonyls were determined in urban and sub-urban sites of Xi’an, China in three seasons in 2010. In winter, acetone was the most abundant carbonyl in the urban site due to usage of organic solvents in constructions and laboratories and its slower atmospheric removal mechanisms by photolysis and reaction with hydroxyl radical than those of formaldehyde and acetaldehyde. In the sub-urban site, acetaldehyde was the most abundant carbonyl, followed by formaldehyde and acetone. During summer, however, formaldehyde was the most dominant carbonyl in both sites. The photooxidations of a wide range of volatile organic compounds (VOCs) yielded much more formaldehyde than other carbonyls under high solar radiation and temperature. In the urban site, the average concentrations of dicarbonyls (i.e., glyoxal and methyglyoxal) in spring and summer were higher than that in winter. Transformation of aromatic VOCs emitted from fuel evaporation leads to the formation of 1,2-dicarbonyls. A reverse trend was observed in sub-urban sites, as explained by the relatively low abundances and accumulations of VOC precursors in the rural atmosphere during warm seasons. Moreover, cumulative cancer risk based on measured outdoor carbonyls (formaldehyde and acetaldehyde) in Xi’an Jiaotong University and Heihe was estimated (8.82?×?10?5 and 4.96?×?10?5, respectively). This study provides a clear map on the abundances of carbonyls and their source interpretation in the largest and the most economic city in Northwestern China. 相似文献
19.
Tzu-Yi Pai C. L. Chen H. Chung H. H. Ho T. W. Shiu 《Environmental monitoring and assessment》2010,171(1-4):551-560
In this study, the variation of sewage quality was investigated and the active fraction of different microbial functional groups in biofilm was quantified in a 5.6-km trunk sewer line. The sewage quality including suspended solids, biochemical oxygen demand, total chemical oxygen demand (COD), total nitrogen, total Kjeldahl nitrogen, ammonia nitrogen, nitrite nitrogen, and nitrate nitrogen were measured and compared with the values in literatures. The results indicated that since the wastewater treatment plant was not operated at its full capacity, the concentrations of different compounds were lower compared with the values in literatures. The values of heterotrophic growth rate constant lay between 5.6 and 8.6 day???1. Its average value was 7.7 day???1. The values of heterotrophic lysis rate constant lay between 0.2 and 0.4 day???1. The active heterotrophic biomass in biofilm varied from 240 to 800 mg COD m???2 and average value was 497 mg COD m???2. The biofilm mass varied from 880 to 1,080 mg m???2. The percentage of heterotroph to biofilm mass fall within the range of 24.0–90.9% and average value was 52.9%. In the oxygen uptake rate batch tests, the biomass, growth rate constant, and lysis rate constant of autotroph could not be determined because the fraction of autotroph in biofilm was relatively few. It revealed that the degradation of organic matters, nitrification, and denitrification occurred in the trunk sewer line. But the results indicate that the condition seem favorable for nitrification. 相似文献
20.
Performance of an electrochemical COD (chemical oxygen demand) sensor with an electrode-surface grinding unit 总被引:2,自引:0,他引:2
Geun Jeong B Min Yoon S Ho Choi C Koang Kwon K Sik Hyun M Heui Yi D Soo Park H Kim M Joo Kim H 《Journal of environmental monitoring : JEM》2007,9(12):1352-1357
An electrochemical COD (chemical oxygen demand) sensor using an electrode-surface grinding unit was investigated. The electrolyzing (oxidizing) action of copper on an organic species was used as the basis of the COD measuring sensor. Using a simple three-electrode cell and a surface grinding unit, the organic species is activated by the catalytic action of copper and oxidized at a working electrode, poised at a positive potential. When synthetic wastewater was fed into the system, the measured Coulombic yields were found to be dependent on the COD of the synthetic wastewater. A linear correlation between the Coulombic yields and the COD of the synthetic wastewater was established (10-1000 mg L(-1)) when the electrode-surface grinding procedure was activated briefly at 8 h intervals. When various kinds of wastewater samples obtained from various sewage treatment plants were measured, linear correlations (r(2)> or = 0.92) between the measured EOD (electrochemical oxygen demand) value and COD of the samples were observed. At a practical wastewater treatment plant, the measurement system was successfully operated with high accuracy and good stability over 3 months. These experimental results show that the application of the measurement system would be a rapid and practical method for the determination of COD in water industries. 相似文献