全文获取类型
收费全文 | 129篇 |
免费 | 3篇 |
国内免费 | 11篇 |
专业分类
安全科学 | 4篇 |
废物处理 | 11篇 |
环保管理 | 15篇 |
综合类 | 32篇 |
基础理论 | 10篇 |
污染及防治 | 50篇 |
评价与监测 | 16篇 |
社会与环境 | 4篇 |
灾害及防治 | 1篇 |
出版年
2022年 | 2篇 |
2021年 | 2篇 |
2020年 | 2篇 |
2019年 | 3篇 |
2018年 | 1篇 |
2017年 | 7篇 |
2016年 | 11篇 |
2015年 | 7篇 |
2014年 | 8篇 |
2013年 | 11篇 |
2012年 | 11篇 |
2011年 | 10篇 |
2010年 | 5篇 |
2009年 | 8篇 |
2008年 | 5篇 |
2007年 | 16篇 |
2006年 | 7篇 |
2005年 | 7篇 |
2004年 | 10篇 |
2003年 | 6篇 |
2002年 | 3篇 |
2001年 | 1篇 |
排序方式: 共有143条查询结果,搜索用时 0 毫秒
11.
Eight samples of processed food salt collected from five plants in Korea were analyzed for 2,3,7,8-substituted polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) using liquid-liquid extraction, clean-up procedures, and high resolution gas chromatography-high resolution mass spectrometry. The study included the analyses of two kinds of salt product sample: bamboo-salt and parched salt. The levels of toxic PCDD/Fs found in the salt product samples were extremely low: the results revealed TEQ levels ranging between the sub pg TEQ/g and sub fg TEQ/g. The differences in the TEQ values of toxic PCDD/F were observed between the salt product samples, which were treated with different frequency of baking using four different fuels (firewood, pine wood, pine resin, and indirect heating by gas) at temperatures from 300 to 2000 degrees C. In bamboo-salt samples, the concentrations and TEQ values of toxic PCDD/Fs ranged between 0.57-66 pg/g and 5.7x10(-5)-0.64 pg TEQ/g, respectively. PCDD/Fs levels in bamboo-salts baked by firewood were found to be higher than those baked by pinewood or pine resin. In parched salt samples, the concentrations and TEQ values of toxic PCDD/Fs ranged between 0.97-3.7 pg/g and 0.0097-0.017 pg TEQ/g, respectively. The data was discussed regarding the concentration and the distribution pattern of congeners. 相似文献
12.
13.
Sang Tae Chung Yi Yoon Hye Jeong Park 《Journal of Loss Prevention in the Process Industries》2013,26(6):1679-1684
Improvised explosive devices (IEDs) have become an alternative method for terrorists or criminals who face difficulties in obtaining traditional explosives as threatening tools. The ease of obtaining precursor materials from commodity chemicals in the free market and the ease of generating bombs through the hands of novices have created problems. Controlling the potential precursors to defeat illegal acquisition is not trivial due to their widespread use as common merchandise among chemical industries and consumers. However, efforts to identify the potential precursors may be the first step for devising appropriate control measures. In this study, we proposed a systematic screening method for identifying potential IED precursors (IEDPs) from commodity chemicals, which are regulated by Korean controls. We identified 25 potential IEDPs from 3980 candidate chemicals that can be diverted into IEDs or homemade bombs but are not likely to be solely used as an IED. We also developed a methodology of prioritizing the potential precursor chemicals to assess the urgency of controls using a scoring system with four criteria: previous listing as an official precursor; past record of being encountered in criminal use; volume of commercial circulation, which denotes the probability of exposure to individuals; and the degree of regulatory counter-measures against illegal acquisitions that are currently effective in Korea. 相似文献
14.
Jung Hwan Oh Eui-Jong Lee Jeong Ik Oh Jong-Oh Kim Am Jang 《Environmental science and pollution research international》2016,23(8):7074-7080
As cities are becoming increasingly aware of problems related to conventional mobile collection systems, automated pipeline-based vacuum collection (AVAC) systems have been introduced in some densely populated urban areas. The reasons are that in addition to cost savings, AVAC systems can be efficient, hygienic, and environmentally friendly. Despite difficulties in making direct comparisons of municipal waste between a conventional mobile collection system and an AVAC system, it is meaningful to measure the quantities in each of these collection methods either in total or on a per capita generation of waste (PCGW, g/(day*capita)) basis. Thus, the aim of this study was to assess the difference in per capita generation of household waste according to the different waste collection methods in Korea. Observations on household waste show that there were considerable differences according to waste collection methods. The value of per capita generation of food waste (PCGF) indicates that a person in a city using AVAC produces 60 % of PCGF (109.58 g/(day*capita)), on average, compared with that of a truck system (173.10 g/(day*capita)) as well as 23 %p less moisture component than that with trucks. The value of per capita generation of general waste (PCGG) in a city with an AVAC system showed 147.73 g/(day*capita), which is 20 % less than that with trucks delivered (185 g/(day*capita)). However, general waste sampled from AVAC showed a 35 %p increased moisture content versus truck delivery. 相似文献
15.
Moon Seong Rang Min Goo Kang Seung Woo Park Jeong Jae Lee Ryung Hak Yoo 《Journal of the American Water Resources Association》2006,42(2):473-486
The main focus of this study was to compare the Grey model and several artificial neural network (ANN) models for real time flood forecasting, including a comparison of the models for various lead times (ranging from one to six hours). For hydrological applications, the Grey model has the advantage that it can easily be used in forecasting without assuming that forecast storm events exhibit the same stochastic characteristics as the storm events themselves. The major advantage of an ANN in rainfall‐runoff modeling is that there is no requirement for any prior assumptions regarding the processes involved. The Grey model and three ANN models were applied to a 2,509 km2 watershed in the Republic of Korea to compare the results for real time flood forecasting with from one to six hours of lead time. The fifth‐order Grey model and the ANN models with the optimal network architectures, represented by ANN1004 (34 input nodes, 21 hidden nodes, and 1 output node), ANN1010 (40 input nodes, 25 hidden nodes, and 1 output node), and ANN1004T (14 input nodes, 21 hidden nodes, and 1 output node), were adopted to evaluate the effects of time lags and differences between area mean and point rainfall. The Grey model and the ANN models, which provided reliable forecasts with one to six hours of lead time, were calibrated and their datasets validated. The results showed that the Grey model and the ANN1010 model achieved the highest level of performance in forecasting runoff for one to six lead hours. The ANN model architectures (ANN1004 and ANN1010) that used point rainfall data performed better than the model that used mean rainfall data (ANN1004T) in the real time forecasting. The selected models thus appear to be a useful tool for flood forecasting in Korea. 相似文献
16.
A micromodel analysis of factors influencing NAPL removal by surfactant foam flooding 总被引:3,自引:0,他引:3
A methodology to study the trichloroethylene (TCE) and dodecane removal in porous media by surfactant foams (SF) was presented by using etched-glass micromodels. The purpose of this work was to systematically evaluate the impact of various physicochemical factors such as gas fraction (GF), surfactant concentration, pore structure and nonaqueous phase liquid (NAPL) types on NAPL removal during SF flooding. The TCE displacement by SF was dependent on the gas fraction of SF. Low GFs (50% and 66%) were more efficient for TCE removal and sweep efficiencies than a high GF (85%). An increase in TCE removal was observed with increasing surfactant concentration at a fixed GF. TCE removal by SF flooding appeared to be dependent more to the value of Capillary number rather than to the concentration of surfactant solution. The effect of the pore heterogeneity was evaluated by employing two different types of micromodels. The Capillary number is an important parameter in the determination of sweep efficiency or gas saturation of SF in a nonhomogeneous porous medium. However, the TCE removal from a nonhomogeneous porous medium may not be associated with sweep efficiency. The initial configuration of residual TCE blobs in a nonhomogeneous porous medium would also be influential in displacing TCE. Sweep efficiencies and pressure responses of two NAPL systems (TCE and dodecane) were monitored to evaluate foam stability when the foam contacts the NAPLs. Stable foam contacting with TCE is implied, while it appears that dodecane cause the SF to collapse. All results indicate that the Capillary number (a ratio of viscous forces to capillary forces) is the most important parameter for TCE removal by SF flooding. Micromodel visualizations of water, surfactant and SF floods were showed and also discussed. 相似文献
17.
Performance of an electrochemical COD (chemical oxygen demand) sensor with an electrode-surface grinding unit 总被引:2,自引:0,他引:2
Geun Jeong B Min Yoon S Ho Choi C Koang Kwon K Sik Hyun M Heui Yi D Soo Park H Kim M Joo Kim H 《Journal of environmental monitoring : JEM》2007,9(12):1352-1357
An electrochemical COD (chemical oxygen demand) sensor using an electrode-surface grinding unit was investigated. The electrolyzing (oxidizing) action of copper on an organic species was used as the basis of the COD measuring sensor. Using a simple three-electrode cell and a surface grinding unit, the organic species is activated by the catalytic action of copper and oxidized at a working electrode, poised at a positive potential. When synthetic wastewater was fed into the system, the measured Coulombic yields were found to be dependent on the COD of the synthetic wastewater. A linear correlation between the Coulombic yields and the COD of the synthetic wastewater was established (10-1000 mg L(-1)) when the electrode-surface grinding procedure was activated briefly at 8 h intervals. When various kinds of wastewater samples obtained from various sewage treatment plants were measured, linear correlations (r(2)> or = 0.92) between the measured EOD (electrochemical oxygen demand) value and COD of the samples were observed. At a practical wastewater treatment plant, the measurement system was successfully operated with high accuracy and good stability over 3 months. These experimental results show that the application of the measurement system would be a rapid and practical method for the determination of COD in water industries. 相似文献
18.
Choi JH Kim YH Joo DJ Choi SJ Ha TW Lee DH Park IH Jeong YS 《Journal of the Air & Waste Management Association (1995)》2003,53(1):92-101
The characteristics of ammonia removal by two types of biofilter (a standard biofilter with vertical gas flow and a modified biofilter with horizontal gas flow) were investigated. A mixture of organic materials such as compost, bark, and peat was used as the biofilter media based on the small-scale column test for media selection. Complete removal capacity, defined as the maximum inlet load of ammonia that was completely removed, was obtained. The modified biofilter showed complete removal up to 1.0 g N/kg dry material/day. However, the removal capacity of the standard biofilter started to deviate from complete removal around 0.4 g N/kg dry material/day, indicating that the modified biofilter system has higher removal efficiency than the standard upflow one. In kinetic analysis of the biological removal of ammonia in each biofilter system, the maximum removal rate, Vm, was 0.93 g N/kg dry material/day and the saturation constant, Ks, was 32.55 ppm in the standard biofilter. On the other hand, the values of Vm and Ks were 1.66 g N/kg dry material/day and 74.25 ppm, respectively, in the modified biofilter system. 相似文献
19.
20.
A conjoint analysis of gut contents and stable C and N isotopes was applied to determine the main food sources and feeding habits of dominant amphipods in an eelgrass bed (Zostera marina) in Gwangyang Bay, Korea. Gut content observations demonstrated that, while Gammaropsis japonicus and Jassa slatteryi are herbivorous, feeding on epiphytes and detritus, Pontogeneia rostrata and Monocorophium acherusicum are omnivorous, feeding on mesozooplankton fragments and detritus. Stable isotope data confirmed that epiphytes, detritus, and mesozooplankton fragments were major food sources for amphipods in the eelgrass bed. Isotopic mixing model calculations clearly showed an interspecific difference in diet composition. A high isotopic dissimilarity between amphipod taxa demonstrated interspecific trophic diversity, reflecting their herbivorous (G. japonicus and J. slatteryi) and omnivorous (P. rostrata and M. acherusicum) feeding habits and confirmed the detrivorous feeding habits of caprellids. Such trophic diversity at interspecific level of the amphipod species indicates that they use different food resources within their microhabitats and play species-specific functional roles as mediators in trophic pathways from producers to higher-level consumers of the eelgrass ecosystem. Finally, our findings suggest that information on the species-specific trophic ecology of amphipods is needed to better understand their potential role in the trophic dynamics and carbon flow of seagrass bed ecosystems. 相似文献