首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   46篇
  免费   2篇
安全科学   3篇
废物处理   2篇
环保管理   5篇
综合类   6篇
基础理论   6篇
污染及防治   17篇
评价与监测   7篇
社会与环境   2篇
  2018年   2篇
  2017年   2篇
  2016年   4篇
  2014年   2篇
  2013年   10篇
  2011年   3篇
  2009年   2篇
  2008年   5篇
  2007年   2篇
  2006年   2篇
  2005年   1篇
  2004年   1篇
  2003年   1篇
  2002年   1篇
  2000年   3篇
  1999年   1篇
  1998年   1篇
  1994年   1篇
  1992年   1篇
  1991年   1篇
  1984年   1篇
  1982年   1篇
排序方式: 共有48条查询结果,搜索用时 15 毫秒
21.
Abstract

International cooperation and diffusion of environmental technologies is a central goal of the U.S. EPA Environmental Technology Initiative, and is of great interest to many countries. One objective is to exchange knowledge and skills concerning new monitoring technologies. In this case, the technology was open path Fourier Transform Infrared Spectrometry (op-FTIR).

Taiwan is a high-technology, newly industrialized country. Because of air pollution problems, it is interested in obtaining skills, knowledge, and instrumentation for monitoring air pollutants. In April 1994, the Industrial Technology Research Institute, Center for Industrial Safety and Health Technology (ITRI/CISH) in Hsinchu, Taiwan, requested intensive training in op-FTIR. Training was held between September 30,1994 and October 29,1994.

During the stay, the instructor provided intensive training on op-FTIR theory as well as an introduction to available instrumentation and software. The training concluded with a field demonstration of the instrumentation in a manufacturing facility. This report gives an overview of the training methods, structure, and materials in the op-FTIR training course. It will also address various problems encountered while teaching this course. In addition, the potential use for this technology in industry as well as by the Taiwanese government will be explained.  相似文献   
22.
23.
24.
Researchers have applied open path optical sensing techniques to a variety of workplace and environmental monitoring problems. Usually these data are reported in terms of a path-average (or path-integrated) concentration. When assessing potential human exposures along a beam path, this path-average value is not always informative, since concentrations along the path can vary substantially from the beam average. The focus of this research is to arrive at a method for estimating the upper-bound in contaminant concentrations over a fixed open beam path. The approach taken here uses a statistical model to estimate an upper-bound concentration based on a combination of the path-average and a measure of the spatial variability computed from point samples along the beam path. Results of computer simulations and experimental testing in a controlled ventilation chamber indicate that the model produced conservative estimates for the maximum concentration along the beam path. This approach may have many applications for open path monitoring in workplaces or wherever maximum concentrations are a concern.  相似文献   
25.
26.
The purpose of this paper is to describe a scheme to electrically charge fine particles using electric and magnetic fields in conjunction with ionizing radiation. Once charged, particulate matter can be removed from the air stream by directly applying a transverse electric field. In addition, since electrostatic forces can assist filtration and wet collection systems, it may be possible to design new and improved filtration and wet scrubber systems using radiation charging. The objectives of this paper are: (1) to present expressions that predict the charge acquired by particles and (2) to present the results of preliminary experiments.  相似文献   
27.
Recent studies have shown large increases in vehicle emissions when the air conditioner (AC) compressor is engaged. Factors that affect the compressor-on percentage can have a significant impact on vehicle emissions and can also lead to prediction errors in current emissions models if not accounted for properly. During 1996 and 1997, the University of California, Riverside, College of Engineering-Center for Environmental Research and Technology (CE-CERT) conducted a vehicle activity study for the California Air Resources Board (CARB) in the Sacramento, CA, region. The vehicles were randomly selected from all registered vehicles in the region. As part of this study, ten vehicles were instrumented to collect AC compressor on/off data on a second-by-second basis in the summer of 1997. Temperature and humidity data were obtained and averaged on an hourly basis. The ten drivers were asked to complete a short survey about AC operational preferences. This paper examines the effects of temperature, humidity, refrigerant type, and driver preferences on air conditioning compressor activity. Overall, AC was in use in 69.1% of the trips monitored. The compressor was on an average of 64% of the time during the trips. The personal preference settings had a significant effect on the AC compressor-on percentage but did not interact with temperature. The refrigerant types, however, exhibited a differential response across temperature, which may necessitate separate modeling of the R12 refrigerant-equipped vehicles from the R134A-equipped vehicles. It should be noted that some older vehicles do get retrofitted with new compressors that use R134A; however, none of the vehicles in this study had been retrofitted.  相似文献   
28.
The objective of this study was to determine whether ultraviolet-light-emitting diodes (UV-LEDs) could serve as an efficient photon source for heterogeneous photocatalytic oxidation (PCO). An LED module consisting of 12 high-power UV-A (lambda max = 365 nm) LEDs was designed to be interchangeable with a UV-A fluorescent black light blue (BLB) lamp for a bench scale annular reactor packed with silica-titania composite (STC) pellets. Lighting and thermal properties of the module were characterized to assess its uniformity and total irradiance. A forward current (I(F)) of 100 mA delivered an average irradiance of 4.0 mW cm(-2) at a distance of 8 mm, which is equivalent to the maximum output of the BLB, but the irradiance of the LED module was less uniform than that of the BLB. The LED and BLB reactors were tested for the oxidization of ethanol (50 ppm(v)) in a continuous-flow-through mode with 0.94 sec residence time. At the same average irradiance, the UV-A LED reactor resulted in a lower CO2 production rate (19.8 vs. 28.6 nmol L(-1) s(-1)), lower ethanol removal (80% vs. 91%), and lower mineralization efficiency (28% vs. 44%) than the UV-A BLB reactor. Ethanol mineralization was enhanced with the increase of the irradiance at the catalyst surface. This result suggests that reduced ethanol mineralization in the LED reactor relative to the BLB reactor at the same average irradiance could be attributed to the nonuniform irradiance over the photocatalyst, that is, a portion of the catalyst was exposed to less than the average irradiance. The potential of UV-A LEDs may be fully realized by optimizing the light distribution over the catalyst and utilizing their instantaneous "on" and "off" feature for periodic irradiation. Nevertheless, our results also showed that the current UV-A LED module had the same wall plug efficiency (WPE) of 13% as that of the UV-A BLB, demonstrating that UV-A LEDs are a viable photon source both in terms of WPE and PCO efficiency.  相似文献   
29.
Abstract

Beam path average data from an Open Path Fourier Transform Infrared (OP-FTIR) spectrometer can be used to reconstruct two-dimensional concentration maps of the gas and vapor contaminants in workplaces and the environment using computed tomographic (CT) techniques. However, a practical limitation arises because in the past, multiple-source and detector units were required to produce a sufficient number of intersecting beam paths in order to reconstruct concentration maps. Such a system can be applied to actual field monitoring situations only with great expense and difficulty. A single monostatic OP-FTIR system capable of rapid beam movement can eliminate this deficiency. Instead of many source and detector units, a virtual source arrangement has been proposed using a number of flat mirrors and retroreflectors to obtain intersecting folded beam paths.

Three virtual source beam configurations generated for a single-beam steerable FTIR system were tested using 54 flat mirrors and four retroreflectors or 54 flat mirrors and 56 retroreflectors mounted along the perimeter walls of a typical 24- x 21-ft test room. The virtual source CT configurations were numerically evaluated using concentration maps created from tracer gas concentration distributions measured experimentally in a test chamber. Synthetic beam path integral data were calculated from the test maps and beam configurations. Computer simulations of different beam configurations were used to determine the effects of beam geometry. The effects of noise and peak-reducing artifacts were evaluated. The performance of the tomographic reconstruction strategy was tested as a function of concentration and concentration gradients.  相似文献   
30.
The reduction of pathogens and indicator organisms through secondary effluent filtration was investigated at six full-scale treatment facilities, ranging in capacity from 0.04 to 1 m3/s (1 to 25 mgd). Grab samples were assayed for pathogens (cultivable enteric viruses, Giardia, and Cryptosporidium) and indicator organisms (coliforms, enterococci, Clostridium perfringens, and coliphages) quarterly under peak flow conditions from each facility over the course of 1 calendar year. Log10 removals resulting from filtration averaged 0.3 to 0.8 log10 for cultivable enteric viruses, 0.4 to 1.5 log10 for protozoan parasites, 0.01 to 3.7 log10 for indicator bacteria, and 0.3 to 1.1 log10 for coliphages. In addition to filter design (cloth, monomedium shallow- or deep-bed, or dual-media filters), differences in reduction of pathogens and indicators could be attributed to the combined effects of hydraulic loading rates, chemical addition practices, backwashing and postbackwashing operating strategies, and the effectiveness of upstream biological treatment and sedimentation.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏