Bacillus sp. CL18 was investigated to propose a bioprocess for protease production using feathers as organic substrate. In feather broth (FB), containing feathers as sole organic substrate (1–100 g l?1), maximal protease production was observed at 30 g l?1 (FB30) after 6 days of cultivation, whereas increased feather concentrations negatively affected protease production and feather degradation. Protease production peaks were always observed earlier during cultivations than maximal feather degradation. In FB30, 80% of initial feathers mass were degraded after 7 days. Addition of glucose, sucrose, starch, yeast extract (2 g l?1), CaCl2, or MgCl2 (10 mmol l?1) to FB30 decreased protease production and feather degradation. FB30 supplementation with NH4Cl (1 g l?1) resulted in less apparent negative effects on protease production, whereas peptone (2 g l?1) increased protease yields earlier during cultivations (3 days). Through a central composite design employed to investigate the effects of peptone and NH4Cl (0.5–4.5 g l?1) on protease production and feather degradation, FB30 supplementation with peptone and NH4Cl (0.5–1.1 g l?1) increased protease production within a shorter cultivation time (5 days) and hastened complete feather degradation (6 days). Feather bioconversion concurs with sustainable production of value-added products.
Ingredients in home and personal care products, including UV filters and benzotriazoles, are high production volume chemicals extensively used in our daily life, despite several studies revealed their potential eco-toxicity and endocrine-disrupting capacity. Due to some features, such as high lipophilicity, low degradability, and persistence of many of these compounds, sediments can be considered a sink for them in the aquatic environment. In the present study, nine organic UV filters and three benzotriazoles were investigated for the first time in sediments from four urban rivers in Brazil. The contaminants were analyzed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The results revealed that octocrylene (OC), etylhexyl-methoxycinnamate (EHMC), benzophenone-3 (oxybenzone, BP3), and benzotriazole (BZT) were the predominant compounds adsorbed on the sediments, with concentrations ranging from 5.6 to 322.2 ng g−1 dry weight. The results reported in this work constitute the first data on the accumulation of polar benzotriazoles and lipophilic organic UV filters in sediments from Brazil.
There is concern about the hazard of acute residential CO exposures from portable gasoline-powered generators, which can result in death or serious adverse health effects in exposed individuals. To address this hazard, the U.S. Consumer Product Safety Commission has developed low CO emission prototype generators by adapting off-the-shelf emission control technologies onto commercially available generators. A series of tests was conducted to characterize the indoor CO concentrations resulting from portable generators operating in the attached garage of a research house under seven different test house/garage configurations. The tested generators include both unmodified and modified low CO emission prototypes. It was found that CO concentrations varied widely, with peak house CO concentrations ranging from under 10 ppm to over 10,000 ppm. The highest concentrations in the house resulted from operation of the unmodified generator in the garage with the garage bay door closed and the house access door open. The lowest concentrations resulted from operation of a modified low CO emission prototype in the garage with the garage bay door open and the house access door closed. These tests documented reductions of up to 98% in CO concentrations due to emissions from two low CO emission portable generators compared to a stock generator.
Implications: Improper portable generator use has caused 800 U.S. deaths in the past 14 years. Generators operated in attached garages can cause CO to quickly reach deadly levels. Two low-emission prototypes generators were tested and had CO emissions reduced by up to 98%. Low-emission generators can reduce the risk of consumer poisonings and deaths. 相似文献
A marginal abatement cost curve (MACC) traces out the relationship between the quantity of pollution abated and the marginal cost of abating each additional unit. In the context of air quality management, MACCs are typically developed by sorting control technologies by their relative cost-effectiveness. Other potentially important abatement measures such as renewable electricity, energy efficiency, and fuel switching (RE/EE/FS) are often not incorporated into MACCs, as it is difficult to quantify their costs and abatement potential. In this paper, a U.S. energy system model is used to develop a MACC for nitrogen oxides (NOx) that incorporates both traditional controls and these additional measures. The MACC is decomposed by sector, and the relative cost-effectiveness of RE/EE/FS and traditional controls are compared. RE/EE/FS are shown to have the potential to increase emission reductions beyond what is possible when applying traditional controls alone. Furthermore, a portion of RE/EE/FS appear to be cost-competitive with traditional controls.
Implications: Renewable electricity, energy efficiency, and fuel switching can be cost-competitive with traditional air pollutant controls for abating air pollutant emissions. The application of renewable electricity, energy efficiency, and fuel switching is also shown to have the potential to increase emission reductions beyond what is possible when applying traditional controls alone. 相似文献
Environmental Management - Parks and protected area managers use zoning to decrease interpersonal conflict between recreationists. Zoning, or segregation, of recreation—often by non-motorized... 相似文献
A novel membrane system, the Biomass Concentrator Reactor (BCR), was evaluated as an alternative technology for the treatment of municipal wastewater. Because the BCR is equipped with a membrane whose average poresize is 20 μm (18–28 μm), the reactor requires low-pressure differential to operate (gravity). The effectiveness of this system was evaluated for the removal of carbon and nitrogen using two identical BCRs, identified as conventional and hybrid, that were operated in parallel. The conventional reactor was operated under full aerobic conditions (i.e., organic carbon and ammonia oxidation), while the hybrid reactor incorporated an anoxic zone for nitrate reduction as well as an aerobic zone for organic carbon and ammonia oxidation. Both reactors were fed synthetic wastewater at a flow rate of 71 L d?1, which resulted in a hydraulic retention time of 9 h. In the case of the hybrid reactor, the recycle flow from the aerobic zone to the anoxic zone was twice the feed flow rate. Reactor performance was evaluated under two solids retention times (6 and 15 d). Under these conditions, the BCRs achieved nearly 100% mixed liquor solids separation with a hydraulic head differential of less than 2.5 cm. The COD removal efficiency was over 90%. Essentially complete nitrification was achieved in both systems, and nitrogen removal in the hybrid reactor was close to the expected value (67%). 相似文献
Industrialized waterways frequently contain nearshore hotspots of legacy polychlorinated biphenyl (PCB) contamination, with uncertain contribution to aquatic food web contamination. We evaluated the utility of estuarine forage fish as biosentinel indicators of local PCB contamination across multiple nearshore sites in San Francisco Bay. Topsmelt (Atherinops affinis) or Mississippi silverside (Menidia audens) contamination was compared between 12 targeted sites near historically polluted locations and 17 probabilistically chosen sites representative of ambient conditions. The average sum of 209 PCB congeners in fish from targeted stations (441 ± 432 ng g?1 wet weight, mean ± SD) was significantly higher than probabilistic stations (138 ± 94 ng g?1). Concentrations in both species were comparable to those of high lipid sport fish in the Bay, strongly correlated with spatial patterns in sediment contamination, and above selected literature thresholds for potential hazard to fish and wildlife. The highest concentrations were from targeted Central Bay locations, including Hunter’s Point Naval Shipyard (1347 ng g?1; topsmelt) and Stege Marsh (1337 ng g?1; silverside). Targeted sites exhibited increased abundance of lower chlorinated congeners, suggesting local source contributions, including Aroclor 1248. These findings indicate that current spatial patterns in PCB bioaccumulation correlate with historical sediment contamination due to industrial activity. They also demonstrate the utility of naturally occurring forage fish as biosentinels of localized PCB exposure. 相似文献
Catla gill cell line (ICG) was established from gill tissue of Indian major carp (Catla catla), a freshwater fish cultivated in India. The cell line was maintained in Leibovitz’s L-15 supplemented with 10% fetal bovine serum. These cells have been sub-cultured more than 55 passages over a period of 2 years. The ICG cell line consists predominantly of epithelial-like cells. The cells were able to grow at a wide range of temperatures from 24 °C to 32 °C with an optimum temperature of 28 °C. The growth rate of gill cells increased as the fetal bovine serum (FBS) proportion increased from 2% to 20% at 28 °C with optimum growth at the concentrations of 10% or 15% FBS. Amplification of mitochondrial gene 12s rRNA using primers specific to C. catla confirmed the origin of this cell line from C. catla. The cells were successfully cryopreserved and revived at passage numbers 25, 35, 45 and 55. The cytotoxicity of three metal salts (ZnCl2, CuSO4 and CdCl2) was assessed in ICG cell line using multiple endpoints such as MTT, Neutral Red assay, Alamar Blue assay and Coomassie Blue protein assay. Acute toxicity assay on fish were conducted by exposing C. catla for 96 h to three metal salts under static conditions. Statistical analysis revealed good correlation with r2 = 0.908–0.985 for all combinations between endpoints employed. Linear correlations between each in vitro EC50 and the in vivo LC50 data were highly significant. 相似文献
Abstract Dissipation, degradation and leaching of fresh 14C coumaphos, alkylated 14C coumaphos and aged residues of 14C coumaphos from vats were studied in alkaline sandy loam soil in soil columns in the field under subtropical conditions in Delhi for a year. Dissipation, degradation and bound residue formation was more in case of alkali treated coumaphos than fresh coumaphos. After 365 days total residues of fresh coumaphos accounted for 33.25% while that of alkali treated coumaphos was 19.12%. Bound residue formation was almost double in case of alkali treated coumaphos (18.95%) than fresh coumaphos (9.53%) after 150 days followed by release of bound residue in both the cases. The proportion of metabolites 4 ‐ methylumbelliferone, chlorferon and potasan collectively was 86.05% in fresh coumaphos extractable residues while the same was 91.74% in alkali treated coumaphos after 365 days. Aged residues from vats containing copper sulphate and buffer were found to be more persistent in soil as total residues remained were 95.58% in comparison with 83.09% total residues of aged residues from vats containing only buffer after 150 days of treatment. Copper sulphate seems to inhibit the degradatiion of coumaphos in soil by microorganisms. Chlorferon was the major metabolite in generally all the samples. Coumaphos did not leach below 10 cm in all the cases. 相似文献
Abstract A laboratory scale two‐stage sequencing batch reactor (TSSBR) was used to study the effectiveness of pH as a real‐time control parameter in swine wastewater treatment. A Ringlace media was inserted into the A/O (Anoxic/Oxic) reactor for bacteria immobilization. The TSSBR was subjected to three levels of organic loading. The pH and ORP (Oxidation Reduction Potential) patterns obtained were consistent with distinct features, enabling the real‐time control strategy to effectively set a flexible aeration time pending on influent concentration, hence resulting in flexible cycle time and HRT (Hydraulic Retention Time) for the system. The real‐time process ensured a removal efficiency of over 99% and 95%, respectively, for ammonia and TOC (Total Organic Carbon). For NO3‐‐N and PO4‐3, the run with influent TOC = 4,000 mg/L yielded the most efficient removal of 61% and 95%, respectively. Test results suggest that pH can be a viable tool for on‐line real‐time control of a biological treatment process. 相似文献