全文获取类型
收费全文 | 118篇 |
免费 | 1篇 |
国内免费 | 8篇 |
专业分类
安全科学 | 10篇 |
废物处理 | 10篇 |
环保管理 | 11篇 |
综合类 | 19篇 |
基础理论 | 25篇 |
污染及防治 | 39篇 |
评价与监测 | 11篇 |
社会与环境 | 2篇 |
出版年
2022年 | 3篇 |
2021年 | 5篇 |
2019年 | 4篇 |
2018年 | 10篇 |
2017年 | 7篇 |
2016年 | 6篇 |
2014年 | 4篇 |
2013年 | 19篇 |
2012年 | 6篇 |
2011年 | 10篇 |
2010年 | 6篇 |
2009年 | 11篇 |
2008年 | 11篇 |
2007年 | 6篇 |
2006年 | 3篇 |
2005年 | 4篇 |
2004年 | 4篇 |
2003年 | 1篇 |
2002年 | 2篇 |
2001年 | 4篇 |
2000年 | 1篇 |
排序方式: 共有127条查询结果,搜索用时 31 毫秒
111.
We conducted kinetic and equilibrium sorption experiments on removal of Zn(II) from aqueous solutions by scoria (a vesicular pyroclastic rock with basaltic composition) from Jeju Island, Korea, in order to examine its potential use as an efficient sorbent. The batch-type kinetic sorption tests under variable conditions indicated that the percentage of Zn(II) removal by scoria increases with decreasing initial Zn(II) concentration, particle size, and sorbate/sorbent ratio. However, the sorption capacity decreases with the decrease of the initial Zn(II) concentration and sorbate/sorbent ratio. Equilibrium sorption tests show that Jeju scoria has a larger capacity and affinity for Zn(II) sorption than commercial powdered activated carbon (PAC); at initial Zn(II) concentrations of more than 10mM, the sorption capacity of Jeju scoria is about 1.5 times higher than that of PAC. The acquired sorption data are better fitted to the Langmuir isotherm than the Freundlich isotherm. Careful examination of ionic concentrations in sorption batches suggests that the sorption behavior is mainly controlled by cation exchange and typically displays characteristics of 'cation sorption'. The Zn(II) removal capacity decreases when solution pH decreases because of the competition with hydrogen ions for sorption sites, while the Zn(II) removal capacity increases under higher pH conditions, likely due to hydroxide precipitation. At an initial Zn(II) concentration of 5.0mM, the removal increases from 70% to 96% with the increase of initial pH from 3.0 to 7.0. We recommend Jeju scoria as an economic and efficient sorbent for Zn(II) in contaminated water. 相似文献
112.
Long-term fate of the herbicide cinosulfuron in lysimeters planted with rice over four consecutive years 总被引:2,自引:0,他引:2
In order to elucidate the long-term fate of the sulfonylurea herbicide cinosulfuron, the 14C-labelled chemical was applied to a clay loam soil, encased in two lysimeters, 22 days after rice (Oryza sativa L.) transplanting, and rice plants were grown for four consecutive years. Throughout the experimental period, leaching through soil profiles, absorption and translocation by rice plants, and distribution of 14C by downward movement in the soil layers were clarified. The total volume of leachates collected through the lysimeter soil over the four years amounted to 168 and 146 L in lysimeters I and II, respectively. The leachates contained 2.43% and 2.99% of the originally applied 14C-radioactivity, corresponding to an average concentration of 0.29 and 0.41 microg/L as the cinosulfuron equivalent in lysimeters I and II, respectively. The total 14C-radioactivity translocated to rice plants in the third and fourth year was 0.69% and 0.60% (lysimeter I), and 1.02% and 0.84% (lysimeter II) of the 14C applied, respectively. Larger amounts of cinosulfuron equivalents (0.54-0.75%) remained in the straw in the fourth year than in any other parts. The 14C-radioactivities distributed down to a depth of 70 cm after four years were 56.71-57.52% of the 14C applied, indicating the continuous downward movement and degradation of cinosulfuron in soil. The non-extractable residues were more than 88% of the soil radioactivity and some 45-48% of them was incorporated into the humin fraction. The 14C-radioactivity partitioned into the aqueous phase was nearly 30% of the extractable 14C, suggesting strongly that cinosulfuron was degraded into some polar products during the experimental period. It was found out in a supplemental investigation that flooding and constant higher temperature enhanced mineralization of [14C]cinosulfuron to 14CO2 in soil, indicating the possibility of chemical hydrolysis and microbial degradation of the compound in the flooded lysimeter soil. 相似文献
113.
Removal efficiencies of PCDDs/PCDFs by air pollution control devices in municipal solid waste incinerators 总被引:5,自引:0,他引:5
Kim SC Jeon SH Jung IR Kim KH Kwon MH Kim JH Yi JH Kim SJ You JC Jung DH 《Chemosphere》2001,43(4-7):773-776
Removal efficiencies of polychlorinated dibenzo-p-dioxins/polychlorinated dibenzofurans (PCDDs/PCDFs) by air pollution control devices (APCDs) in the commercial-scale municipal solid waste (MSW) incinerators with a capacity of above 200 ton/day were evaluated. The removal efficiencies of PCDDs/PCDFs were up to 95% when the activated carbon (AC) was injected in front of electrostatic precipitator (EP). Spray dryer absorber/bag filter (SDA/BF) had high removal efficiency (99%)) of PCDDs/PCDFs when a mixture of lime and AC was sprayed into the SDA. When the AC was not added in scrubbing solution, the whole congeners of PCDDs/PCDFs were enriched in the wet scrubber (WS) with negative removal efficiencies of -25% to -5731%. Discharge of PCDDs/PCDFs was decreased with increasing the proportions of AC added in scrubbing solution. Selective catalytic reduction (SCR) system had the removal efficiencies of up to 93% during the test operation. 相似文献
114.
Rando RJ Gibson RA Kwon CW Poovey HG Glindmeyer HW 《Journal of environmental monitoring : JEM》2005,7(7):675-680
A new analytical technique based on DRIFTS spectroscopy has been developed for the specific and sensitive determination of size-fractionated wood dust from 37 mm glass fiber filter samples collected with the Respicon sampler. A translational diffuse reflectance apparatus was modified to accept filter samples by incorporating a special filter holder in the sample stage and a clockwork motor to drive the translational stage during infrared scanning, thus providing an average analysis across the filter face. Filter samples were pre-treated with ethyl acetate to uniformly redeposit dust onto the filter and extract potential chemical interferences. Two absorbance maxima (1251 and 1291 cm(-1)), corresponding to the cellulose content of the wood, were suitable for quantitation of wood dust. Analysis of seven species of wood at 1291 cm(-1) showed an equivalent quantitative response for all species except maple. The response at 1251 cm(-1) was more variable across species but more sensitive for the softwoods. There was a statistically significant effect of particle size on the analytical response, so that analytical standards should be matched to the samples in terms of particle size distribution. Analytical limit of detection was approximately 0.08 mg of wood dust per sample with overall precision of about 6%. Comparison of DRIFTS and gravimetric analyses of 51 pure wood dust samples ranging from about 0.2 to 2 mg yielded a slope of 1.08 and r2 equal to 0.9. Other particulate contaminants common in the industrial wood processing industry showed little or no interference with the determination of wood dust by this method. 相似文献
115.
Simplified LCA and matrix methods in identifying the environmental aspects of a product system 总被引:1,自引:0,他引:1
In order to effectively integrate environmental attributes into the product design and development processes, it is crucial to identify the significant environmental aspects related to a product system within a relatively short period of time. In this study, the usefulness of life cycle assessment (LCA) and a matrix method as tools for identifying the key environmental issues of a product system were examined. For this, a simplified LCA (SLCA) method that can be applied to Electrical and Electronic Equipment (EEE) was developed to efficiently identify their significant environmental aspects for eco-design, since a full scale LCA study is usually very detailed, expensive and time-consuming. The environmentally responsible product assessment (ERPA) method, which is one of the matrix methods, was also analyzed. Then, the usefulness of each method in eco-design processes was evaluated and compared using the case studies of the cellular phone and vacuum cleaner systems. It was found that the SLCA and the ERPA methods provided different information but they complemented each other to some extent. The SLCA method generated more information on the inherent environmental characteristics of a product system so that it might be useful for new design/eco-innovation when developing a completely new product or method where environmental considerations play a major role from the beginning. On the other hand, the ERPA method gave more information on the potential for improving a product so that it could be effectively used in eco-redesign which intends to alleviate environmental impacts of an existing product or process. 相似文献
116.
117.
118.
Air pollution poses a serious threat to human health in Asia. This study analyzes the association of air pollutants and greenness with incidence rates of allergic rhinitis in Seoul at the administrative district level to gain insight into district-level urban policies to improve public health. A spatial regression model is constructed to investigate the correlation between allergic rhinitis incidence rates and five air pollutants measured at 128 air pollution monitoring stations around Seoul: sulfur dioxide (SO2), particulate matter less than 10 μm (PM10), ozone (O3), nitrogen dioxide (NO2), and carbon monoxide (CO). The allergic rhinitis incidence data are derived from the National Health Insurance Service’s database that includes the number of allergic rhinitis-related clinic visits by the patients over 20 years of age and living in Seoul. A kriging geostatistical interpolation was used to estimate average air pollution level of 423 administrative districts. To assess pollen concentrations that can affect allergic rhinitis, the average normalized difference vegetation index (NDVI) is measured based on the urban greenness. The model, controlling for built environment and socio-economic attributes, identifies the possibility of a weak association between allergic rhinitis incidence rates and carbon monoxide levels. The NDVI value is negatively correlated with allergic rhinitis incidence rates, implying a complicated aspect in relation to the effect of urban greenness. 相似文献
119.
Keun-Young Lee Hyun-A Kim Woo-Chun Lee Soon-Oh Kim Jong-Un Lee Young-Ho Kwon Kyoung-Woong Kim 《Environmental geochemistry and health》2012,34(1):151-151
Electrokinetic process for remediation of a shooting-range site was evaluated in this study. By field operation for 100 days, the newly designed electrokinetic system was evaluated for process stability, performance, and efficiency. The field site of this study was an abandoned military shooting range located in the Civilian Control Line of South Korea. The target area, only, was heavily contaminated by Pb and Cu to a depth of 0.5 m. After dry-sieving of the field soil to separate particulate Pb, two cells in a hexagonal (two-dimensional) arrangement, including ten anodes outside the cell and two cathodes in the middle, were prepared. The pH of each electrolyte was adjusted by use of concentrated HNO3, resulting in acid-enhanced electrokinetics. The monitoring results indicated that overall removal of heavy metals (Pb, Cu) was achieved, and that both heavy metals were removed from outside the cell. The average final efficiency of removal of Pb and Cu was 39.5 ± 35 and 63.8 ± 12%, respectively. Although the feasibility of this system was confirmed, for commercialization of the process confirmed drawbacks must be improved by further study. 相似文献
120.
Lee KY Kim HA Lee WC Kim SO Lee JU Kwon YH Kim KW 《Environmental geochemistry and health》2012,34(Z1):151-159
Electrokinetic process for remediation of a shooting-range site was evaluated in this study. By field operation for 100 days, the newly designed electrokinetic system was evaluated for process stability, performance, and efficiency. The field site of this study was an abandoned military shooting range located in the Civilian Control Line of South Korea. The target area, only, was heavily contaminated by Pb and Cu to a depth of 0.5 m. After dry-sieving of the field soil to separate particulate Pb, two cells in a hexagonal (two-dimensional) arrangement, including ten anodes outside the cell and two cathodes in the middle, were prepared. The pH of each electrolyte was adjusted by use of concentrated HNO(3), resulting in acid-enhanced electrokinetics. The monitoring results indicated that overall removal of heavy metals (Pb, Cu) was achieved, and that both heavy metals were removed from outside the cell. The average final efficiency of removal of Pb and Cu was 39.5 ± 35 and 63.8 ± 12%, respectively. Although the feasibility of this system was confirmed, for commercialization of the process confirmed drawbacks must be improved by further study. 相似文献