PM2.5 samples were collected during an annual monitoring campaign (January 2012–January 2013) in the urban area of Naples, one of the major cities in Southern Italy. Samples were collected by means of a standard gravimetric sampler (Tecora Echo model) and characterized from a chemical point of view by ion chromatography. As a result, 143 samples together with their ionic composition have been collected. We extend traditional source apportionment techniques, usually based on multivariate factor analysis, interpreting the chemical analysis results within a Lagrangian framework. The Hybrid Single-Particle Lagrangian Integrated Trajectory Model (HYSPLIT) model was used, providing linkages to the source regions in the upwind areas. Results were analyzed in order to quantify the relative weight of different source types/areas. Model results suggested that PM concentrations are strongly affected not only by local emissions but also by transboundary emissions, especially from the Eastern and Northern European countries and African Saharan dust episodes. 相似文献
Cloud point extraction (CPE) factors, namely Triton X-114 (TX-114) concentration, pH, ionic strength, incubation time, and temperature, were optimized for the separation of nano-sized copper(II) oxide (nCuO) in aqueous matrices. The kinetics of phase transfer was studied using UV–visible spectroscopy. From the highest separation rate, the most favorable conditions were observed with 0.2 %?w/v of TX-114, pH?=?9.0, ionic strength of 10 mM NaCl, and incubation at 40 °C for 60 min, yielding an extraction efficiency of 89.2?±?3.9 % and a preconcentration factor of 86. The aggregate size distribution confirmed the formation of very large nCuO–micelle assemblies (11.9 μm) under these conditions. The surface charge of nCuO was also diminished effectively. An extraction efficiency of 91 % was achieved with a mixture of TX-100 and TX-114 containing 30 wt.% of TX-100. Natural organic and particulate matters, represented by humic acid (30 mg/L) and micron-sized silica particles (50 mg/L), respectively, did not significantly reduce the CPE efficiency (<10 %). The recovery of copper(II) ions (20 mg/L) in the presence of humic acid was low (3–10 %). The spiked natural water samples were analyzed either directly or after CPE by inductively coupled plasma mass spectrometry following acid digestion/microwave irradiation. The results indicated the influence of matrix effects and their reduction by CPE. A delay between spiking nCuO and CPE may also influence the recovery of nCuO due to aggregation and dissolution. A detection limit of 0.04 μg Cu/L was achieved for nCuO. 相似文献
Pharmaceuticals are commonly found both in the aquatic and the agricultural environments as a consequence of the human activities and associated discharge of wastewater effluents to the environment. The utilization of treated effluent for crop irrigation, along with land application of manure and biosolids, accelerates the introduction of these compounds into arable lands and crops. Despite the low concentrations of pharmaceuticals usually found, the continuous introduction into the environment from different pathways makes them ‘pseudo-persistent’. Several reviews have been published regarding the potential impact of veterinary and human pharmaceuticals on arable land. However, plant uptake as well as phytotoxicity data are scarcely studied. Simultaneously, phytoremediation as a tool for pharmaceutical removal from soils, sediments and water is starting to be researched, with promising results. This review gives an in-depth overview of the phytotoxicity of pharmaceuticals, their uptake and their removal by plants. The aim of the current work was to map the present knowledge concerning pharmaceutical interactions with plants in terms of uptake and the use of plant-based systems for phytoremediation purposes. 相似文献
The main goal of this study was to assess both mercury (Hg) accumulation and organs’ specific oxidative stress responses of gills, liver and kidney of Dicentrarchus labrax with emphasis on seasonality. Fish were collected in cold and warm periods in three stations: reference, moderated and highly contaminated sites. Our results showed that seasonal factors slightly influenced Hg accumulation between year periods (cold and warm) and strongly affected organs’ response basal levels. In contrast, seasonality seemed not to influence oxidative stress responses, since similar response patterns were obtained for both year periods, and moderate degree of antioxidant responses was obtained. Moreover, the oxidative stress profile may be attributed to Hg contamination degree, which showed organ-specific response and accumulation patterns. Hence, gills showed to be able to adapt to Hg contamination, and in opposition, kidney and liver demonstrated some vulnerability to Hg toxicity. The critical Hg concentrations indicated specific threshold limits for each organ. Overall, seasonality should be taken into account in monitoring programmes, helping to characterize the individuals’ reference values of response and thus to discriminate between the effects induced by natural causes or by contamination. 相似文献
Annual CO2 emission tallies for 210 coal-fired power plants during 2009 were more accurately calculated from fuel consumption records reported by the U.S. Energy Information Administration (EIA) than measurements from Continuous Emissions Monitoring Systems (CEMS) reported by the U.S. Environmental Protection Agency. Results from these accounting methods for individual plants vary by ± 10.8%. Although the differences systematically vary with the method used to certify flue-gas flow instruments in CEMS, additional sources of CEMS measurement error remain to be identified. Limitations of the EIA fuel consumption data are also discussed. Consideration of weighing, sample collection, laboratory analysis, emission factor, and stock adjustment errors showed that the minimum error for CO2 emissions calculated from the fuel consumption data ranged from ± 1.3% to ± 7.2% with a plant average of ± 1.6%. This error might be reduced by 50% if the carbon content of coal delivered to U.S. power plants were reported.
Implications:
Potentially, this study might inform efforts to regulate CO2 emissions (such as CO2 performance standards or taxes) and more immediately, the U.S. Greenhouse Gas Reporting Rule where large coal-fired power plants currently use CEMS to measure CO2 emissions. Moreover, if, as suggested here, the flue-gas flow measurement limits the accuracy of CO2 emission tallies from CEMS, then the accuracy of other emission tallies from CEMS (such as SO2, NOx, and Hg) would be similarly affected. Consequently, improved flue gas flow measurements are needed to increase the reliability of emission measurements from CEMS. 相似文献
This study presents an evaluation of summertime ozone concentrations over North America (NA) and Europe (EU) using the database generated from Phase 1 of the Air Quality Model Evaluation International Initiative (AQMEII). The analysis focuses on identifying temporal and spatial features that can be used to stratify operational model evaluation metrics and to test the extent to which the various modeling systems can replicate the features seen in the observations. Using a synoptic map typing approach, it is demonstrated that model performance varies with meteorological conditions associated with specific synoptic-scale flow patterns over both eastern NA and EU. For example, the root mean square error of simulated daily maximum 8-hr ozone was twice as high when cloud fractions were high compared with when cloud fractions were low over eastern NA. Furthermore, results show that over both NA and EU the regional models participating in AQMEII were able to better reproduce the observed variance in ambient ozone levels than the global model used to specify chemical boundary conditions, although the variance simulated by almost all regional models is still less that the observed variance on all spatiotemporal scales. In addition, all modeling systems showed poor correlations with observed fluctuations on the intraday time scale over both NA and EU. Furthermore, a methodology is introduced to distinguish between locally influenced and regionally representative sites for the purpose of model evaluation. Results reveal that all models have worse model performance at locally influenced sites. Overall, the analyses presented in this paper show how observed temporal and spatial information can be used to stratify operational model performance statistics and to test the modeling systems’ ability to replicate observed temporal and spatial features, especially at scales the modeling systems are designed to capture.
Implications: The analyses presented in this paper demonstrate how observed temporal and spatial information can be used to stratify operational model performance and to test the modeling systems’ ability to replicate observed temporal and spatial features. Decisions for the improvement of regional air quality models should be based on the information derived from only regionally representative sites. 相似文献
Detailed hourly precipitation data are required for long-range modeling of dispersion and wet deposition of particulate matter and water-soluble pollutants using the CALPUFF model. In sparsely populated areas such as the north central United States, ground-based precipitation measurement stations may be too widely spaced to offer a complete and accurate spatial representation of hourly precipitation within a modeling domain. The availability of remotely sensed precipitation data by satellite and the National Weather Service array of next-generation radars (NEXRAD) deployed nationally provide an opportunity to improve on the paucity of data for these areas. Before adopting a new method of precipitation estimation in a modeling protocol, it should be compared with the ground-based precipitation measurements, which are currently relied upon for modeling purposes. This paper presents a statistical comparison between hourly precipitation measurements for the years 2006 through 2008 at 25 ground-based stations in the north central United States and radar-based precipitation measurements available from the National Center for Environmental Predictions (NCEP) as Stage IV data at the nearest grid cell to each selected precipitation station. It was found that the statistical agreement between the two methods depends strongly on whether the ground-based hourly precipitation is measured to within 0.1 in/hr or to within 0.01 in/hr. The results of the statistical comparison indicate that it would be more accurate to use gridded Stage IV precipitation data in a gridded dispersion model for a long-range simulation, than to rely on precipitation data interpolated between widely scattered rain gauges.
Implications:
The current reliance on ground-based rain gauges for precipitation events and hourly data for modeling of dispersion and wet deposition of particulate matter and water-soluble pollutants results in potentially large discontinuity in data coverage and the need to extrapolate data between monitoring stations. The use of radar-based precipitation data, which is available for the entire continental United States and nearby areas, would resolve these data gaps and provide a complete and accurate spatial representation of hourly precipitation within a large modeling domain. 相似文献
A forensic approach was used to evaluate sediments from Portão Stream, including analysis of metals, carbon (C) and nitrogen (N) stable isotopes, and C:N ratios. Samples collected at various points located along the stream were tested in order to investigate a possible illegal leachate input. The studied stream is heavily impacted by sewage and industrial discharges from two cities along its course. Among the metals analyzed, chromium (Cr) was noticeably the main pollutant, showing the highest levels, above regulatory limits, downstream from some potential sources of effluents enriched with this metal. Isotope analyses revealed a general trend of depletion in the heavier isotope along the stream for C and N. The exception was one point near a hazardous waste landfill, where relatively more enriched δ13C and δ15N values were found. The isotope and metal analysis results indicated that this site was affected by a particular source, demonstrating the combination of these parameters could be used for the discrimination of sources in a heavily polluted stream. Nevertheless, further investigations are necessary to provide a comprehensive evaluation of the biogeochemical processes involved in the incorporation of leachate in sediments to use this analysis as evidence for the illegal leachate discharge. 相似文献
This work applies optimization and an Eulerian inversion approach presented by Bagtzoglou and Baun in 2005 in order to reconstruct contaminant plume time histories and to identify the likely source of atmospheric contamination using data from a real test site for the first time. Present-day distribution of an atmospheric contaminant plume as well as data points reflecting the plume history allow the reconstruction and provide the plume velocity, distribution, and probable source. The method was tested to a hypothetical case and with data from the Forest Atmosphere Transfer and Storage (FACTS) experiment in the Duke experimental forest site. In the scenarios presented herein, as well as in numerous cases tested for verification purposes, the model conserved mass, successfully located the peak of the plume, and managed to capture the motion of the plume well but underestimated the contaminant peak. 相似文献
Bioprocesses, such as biofiltration, are commonly used to treat industrial effluents containing volatile organic compounds (VOCs) at low concentrations. Nevertheless, the use of biofiltration for indoor air pollution (IAP) treatment requires adjustments depending on specific indoor environments. Therefore, this study focuses on the convenience of a hybrid biological process for IAP treatment. A biofiltration reactor using a green waste compost was combined with an adsorption column filled with activated carbon (AC). This system treated a toluene-micropolluted effluent (concentration between 17 and 52 µg/m3), exhibiting concentration peaks close to 733 µg/m3 for a few hours per day. High removal efficiency was obtained despite changes in toluene inlet load (from 4.2 × 10?3 to 0.20 g/m3/hr), which proves the hybrid system’s effectiveness. In fact, during unexpected concentration changes, the efficiency of the biofilter is greatly decreased, but the adsorption column maintains the high efficiency of the entire process (removal efficiency [RE] close to 100%). Moreover, the adsorption column after biofiltration is able to deal with the problem of the emission of particles and/or microorganisms from the biofilter.
ImplicationsIndoor air pollution is nowadays recognized as a major environmental and health issue. This original study investigates the performance of a hybrid biological process combining a biofilter and an adsorption column for removal of indoor VOCs, specifically toluene.相似文献