A process combining catalyzed Fe(0)-carbon microelectrolysis (IC-ME) with activated carbon (AC) adsorption was developed for advanced reclaimed water treatment. Simultaneous nitrate reduction and chemical oxygen demand (COD) removal were achieved, and the effects of composite catalyst (CC) addition, AC addition, and initial pH were investigated. The reaction kinetics and reaction mechanisms were calculated and analyzed. The results showed that CC addition could enhance the reduction rate of nitrate and effectively inhibit the production of ammonia. Moreover, AC addition increased the adsorption capacity of biorefractory organic compounds (BROs) and enhanced the degradation of BRO. The reduction of NO3?–N at different pH values was consistently greater than 96.9%, and NH4+–N was suppressed by high pH. The presence of CC ensured the reaction rate of IC-ME at high pH. The reaction kinetics orders and constants were calculated. Catalyzed iron scrap (IS)-AC showed much better nitrate reduction and BRO degradation performances than IS-AC and AC. The IC-ME showed great potential for application to nitrate and BRO reduction in reclaimed water.
Although research regarding antibiotic resistance genes (ARGs) in aquaculture environments has gained increasing scientific interest, further studies are required to understand the abundances and removal mechanisms of ARGs during the entire rearing period of shrimp aquaculture. Thus, in this study, abundances, distributions and removal rates of ARGs in different environmental compartments of intensive shrimp farms in South China were investigated during the entire rearing period. The results indicated that sul1 and cmlA were the predominant ARGs in the water and sediment samples. Additionally, the total abundance of ARGs was higher in shrimp pond water than in the source water and farm effluent. Moreover, sediment samples indicated significantly higher ARG abundances than water samples from the shrimp ponds (P?<?0.05). Environmental factors were found to significantly affect the distribution of ARGs in shrimp rearing environments. Furthermore, stable ponds aided the removal of ARGs from shrimp pond water. This study accounted for temporal variations in ARG abundances as well as removal of ARGs in different environmental compartments during the entire shrimp rearing period. However, additional research is required to optimize the water treatment process for removal of ARGs from the aquaculture. 相似文献
Currently, activated coke is widely used in the removal of multiple pollutants from industrial flue gas. In this paper, a series of novel FexLayOz/AC catalysts was prepared by the incipient wetness impregnation for NH3-SCR denitrification reaction. The introduction of Fe-La bimetal oxides significantly improved the denitrification performance of activated coke at mid-high temperature, and 4% Fe0.3La0.7O1.5/AC exhibited a superior NOx conversion efficiency of 90.1% at 400 °C. The catalysts were further characterized by BET, SEM, XRD, Raman, EPR, XPS, FTIR, NH3-TPD, H2-TPR, et al., whose results showed that the perovskite-type oxide of LaFeO3 and oxygen vacancies were produced on the catalysts’ surfaces during roasting. Fe-La doping enhanced the amount of acid sites (mainly Lewis and other stronger acid sites) and the content of multifarious oxygen species, which were beneficial for NOx removal at mid-high temperature. Moreover, it was investigated that the effect of released CO from activated coke at mid-high temperature on the NOx removal through the lifetime test, in which it was found that a large amount of CO produced by pyrolysis of activated coke could promote the NOx removal, and long-term escaping of CO on the activated coke carrier did not have a significant negative impact on catalytic performance. The results of the TG-IR test showed that volatile matter is released from the activated coke while TG results showed that the weight loss rate of 4% Fe0.3La0.7O1.5/AC only was 0.0015~0.007%/min at 300–400 °C. Hence, 4% Fe0.3La0.7O1.5/AC had excellent thermal stability and denitrification performance to be continuously used at mid-high temperature. Finally, the mechanisms were proposed on the basis of experiments and characterization results.
The primary lens-walled compound parabolic concentrator (lens-walled CPC) has a significant advantage of a larger half acceptance angle as a static solar concentrator, but it also has a drawback of a low optical efficiency. In order to overcome this drawback, in this article, series of structure parameters were investigated and compared to further improve the optical efficiency within the half acceptance angle combined with the material properties. The average optical efficiencies of the improved lens-walled CPCs could achieve more than 82% within the half acceptance angle of 35?. Experiments were adopted to verify the credibility and validity of the simulation. Moreover, annual performance of the lens-walled CPCs comparison with that of the mirror CPC for Nottingham was analyzed. Results show that the improved lens-walled CPC has a higher optical performance for actual building application. 相似文献