首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   23篇
  免费   0篇
  国内免费   1篇
废物处理   2篇
环保管理   2篇
综合类   2篇
基础理论   2篇
污染及防治   10篇
评价与监测   2篇
社会与环境   4篇
  2022年   2篇
  2021年   1篇
  2020年   1篇
  2017年   2篇
  2014年   3篇
  2013年   4篇
  2012年   2篇
  2010年   1篇
  2009年   1篇
  2004年   2篇
  2003年   1篇
  2002年   3篇
  1995年   1篇
排序方式: 共有24条查询结果,搜索用时 0 毫秒
21.
This paper presents the design and laboratory evaluation of a personal cascade impactor. The system is compact, lightweight, and uses a single battery-operated sampling pump. It operates at a flow rate of 5 L/min and consists of four impaction stages, each equipped with slit-shaped acceleration nozzles, and a backup filter. The impactor was calibrated using polydisperse particles. The 50% cut points of the four stages were 9.6, 2.6, 1.0, and 0.5 microm, respectively. The backup filter is placed downstream of the fourth stage and is used to collect the particles with an aerodynamic diameter smaller than 0.5 microm (dp < 0.5 microm). The major feature of this novel sampler is its ability not only to fractionate the particles with an aerodynamic diameter smaller than 10 microm to the various size fractions, but also to collect them onto relatively small polyurethane foam substrates without using adhesives. Although the impaction substrates are not coated with adhesives such as grease or mineral oil, particle bounce and re-entrainment losses were found to be insignificant. Interstage losses of particles smaller than 0.5 microm were less than 10%; for fine particles, less than 5%; and for coarse particles, less than 12%. The pressure drop across the four stages and the backup filter were 0.015 kPa (0.153 cm H2O),0.025 kPa (0.255 cm H2O), 0.274 kPa (2.794 cm H2O), 0.323 kPa (3.294 cm H2O), and 0.370 kPa (3.773 cm H2O), respectively. Particles can be easily recovered from the foam substrates using aqueous extraction.  相似文献   
22.
Evaporative cooling of water in a small porous clay vessel was studied under controlled humidity conditions. In steady-state experiments performed at an ambient temperature of 23 °C, the cooling effect increased from 4.7 to 8.3 °C as the ambient relative humidity decreased from 60 to 15%. External heat and mass transfer coefficients, estimated from the steady-state measurements, were used in mathematical models to predict the experimentally observed transient temperature variation of the water under ramp changes of the ambient relative humidity. With a prototypical cool chamber containing water tested in Kolkata, India under an ambient temperature of 34.5–35 °C, the cooling effect reached a maximum of 7 °C between 3 and 3:30 PM and then declined to 4.5 °C around 6 PM.  相似文献   
23.
Environmental Science and Pollution Research - Environmental mutagens are chemical and physical substances in the environment that has a potential to induce a wide range of mutations and generate...  相似文献   
24.
Environment, Development and Sustainability - Selection of condenser cooling technology can affect the financial as well as technical viability of concentrating solar power (CSP) plants. Detailed...  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号