Dam failures usually cause huge economic and life losses , especially in urban areas where there is a high concentration of inhabitants and economic actors. In order to understand the physical mechanisms of the formation and development of dam-break flooding, lots of efforts have been put into different types of modelling techniques. However, most of existing models are 1D (one-dimensional) or 2D models based on the shallow water equations. In this paper, we present a 3D numerical modelling investigation of dam-break flow hydrodynamics in an open L-shape channel. A newly developed 3D unstructured mesh finite element model is used here. An absorption-like term is introduced to the Navier–Stokes equations in order to control the conditioning of the matrix equation in the numerical solution process and thus improve the stability. A wetting and drying algorithm is used here to allow the free surface height to be treated with a high level of implicitness and stability. The 3D model has been validated by comparing the results with the published experimental data. Good agreement has been achieved at six selected locations. This study shows that the 3D unstructured mesh model is capable of capturing the 3D hydraulic aspects and complicated local flows around structures in simulation of dam-break flows. 相似文献
In order to remove arsenic (As) from contaminated water, granular Mn-oxide-doped Al oxide (GMAO) was fabricated using the compression method with the addition of organic binder. The analysis results of XRD, SEM, and BET indicated that GMAO was microporous with a large specific surface area of 54.26 m2/g, and it was formed through the aggregation of massive Al/Mn oxide nanoparticles with an amorphous pattern. EDX, mapping, FTIR, and XPS results showed the uniform distribution of Al/Mn elements and numerous hydroxyl groups on the adsorbent surface. Compression tests indicated a satisfactory mechanical strength of GMAO. Batch adsorption results showed that As(V) adsorption achieved equilibrium faster than As(III), whereas the maximum adsorption capacity of As(III) estimated from the Langmuir isotherm at 25 °C (48.52 mg/g) was greater than that of As(V) (37.94 mg/g). The As removal efficiency could be maintained in a wide pH range of 3~8. The presence of phosphate posed a significant adverse effect on As adsorption due to the competition mechanisms. In contrast, Ca2+ and Mg2+ could favor As adsorption via cation-bridge involvement. A regeneration method was developed by using sodium hydroxide solution for As elution from saturated adsorbents, which permitted GMAO to keep over 75% of its As adsorption capacity even after five adsorption–regeneration cycles. Column experiments showed that the breakthrough volumes for the treatment of As(III)-spiked and As(V)-spiked water (As concentration = 100 μg/L) were 2224 and 1952, respectively. Overall, GMAO is a potential adsorbent for effectively removing As from As-contaminated groundwater in filter application.
The occurrence and spatial distribution of dechloranes including mirex, dechlorane plus (DP), dechlorane (Dec) 602, Dec 603, and Dec 604 in surficial sediments of Lake Taihu were investigated in this study. The concentrations of mirex and DP ranged from below detection limit (BDL) to 1.29 ng g?1 dw and 0.051 to 2.10 ng g?1 dw, respectively. Dec 602, Dec 603, and Dec 604 on the other hand, were BDL in any of the samples. The contamination levels of DP were higher than that of Mirex at 21 of all 22 sampling sites. Levels of mirex and DP in the lake sediments were correlated when an extremely high mirex value was removed. Both mirex and DP levels were correlated with the amount of organic matters in the sediment samples. Spatial distribution of mirex and DP suggested that these two chemicals in the lake had similar input sources except for one site. Comparison to previously reported flame retardants’ levels in the sediments shows that DP levels were similar with the levels of tetrabromobisphenol A, hexabromocyclododecane but lower than PBDEs and organophosphates levels in Lake Taihu. The higher levels in the north-east part of Lake Taihu adjacent to two major cities: Wuxi and Suzhou, indicated that city effluent might be a major source for DP contamination in the lake. 相似文献
ABSTRACT The catalytic incineration of dimethyl sulfide and dimethyl disulfide [(CH3)2S and (CH3)2S2] over an MnO/Fe2O3 catalyst was carried out in a bench-scale catalytic incinerator. Three kinetic models (i.e., the power-rate law, the Mars and Van Krevelen model, and the Langmuir-Hinshelwood model) were used to analyze the results. A differential reactor design was used for best fit of kinetic models in this study. The results show that the Langmuir-Hinshelwood model may be feasible to describe the catalytic incineration of (CH3)2S and (CH3)2S2. This suggests that the chemical adsorption of O2 molecules is important in this incineration. 相似文献
To achieve the hygienic safety of food waste used as animal feed, a hydrothermal treatment process of 60–110 °C for 10–60 min was applied on the separated food waste from a university canteen. Based on the microbial analysis of raw waste, the inactivation of hygienic indicators of Staphylococcus aureus (SA), total coliform (TC), total aerobic plate counts (TPC), and molds and yeast (MY) were analyzed during the hydrothermal process. Results showed that indicators' concentrations were substantially reduced after hydrothermal treatment, with a greater reduction observed when the waste was treated with a higher temperature and pressure and a longer ramping time. The 110 °C hydrothermal treatment for 60 min was sufficient to disinfect food waste as animal feed from the viewpoint of hygienic safety. Results obtained so far indicate that hydrothermal treatment can significantly decrease microbial indicators' concentrations but does not lead to complete sterilization, because MY survived even after 60 min treatment at 110 °C. The information from the present study will contribute to the microbial risk control of food waste–amended animal feed, to cope with legislation on food or feed safety.
Implications: Reduction of microbial indicators at ramping time and holding time during the hydrothermal process showed that hydrothermal treatment is an effective method to achieve hygienic feed from food waste to a certain extent, but the conditions researched in this study were not enough for the complete sterilization of food waste, because of the different heat resistance of bacteria and spores. 相似文献