首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   63篇
  免费   0篇
安全科学   3篇
环保管理   6篇
综合类   26篇
基础理论   12篇
污染及防治   11篇
评价与监测   4篇
社会与环境   1篇
  2021年   1篇
  2018年   2篇
  2017年   1篇
  2016年   4篇
  2015年   2篇
  2014年   1篇
  2013年   2篇
  2012年   5篇
  2011年   7篇
  2010年   3篇
  2009年   4篇
  2008年   4篇
  2007年   6篇
  2006年   3篇
  2005年   2篇
  2004年   2篇
  2003年   1篇
  2002年   2篇
  1997年   2篇
  1996年   1篇
  1995年   1篇
  1994年   1篇
  1993年   3篇
  1992年   1篇
  1989年   1篇
  1958年   1篇
排序方式: 共有63条查询结果,搜索用时 15 毫秒
51.
Passive sampling devices accumulate chemicals continuously from water and can provide time weighted average (TWA) concentrations of pollutants over the exposure period. Hence, they offer a number of advantages over other conventional monitoring techniques such as spot or grab sampling. The diffusive gradient in thin film (DGT) and the Chemcatcher passive samplers can be used to provide TWA concentrations of labile metals, but the approaches to their calibration differ. DGT uses diffusion coefficients of metals in the hydrogel layer, whereas Chemcatcher uses metal specific uptake rates, with both sets of values obtained under controlled laboratory conditions with constant aqueous metal concentrations. However, little is known of how such samplers respond to fluctuating concentrations. We evaluated the responsiveness of these two passive sampling devices to rapidly changing concentrations of Cd, Cu, Ni, Pb and Zn in natural freshwater, over a relatively short deployment time. Maximum metal concentrations in water were varied between 70 and 140 microg L(-1). Experiments were carried out in a tank with a rotating carousel system and filled with Meuse river water, allowing a degree of control over experimental conditions while using natural river water. Fluctuating concentrations were obtained by stepwise addition of standard solutions of the metals. The reliability and accuracy of the TWA concentrations measured by the samplers were assessed by comparison with concentrations of the metals in spot samples of water taken regularly over the deployment period. The spot samples of water were either unfiltered (total), filtered (0.45 microm) or ultrafiltered (5 kDa). Predictive speciation modelling using the visual MINTEQ programme was also undertaken. There was reasonable agreement between the TWA concentrations of Cd and Ni obtained with Chemcatcher and DGT and the total Cd and Ni concentrations measured in repeated unfiltered spot samples. For elements (i.e. Cu, Pb, Zn) that associate to a significant degree with suspended solids, colloids or dissolved organic carbon, or form complexes with large organic ligands, optimum agreement was with the filtered or ultrafiltered fractions and with the predicted inorganic and inorganic-fulvic acid associated fractions. While Chemcatcher-based TWA concentration ranges for Cu and Zn were in best agreement with the total filtered fraction, there was lack of agreement for Pb. The combined use of DGT devices with open pore (OP) and restricted pore (RP) gels allowed the labile fraction of metal associated with large organic ligands or DOC to be differentiated and quantified, since this is available to DGT OP but unable to diffuse into the DGT RP. This evaluation of the two sampling devices clearly demonstrated their ability to react reliably to transient peaks in concentration of metal pollutants in water and indicated where future efforts are needed to improve calibration data. Such samplers may prove valuable in responding to the monitoring requirements of the European Union's Water Framework Directive.  相似文献   
52.
Phthalates are common atmospheric contaminants used in the plastic industry. Ants have been shown to constitute good bioindicators of phthalate pollution. Hence, phthalates remain trapped on ant cuticles which are mostly coated with long-chain hydrocarbons. In this study, we artificially contaminated Lasius niger ants with four phthalates: dibutyl phthalate (DBP), diisobutyl phthalate (DiBP), di(2-ethylhexyl) phthalate (DEHP), and benzyl butyl phthalate (BBP). The first three have previously been found on ants in nature in Touraine (France), while the fourth has not. The four phthalates disappeared rapidly (less than 5 days) from the cuticles of live ants. In contrast, on the cuticles of dead ants, DEHP quantities remained unchanged over time. These results indicate that phthalates are actively absorbed by the cuticles of live ants. Cuticular absorption of phthalates is nonspecific because eicosane, a nonnatural hydrocarbon on L. niger cuticle, was similarly absorbed. Ants are important ecological engineers and may serve as bioindicators of ecosystem health. We also suggest that ants and more generally terrestrial arthropods may contribute to the removal of phthalates from the local environment.  相似文献   
53.
Under EU legislation, total arsenic levels in drinking water should not exceed 10 microg l(-1), while in the US this figure is set at 10 microg l(-1) inorganic arsenic. All rice milk samples analysed in a supermarket survey (n = 19) would fail the EU limit with up to 3 times this concentration recorded, while out of the subset that had arsenic species determined (n = 15), 80% had inorganic arsenic levels above 10 microg l(-1), with the remaining 3 samples approaching this value. It is a point for discussion whether rice milk is seen as a water substitute or as a food, there are no EU or US food standards highlighting the disparity between water and food regulations in this respect.  相似文献   
54.
This work aimed to evaluate whether the performance of passive sampling devices in measuring time-weighted average (TWA) concentrations supports their application in regulatory monitoring of trace metals in surface waters, such as for the European Union's Water Framework Directive (WFD). The ability of the Chemcatcher and the diffusive gradient in thin film (DGT) device sampler to provide comparable TWA concentrations of Cd, Cu, Ni, Pb and Zn was tested through consecutive and overlapping deployments (7-28 days) in the River Meuse (The Netherlands). In order to evaluate the consistency of these TWA labile metal concentrations, these were assessed against total and filtered concentrations measured at relatively high frequencies by two teams using standard monitoring procedures, and metal species predicted by equilibrium speciation modeling using Visual MINTEQ. For Cd and Zn, the concentrations obtained with filtered water samples and the passive sampling devices were generally similar. The samplers consistently underestimated filtered concentrations of Cu and Ni, in agreement with their respective predicted speciation. For Pb, a small labile fraction was mainly responsible for low sampler accumulation and hence high measurement uncertainty. While only the high frequency of spot sampling procedures enabled the observation of higher Cd concentrations during the first 14 days, consecutive DGT deployments were able to detect it and provide a reasonable estimate of ambient concentrations. The range of concentrations measured by spot and passive sampling, for exposures up to 28 days, demonstrated that both modes of monitoring were equally reliable. Passive sampling provides information that cannot be obtained by a realistic spot sampling frequency and this may impact on the ability to detect trends and assess monitoring data against environmental quality standards when concentrations fluctuate.  相似文献   
55.
Biological early warning systems represent a set of tools that may be able to respond to certain chemical monitoring requirements of recent European legislation, the Water Framework Directive (WFD2000/60/EC), that aims to improve and protect water quality across Europe. In situ biomonitoring was performed along the rivers Meuse (NL), Aller (GER) and Rhine (F) within the frame of the European Union-funded Project SWIFT-WFD. Gammarus pulex was used as a test organism during the evaluation of the Multispecies Freshwater Biomonitor(R) (MFB), an online biomonitor to quantitatively record different behaviour patterns of animals. At the river Meuse G. pulex reacted to pulse exposure of either a mixture of trace metals or of several organic xenobiotics, by showing up to 20% decreased locomotory activity (already at the 1st pulse) and increased mortality (at 2nd or 3rd pulse only). G. pulex deployed within the MFB system were observed to survive well at the monitoring station on the Aller (100%) and monitoring did not result in the measurement of chemical irregularities. In contrast, deployment at the monitoring station on the Rhine river demonstrated that the test organism was able to detect chemical irregularities by up to 20% decreased locomotory activity in the animals. The MFB proved to be an alert system for water quality monitoring at sensitive sites and sites with accidental pollution.  相似文献   
56.
In the course of our studies on the chemical ecology of the widely distributed Mediterranean ant Aphaenogaster senilis, we found that trail following is triggered by extracts of the poison gland and Dufour’s gland. To assess the specificity of the trail pheromone, we examined whether a cross-reaction exists between trails of A. senilis and the closely related species A. iberica. Specificity seemed to differ amongst these two species, because workers of A. senilis did not follow trails of A. iberica, whereas the latter followed trails made by both species. Chemical analyses of the glandular contents reveal that Dufour’s glands of both species contain mainly alkanes and alkenes exhibiting species-specific profiles. However, differences in the poison gland content of the two species were dramatic, with A. senilis showing high amounts of alkaloids that were completely absent in A. iberica.  相似文献   
57.
58.
Genetic amniocentesis performed at 7–14 weeks of gestation was studied in a series of 138 patients of whom 50 wanted termination of pregnancy (⩽ 12 weeks). The material for analysis consisted of 132 samples due to two sampling failures and four samples being handled incorrectly. Forty-eight samples (36 per cent) were taken at 7–12 weeks of gestation, mainly transvaginally (36/48:75 per cent). The success rate of culture and karyotyping increased with the duration of pregnancy, but was only satisfactory from week 11 onwards. The time until harvest was then 14–15 days. The transvaginal approach is easy to perform and was accepted by the women, but we experienced bacterial or fungal overgrowth in 17 per cent of these samples, whereas no infection occurred in the samples taken transabdominally (n = 96). We conclude that genetic amniocentesis is feasible from week 11, but further studies concerning side effects, especially focusing on the procedure-related abortion risk, should be carried out before early amniocentesis is routinely applied.  相似文献   
59.
We report cytogenetic results from a randomized Danish chorionic villus sampling (CVS) and amniocentesis (AC) study including 2928 placental and 1075 amniotic fluid specimens processed in the same laboratory. The results are presented in groups comparing CVS with amniocentesis and transabdominal (TA) CVS with transcervical (TC) CVS as randomized. More abnormalities and more ambiguous diagnostic problems were found in placental tissues than in amniotic cells. There were no diagnostic errors and no incorrect sex predictions. Mosaicism was detected in 1 per cent of all cases of CVS (discordancies included). When confirmation studies were done, 90 per cent were found to be confined to the placenta. Eight cases (0.7 per cent) of mosaicism/pseudomosaicism were seen in amniotic fluid specimens, and two cases of five with confirmation studies were confirmed in the fetus. The rate of mosaicism/pseudomosaicism in CVS and AC specimens differed (P <0.05). The rate of pseudomosaicism in cultures of villi and amniotic fluid cells was 0.5 and 0.6 per cent, respectively. Single-cell aneuploidy was observed in 1.8 per cent of villi and 1.4 per cent of amniotic fluid cell specimens. Maternal cell contamination (MCC) was seen more often after TC sampling (4.5 per cent) compared with TA sampling (1.5 per cent), but posed no problems in interpretation. Compared with the processing of cultured specimens, the short-term method of preparation of villi in our laboratory doubled the technicians' workload. For practical and economic reasons we have ceased the routine use of short-term preparations.  相似文献   
60.
Background: discussions with occupational physicians and a postal survey identified the shortcomings of previous programs, mainly found in the fields of occupational hygiene, ergonomics, environmental health and management.Objectives of the new program: basic knowledge (see content), the development of problem solving skills, scientific and social attitudes.Content: first year: occupational health practice, occupational hygiene, epidemiology, work physiology, toxicokinetics and dynamics and in service training (4 weeks). Second year: occupational pathology, environmental health, ergonomics, social legislation, safety, management and in service training (4 weeks). The total study load is estimated at about 1600 hours per year.Methods: interactivity is stimulated by the introduction of interdisciplinary seminars, project work in groups and Socratic dialogue. The objectives, contents and teaching and student-evaluation methods of the separate items were defined before selecting teachers.Finality of the program: a masters title sufficient to practice occupational medicine in Belgium. A subsequent postacademic training of 2 years, while at work, will be required for the title of specialist in occupational medicine, valid at European Union (EU) level. It will include preparing and publically defending a thesis.Statement: The collaboration of ex-students working in the field is essential in the development and quality assessment of adequate teaching programs.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号