首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   100篇
  免费   0篇
安全科学   1篇
废物处理   14篇
环保管理   4篇
综合类   43篇
基础理论   8篇
污染及防治   24篇
评价与监测   3篇
社会与环境   3篇
  2023年   1篇
  2021年   1篇
  2020年   1篇
  2019年   1篇
  2018年   1篇
  2017年   1篇
  2016年   1篇
  2015年   5篇
  2014年   5篇
  2013年   7篇
  2012年   7篇
  2011年   11篇
  2010年   3篇
  2009年   7篇
  2008年   4篇
  2007年   9篇
  2006年   7篇
  2005年   6篇
  2004年   5篇
  2003年   3篇
  2002年   2篇
  2001年   1篇
  1998年   1篇
  1997年   1篇
  1996年   1篇
  1995年   3篇
  1994年   1篇
  1993年   1篇
  1990年   2篇
  1964年   1篇
排序方式: 共有100条查询结果,搜索用时 15 毫秒
61.
Hot water recirculation systems (HWRS) in hotels and nursing homes, which are common in countries such as Spain, have been related to outbreaks of legionellosis. To establish the relationships of microbial and physicochemical parameters, especially protozoa, with the occurrence of Legionella in HWRS, 231 samples from hotels and nursing homes were analysed for Legionella, protozoa, heterotrophic plate counts (HPC) at 22 and 37 °C, Pseudomonas, metals, temperature and others. Legionella pneumophila was the dominant species isolated, and 22 % were sg. 1. The sampling method became particularly important in order to define which factors were involved on the occurrence of Legionella. Results showed that the bacteria and the accompanying microbiota were more abundant in the first flush water whose temperature was lower. The bacteria occurred in those samples with high HPC and were inversely correlated with high temperatures. Multivariate regression showed that a concentration above 1?×?105?CFU/100 mL of HPC at 37 °C, Fe above 0.095 ppm and the presence of protozoa increased significantly the risk of Legionella colonization, while univariant regression showed that the presence of Cu above 0.76 ppm and temperature above 55 °C diminished it. Therefore, to reduce the risk associated with Legionella occurrence in HWRS these parameters should be taken into consideration.  相似文献   
62.
Composting of two types of sludge produced in wastewater treatment plants, raw sludge (RS) and anaerobically digested sludge (ADS), has been systematically studied by means of the experimental design technique. The results have been analyzed using a full factorial experimental design in order to determine the optimal conditions for composting such sludges in terms of bulking agent particle size and bulking agent:sludge volumetric ratio, two of the key parameters to ensure an optimal performance of the composting process. The objective function selected was a simulated death kinetics of Salmonella, which was chosen as a model pathogen microorganism to represent the disinfection of the material. For both types of sludge, optimal values were found at 5mm bulking agent particle size and 1:1 bulking agent:sludge volumetric ratio when a Gaussian function was fitted to the experimental data. Pilot scale experiments using optimal values obtained were successfully undertaken and confirmed a full disinfection of the sludge by means of the composting process. A mathematical model to simulate the disinfection performance of a composting material is presented. The model can be applied to simulate the disinfection performance of a given pathogen.  相似文献   
63.
Conflicts between the conservation of biodiversity and other human activities have been and continue to be of increasing concern in the European Union, often having important political, economic, and environmental repercussions. These conflicts have been addressed in the European Union by using a wide array of top down and bottom up tools, with varying degrees of success. A new challenge is now facing Europe with the integration of 10 new countries in the European Union (EU) and an additional range of biodiversity-rich habitats placed under EU legislation. The rich biodiversity of the central and eastern European countries (CEEC) is likely to be threatened by some aspects of the integration process, and conflicts between the conservation of biodiversity and other human activities are expected. In this paper, we review certain existing conflicts between biodiversity conservation and human activities in the CEEC, expected conflicts associated with integration to the EU, particularly in terms of new policy and legislation implementation, and, finally, explore possible conflict management options.  相似文献   
64.
Three biomarkers of hydrocarbon exposure, liver 7-ethoxyresourfin-O-deethylase activity (EROD), fluorescent hydrocarbon compounds (FACs) in bilis, and the liver antioxidant enzyme catalase (CAT) were examined in the autochthonous fish species Barbus meridionalis collected in the river Fluvià (NE Catalunya, Spain) after an oil spillage. Four different locations were sampled, including the impacted site, upstream and downstream sites and a reference site. Biomarker responses were compared with diatom and macroinvertebrate community assemblage metrics (Specific Pollution Sensitivity index - IPS, and Iberian Biological Monitoring Working Party - IBMWP, respectively). Chemical analyses denoted that polycyclic aromatic hydrocarbon levels in sediment were much higher at the impacted site than in downstream reaches. Four fold increase of EROD activity together with increased levels of biliary FACs in barbs collected at the spilled site indicated exposure of inhabiting fish to the oil. Additionally, CAT activity was significantly depressed (four fold) when compared to other stations, thus suggesting that fish collected from the impacted sites could be more susceptible to suffer oxidative stress. Biological indices (particularly that of the diatom community IPS) showed slight significant effects between control and impacted sites, indicating that more tolerant taxa were favoured because of the oil spillage. These results support the need to include biochemical responses measured in local species in monitoring programmes aimed to diagnose specific pollution effects in stressed river ecosystems.  相似文献   
65.
A complex mechanical-biological waste treatment plant designed for the processing of mixed municipal solid wastes (MSW) and source-selected organic fraction of municipal solid wastes (OFMSW) has been studied by using stability indices related to aerobic (respiration index, RI) and anaerobic conditions (biochemical methane potential, BMP). Several selected stages of the plant have been characterized: waste inputs, mechanically treated wastes, anaerobically digested materials and composted wastes, according to the treatment sequence used in the plant. Results obtained showed that the main stages responsible for waste stabilization were the two first stages: mechanical separation and anaerobic digestion with a diminution of both RI and BMP around 40% and 60%, respectively, whereas the third stage, composting of digested materials, produced lesser biological degradation (20-30%). The results related to waste stabilization were similar in both lines (MSW and OFMSW), although the indices obtained for MSW were significantly lower than those obtained for OFMSW, which demonstrated a high biodegradability of OFMSW. The methodology proposed can be used for the characterization of organic wastes and the determination of the efficiency of operation units used in mechanical-biological waste treatment plants.  相似文献   
66.
This discussion explores one crucial point about the use of biodegradability indicators to monitor biological processes in organic solid waste treatment plants. Today, some different measures are being used for the determination of biodegradable organic matter and most of them are based on respiration indices (oxygen consumption or carbon dioxide production under aerobic conditions) or biogas production tests (under strict anaerobic conditions). However, it is not evident from scientific literature that both tests may be equivalent or comparable. This discussion includes the results obtained when trying to correlate both anaerobic and aerobic tests to complement the recent work published by Wagland et al. [Wagland, S.T., Tyrrel, S.F., Godley, A.R., Smith, R., 2009. Test methods to aid in the evaluation of the diversion of biodegradable municipal waste (BMW) from landfill. Waste Management 29, 1218–1226].  相似文献   
67.
68.
First trimester sonographic markers are the only markers achieving detection rates above 50% in the prenatal detection of fetal aneuploidy. Although potentially they are the best markers, some concerns have arisen about its clinical application. Pitfalls may be due to inability to examine the markers, incorrect assessment, or incorrect interpretation of the findings. Markers may be unable to be examined due to maternal (maternal body habitus, previous surgery) or fetal reasons (incompatible fetal position or fetal movements). Causes of incorrect interpretation may be insufficient image magnification, incorrect caliper placement (nuchal translucency), incorrect insonation angle (nasal bone), venous contamination (ductus venosus), or arterial contamination (tricuspid regurgitation), among others. Venous contamination in ductus venosus waveforms may mimic an abnormal blood flow when it is normal, and the opposite can also occur. Finally, incorrect interpretation of a substantially increased nuchal translucency may lead to a false impression of an ominous fetal prognosis or may be confounded with a cystic hygroma. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   
69.
70.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号