首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   37篇
  免费   6篇
  国内免费   18篇
安全科学   6篇
环保管理   1篇
综合类   31篇
基础理论   8篇
污染及防治   9篇
评价与监测   2篇
社会与环境   3篇
灾害及防治   1篇
  2022年   5篇
  2021年   3篇
  2020年   2篇
  2019年   1篇
  2018年   4篇
  2017年   2篇
  2016年   3篇
  2015年   4篇
  2014年   3篇
  2013年   6篇
  2012年   4篇
  2011年   6篇
  2009年   5篇
  2008年   2篇
  2007年   3篇
  2006年   3篇
  2005年   1篇
  2003年   1篇
  2002年   1篇
  1999年   2篇
排序方式: 共有61条查询结果,搜索用时 15 毫秒
61.

The quantitative assessment of landfill gas emissions is essential to assess the performance of the landfill cover and gas collection system. The relative error of the measured surface emission of landfill gas may be induced by the static flux chamber technique. This study aims to quantify effects of the size of the chamber, the insertion depth, pressure differential on the relative errors by using an integrated approach of in situ tests, and numerical modeling. A field experiment study of landfill gas emission is conducted by using a static chamber at one landfill site in Xi’an, Northwest China. Additionally, a two-dimensional axisymmetric numerical model for multi-component gas transport in the soil and the static chamber is developed based on the dusty-gas model (DGM). The proposed model is validated by the field data obtained in this study and a set of experimental data in the literature. The results show that DGM model has a better capacity to predict gas transport under a wider range of permeability compared to Blanc’s method. This is due to the fact that DGM model can explain the interaction among gases (e.g., CH4, CO2, O2, and N2) and the Knudsen diffusion process while these mechanisms are not included in Blanc’s model. Increasing the size and the insertion depth of static chambers can reduce the relative error for the flux of CH4 and CO2. For example, increasing the height of chambers from 0.55 to 1.1 m can decrease relative errors of CH4 and CO2 flux by 17% and 18%, respectively. Moreover, we find that gas emission fluxes for the case with positive pressure differential (?Pin-out) are greater than that of the case without considering pressure fluctuations. The Monte Carlo method was adopted to carry out the statistical analysis for quantifying the range of relative errors. The agreement of the measured field data and predicted results demonstrated that the proposed model has the capacity to quantify the emission of landfill gas from the landfill cover systems.

  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号