首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   38篇
  免费   0篇
废物处理   2篇
环保管理   1篇
综合类   4篇
基础理论   3篇
污染及防治   24篇
评价与监测   4篇
  2023年   1篇
  2015年   1篇
  2014年   4篇
  2013年   2篇
  2012年   1篇
  2010年   2篇
  2009年   2篇
  2008年   4篇
  2007年   3篇
  2006年   1篇
  2005年   1篇
  2004年   2篇
  2003年   3篇
  2002年   4篇
  2001年   2篇
  1997年   2篇
  1996年   2篇
  1984年   1篇
排序方式: 共有38条查询结果,搜索用时 15 毫秒
31.
Potable water samples (N?=?74) from 19 zip code locations in a region of Greece were profiled for 13 trace elements composition using inductively coupled plasma mass spectrometry. The primary objective was to monitor the drinking water quality, while the primary focus was to find novel associations in trace elements occurrence that may further shed light on common links in their occurrence and fate in the pipe scales and corrosion products observed in urban drinking water distribution systems. Except for arsenic at two locations and in six samples, rest of the analyzed elements was below maximum contaminant levels, for which regulatory values are available. Further, we attempted to hierarchically cluster trace elements based on their covariances resulting in two groups; one with arsenic, antimony, zinc, cadmium, and copper and the second with the rest of the elements. The grouping trends were partially explained by elements’ similar chemical activities in water, underscoring their potential for co-accumulation and co-mobilization phenomena from pipe scales into finished water. Profiling patterns of trace elements in finished water could be indicative of their load on pipe scales and corrosion products, with a corresponding risk of episodic contaminant release. Speculation was made on the role of disinfectants and disinfection byproducts in mobilizing chemically similar trace elements of human health interest from pipe scales to tap water. It is warranted that further studies may eventually prove useful to water regulators from incorporating the acquired knowledge in the drinking water safety plans.  相似文献   
32.
33.
Daily total ozone observations made during 1985–1993 by both the Total Ozone Mapping Spectrometer (TOMS) flown on the Satellite Nimbus-7 and the Dobson Spectrophotometer have been used in order to investigate the fluctuations of the daily broad-band and spectral solar ultraviolet radiation reaching the ground. This investigation has been performed by employing a recently developed parametric algorithm for the estimation of the spectral and broad-band solar ultraviolet radiation which takes the total ozone variations into consideration. Total ozone reductions during the summertime from 1985 to 1993 over Athens, Greece (37.6° N, 23.4° E), cause an increase in the ultraviolet irradiance which reaches the ground of 0.54 %, 0.98 %, 2.60 % and 0.79 % per decade for the months of July at 300 nm, 312 nm, 320 nm and UVB (280-320 nm), respectively.  相似文献   
34.
The carbon emissions trading market has created a need for standard methods for the determination of biogenic content (χB) in solid recovered fuels (SRF). We compare the manual sorting (MSM) and selective dissolution methods (SDM), as amended by recent research, for a range of process streams from a mechanical–biological treatment (MBT) plant. The two methods provide statistically different biogenic content values, as expressed on a dry mass basis, uncorrected for ash content. However, they correlate well (r2 > 0.9) and the relative difference between them was <5% for χB between 21% w/wd and 72% w/wd (uncorrected for ash content). This range includes the average SRF biogenic content of ca. 68% w/wd. Methodological improvements are discussed in light of recent studies. The repeatability of the SDM is characterised by relative standard deviations on triplicates of <2.5% for the studied population.  相似文献   
35.
GOAL, SCOPE AND BACKGROUND: Great interest in the unprecedented events of the major, sudden stratospheric warming and the ozone hole split over Antarctica in September 25, 2002 motivates a necessity to analyze the current understanding on the dynamics, chemistry and climate impacts that are associated with both events. METHODS: Significant progress in the analysis of the observational data obtained, as well as successful development and application of dynamical modeling, which have been achieved very recently, create a basis for the first survey on the role of the major, sudden stratospheric warming observed in the southern hemisphere and its relationship to the diminutive Antarctic ozone hole and its break up into two parts. RESULTS AND DISCUSSION: Special attention has been paid to assessments of the causes of the major warming event and the future expectations concerning the stratospheric ozone depletion effect. Among the principal results is the fact that, as the polar vortex elongated, it became hydrodynamically unstable, and this insta-, bility affected the upper troposphere and stratosphere. During the major, sudden stratospheric warming, the middle stratospheric vortex split into two pieces; one piece rapidly mixed with extra vortex air, while the other returned to the pole as a much weaker and smaller vortex. The polar night jet was considerably weaker than normal, and was displaced more poleward than has been observed in previous winters, resulting from a series of wave events (propagated from the troposphere) that took place over the course of the winter. Finally, the relative ozone decrease (increase) in the eastern Antarctic is tightly associated with westerly (easterly) zonal wind anomalies near the southern tip of South America, and the unusual behavior of the ozone hole in 2002 therefore appears to be caused by great easterlies in this region. CONCLUSIONS: The main conclusion is that the southern polar vortex and the diminutive ozone hole split into two parts in September 2002, due to the prevalence of very strong planetary waves, led to the appearance of a major, sudden stratospheric warming. Although there is evidence that sea surface temperature anomalies contributed to the excitation of the quite strong planetary waves over Antarctica in 2002, there is not yet a widely approved mechanism supporting that. RECOMMENDATIONS AND OUTLOOK:The appearance of the near-record size of the 2003 ozone hole confirmed that the 'no-ozone-hole' episode observed in the year 2002 does not denote a recovery of the ozone layer. Despite the current successful attempts to get a sufficient understanding for the genesis of both extraordinary events, more observations and further modeling efforts are necessary to more reliably assess the contribution of various dynamic mechanisms to the recently observed tropo-stratospheric surprises.  相似文献   
36.
In this paper, measurements of benzene, toluene, p,m-xylene, ozone (O3), nitrogen dioxide (NO2), and sulfur dioxide (SO2) made using the differential optical absorption spectroscopy (DOAS) technique during a 4-month period of summer 2000 (June-September) in Athens, Greece, are presented. An assessment of benzene mean value concentrations during this 4-month period exceeded 10 microg/m3, which is 2 times greater than the average yearly limit proposed by European authorities. Toluene measurements present mean values of approximately 33 microg/m3. Benzene and especially toluene measurements are highly correlated with NO2 and anticorrelated with O3. High values of benzene, NO2, and toluene are also correlated with winds from the southeast section, an area of industrial activity where emissions of volatile organic compounds (VOCs) have been recorded in previous studies. O3 is correlated with winds from the south-southwest section affected by the sea breeze circulation. Diurnal variations of O3, NO2, and SO2 concentrations are compatible with measurements from the stations of the Ministry of Environment's network. Outliers are combined with weak winds from the south-southwest. As far as p,m-xylene measurements are concerned, there is a poor correlation between gas chromatography (GC) and DOAS Opsis measurements, also observed in previous relevant campaigns and eventually a criticism in the use of the DOAS Opsis model for the measurement of p,m-xylene.  相似文献   
37.

Purpose  

The aim of this study is to investigate the potential effects of increased urbanization in the Athens city, Greece on the intrinsic features of the temporal fluctuations of the surface ozone concentration (SOC).  相似文献   
38.
ABSTRACT

Several recent studies have shown associations between ambient concentrations of particle mass (PM) and rates of morbidity and mortality in the general population. These studies have raised the issue of quality of coarse mass (CM, PM between 2.5 and 10 µm) data used for these purposes. CM data may have precision three or more times worse than the associated PM 2.5 or PM10 data, depending on the measurement method, PM 2.5 to PM 10 ratios, and CM concentrations. CM is measured either as the difference between collocated PM10 and PM2.5 samplers or more directly with a dichotomous (virtual impactor) sampler. CM precision for the difference method is degraded due to the increased errors inherent with using the difference between two independent measurements, as well as the high PM2.5 to PM10 ratios (and low CM concentrations) typical of the eastern United States. The dichotomous sampler (dichot) makes a more direct measurement of CM, but there is a potential for significant postexposure loss of particles from unoiled CM dichot filters, as well as uncertainties in the dichot’s CM channel enrichment factor. Compared to the dichot, low-volume inertial impactor samplers such as the Harvard Impactor (HI) or PM2.5 Federal Reference Method (FRM) are simpler to operate and maintain, provide sharper cut points, and do not require oiled filters to prevent loss of CM from the filter during transport. With the recent interest in CM spatial and temporal variability with respect to PM health effects, we have developed modifications to the HI PM method to provide measurements of 24-hour PM with estimated CM precision of better than 5% CV and r2 higher than 0.95, primarily by lowering field blank variability and increasing gravimetric analytical precision. These high-precision PM techniques are not limited to the HI sampler; they can also be applied to the PM2.5 FRM sampler. The measurement methods described here can be applied to future PM studies to avoid the potential problems with exposure assessment caused by CM measurements that have poor precision.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号