ABSTRACT Refrigerant pressure drop and temperature change in pipes are normally ignored in the thermodynamic analysis of traditional vehicle air conditioning system, this will result in serious errors. In this Paper, pressure drop and temperature difference are simulated in different pipes of electric vehicle (EV) heat pump system to analysis the effects of pipes in the actual EV heat pump system. The results indicate that the greater the mass flow, the faster pressure drop increases, the temperature difference decreases. Pressure drop of saturated liquid refrigerant is smaller than that of saturated gas refrigerant at the same saturation pressure and mass flow rate. The higher the refrigerant pressure (no phase change), the slower pressure drop decreases, the faster the temperature difference decreases. Pressure drop decreases with the increment of bending angle of the pipe. For EV heat pump system, suitable valves and less branches are helpful for energy saving of the system. Shortening the pipe between compressor and condenser can reduce temperature change obviously. Pressure drop per unit length in the pipe between evaporator and compressor is large especially in heating mode because of lower refrigerant density. It even reaches to over 100 times of that in the pipe between condenser and throttle valve in heating mode and has negative effects on the performance of the system. If the evaporator is closer to the compressor and the number of branches is less, then pressure drop will decrease a lot, which will be advantageous for energy saving of the heat pump system. 相似文献
• Selective molecularly imprinted polymer (MIP) binding gel was prepared.• MIP-DGT showed excellent uptake performance for antibiotics.• In situ measurement of antibiotics in wastewaters via MIP-DGT was developed.• The MIP-DGT method was robust, reliable, and highly sensitive. Urban wastewater is one of main sources for the introduction of antibiotics into the environment. Monitoring the concentrations of antibiotics in wastewater is necessary for estimating the amount of antibiotics discharged into the environment through urban wastewater treatment systems. In this study, we report a novel diffusive gradient in thin films (DGT) method based on molecularly imprinted polymers (MIPs) for in situ measurement of two typical antibiotics, fluoroquinolones (FQs) and sulfonamides (SAs) in urban wastewater. MIPs show specific adsorption toward their templates and their structural analogs, resulting in the selective uptake of the two target antibiotics during MIP-DGT deployment. The uptake performance of the MIP-DGTs was evaluated in the laboratory and was relatively independent of solution pH (4.0–9.0), ionic strength (1–750 mmol/L), and dissolved organic matter (DOM, 0–20 mg/L). MIP-DGT samplers were tested in the effluent of an urban wastewater treatment plant for field trials, where three SA (sulfamethoxazole, sulfapyridine, and trimethoprim) and one FQ (ofloxacin) antibiotics were detected, with concentrations ranging from 25.50 to 117.58 ng/L, which are consistent with the results measured by grab sampling. The total removal efficiency of the antibiotics was 80.1% by the treatment plant. This study demonstrates that MIP-DGT is an effective tool for in situ monitoring of trace antibiotics in complex urban wastewaters. 相似文献
Environmental Science and Pollution Research - This study proposed an in situ soil experimental system to quantify concentration and accumulation rates of polychlorinated biphenyl (PCB) congeners... 相似文献
China launched the One Belt & One Road (OBOR) initiative to minimize the energy resource shortage. The China’s nearby countries are rich in energy resources especially Middle East and North Africa (MENA) and Asian countries which make them ideal locations to cooperate with China in terms of energy resources, as 42.8% of world energy consumption belongs to OBOR countries. The present study elaborates the spatial distribution pattern of energy consumption disparities and its impact on environment. To do this, an entropy approach is utilized to compute the energy consumption inequalities in OBOR and its regions. The spatial and Pareto analysis show that MENA, East, and Southeast Asian economies have the highest degree of energy consumption inequalities, while European and Central Asian economies show the lowest energy consumption inequalities in OBOR region. The long-run estimates indicate that energy consumption inequalities enhance the CO2 emission in OBOR and its region except South and Southeast Asia. Financial development also has a significantly positive impact on CO2 emission in all models for OBOR and its regions except East Asia. Based on findings, the spatial distribution analysis is applicable to maintain balance in regional energy consumption inequality within OBOR and its regions.
Steroid estrogens such as estrone (E1), 17β-estradiol (E2), estriol (E3), and 17α-ethynylestradiol (EE2) have been suspected to be the main contaminants, which can affect the endocrine system of animals. Many authors have investigated these chemicals in the domestic wastewater treatment plants (WTP). However, wastewater from industries producing steroid contraceptives has not got ample attention. From the environmental point of view, the four steroids are very significant because even very low concentrations (ng/L) can cause reproductive disturbances in human, livestock and wildlife. The main purpose of the present investigation was to develop an analytical method for the determination of the four steroid estrogens present in WTP of a pharmacy factory, mainly producing contraceptive medicine in Beijing, China. Analysis was performed by solid-phase extraction (SPE) system and liquid chromatography combined with tandem mass spectrometry (LC/MS/MS). The average recoveries from effluent samples ranged from 88% to 103% and the precision of the method ranged from 9% to 4%. Based on 0.5-L wastewater samples, the limit of quantification (LOQ) was determined at 0.7 ng/L for E1, 0.8 for E2, 0.9 ng/L for E3, and 0.5 ng/L for EE2 in influent, and 1.0 ng/L for E2 and EE2, and 2.0 ng/L for E1 and E3 in effluent. In the influent samples, average concentrations of 80, 85, 73 and 155 ng/L were determined for E1, E2, E3 and EE2, respectively, showing that they were removed in this WTP to the extent of 79, 73, 85 and 67%, respectively. 相似文献
Dietary uptake is the major way that inorganic arsenic (iAs) enters into benthic fish; however, the metabolic process of dietborne iAs in fish muscle following chronic exposure remains unclear. This was a 40-day study on chronic dietborne iAs [arsenite (AsIII) and arsenate (AsV)] exposure in the benthic freshwater food fish, the crucian carp (Carassius auratus), which determined the temporal profiles of iAs metabolism and toxicokinetics during exposure. We found that an adaptive response occurred in the fish body after iAs dietary exposure, which was associated with decreased As accumulation and increased As transformation into a non-toxic As form (arsenobetaine). The bioavailability of dietary AsIII was lower than that of AsV, probably because AsIII has a lower ability to pass through fish tissues. Dietary AsV exhibited a high potential for transformation into AsIII species, which then accumulated in fish muscle. The largely produced AsIII considered more toxic at the earlier stage of AsV exposure should attract sufficient attention to human exposure assessment. Therefore, the pristine As species and exposure duration had significant effects on As bioaccumulation and biotransformation in fish. The behavior determined for dietborne arsenic in food fish is crucial for not only arsenic ecotoxicology but also food safety. 相似文献