Large cooking oil pool fires, occurring in industrial oil cookers, present a severe hazard to food processing plants due to their size and the large amount of hot oil involved. This paper reports a series of full-scale fire experiments conducted in a large industrial oil cooker mock-up. The characteristics of large cooking oil pool fires and the effect of oil depth and hood position in the oil cooker on fire growth were studied. The use of water mist for extinguishing large oil pool fires and their extinguishing performance under different discharge pressure and with different types of water mist systems were investigated. Experimental results showed that the cooking oil underwent a substantial expansion in volume during heating. The fires developed quickly once the oil auto-ignited. The fire growth rate was affected by the oil depth in the pan and the hood position in the oil cooker. The water mist fire suppression systems effectively extinguished large cooking oil fires and prevented them from re-igniting. Their extinguishing performance was determined by the type of water mist system, discharge pressure and hood position in the oil cooker. 相似文献
This paper presents detailed data on the thermal response of two 500 gal ASME code propane tanks that were 25% engulfed in a hydrocarbon fire. These tests were done as part of an overall test programme to study thermal protection systems for propane-filled railway tank-cars.
The fire was generated using an array of 25 liquid propane-fuelled burners. This provided a luminous fire that engulfed 25% of the tank surface on one side. The intent of these tests was to model a severe partially engulfing fire situation.
The paper presents data on the tank wall and lading temperatures and tank internal pressure. In the first test the wind reduced the fire heating and resulted in a late failure of the tank at 46 min. This tank failed catastrophically with a powerful boiling liquid expanding vapour explosion (BLEVE). In the other test, the fire heating was very severe and steady and this tank failed very quickly in 8 min as a finite rupture with massive two-phase jet release. The reasons for these different outcomes are discussed. The different failures provide a range of realistic outcomes for the subject tank and fire condition. 相似文献
This paper describes the results from a series of fire tests that were carried out to measure the effect of defects in thermal protection systems on fire engulfed propane pressure vessels.
In North America thermal protection is used to protect dangerous goods rail tank-cars from accidental fire impingement. They are designed so that a tank-car will not rupture for 100 min in a defined engulfing fire, or 30 min in a defined torching fire. One common system includes a 13 mm blanket of high-temperature ceramic fibre thermal insulation covered with a 3 mm steel jacket. Recent inspections have shown that some tanks have significant defects in these thermal protection systems. This work was done to establish what levels of defect are acceptable from a safety standpoint.
The tests were conducted using 1890 l (500 US gallon) ASME code propane pressure vessels (commonly called tanks in the propane industry). The defects tested covered 8% and 15% of the tank surface. The tanks were 25% engulfed in a fire that simulated a hydrocarbon pool fire with an effective blackbody temperature of 870 °C.
The fire testing showed that even relatively small defects can result in tank rupture if the defect area is engulfed in a severe fire, and the defect area is not wetted by liquid from the inside. A wall failure prediction technique based on uniaxial high-temperature stress rupture test data has been developed and agrees well with the observed failure times. 相似文献
This study compares highway crash incidence, injuries, and costs by vehicle type. Annual crash and injury incidence were estimated using Crashworthiness Data System (1988-1991), National Automotive Sampling System (1982-1986), General Estimates System (1992-1993), and Fatal Analysis Reporting System (1993) data. Costs were computed based on restraint use, body region, and threat-to-life severity of the injury. Costs were then allocated between vehicle types using three different methods in order to answer comparative safety questions. Motor vehicle and bicycle crash costs total $389 billion annually; 75% resulting from passenger vehicles. Motorcycles and bicycles have the highest costs per 1000 vehicle and passenger miles; costs per victim are highest for pedestrians, bicyclists, and motorcyclists. Costs per vehicle mile for heavy trucks and passenger cars are comparable but exceed costs for light trucks. Passenger vehicle occupants are safest if a crash occurs. Light truck, other single truck, and bus occupants have the lowest cost per passenger mile, but higher costs than air and rail travelers. Motorcyclists face the greatest risks. Combination trucks may not impose an excess risk to other drivers, but their drivers face large risks. 相似文献
This research used distal motor latency (DML) and vibration thresholds (VT) to evaluate 84 hand activity and wrist deviation combinations to determine the best association with carpal tunnel syndrome (CTS). Female volunteers, 2 healthy and 2 CTS diagnosed, were age matched and operated a keyboard for 4 hrs a day. Room temperature was 28°C(±2). Beginning DML and VT were taken with a relaxed neutral posture hand. The wrist was deviated in a randomly selected combination, and determinations were taken at 5-min intervals. The trial ended at 20 min or when discomfort was felt. The CTS conditions were discriminated by pain four times, DML once, and VT 14 times. Vibrometry was the most consistent CTS discriminator. The best VT results for wrist positions were obtained with wrist extension and extended extension, whereas the unclenched, clenched, and loaded power grip activities proved to be the most consistent hand activities. 相似文献
The aim of the study was to examine the effects of wearing an ice-vest (ca 1 kg) on physiological and subjective responses in fire fighters. The experiments were carried out on a treadmill in a hot-dry environment. The physical cooling effect of the ice-vest was measured with a thermal manikin. The ice-vest effectively reduced skin temperatures under the vest. On average, heart rate was 10 beats/min lower, the amount of sweating was reduced by 13%, and subjective sensations of effort and warmth were lower during work with the ice-vest compared to work without it. Thermal manikin tests indicated that the useful energy available from the vest for body cooling was rather high (58%). In conclusion, the ice-vest reduces physiological and subjective strain responses during heavy work in the heat, and may promote efficient work time by 10%. 相似文献
Child protection is an area of police work which has expanded in the last decade, leading to an increase in the number of police officers working in departments which specialise in investigating cases of child abuse. Police officers in this field may be at greater risk of experiencing secondary traumatic stress but there remains a paucity of research in this area of policing. Analogies can be drawn to existing research in policing and with social service workers involved in child protection. The paper finishes off with implications for police forces to ensure safe working environments and appropriate counselling for employees. 相似文献
AbstractManaging occupational safety in any kind of industry, especially in processing, is very important and complex. This paper develops a new method for occupational risk assessment in the presence of uncertainties. Uncertain values of hazardous factors and consequence frequencies are described with linguistic expressions defined by a safety management team. They are modeled with fuzzy sets. Consequence severities depend on current hazardous factors, and their values are calculated with the proposed procedure. The proposed model is tested with real-life data from fruit processing firms in Central Serbia. 相似文献