全文获取类型
收费全文 | 59篇 |
免费 | 0篇 |
专业分类
安全科学 | 10篇 |
废物处理 | 1篇 |
综合类 | 19篇 |
基础理论 | 6篇 |
环境理论 | 1篇 |
污染及防治 | 14篇 |
评价与监测 | 4篇 |
社会与环境 | 4篇 |
出版年
2022年 | 1篇 |
2019年 | 1篇 |
2017年 | 2篇 |
2016年 | 1篇 |
2015年 | 5篇 |
2013年 | 8篇 |
2012年 | 2篇 |
2011年 | 2篇 |
2010年 | 4篇 |
2009年 | 3篇 |
2007年 | 2篇 |
2006年 | 1篇 |
2005年 | 1篇 |
2003年 | 2篇 |
2002年 | 1篇 |
2000年 | 2篇 |
1999年 | 4篇 |
1995年 | 1篇 |
1993年 | 1篇 |
1989年 | 1篇 |
1988年 | 1篇 |
1984年 | 2篇 |
1982年 | 1篇 |
1970年 | 1篇 |
1964年 | 1篇 |
1962年 | 2篇 |
1960年 | 1篇 |
1956年 | 3篇 |
1955年 | 2篇 |
排序方式: 共有59条查询结果,搜索用时 31 毫秒
11.
The photocatalysed degradation of two selected priority organic pollutants, namely benzidine (1) and 1,2-diphenylhydrazine (DPH, 2) has been investigated in aqueous suspensions of titanium dioxide (TiO2) under a variety of conditions employing a pH-stat technique. The degradation was studied by monitoring the change in substrate concentration of the model compound employing HPLC analysis and the decrease in total organic carbon content, respectively, as a function of irradiation time. The degradation kinetics were studied under different conditions such as reaction pH, substrate and photocatalyst concentration, type of TiO2 photocatalyst and the presence of alternative additives such as H2O2, KBrO3 and (NH4)2S2O8 besides molecular oxygen. The degradation rates and the photonic efficiencies were found to be strongly influenced by the above parameters. Toxicity tests for the irradiated samples of benzidine measuring the luminescence of bacteria Vibrio fischeri after 30 min of incubation were also performed. 4-amino-biphenyl (7) and hydroquinone (13) were identified as intermediate products by GC/MS technique and probable pathways for the formation of the products are proposed. 相似文献
12.
Young M. Noh Detlef Müller Dong H. Shin Hanlim Lee Jin S. Jung Kwon H. Lee Maureen Cribb Zhanqing Li Young J. Kim 《Atmospheric environment (Oxford, England : 1994)》2009,43(4):879-888
Aerosol optical and microphysical parameters from severe haze events observed in October 2005 at Gwangju, Korea (35.10°N, 126.53°E) were determined from the ground using a multi-wavelength Raman lidar, a sunphotometer, and a real-time carbon particle analyzer and from space using satellite retrievals. Two different aerosol types were identified based on the variability of optical characteristics for different air mass conditions. Retrievals of microphysical properties of the haze from the Raman lidar indicated distinct light-absorbing characteristics for different haze aerosols originating from eastern and northern China (haze) and eastern Siberia (forest-fire smoke). The haze transported from the west showed moderately higher absorbing characteristics (SSA = 0.90 ± 0.03, 532 nm) than from the northern direction (SSA = 0.96 ± 0.02). The organic/elemental carbon (OC/EC) ratio varied between 2.5 ± 0.4 and 4.1 ± 0.7. 相似文献
13.
Thorsten Zellmann Alexandra S. Bäuerle Reiner Doluschitz Dietmar Jahnke Detlef Marell 《Environmental Sciences Europe》1999,11(1):49-54
The farming community is today faced with requests by various interest groups to implement environmental management systems (EMS). The series of items shows principle theoretical questions of the method and the advantages of EMS (part I and II), presents the practical outcome (part III) and give a recommendation for potential users of EMS in agricultural systems (part IV). The study conducted outlines the method of the implementing an EMS according to the Environmental Management and Audit System (EMAS) and ISO 14001. Further advantages and disadvantages for the agricultural industry are addressed. Even though terms such as site can not easily be defined or problems with open material cycles and structural particularity of agricultural farms there appears to be a benefit to implement. The transparency and documentation of the material flow as well as the economical benefits of an optimized organization count towards the EMS. Further EMS can be a means to strengthen the argumentative position for example with the public, authorities, banks or insurance. This concurs with minimizing company liabilities and obtaining governmental privileges (deregulation). 相似文献
14.
Toxicological evaluation for the hazard assessment of tire crumb for use in public playgrounds 总被引:1,自引:0,他引:1
Birkholz DA Belton KL Guidotti TL 《Journal of the Air & Waste Management Association (1995)》2003,53(7):903-907
Disposal of used tires has been a major problem in solid waste management. New uses will have to be found to consume recycled tire products. One such proposed use is as ground cover in playgrounds. However, concern has been expressed regarding exposure of children to hazardous chemicals and the environmental impact of such chemicals. We designed a comprehensive hazard assessment to evaluate and address potential human health and environmental concerns associated with the use of tire crumb in playgrounds. Human health concerns were addressed using conventional hazard analyses, mutagenicity assays, and aquatic toxicity tests of extracted tire crumb. Hazard to children appears to be minimal. Toxicity to all aquatic organisms (bacteria, invertebrates, fish, and green algae) was observed; however, this activity disappeared with aging of the tire crumb for three months in place in the playground. We conclude that the use of tire crumb in playgrounds results in minimal hazard to children and the receiving environment. 相似文献
15.
Detlef Hinneburg Eberhard Renner Ralf Wolke 《Environmental science and pollution research international》2009,16(1):25-35
Background, aim, and scope The fraction of ambient PM10 that is due to the formation of secondary inorganic particulate sulfate and nitrate from the emissions of two large, brown-coal-fired
power stations in Saxony (East Germany) is examined. The power stations are equipped with natural-draft cooling towers. The
flue gases are directly piped into the cooling towers, thereby receiving an additionally intensified uplift. The exhausted
gas-steam mixture contains the gases CO, CO2, NO, NO2, and SO2, the directly emitted primary particles, and additionally, an excess of ‘free’ sulfate ions in water solution, which, after
the desulfurization steps, remain non-neutralized by cations. The precursor gases NO2 and SO2 are capable of forming nitric and sulfuric acid by several pathways. The acids can be neutralized by ammonia and generate
secondary particulate matter by heterogeneous condensation on preexisting particles.
Materials and methods The simulations are performed by a nested and multi-scale application of the online-coupled model system LM-MUSCAT. The Local
Model (LM; recently renamed as COSMO) of the German Weather Service performs the meteorological processes, while the Multi-scale
Atmospheric Transport Model (MUSCAT) includes the transport, the gas phase chemistry, as well as the aerosol chemistry (thermodynamic
ammonium–sulfate–nitrate–water system). The highest horizontal resolution in the inner region of Saxony is 0.7 km. One summer
and one winter episode, each realizing 5 weeks of the year 2002, are simulated twice, with the cooling tower emissions switched
on and off, respectively. This procedure serves to identify the direct and indirect influences of the single plumes on the
formation and distribution of the secondary inorganic aerosols.
Results and conclusions Surface traces of the individual tower plumes can be located and distinguished, especially in the well-mixed boundary layer
in daytime. At night, the plumes are decoupled from the surface. In no case does the resulting contribution of the cooling
tower emissions to PM10 significantly exceed 15 μgm−3 at the surface. These extreme values are obtained in narrow plumes on intensive summer conditions, whereas different situations
with lower turbulence (night, winter) remain below this value. About 90% of the PM10 concentrations in the plumes are secondarily formed sulfate, mainly ammonium sulfate, and about 10% originate from the primarily
emitted particles. Under the assumptions made, ammonium nitrate plays a rather marginal role.
Recommendations and perspectives The analyzed results depend on the specific emission data of power plants with flue gas emissions piped through the cooling
towers. The emitted fraction of ‘free’ sulfate ions remaining in excess after the desulfurization steps plays an important
role at the formation of secondary aerosols and therefore has to be measured carefully. 相似文献
16.
17.
18.
19.
20.
Detlef Markus Aljoscha Hallermann Michael Paul Tim Langer Frank Lienesch 《Journal of Loss Prevention in the Process Industries》2013,26(2):324-328
Repetitive streamer discharges caused by transients, e.g. due to high frequency overvoltages, can ignite combustible mixtures, which has to be taken into account concerning the safety assessment of electrical apparatus for usage in hazardous areas. Hydrogen/air mixtures were ignited inside a closed vessel using a rod/plane electrode configuration. Alternating voltage with a frequency between 600 and 750 kHz and amplitudes of up to 20 kV was used to produce streamer discharges. The ignition process and the subsequent flame front propagation were examined with respect to mixture composition and several electrical parameters using time-resolved measurements of planar laser-induced fluorescence (PLIF) of OH radicals. A multiple pulse laser and detection system was used to assemble four images during one experiment. These measurements have given detailed information about the point of ignition and flame velocities. The experimental results will be used to validate numerical simulations of ignition by streamer discharges, which will yield deep insights into this specific ignition process. 相似文献