全文获取类型
收费全文 | 118篇 |
免费 | 0篇 |
专业分类
安全科学 | 4篇 |
废物处理 | 4篇 |
环保管理 | 8篇 |
综合类 | 30篇 |
基础理论 | 10篇 |
污染及防治 | 50篇 |
评价与监测 | 8篇 |
社会与环境 | 4篇 |
出版年
2017年 | 2篇 |
2016年 | 2篇 |
2015年 | 1篇 |
2013年 | 12篇 |
2012年 | 9篇 |
2011年 | 8篇 |
2010年 | 2篇 |
2009年 | 6篇 |
2008年 | 6篇 |
2007年 | 11篇 |
2006年 | 13篇 |
2005年 | 11篇 |
2004年 | 4篇 |
2003年 | 7篇 |
2002年 | 6篇 |
2001年 | 6篇 |
2000年 | 3篇 |
1999年 | 1篇 |
1995年 | 1篇 |
1994年 | 2篇 |
1993年 | 1篇 |
1991年 | 1篇 |
1990年 | 1篇 |
1989年 | 1篇 |
1983年 | 1篇 |
排序方式: 共有118条查询结果,搜索用时 78 毫秒
11.
Determination of atmospheric nitrate particulate size distribution and dry deposition velocity for three distinct areas 总被引:1,自引:0,他引:1
In this study, both atmospheric particulates and dry deposited particulates were collected at a highway intersection, coastal location and suburban area in Taichung, Taiwan for the characterization of nitrate containing particulates (NCPs) in size distribution and dynamic properties. Collected particulates were placed in contact with nitron (C20H16N4) to form distinctive products of NCPs, which were examined by a SEM. For total atmospheric particulates, the sum of NCP and non-nitrate containing particulate (NNCP), the average shape factor values are 1.69, 1.49, and 1.36 for the highway intersection, coastal area and suburban area, respectively. The calculated shape factors show no significant differences with sizes. Dry deposition fluxes and atmospheric concentrations at various size ranges were estimated. The mass distributed in fine particle range (相似文献
12.
Characterization of atmospheric PM10 and related chemical species in southern Taiwan during the episode days 总被引:1,自引:0,他引:1
The concentrations of atmospheric PM10 on days with episodes of pollution were examined at four different sampling sites (CC, DL, LY, and HK) in southern Taiwan. The related to particulates water-soluble ionic species (Na+, K+, Mg2+, Ca2+, NH4+, Cl-, NO3-, SO4(2-)), carbonaceous species (EC and OC) and metallic species (Zn, Ni, Pb, Fe, Mn, Al, Si, V) were also analyzed. On the episode days of this study, the PM10 mass concentration ranged from 155 to 210 microgm(-3), from 150 to 208 microgm(-3), from 182 to 249 microgm(-3), and from 166 to 228 microgm(-3) at CC, DL, LY, and HK, respectively. The results indicate that the dominant water-soluble species were SO4(2-), NO3-, NH4+, and Cl- at the four sampling sites on these days. Moreover, the high sulfate and nitrate conversion values (SOR and NOR) presented herein suggest that secondary formations from SO2 to SO4(2-) and from NO2 to NO3- are present in significant quantities in the atmosphere of southern Taiwan on episode days. In particular, high SOR and NOR verified that both SO4(2-) and NO3- dominated the increase of atmospheric PM10 concentration in southern Taiwan on episode days. 相似文献
13.
The organic precursors affecting the formation of disinfection by-products with chlorine dioxide 总被引:8,自引:0,他引:8
The object of this research was to study the formation of disinfection by-products by using chlorine dioxide (ClO2) as a disinfectant reacting with different properties of organic substance in natural aquatic environment. The adsorbent resin (XAD-4, XAD-7) was used to divide the organic matters in raw water into three groups. The influence of the function groups on structure, reaction tendency, and formation of disinfection by-products generated by the reaction of these organic substances with chlorine dioxide was explored. The experimental results show that the three different organic groups formed using adsorbent resin were hydrophobic substance, hydrophilic acid, and non-acid hydrophilics in proportions of 43%, 41%, and 16%, respectively. Within the raw water in our study, the hydrophilic substance had a higher distribution proportion than that described in general articles and journals, which indicates that this water was contaminated with pollution from human beings. The exploration of the reactivity of the three different organic substances with chlorine dioxide shows that the unit consumption of disinfection agent per unit organic matters (represented by ClO2/DOC) is in the following sequence hydrophobic substance > hydrophilic substance > non-acid hydrophilics. It indicated that larger molecular organic precursors had larger consumption of disinfectant. We also discovered that after the reaction of the three different organic substances with chlorine dioxide, the largest amount of disinfection by-products were generated by the non-acid hydrophilics. 相似文献
14.
Yuchi Lee Shanglien Lo Jeff Kuo Chinghong Hsieh 《Frontiers of Environmental Science & Engineering》2012,6(1):17-25
Microwave-hydrothermal treatment of persistent and bioaccumulative perfluorooctanoic acid (PFOA) in water with persulfate (S2O 8 2? ) has been found effective. However, applications of this process to effectively remediate PFOA pollution require a better understanding on free-radical scavenging reactions that also take place. The objectives of this study were to investigate the effects of pH (pH = 2.5, 6.6, 8.8, and 10.5), chloride concentrations (0.01?C0.15 mol·L?1), and temperature (60°C, 90°C, and 130°C) on persulfate oxidation of PFOA under microwave irradiation. Maximum PFOA degradation occurred at pH 2.5, while little or no degradation at pH 10.5. Lowering system pH resulted in an increase in PFOA degradation rate. Both high pH and chloride concentrations would result in more scavenging of sulfate free radicals and slow down PFOA degradation. When chloride concentrations were less than 0.04 mol·L?1 at 90°C and 0.06 mol·L?1 at 60°C, presence of chloride ions had insignificant impacts on PFOA degradation. However, beyond these concentration levels, PFOA degradation rates reduced significantly with an increase in chloride concentrations, especially under the higher temperature. 相似文献
15.
Chih-Wei Yang Tsung-Ling Hsieh Shiau-Feng Lin Chiuhsiang Joe Lin Hui-Ming Teng Yu-Fang Chiu 《Safety Science》2011,49(10):1309-1313
This study evaluated the operators’ signal-detection performance in video display unit (VDU) monitoring tasks of the main control room (MCR). So far the study of the relationship between VDU design strategy and human errors has been superficial. To validate the effect of VDUs design strategies on operating errors in the MCR, this present research adopted a within subject experimental design to develop different experimental treatments based on two types of display modes included consistent mode and mixed mode. A total of 13 undergraduate and graduate students were recruited as participants in the experiment. Dependent variables included situation awareness, reaction time, error frequency, and subjective performance. Some research support was found for the representation principles. The conclusions of this study could not only be implemented by the human-system interface (HSI) designers of a MCR in the advanced nuclear power plant (NPP) but also could be generalized to the extent that other digital workstation similar to the MCR. 相似文献
16.
17.
18.
Polycyclic aromatic hydrocarbons (PAHs) adsorbed on cigarette sidestream smoke particulates (CSSPs) have been regarded as important contributors to lung carcinogenesis in never smokers. However, limited information is available on PAH levels in cigarette sidestream smoke. Here we determine the concentrations of 22 PAHs, including 16 US EPA priority PAHs, in CSSPs generated from a high market-share domestic brand in Taiwan. Five of the 22 PAHs are undetectable. The remaining 17 PAHs constitute about 0.022% of the total mass of CSSPs. Near one fifth of the PAH mass come from IARC group 1 and group 2 carcinogens. Carcinogenic potency is equivalent to 144 ng benzo[a]pyrene per cigarette converted according to potency equivalency factors (PEFs). The CSSP condensate could activate AhR activity and induce AhR target gene expression. High concentrations of CSSPs also exhibited AhR-independent cytotoxicity. However, mixing the 17 PAHs as the composition in the CSSP condensate could not reconstitute either capacity. Since AhR activation and cytotoxicity are important mechanisms underlying carcinogenic potency, the results suggest that other component compounds play a more active role in carcinogenesis. The approach of individual PAH profiling plus PEF conversion commonly used in risk assessment is likely to underestimate the risk caused by environmental cigarette smoke exposure. 相似文献
19.
An organic Rankine cycle (ORC) is generally used for converting low-grade heat into electricity. In this study, an extensive literature survey was conducted to identify current research gaps on experimental ORC systems. Specifically, there is limited experimental data and limited details on thermal and expander efficiencies of ORC systems. In order to address these gaps, the objective of this study included developing a turbine ORC with a power output exceeding 50 kW and thermal efficiency exceeding 8% for a heat source temperature < 120°C. The experimental results indicated that the system achieved a net power output of 242.5 kW and a thermal efficiency of 8.3% (the highest value for a turbine ORC system for the heat source temperature below 120°C). Thus, the study addressed the gaps identified in the research area of ORCs. 相似文献
20.
Chang MC Shu HY Hsieh WP Wang MC 《Journal of the Air & Waste Management Association (1995)》2007,57(2):221-227
The sites contaminated with recalcitrant polycyclic aromatic hydrocarbons (PAHs) are serious environmental problems ubiquitously. Some PAHs have proven to be carcinogenic and hazardous. Therefore, the innovative PAH in situ remediation technologies have to be developed instantaneously. Recently, the nanoscale zero-valent iron (ZVI) particles have been successfully applied for dechlorination of organic pollutants in water, yet little research has investigated for the soil remediation so far. The objective in this work was to take advantage of nanoscale ZVI particles to remove PAHs in soil. The experimental factors such as reaction time, particle diameter and iron dosage and surface area were considered and optimized. From the results, both microscale and nanoscale ZVI were capable to remove the target compound. The higher removal efficiencies of nanoscale ZVI particles were obtained because the specific surface areas were about several dozens larger than that of commercially microscale ZVI particles. The optimal parameters were observed as 0.2 g iron/2 mL water in 60 min and 150 rpm by nanoscale ZVI. Additionally, the results proved that nanoscale ZVI particles are a promising technology for soil remediation and are encouraged in the near future environmental applications. Additionally, the empirical equation developed for pyrene removal efficiency provided the good explanation of reaction behavior. Ultimately, the calculated values by this equation were in a good agreement with the experimental data. 相似文献