排序方式: 共有38条查询结果,搜索用时 11 毫秒
1.
Ana Carolina Feitosa Cruz Marcela Bergo Davanso Giuliana Seraphim Araujo Lucas M. Buruaem Sandra Tédde Santaella Rodofley Davino de Morais Denis M. S. Abessa 《Environmental monitoring and assessment》2014,186(11):7035-7046
This study aimed to evaluate the sediment quality in the estuarine protected area known as Cananéia-Iguape-Peruíbe (CIP-PA), located on the southeastern coast of Brazil. The study was designed considering possible negative effects induced by the city of Cananéia on the sediment quality of surrounding areas. This evaluation was performed using chemical and ecotoxicological analyses. Sediments were predominantly sandy, with low CaCO3 contents. Amounts of organic matter varied, but higher contents occurred closer to the city, as well as did Fe and Total Recoverable Oils and Greases (TROGs) concentrations. Contamination by Cd and Cu was revealed in some samples, while concentrations of Zn were considered low. Chronic toxicity was detected in all tested sediments and acute toxicity occurred only in sediments collected near the city. The principal component analysis (PCA) revealed an association among Cd, Cu, Fe, TROG, fines, organic matter, CaCO3, and chronic toxicity, whereas acute toxicity was found to be associated with Zn and mud. However, because Zn levels were low, acute toxicity was likely due to a contaminant that was not measured. Results show that there is a broad area within the CIP-PA that is under the influence of mining activities (chronic toxicity, moderate contamination by metals), whereas poorer conditions occur closer to Cananéia (acute toxicity); thus, the urban area seems to constitute a relevant source of contaminants for the estuarine complex. These results show that contamination is already capable of producing risks for the local aquatic biota, which suggests that the CIP-PA effectiveness in protecting estuarine biota may be threatened. 相似文献
2.
3.
4.
5.
6.
Gomez Mario Alberto Ma Xu Chen Yiwen Wang Shaofeng Pollastri Simone Aquilanti Giuliana Cui Yubo Yao Shuhua Xiao Tangfu 《Environmental Chemistry Letters》2023,21(5):2519-2523
Environmental Chemistry Letters - Wastewater from the uranium mining industry contains toxic arsenate (AsO43–), selenate (SeO42–), and molybdate (MoO42–) that can be removed by... 相似文献
7.
8.
Polychlorinated biphenyls in contaminated soil samples evaluated by GC-ECD with dual-column and GC-HRMS 总被引:3,自引:0,他引:3
We present and compare results obtained from the analysis of polychlorinated biphenyls (PCBs) of a limited number of contaminated soil samples collected in three areas of Basilicata region (south of Italy). The levels of PCBs were evaluated by using two analytical methods: (i) parallel dual-column gas-chromatography with dual electron capture detectors (GC-ECD) and (ii) gas-chromatography coupled to high-resolution mass spectrometry (GC-HRMS) via electron impact ionization (EI) in the multiple ion monitoring mode (MIM, two ions per compound). Two extraction methods prior to sample cleanup were also examined: microwave-assisted extraction (MAE) and ultrasonic-assisted extraction (UAE). The MAE was the extraction procedure adopted using acetone/n-hexane (1:1, v/v) as it is mainly characterized by higher sample throughput and allowed reduced consumption of organic solvents. While extraction and analysis of spiked soil samples showed the applicability of both methods, systematic differences between the results were obtained for the sum of PCBs as a result of some non-detected congeners by GC-ECD compared with GC-HRMS. Indeed, high resolution MS using EI mode (electron energy 40eV) with a resolving power of 10,000 provides additional information about the contamination pattern. The GC-ECD screening of 11 soil samples led to just one sample non-compliant to as it was close to the guide value for soils fixed by the Italian legislation (i.e., 60ppb for private or urban soil). Using GC-HRMS, the amount of all PCBs found ranged from 5.4 to 127ppb with five soil samples non-compliant to the guide value. The number of identified congeners ranged from 1 to 9 and 9 to 18 using dual-column GC-ECD and GC-HRMS, respectively. 相似文献
9.
10.