This study evaluated both chronic and acute toxicity of ammonia in thermophilic anaerobic digestion of synthetic wastewater over a range of acclimation concentrations. The inhibition effects of ammonia, in terms of total ammonia nitrogen (TAN), under various pH values and acclimation conditions on thermophilic aceticlastic methanogens were investigated. Completely mixed thermophilic anaerobic reactors operated at a chemical oxygen demand (COD) loading rate of 4 g/lday and a solid retention time (SRT) of 7 days were subjected to TAN concentrations of 0.40, 1.20, 3.05, 4.92, and 5.77 g/l. The reactor operations presented a case of chronic inhibition and it was observed that TAN concentrations of 4.92 and 5.77 g/l caused a drop in methane production by as much as 39% and 64%, respectively with respect to control. Batch anaerobic toxicity assays (ATA) were also performed to evaluate the acute toxicity effects of TAN and pH on methanogenesis at thermophilic condition. Modeling based on the results of ATA indicated that aceticlastic methanogens acclimated to high concentrations of TAN were less sensitive to increase in TAN and could tolerate wider pH ranges. TAN concentration causing 100% inhibition occurred in the range of 8-13 g/l, depending on acclimation condition and system pH. 相似文献
The concentrations of fine particles and selected gas pollutants in the flue gas entering the stack were measured under several common operation modes in an operating coal power plant producing electricity. Particle size distributions in a diameter range from 10 nm to 20 μm were measured by a scanning mobility particle sizer (SMPS), and the flue gas temperature and concentrations of CO2 and SO2 were monitored by a continuous emission monitoring system (CEMS). During the test campaign, five plant operating modes were studied: soot blowing, bypass of flue-gas desulfurization (FGD), reheat burner operating at 0% (turned off), 27%, and 42% (normal condition) of its full capacity. For wet and dry aerosols, the measured mode sizes were both around 40 nm, but remarkable differences were observed in the number concentrations (#/cm3, count per square centimeter). A prototype photoionizer enhanced electrostatic precipitator (ESP) showed improved removal efficiency of wet particles at voltages above +11.0 kV. Soot blowing and FGD bypass both increased the total particle number concentration in the flue gas. The temperature was slightly increased by the FGD bypass mode and varied significantly as the rating of reheat burner changed. The variations of CO2 and SO2 emissions showed correlations with the trend of total particle number concentration possibly due to the transitions between gas and particle phases. The results are useful in developing coal-fired power plant operation strategies to control fine particle emissions and developing amine-based CO2 capture technologies without operating and environmental concerns associated with volatile amine emissions.
Implications: The measurement of the fine particle size distributions in the exhaust gas under several common operating conditions of a coal-fired power plant revealed different response relations between aerosol number concentration and the operating condition. A photo-ionizer enhanced ESP was demonstrated to capture fine particles with higher efficiency compared to conventional ESPs, and the removal efficiency increased with the applied voltage. The characteristic information of aerosols and main gaseous pollutants in the exhaust gas is extremely important for developing and deploying CO2 scrubbers, whose amine emissions and operating effectiveness depends greatly on the upstream concentrations of fine particles, SO2, from the power plant. 相似文献
The effect of sulfur content on diesel particulate matter (DPM) emissions was studied using a diesel generator (Generac Model SD080, rated at 80 kW) as the emission source to simulate nonroad diesel emissions. A load simulator was used to apply loads to the generator at 0, 25, 50, and 75 kW, respectively. Three diesel fuels containing 500, 2100, and 3700 ppm sulfur by weight were selected as generator fuels. The U.S. Environmental Protection Agency sampling Method 5 "Determination of Particulate Matter Emissions from Stationary Sources" together with Method 1A "Sample and Velocity Traverses for Stationary Sources with Small Stacks or Ducts" was adopted as a reference method for measurement of the exhaust gas flow rate and DPM mass concentration. The effects of various parameters on DPM concentration have been studied, such as fuel sulfur contents, engine loads, and fuel usage rates. The increase of average DPM concentrations from 3.9 mg/Nm3 (n cubic meter) at 0 kW to 36.8 mg/Nm3 at 75 kW is strongly correlated with the increase of applied loads and sulfur content in the diesel fuel, whereas the fuel consumption rates are only a function of applied loads. An empirical correlation for estimating DPM concentration is obtained when fuel sulfur content and engine loads are known for these types of generators: Y = Zm(alphaX + beta), where Y is the DPM concentration, mg/m3, Z is the fuel sulfur content, ppm(w) (limited to 500-3700 ppm(w)), X is the applied load, kW, m is the constant, 0.407, alpha and beta are the numerical coefficients, 0.0118 +/- 0.0028 (95% confidence interval) and 0.4535 +/- 0.1288 (95% confidence interval), respectively. 相似文献
To evaluate the possible influence of air pollutants on the incidence of respiratory tract neoplasm we studied 12 S?o Paulo City districts where air pollution is observed. We collected data on pollutants from 1981-1990 and correlated it with the incidence of larynx and lung neoplasms in 1997. Ozone was the pollutant that best correlated with the incidence of neoplasm. The correlation coefficients were 0.7234 (p=0.277) and 0.9929 (p=0.007) for lung and larynx cancer, respectively. There may be a relationship between air pollution and the incidence of respiratory tract neoplasm. This study, however, does not allow us to conclude that there is a causal relationship. 相似文献
The objective of this research was to examine the heterogeneous catalytic decomposition of H(2)O(2) and 4-chlorophenol (4-CP) in the presence of activated carbons modified with chemical pretreatments. The decomposition of H(2)O(2) was suppressed significantly by the change of surface properties including the decreased pH(pzc) modified with oxidizing agent and the reduced active sites occupied by the adsorption of 4-CP. The apparent reaction rate of H(2)O(2) decomposition was dominated by the intrinsic reaction rates on the surface of activated carbon rather than the mass transfer rate of H(2)O(2) to the solid surface. By the detection of chloride ion in suspension, the reduction of 4-CP was not only attributed to the advanced adsorption but also the degradation of 4-CP. The catalytic activity toward 4-CP for the activated carbon followed the inverse sequence of the activity toward H(2)O(2), suggesting that acidic surface functional group could retard the H(2)O(2) loss and reduce the effect of surface scavenging resulting in the increase of the 4-CP degradation efficiency. Few effective radicals were expected to react with 4-CP for the strong effect of surface scavenging, which could explain why the degradation rate of 4-CP observed in this study was so slow and the dechlorination efficiency was independent of the 4-CP concentration in aqueous phase. Results show that the combination of H(2)O(2) and granular activated carbon (GAC) did increase the total removal of 4-CP than that by single GAC adsorption. 相似文献
The methods of sample purification for determinations of organochlorine pesticides (OCPs) in sediment and fish muscle were investigated in this study. A two-step procedure with preliminary cleanup and florisil column fraction was adopted. The working conditions of florisil column were firstly optimized. As to preliminary cleanup, liquid-liquid extraction by mixture of dimethyl formamide (DMF) and hexane and sulphonation by concentrated sulfuric acid were applied respectively and compared for the studied samples. The results indicated that liquid-liquid distribution could effectively separate lipids from fish muscle extracts, while failed in elimination of chlorophyll extracted from the relicts of hydrophytes in the sediment sample. In view of the sample appearance and clarity of gas chromatogram, sulphonation was more suitable to purify the sediment sample, however, the recoveries of the spiked standards were poor. The use of eluting solvent with stronger polarity could improve the corresponding recoveries significantly. Due to complete loss of Dieldrin, Endrin, and Endrin aldehyde after sulphonation, this pretreatment was improper to the three components. Sulfur, as the particular disturbing element in sediment, could be removed sufficiently by addition of activated copper powder. The relevant detection limits of the selected methods for OCPs in the studied substrates were also provided. 相似文献