A new iron oxide catalyst, which has a superior oxidation activity in carbon monoxide and polyethylene (PE) combustion, was synthesized by an aqueous solution reaction. Catalytic oxidation of carbon monoxide over six kinds of hematite obtained from the goethite was done using a microcatalytic pulse reactor, and the composition of the hematite with the highest oxidation activity was determined. With the aim of suppressing dioxin formation on combustion, incineration tests of solid wastes in PE refuse bags with and without the goethite were carried out using a commercial semibatch-type incinerator with a combustion chamber of 6.2 m3. The result confirmed that the concentration of dioxins in the flue gas decreased considerably when the refuse was incinerated in PE bags manufactured with goethite. Received: July 24, 2000 / Accepted: October 18, 2000  相似文献   
52.
Trace analysis of volatile organic compounds (VOCs) during wildfires is imperative for environmental and health risk assessment. The use of gas sampling devices mounted on unmanned aerial vehicles (UAVs) to chemically sample air during wildfires is of great interest because these devices move freely about their environment, allowing for more representative air samples and the ability to sample areas dangerous or unreachable by humans. This work presents chemical data from air samples obtained in Davis, CA during the most destructive wildfire in California's history - the 2018 Camp Fire – as well as the deployment of our sampling device during a controlled experimental fire while fixed to a UAV. The sampling mechanism was an in-house manufactured micro-gas preconcentrator (µPC) embedded onto a compact battery-operated sampler that was returned to the laboratory for chemical analysis. Compounds commonly observed in wildfires were detected during the Camp Fire using gas chromatography mass spectrometry (GC–MS), including BTEX (benzene, toluene, ethylbenzene, m+p-xylene, and o-xylene), benzaldehyde, 1,4-dichlorobenzene, naphthalene, 1,2,3-trimethylbenzene and 1-ethyl-3-methylbenzene. Concentrations of BTEX were calculated and we observed that benzene and toluene were highest with average concentrations of 4.7 and 15.1 µg/m3, respectively. Numerous fire-related compounds including BTEX and aldehydes such as octanal and nonanal were detected upon experimental fire ignition, even at a much smaller sampling time compared to samples taken during the Camp Fire. Analysis of the air samples taken both stationary during the Camp Fire and mobile during an experimental fire show the successful operation of our sampler in a fire environment.  相似文献   
53.
We used the bacteriophages Qβ and MS2 to determine whether viruses are inactivated by aluminum coagulants during the coagulation process. We performed batch coagulation and filtration experiments with virus-containing solutions. After filtering the supernatant of the coagulated solution through a membrane with a pore size of 50 nm, we measured the virus concentration by both the plaque forming unit (PFU) and polymerase chain reaction (PCR) methods. The virus concentration determined by the PFU method, which determines the infectious virus concentration, was always lower than that determined by the PCR-based method, which determines total virus concentration, regardless of infectivity. This discrepancy can be explained by the formation of aggregates consisting of several virus particles or by the inactivation of viruses in the coagulation process. The former possibility can be discounted because (i) aggregates of several virus particles would not pass through the 50-nm pores of the filtration membrane, and (ii) our particle size measurements revealed that the virus particles in the membrane filtrate were monodispersed. These observations clearly showed that non-infectious Qβ particles were present in the membrane filtrate after the coagulation process with aluminum coagulants. We subsequently revealed that the viruses lost their infectivity after being mixed with hydrolyzing aluminum species during the coagulation process.  相似文献   
54.
Waste of electronic and electrical equipment (e-waste) generated in Indonesia is expected to increase due to high growth of the Indonesian economy and fast development in technology. As Indonesia has not yet had specified criteria on e-waste, in this study, e-waste is defined as any obsolete or unwanted electronic and electrical equipment that is introduced into the recycling and disposal process. The objective of this study is to estimate the e-waste generated in Indonesian households using the method of material flow analysis. The amount of generated e-waste could be used for constructing an e-waste recycling management system in Indonesia. E-waste materials that need to be treated could be known. In this study, some types of equipment, such as television, washing machine, refrigerator, personal computer, and mobile phone, were chosen to be tracers. Using the modified material flow analysis model proposed by Steubing et al. (Waste Manage 30:473–482, 38), the potential e-waste that was generated from households was estimated. The total estimated accumulation of generated e-waste from households in 2015 and 2025 is about 285,000 and 622,000 tonnes, respectively. If a proper recycling system was in place, a new source for valuable materials recovery would be created, as well as protecting the environment and health.  相似文献   
55.
Waste disposal is an important part of the life cycle of a product and is associated with environmental burdens like any other life-cycle stages. In this study, an integrated assessment for solid waste treatment practices, especially household solid waste, was undertaken to evaluate the impact contribution of household solid waste treatment alternatives towards the sustainable development by using Life Cycle Inventory Assessment method. A case study has been investigated under various possible scenarios, such as (1) landfill without landfill gas recovery, (2) landfill with landfill gas recovery and flaring, (3) landfill with landfill gas recovery and electric generation, (4) composting, and (5) incineration. The evaluation utilized the Life Cycle Inventory Assessment method for multiple assessments based on various aspects, such as greenhouse gas emission/reduction, energy generation/consumption, economic benefit, investment and operating cost, and land use burden. The results showed that incineration was the most efficient alternative for greenhouse gas emission reduction, economic benefit, energy recovery, and land use reduction, although it was identified as the most expensive for investment and operating cost, while composting scenario was also an efficient alternative with quite economic benefit, low investment and operating cost, and high reduction of land use, although it was identified as existing greenhouse gas emission and no energy generation. Furthermore, the aim of this study was also to establish localized assessment methods that waste management agencies, environmental engineers, and environmental policy decision makers can use to quantify and compare the contribution to the impacts from different waste treatment options.  相似文献   
56.
Plastic solid waste has become a serious problem when considering the disposal alternatives following the sequential hierarchy of sound solid waste management. This study was undertaken to assess the quantity and composition of household solid waste, especially plastic waste to identify opportunities for waste recycling. A 1-month survey of 130 households was carried out in Can Tho City, the capital city of the Mekong Delta region in southern Vietnam. Household solid waste was collected from each household and classified into ten physical categories; especially plastic waste was sorted into 22 subcategories. The average household solid waste generation rate was 281.27 g/cap/day. The compostable and recyclable shares respectively accounted for high percentage as 80.74% and 11%. Regarding plastic waste, the average plastic waste generation rate was 17.24 g/cap/day; plastic packaging and plastic containers dominated with the high percentage, 95.64% of plastic waste. Plastic shopping bags were especially identified as the major component, accounting for 45.72% of total plastic waste. Relevant factors such as household income and household size were found to have an existing correlation to plastic waste generation in detailed composition. The household habits and behaviors of plastic waste discharge and the aspects of environmental impacts and resource consumption for plastic waste disposal alternatives were also evaluated.  相似文献   
57.
The Bacillus subtilis rec-assay has been specially developed to detect genotoxicity in environmental water samples. The rationale of the B. subtilis rec-assay is based on the relative difference of survival of a DNA repair-recombination proficient strain and its deficient strain, which is interpreted as genotoxicity. This assay method can be very powerful in that it has higher sensitivity for the detection of mutagens in highly polluted waters than other bacterial mutation assays. Hydrophobic fractions from various environmental waters were fractionated by using XAD-2 resins and assayed, targeting the detection of organic genotoxic substances. Genotoxic response was detected in most of them, which revealed that many unknown micropollutants with genotoxicity occur in public water bodies. Positive response was also detected from a treated municipal solid waste (MSW) landfill leachate. Genotoxicity remaining in the treated effluent suggests that genotoxic micropollutants may pass through conventional water treatment processes such as activated sludge treatment process. Without proper control of waste quality and landfill facilities, waste landfill could be a heavy pollution source.  相似文献   
58.
The draft legislation on e-waste prepared by the Chinese national government assigns management responsibility to local governments. It is an urgent task for the municipal government to plan an effective system as soon as possible to divert the e-waste flow from the existing informal e-waste recycling processes. This paper presents a case study implemented in Beijing, the capital city of China, with the purpose of predicting the amount of obsolete equipment for five main kinds of electronic appliances from urban households and to analyse the flow after the end of their useful phase. The amount to be handled was 885,354 units in 2005 and is predicted to double by 2010. Due to consumption growth and the expansion of urbanization it is estimated that the amount will increase to approximate 2,820,000 units by 2020: 70% of the obsolete appliances will be awaiting collection for possible recycling, 7% will be stored at the owner's home for 1 year on average and 4% will be discarded directly and enter the municipal solid waste collecting system. The remaining items will be reused for about 3 years on average after the change of ownership. The results of this study will assist the waste management authorities of Beijing to plan the collecting system and facilities needed for management of e-waste generated in the near future.  相似文献   
59.
60.
We have conducted dust observations at a number of locations including Beijing, Hefei, Suwon, Fukue, Nagasaki, Tsukuba, and Sapporo using automated two-wavelength polarization lidars o study Asian dust phenomena, including generation, transport, and change during transport. We developed a method using the depolarization ratio for estimating the contributions of Asian dust and spherical air-pollution aerosols in observed aerosol mixtures. We analyzed the dust profiles statistically to derive climatological characteristics and year-on-year variations. We also studied dust source and transport path for each dust event using the regional chemical transport model CFORS. The statistical analysis clearly demonstrated the year-on-year variation of dust phenomena and the characteristics depending on the locations of the observational sites. Most major dust events in 2001 and 2002 originated in Inner Mongolia and/or Mongolia at the southern edge of a low-pressure area located in Siberia and were transported by strong westerlies. In 2003, the typical meteorological pattern for heavy dust cases accompanying a strong low in Siberia was not seen, except for one case in April. Furthermore, the lidar observation in Beijing suggests that less dust was generated in the source regions in Inner Mongolia and/or Mongolia, probably due to higher precipitation in 2003.  相似文献   